ML20086A044

From kanterella
Jump to navigation Jump to search
Telecopy AO 76-012:on 760527,helium Circulator 1B Tripped Twice.Caused by Buffer Seal Malfunction.Sys Operating Procedure Will Be Revised
ML20086A044
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 05/28/1976
From: Hillyard H
PUBLIC SERVICE CO. OF COLORADO
To: Howard E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20086A050 List:
References
AO-76-012, AO-76-12, NUDOCS 8311110222
Download: ML20086A044 (1)


Text

_ _ _ _ _ _ _ _ _ _ --

O'

~

O i bU INFOMASTFR PUP SFR CO DN 035370AIA9 17dPFST '

001 DENVFR COLO MAY PS ZIP 76012 F MORRIS HOkARD RFGION IVs RFGULATORY OPFRATION NUCLFAR RFOUL ATORY COMMISSION 611 RYAN PLAZA DR, SUITF 1000 )

ARLINGTON, TFXAS 76012 l

ON 5-P7-76. TkO UNFXPFCTFD TRIPS OF HELIUM CIRCLL ATOR IP OCCURRED.

INITT AL IND! RATIONS ARF TH AT A NEk MODI FICATION TO THF PLFFF6 SFAL MALFUNCTION TPIP LOGIC RFCU!PFS A PFVISION TO THE SYSTFM OPFR ATING PROCEDURE FOR PPS RFSFTTING FOLLOkING A TRIP DUE TO DUFFER SEAL M AL FUNCTION. THIS IS IDENTIFIFD AS APNORMAL OCCURRENCE 76/12 PER FT. ST VRAIN TFCHNICAL SPFCIFICATIONS SFCTION 2 1, PARAGRAPH G

( DFTFRMIN FD 5-28-76) . -

M k HILLYARD, JR.

  • NUCLFAR GENFRATING STATION FORT ST VRAIN

550 FIFTFFNTH STREET .

DFN VFR, COLORADO 80202

~'

l l ACCEPTFD 00001 *

~

P-PC f.

~,3 831IIIO222 760528 DR ADOCK 05000267 .

) '

PDR ,

, *i

. . 1 I

(-

l . .. . . .. ..

. . _