Location The Saxton site is a 1.148 acre tract deeded from the Pennsylvania Electric Company to the Saxton Nuclear Experimental Corporation (SNEC).
It is located within the property of the Pennsylvania Electric Company near the Borough of Saxton, Pennsylvania, in Liberty Township, Bedford County, Pennsylvania. The Pennsylvania Electric Company property consists of approximately 150 acres along the Raystown Branch of the Juniata River.
2.
Exclusion Area Controls a.
The exclusion area consists of that portion.of the Saxton Nuclear Experimental Corporation property enclosed within the fence containing the Containment Vessel. See Figure 1.
b.
Except for authorized entry the following access points shall i
be maintained locked:
1)
-the gates to the Exclusion Area fence surrounding the l
Containment Vessel, I
2) the Containment Vessel access door, 3) the grating covering the Auxiliary Compartment stairwell in the Containment Vessel, i
i 4) and the Rod Room door.
c.
The Containment Vessel shall be equipped with an intrusion alarm to supplement the multiple physical barriers to intrusion.
d.
Employees of the Pennsylvania Electric Company's Line Department headquartered on the Penelec property shall report to the Vice President SNEC Programs / Program Director Saxton i
Nuclear Experimental Facility (SNEF) or the designated representative any observed indication of change in the-facility status as shown by smoke, fire, tornado, flood, or attempted break-in and take any immediate action authorized.
3.
Principal Activities Pennsylvania Electric Company personnel associated with electric power transmission and maintaining electric power distribution equipment are headquartered on the Pennsylvania Electric Company property. Activities permitted within the Exclusion Area shall.
include routine and emergency. inspections, maintenance associated J
with the possession of the Saxton Reactor Facility and characterization activities associated with the decommissioning of 1
the facility.
9507030291 950623 PDR ADOCK 05000146 P
^
B.
ADMINISTRATIVE AND PROCEDURAL CONTROLS i
Administrative controls relate to the organization, activities, procedures, record keeping, reporting and review and audit considered I
necessary to provide assurance and evidence that activities within the Exclusion Area are managed in a safe manner.
Procedure controls are applicable to activities for which it is considered necessary to provide assurance that they are performed in a safe manner.
1.
Organization 1
SNEC has the responsibility for safely maintaining the Containment Vessel and performing the characterization activities in support of its i
decommissioning. The organizational structure with reporting and communications lines is depicted in Figure 2.
i a.
The responsibilities of management and supervisory level personnel are as follows:
1.
SNEC President provides management oversight for all Saxton
{
activities and reports to the SNEC Board of Directors.
2.
President GPUNC provides full-time dedicated management for the purpose of conducting all nuclear activities safely and effectively.
The Executive Vice President SNEC and Vice President Nuclear Services Division assures that all division and corporate activities are performed in accordance with corporate policies, applicable laws, regulations, licenses and technical specifications.
l 3.
Vice President SNEC Programs / Program Director SNEF is responsible l
l for administration of all SNEC functions, direction of all decontamination and characterization activities and for assuring that the requirements of License No. DPR-4 and these Technical Specifications are implemented.
4.
SNEC Radiation Safety Officer (RS0) is responsible for the conduct and oversight of all Saxton Radiation Safety Activities through implementation of the SNEC Radiation Protection Plan. All radiological controls. personnel shall have stop work authority in matters relating to or impacting radiation safety.
5.
Group Radiological Controls Supervisor (GRCS) directly supervises radiation safety activities. The position reports to the RSO.
6.
The SNEF Site Supervisor reports to the Vice President SNEC Programs
/ Program Director SNEF. The Supervisor provides on-site management and continuing oversight of production activities.
b.
Other GPUN Division personnel provide SNEF management with technical l
support and project management capabilities.
c.
Staffing requirements are as follows:
1.
At least two individuals, one of which must be I
l knowledgeable in radiation monitoring and the radiological 2
Figure 2
( ',
SNEC Board of Directors I
l l
President SNEC
_____________________________________p I
l l
l I
I I
l l
Executive Vice President SNEC and Other GPUN a abon Safeh I
Vice President Nuclear Services
+ _ _ _
.i Division Support Nuclear Safety l
Division l
Assessment l
l Communications Department I
l Engineering Radiation Safety
--- -------- -- -k Vice President SNEC Programs /
4__j Program Director SNEF Officer l
Information Management SNEF Legal Group RadiologicalControls Supervisor (as needed)
Key-Direct reporting relationship Radiological Controls Other Services Indirect reporting relationship Technicians (as needed)
Division Departments 8
_