o o

OPSEG Public Service Electric and Gas Company 80 Park Place Newar,k, N.J. 07101 Phono 201/622-7000 A,

S

,5 June 30, 1976 ms':

Director of Nuclear Reactor Regulation k

U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention: Mr. Karl Kneil, Chief Light Water Reactors Branch 2 Gentlemen:

REPORT ON ULTRASONIC EXAMINATION STEAM GENERATOR CLAD CRACKING NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 Public Service Electric and Gas Company hereby transmits its final report regarding ultrasonic examination of steam generator clad cracking. This report contains a description of the examination performed, results, conclusions and our proposed inservice inspection program in this matter.

Very truly yours, 11101 R. L. Pdtti General Manager - Projects Engineering and Construction Department EAL:adb Attachment

$$kISooWO l

S COPY SENT REGION 686S-The Energy People 95-2C01 (400M) 5-73 N