Text
r O
~
O public Service ('ompany CF Callwsde P. O.
Box 361, Platteville, Colorado 80651 May 12, 1975
.5 Mr. E. Morris Howard, Director
'N Nuclear Regulatory Commission
-f Region IV
,h. /
Office of Inspection and Enforcement 611 Ryan Plaza Drive
,,,, ({/
' [,r.'
,,yp. -
. *^',#
Suite 1000 Arlington, Texas 76012 REF: Facility Operating License No. DPR-34 Docket No. 50-267
Dear Mr. Howard:
Enclosed please find one copy each of Abnormal Occurrence Report No. @ U:267/75/1 @and Unusual Event Report No. 50-267/75/9, finals, submitted per the requirements of the Technical Specifications.
Very truly yours, D
4(
.u.s s.,f vq H. Larry Brey Superintendent-Operations Fort.St. Vrain Nuclear Generating Station HLB:il ec:
Mr. Angelo Ciambusso y aVI.
l J' 8311020194 750512 gDRADOCK 05000267 PDR 56H pupy gg.gi. ggj;ing 7
o 9 ~. ABNOPJ!AL OCCURRENCE REPORT DATE: May 7, 1975 OCCURRENCE DATE: May 1, 1975 FORT ST. VRAIN NUCLEAR GENERATING STATION PUBLIC SERVICE COMPANY OF COLORADO P. O. BOX 361 PLATTEVILLE, COLORADO 80651 REPORT NO. 50-267/75/10 ^ Final l IDENTIFICATION OF OCCURRENCE: I ' During a routine 6 months Preventive Inspection of K-9206X ("D" engine of "B" standby generator) a broken clutch disconnect mechanism was j discovered which rendered the declutch mechanism inoperable. g This'is identified as an Abnormal Occurrence, per Section 2.1, para (f) of the Technical Specifications. CONDITIONS PRIOR TO Routine Shutdown Steady State ?awer OCCURRENCE: Routine Load Change Hot Shutdown Cold. Shutdown X Other (specify) Refueling Shutdown Steady state power of 1.3% l -f I l _ Routine Startup Mwth during "B" series ( startup testing. The major plant parameters at the time of the event were as follows: l l Rtr. 1.3% MWth f Power t Elcet. O MWe Secondary Coolant Pressure 1185 .Paig ' Temperature 300 'F 200,000 '#/hr. -Flow n Primary-Coolant Pressure 408 psig a
- F Core inlet
] Temperature-317.5 _ 'F Core Outlet- -Flow 69,,000 __#/hr.
(* f) R a.. G O Page 2 DESCRIPTION OF OCCURRENCE: When the declutching mechanism of K-9206X was examined during a routine 6 months Preventive Maintenance laspection, one end of the pin holding the declutch-collar to the clutch me danism was found to be sheared off. The pin fits through one end of p' art (5), of the bottom picture, page 1 of attachment. Assembly is Part No. 6F6580, page 2 of attachment. There was no damage to any.other components. APPARENT CAUSE OF OCCURRENCE: Design Unusual Service Cond. Including Environ. Manufacture X Component Failure Installation /Const. ' Other (specify) e, Operator Procedure Through repeated operations the pin had failed. The collar has a tendency to " chatter" on the shaft, giving a. load cycling effect on the pin. Being in a het location, lubrication tends to flow off, increasing the tendency of the collar to " chatter". e ANAhYSIS OF OCCURRENCE: With one end of the pin sheared it is doubtful that the disconnect mechanism would have worked successfully if called on to do so. The collar would probably have " skewed" and may have resulted in damage to the fork mechanism. CORRECTIVE ACTION: All other enh nes have already' been
- inspected and have no pin failuren.
i The pin will be replaced and the' frequency of lubrication increased'to keep'the collar from chattering. y
'l ge 3' ~ FAILURE DATA / SIMIIAR REPORTED OCCURRENCES: None PROGRA!NATIC IMPACT: .None CODE IMNCT: None Recommended: Frank M. Mathie Superintendent-Maintenance Fort St. Vrain Nuclear Generating Station i / N 'C4(l Approved: 1 0< 1 C' FrpdericE.Swaet- -Superintendent Nuclear Production Public Service Company of Colorado ~
- --... t p p DISASSEMCLY AND ASSEMULY e v v REMO'VE COLLAR AND SLIDING SLEEVE ~ A w w.. ,"g '~~~ ,e start by: I I r a) remove clutch disc and hub assembly ~ '. h$ _. M Hose 'I y*,. ,1
- 1. Disconnect the grease fitting (2) from the clutch housing.
f s . - @}, ) i Y ' "j # ]f' M///;2 A53&1 x.. V, * - r f
- 2. Itemove the two collar bolts (3) and spacers
-.1,e,pc r.s.J, s -,,. -
- I i-
+,.t g L N ,s.
- r yo r'E '
b., ./ < (1)- ' " " I. ~ SUMT b ~ ~ ' ~ ~, - - cuir'c'a' Saarr % d Ida r l' e,' i.f i Tv - -
- 74. p l ',.
0 \\ * ;\\-HosF
- 3. Move"the clutch control lever forward until ff;
'f '\\ the collar (4) can be removed fron the sliding $" C' h j ' 1/ .j (. _ Colla Asg sleeve. L,,, // ... : A. Djd l '. 3, l:,h.m C W.;a,f"b q.(O Y ~ 4'.!, '!,2 Y., ; [.. s %w.l t- .vue. e. -.: u jr ' ANL;b'*/;j' ?$ t . cweil La,.:r y-d A FT s j a c
- 4. r N
, Q', *f n- -,I .j I.fs Q . \\ n' ^ ^ '* Y '\\ .o, .yy. i t..
