1 South Ccrolma D$ctric & G16 Company John L Skolds i
P O Box 88 Vice President Jenkinsville. Sc 2906S Nucinar Operations
'903) 345-4D40
,SCE&G
~
NOV 141991 l
1 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Mr. G. F. Wunder Gentlemen:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION DOCKET NO. 50/395 OPERATING LICENSE NO. NPF-12 COMPLETION OF ACTIONS FOR NRC BULLETIN 88-11 By letter dated August 22, 1991, the NRC requested to be notified when the pipe supnort modifications for NRC Bulletih 88-11 were completed.
On Novembe.
1991, modifications were completed on two spring hangers, RCH002 and RCHO Also, plant operating procedures were revised to reflect the pressuriz
.nd reactor coolant loop differential temperature design basis limit of for plant heatups and cooldowns. This completes South Carolina tiearic & Gas Company's actions on NRC Bulletin 88-11.
Should you have any questions, please call 7.+ your convenience.
Very truly yours, John L. Skolds ARR:JLS:lcd c:
- 0. W. Dixon Jr.
NRC Resident Inspector R. R. Mahan J. B. Knotts Jr.
R. J, White C. C. Barbier S. D. Ebneter J. M. Cobb G. F. Wunder RTS (IE8 880011)
General Managers file (815.02) 9111ro;20 711114 pr;a ADOcK 0000077._
h r;
rDn i U NUCLEAR EXCELLENCE - A SUMMER TRADil!0N!
-. - -. - - -...