Telecopy Ro:During Routine Testing,Check Light for Suppression Chamber to Drywell Vacuum Breaker FCV-64-28M Failed to Go Out
ML20085L979
Person / Time
Site: Browns Ferry 
Issue date: 02/21/1974
From: Green H
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20085L978 List:
References
NUDOCS 8311070055
Download: ML20085L979 (2)


Text

M To b 2 02/21/74 E

, ICS IPMBNGZ CSP WE5 fem Union 5

u-4 R Q 2 0 5 7-2 9 8 3 1 6 M G M TOBN ENS AL 100 02=21 0542P E I!P'30303 l

O O

US ATOMIC ENERGY COMMISSION O

REGION 2 DIRECTORATE OF REGULATORY OPERATION 230 'EACHTREE ST NORTHWEST ATLANTA GA 30303 O

O O

SUBJECT BFAO=7411T AT CAM FEBRUARY 21 1974 0URING ROUTINE SURVEILLIEN CE TESTING OF SUPPRESSION CHAMBER TO DRYWELL VACUUM BREA'KER FCVa64-28H CHECK LIGHT FAILED TO Go OUT VALVE APPEARED TO OPERATE

()

PROPERLY BUT IS CONSIDER INOPERABLE FOR FULL CLOSURE DUE TO THE INOPERABLE CHECK LIGHT LIMIT SWITCH ALL OTHER VALVES OPERATE PROPERLY THE REACTOR WAS AT APPROXIMATELY 50 PERCENT POWER O