PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET PHILADELPHI A. PA.19101 (215) 8414ooo IJs;A *. ~.N,
,f<.-
^
June 13, 1975 Mr. A. Giambusso b:.
6 Director IT Y
h;q,,es[c.,*-
Division of Reactor Licensing.
f T-f Of fice of Nuclear Reactor Regulations
/
3 United States Nuclear Regulatory Comnission D\\ YI N #.% "
Washington, DC 20555 8
V.hlp
Dear Mr. Giambusso:
- Ci
),'
Subject:
Abnormal Occurrence
{
The following occurrence was reported to Mr. Walt Baunack, f
Region 1, Office of Inspection and Enforcement, United States Nuclear t
Regulatory Comnission on June 6,1975 Written notification was made i
to Mr. James P. O'Reilly, Region 1, Of fice of Inspection and Enforcement, United States Nuclear Regulatory Comnission on June 9,1975 In accordance with Section 6 7 2.A of the Technical Specifications, Appendix A of DPR-44 and DPR-56 for Unit 2 and Unit 3 Peach Bottom Atomic Power Station, the following report is being submitted to the Directorate of Reactor Licensing as an Abnormal Occurrerce.
Reference:
License Number DPR-44 and DPR-56 Technical Specification
Reference:
3.8.C.7.a Report No.:
50-277-75-41 and 50-278-75-33 t
Report Date:
June 13, 1975 Occurrence Date:
June 5, 1975 Facility:
Peach Bottom Atomic Power Station R.D. 1, Delta, Pennsylvania 17314 4
_. Identification of Occurrence:
i Main stack monitoring particulate filter and charcoal cartridge out of service.
U Conditions Prior to Occurrence:
' i Unit 2 shutdown and Unit 3 operating at 50% power.
g,,,}')') 2k f
Description of Occurrence.
j.n ', W
/~
l A violent thunderstorm caused water to be drawn into the main l
plant stack monitoring system sample 1ine.
In order to remove the moisture from the sample line, the particulate and charcoal filters were kD 0
gpy gggi d S
N N
L
f,\\
~,
1
(
\\
' )
Mr. A. Giambusso 50-2/I-75-41/50-278-75-35 June 13, 1975 Page 2 bypas sed. The bypass valve was inadvertently Icf t open for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, thereby removing the particulate and iodine sample filters from service for this period of time.
Designation of Apparent Cause of Occurrence:
Individual error is not closing the filter bypass valve after draining the moisture from the line.
Analysis of Occurrence:
During the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> period of time that the filter and cartridge were out of service, Unit 3 was running at a constant power le ve l. The main stack gas n.onitor was in service during this period of time. The gas release for this period of time varied between 70 Ci/sec. and 230 Ci/sec. (pe ak). Therefore, the percentage of Technical Specification limit from the main stack was (6 7X10-25 (3...C.1).
Since the iodine 8
and particulate release rates usually follow the gas release rates, it is unlikely that any significant release of iodine or particulates occurred during this period.
Corrective Action:
Filter cartridges were replaced and the filter bypass valve was closed. An instructional tag was affixed to the valve, cicarly indicating that the valve is to be kept closed except when cartridges are being changed.
Failure Data:
None previous.