ML20086G932

From kanterella
Jump to navigation Jump to search
Telecopy AO 75-24:on 750421,refuel Area Exhaust Radiation Monitor RIS-3-17-458C Failed Downscale.Cause Under Investigation.Channel Placed in Tripped Condition in Compliance W/Tech Specs
ML20086G932
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 04/22/1975
From: Ullrich W
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20086G930 List:
References
AO-75-24, NUDOCS 8401130004
Download: ML20086G932 (1)


Text

--

XQ. ' 1

~

C

()

f/fl/

3\\

l h

f

-Q k'k2p fg D - [Q PHILADI1PHIA ELECTRIC C NPANY Feach Botton Atomic Power Station Delta, Pennsylvania 17314 April 22, 1975 f

j Mr. James P. O'Reilly, Director Office of Inspection and Enforcement p, g [gctreft,/

Region 1 United States Nuclear Regulatory Coecission 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

Abnornal Occurrence 24-Haur Notification Confirming John Franz' phone conversation with Mr. Walt Baunack, Region 1. United States Nuclear Regulatory Commission, on April 21, 1975.

Reference:

License Nunber DPR-56 Technical Specification

Reference:

3.2.D.2 and Table 3.2.D Report T.o.:

50-278-75-24 Ecport Date:

April 21, 1975 Occurrence Date:

April 21, 1975 Facility:

Peach Pctton Atonic Power Statica R.D. 1, Delta, Pennsylvania 17314 Identification of Occurrence:

Refuel Area Exhaust Radiation Monitor, E15-3-17-45CC, failed downscale.

Conditions Prior to Occurrence:

Reactor at full power.

Description of Occurrence:

During norr.s1 steady crate operation, the

'C' refueling area exhaust radiation monitor failed downscale.

Designation of Apparent Cause of Occurrence:

The apparent cause of the occurrence la under inecatigation at this tine.

Analysis of Occurrence:

Eecause this device is one of four arranged in a one-out-of-two twice Io; tic (which initiates a secondary containment ventilation systen isolatien on refueline, fIcor exhanst high radiation) such that the Icss of any one device will not deicat the logic, the safety isp11 cations are mininal.

Corrective Action:

This channel was isarediately placed in the tripped condition in cosspliance with Table 3.2.D of the Technical Specifications.

A Failure Data:

Previous failures reported as 50-277-75-20, 50-278-74-2, 50-278-75-21.

Ve truly you s, O*

lOM)

. T. Ullrich, Supetnitendent U

vach Bottom Atomic Power Station 1.'031 0401130004 750501

~

PDR ADOCK 05000278

~

U PDR L