- y. F
/ ::::g 9 / g( .v \\ s". . --.' )s b ~~f
- w.7_,o
- '..o._NE:.M nyLfn3 r* ; [q + ..'t r~ ta
- 4. licmove the other half of the collar (5) and
- ) -;
(.! \\ z... remove the sliding sleeve (G). .s ll.i 4, CA.' .e .\\
- t y
2. } I l, 'i, @N ~ g'i. yppy? e5*' : / N; {i j i - g i. w,,' BA u. M,s]sj 3 L..J,,3 ]yt,x 1l. ,.gji t g!t 4 4 l a i ! .I l-4 e (
- l.. e.
l I _l e t p. 0. 3 >w=.. 0 ..._______m. ____m-- m
~ U (d n j INSTALL COLLAR AND SLIDING SLEEVE-r,' ] y5,r *.'c' M N g. ,/ p \\}.% I ,' /{ I ~ /
- 1. Install the sliding sleeve on the shaft.
Mc5C h', @T,% a E\\ , 3.
- }2 r V'l
- a f'
[C k,'\\ '. Q)lla2 n:C rn.' - i%Q% ') f 1 SHAi T Y-- S I ) ;l/. ',, %_-i 3 l R I'
- 2. Install the collar (3), collar bolts (2) and o ix,
...,,, ;\\ 'p.*);. V"T'S / -.., 1'[/. ' D. s, spacers (1). d .f,. ~ a. c.9,. U'~*f.i.$. Ctorcel sa.r7 Yoru funif P'- snsa.d; e--- w % */',. .'/ d' u. . L u ;/ [- "
- . - ---3%K,
4;------ e, lr.x
- 3. Connect the grease fitting (4) to the housi1g.
' '/~/5 . b5$.'. w ~~' liv& ' (. Rose - 'a Costrid Accat. ( l_. h Y \\ Lh y\\ q. ff jed t. [. vs f: G l
- 4. Fill the. cDar and sliding sleeve with grease
. '. g 1 M g' until grease can be seen between the sliding ,,,,_M)..,. },.j. \\; l,, ,g ..fm# 5 sleeve and shaft. S 4 MT* 4
- Is /
g.;;7. w .t.
- K I I n'5f7-2
~ w..~. t s / ) 1 -t i end by: etorca Sa,a Yoa swr .. -d % * ', , ? ; %,'I a) install clutch disc and hub assembly
- 1 t
[=6%. 7 Ykk .._.A0b' -; At p i 's I k i1 l l
- Ih i
s' I y 9 g 1 9 l 1-- \\w,
- T.'
^~' '#""~****
- WN****
- I'****
s 9 e \\ .s -- - i d I t i. 2N7030 CLUTCH ASSEMBLY i Specification No. 33599 Part of 6LG220 Enc!osed Outch Group I I itssr3 tivta........: it s,3.tca r n_ _ _ _ _ _. 2 O 3,eci$.gotg ..._.g S' 4 0*PL^YE_-.....! l Z e-cottEm pin _.ets9e2 ,1::4719 $yt. .1 2FS375-cAs WT......I 1 R t'sG... ~. ~. 6t106 q -.0L397f _n.... 20e4ea rarisc.... 2 8-PIN 4-LEVER.___ 2L443F '] 1 4 *= * *
- -1 O
4-COTTER PIN _. 6L3963 2.44 41-642 c a.... _ _e M 4-pin ____ _ ___ eLJ9 73 'T 4:4 76c.Li.s _ _ _ _ _..s 9 .t of ',2_ ~ 4S4775 M00E.______.4** p dd ~ . I%" 3 PLATC_ _ 2L4432-2 3 AE _. 2 PLATE __ ___.2L4431-h# ~~ ~ 0 f *1FthlriY- .........1 l .h j..'.~- m, W
- -Mtr.__
__.2L44 2 9 -
- r..
f ') { i Y 2w4 4 40-stt EvC _ _ _....: g L._.~~~~- ( ___ } J ne,;gJim %.........g ag O V p lNUT. __.. 6rS 3951 [ g I I hf 8-Locn ___ __e res99f '~~ g p h t#My e. apActa__ ___3nr34s u, m c-n~ / 1 N 3pl97;:::"::"::"::": P.?.D N tt.1 .. urC_____ _,u m . f., ' 'h 1 n 2 n 4 9 3 eareassta...etsm 3 q tu,w.:. i.xsa -.. ~. p i. 4 p u.or ece._._._... 9 n/ n iniNc___ ___.2 u d33 DD4 5'C -LG0e A ASHER _ _ _6 J l-PIN... _.._3H9 5 73 -, m. m.. _ _...., y- ..s - c__ __ ___.,, m +um-_____..., 3 g .+.,u _Ja 4a a s su:m__ _...s 2-eeur.. _ _ _ _ _ v m s t x z.r;us........... yys 3M-m u -n r :.,,s._ _.. 2 -n O i e e srecou _ _.4a472 2.s-.v _ __
- . 54 2 2 -o. c.. _ _...:
x a sso g.s o 2 2rsn:-cu.c*.___._, E 2 ncv______ __ ets2c2 rem: -s:at.v._ _ _ _ _.2 g g gw swArr______.ereen
- pa s
2 sotr. _ ____ si4so m ~ l [ Q 2-tocn**s En_ ,a4s> l I ...-___.....,s,,._.. I g i L. j x ,o,,,,,
- = = - *. = = = = - - - =
L_ - - - - ' ~ - .}}