ML20086A749
| ML20086A749 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 11/14/1991 |
| From: | William Cahill, Walker R TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| CP-91-008, CP-91-8, TXX-91420, NUDOCS 9111190338 | |
| Download: ML20086A749 (1) | |
Text
~ ' ' "
t I,
6 Ew Log # TXX 91420 File # 10110 r
903.9 TUELECTRIC Hovember 14, 1991 William J. CoMil ?'
c,wva rmr.a..
U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
C0HANCHE PEAK STEAM ELECTRIC STATION (CPSES) - UHli 2 DOCKET NO 50 446 MSIV INTERNAL PITTlHG CORROSION SDAR CP-91 008 (RE0 VEST FOR EXTENSION)
Gentlemen:
On October 15, 1991, TU Electric orally notified the NRC of a potentially reportable deficiency in which internal pitting corrosion was found on all four Main Steam Isolation Valves (MS!Vs).
The investigation and the evaluation are continuing and our next report will be submitted no later than January 14, 1992.
Sincerely, G(/4,'
f' D'
William J. Cahill, Jr..
By:
Roger D. Walker Manager of Nuclear Licensing CEJ/gj c - Mr. R. D. Martin, Region IV Resident inspectors CPSES (2)
Mr. M. B. Fields NRR 9111190338 911114
/V 7
ADOCK0500g6 DR