File # 10200 Ref. # 10CFR50.73(A)(2)(iv) 1UELECTRIC July 11, 1995 7,,,,
Group Vice President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington. DC 20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 ACTUATION OF REACTOR PROTECTION SYSTEM LICENSEE EVENT REPORT 445/95-003-00 Gentlemen:
Enclosed is Licensee Event Report (LER) 95-003-00 for Comanche Peak Steam Electric Station Unit 1.
" Loss of Both Condensate and Both Feedwater Pumps Due To Failure of Non-safety Related Inverter Resulted in a Manual Reactor Trip."
TU Electric's initial corrective actions included repair of the identified inverter deficiencies and functional testing of the inverter. The final determination of the cause of this event along with the final corrective and preventive actions will be submitted in a supplement to this Licensee Event Report (LER).
Sincerely, C. L. Terry V
d By:
J."J Kelley Vice President of Nuclear Engineering and Support GM:cc Enclosure cc: