p-

?

John F. Betz Public Service Electric and Gas Company 80 Park Place Newark. N.J. 07101 201/622-7000 Vice-President - Electric Operation May 14, 1974

[p-6275 5//

U.S. Atomic Energy Commission Directorate of Regulatory Operations 7920 Norfolk Avenue Bethesda, Maryland 20014 Attention of Mr. Donald F. Knuth, Director Gentlemen:

NO. 1 AUXILIARY FEEDWATER STORAGE TANK NO. 1 UNIT l

SALEM NUCLEAR GENERATING STATI0h In compliance with AEC Regulation 100FR50(e), a verbal report was submitted on April 11, 1974 to Region 1, Directorate of Regulatory Operations concerning a crack in a roof plate of No. 1 Auxiliary Feedwater Tank at Salem Nuclear Generating' Station.

Our investigation cf the crack in the roof-plate of No. 1 Auxiliary Feedwater Tank revealed that in the process of removing a construction lug on one plate, the base material was torn.

The construction lugs were welded to the roof plate segments-to facilitate field forming of the roof during construction.

This type of lug was welded to the roof segments only.

To ensure that no other tears were in the-roof plates of'this and five othe r similar tanks, all areas where the lugs were.

welded to the plates were visually inspected and a random sampling of twelve areas, two on each; tank, were dye penetrant inspected.

No other tears were found.

The one crack in the tank roof-plate of No. - l Auxiliary Feedwater Storage Tank was ground out-and repaired.

From our visual inspection program of all locations:where con-struction lugs _ were welded to the roof and from the results of the dye penetrant inspection of twelve random areas,.we are-satisfied that this was an isolated occurrence and that these-tanks ~are structurally sound.

L 1

g/[d h

$f1'

{j 8311280093 740530-

\\^

PDR ADOCK 05000272 o

.PDn _

4 ig77 1

l O

o l

U.S. Atomic Energy 5-14-74 Commission If you have further questions on this item and its repair, we invite your inspection of the site repair records.

Very truly yours,

\\

)0Jr n r,I

\\

f i1 l l

,,/

5 4

,