ML20086G011
| ML20086G011 | |
| Person / Time | |
|---|---|
| Site: | Peach Bottom |
| Issue date: | 08/18/1975 |
| From: | Ullrich W PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| Shared Package | |
| ML20086G009 | List: |
| References | |
| AO-75-57, NUDOCS 8401090792 | |
| Download: ML20086G011 (1) | |
Text
4 I
r PHILADELPHIA ELECTRIC CO!!PANY /
P t a c h-Bo t.e "-
- t+-- t e P aue " A t n tion
~'
Delta Pennsylvania 1731k August 18, 1975 Mr. Janea P.
O'Reilly, Director l
Office of Inspection and Enforcement 1AN
{
Region 1 gg United States nuclear Regulatory Concission 631 Park Avenue King of Prussia. Pennsylvania 19406 i
Subject:
Ahn rirr al Occurrence 2L: Hour N'o t i f i c a i. l o ri
~
Confirning V.
T.
U11 rich's phone conversation with Mr. Jim Partlov, Region 1, United States Euclear Regulatory Cm.rd ssion.nn August 17. 29Y5
Reference:
Licence Nueber DPH-bh s.m t ut g
_._ m r_ 1en y,.
=r-n-
- i- _ - -
- - <m n - < r.? ; t _--- - - -
Report No.:
50-277-75-57 Report Date:
August 1C 1975 Occurrence Date:
August 17, 1975 Facility:
Peach Botton Atomic Power Station R.D. 1, Delta, Pennsylvania 1731h Identification of Occurrence:
Reactor Recirculation Systen Outboard Sample Isolation Valve, AO-2-2-L@
failure to close during test.
Conditione Prior to Occurrence:
Unit 2 reactor shut'down..
Description of Occurrence:
During the performance of ST 1.3, the PCIS Logic System Functional Testo valve AO-2-2-hD failed to close.
Designation of Apparent Cause of Occurrence:
Stuck solenoid valve.
Analysis of Occurrence:
The cafety significance of this occurrence is minimal since the inboard isolation valve AO-2-2-35 was found to close satisfactorily.
Corrective Action:
The solenoid valve was disassembled, cleaned.and repaired.
The valve was retested subsequent to repair.
In the interin, the inboard isolati@
valve AO-2-2-3d was caintained closed.
s t
failure Data:
j Previous failures of this type were reported as:
AO-50-277-75-14 (Failure of AO-2-39 to fully close)
AO-50-278-74-23 (Pailure of AO-2-39 to fully close)
Very truly yours,.
W / $ C t"l-d W. T. Ullrich, Superintendent Peach Botton Atocic Power Station' MS4 - svtumsvernreetermwamch.o-.r -,-
_ --.-- -- - -, -, mara 8401090792 750027 PDR ADOCK 05000277 S
PDR i
n.