Telecopy AO AO-74-9,diesel Generator 1-1 Failed to Maintain Required Rated Load Monthly Test Run.Caused by Excessively Dirty Intake Filter.Filter Replaced
ML20085F851
Person / Time
Site: Palisades 
Issue date: 06/04/1974
From: Lewis J
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20085F843 List:
References
AO-74-9, NUDOCS 8308230514
Download: ML20085F851 (2)


Text

- - - -

e

)

w" m

l M LE

  • Tele ram i

/.

tuestern union I

t w

a..

VEE 265(1701)(1-036019A155)PD06h74 1659

' bb TLX CONSPOWER JKN L l$ J ZCZC 008 JACKSON MICH sj-2 onDERS1 PMS MR E JORDAN

},p,tmaiE EEI

]369 d"O 10 11 by Af D -

REGION III t.l EM 799 ROOSEVELT RO AD gj

/[

I GLEN ELLYN, IL /cO/3

~~

THIS TELEX CONFIHMS DISCUSSION TODAY WITH R J COOK CONCERNING PALISADES A0-74-9, DIESEL INTAKE FILTER PLUGGING.

DURIhG THE MONTHLY TEST RUN DIESEL 1-1 WOULD HAINTAIN ONLY 95 PERCENT

/

I RATED LOAD.

THE INTAKE FILTER WAS FOUND TO BE EXCESSIVELY 3

,/h DIRTY AND WAS REPLACED.

A TWO-HOUR TEST WAS THEN COMPLETED

('

i N.m JRpCESSFULLY.

gggeggohk40000255 t

S PDR

{

\\

gMM

  • Telegram 19ll JU.P -4 pH 6: 00 i

J G LEWIS CONSUMERS POWER COMPANY CBW CC: