ML20085E425

From kanterella
Jump to navigation Jump to search
LER AO-75-27:on 751221,water Lost to Mixing Basin When Cooling Tower Pump a Removed from Svc Resulting in Discharge Temp Rising Above Tech Spec Limit.Caused by Valve Closing Too Slow to Prevent Weir Overflow
ML20085E425
Person / Time
Site: Palisades 
Issue date: 01/05/1976
From: Sewell R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Kepper J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
LER-AO-75-27, NUDOCS 8308110438
Download: ML20085E425 (2)


Text

o o

UCENSEE EVENT REPORT

(/)

isades cONTnOL 8tOcx:I I Il11 I

maans ans T au assumen m,onmaTem,

RL.,

uC.NLn' Jr.1 W

N o..R T

T, c6lMlIlPlAlLl1l l0 l0 l-l 0l Ol'0l 0l Ol-l 0 l 0 l l4 l 1 l1l 1l 1l l 9l 9l 7 89 14 15 25 28 30 31 32 UJ n,i'rr R$kr DOCKETLetR UD) 6'd (9

t CATEGORY TYPE SOURct EVENT DATE REPORT DATE ECON' l

  • l
  • l Ltj LL_]

lo i s 101-1012151 51 1112121117 l 51 1011101517151 7 8 57 58 59 SO B1 88 68 74 75 80 EVENT E RPTON BS l Wher. the 'A' cooling tower pump was removed from service following plant shutdown. the l 7

89

@ l vater lost to the mixing basin caused the temperature at discharge to be h5 5 degrees l 80 7 89

@ l F.

The delta-T was 8.h degrees F which is above the Tech Spec limit of 5 degrees F.

l 80 7 89 80 3G l Due to the infrequency of occurrence and the negligible impact on environment, a Tech l 7

8

@9l Spec Change has been requested to permit short periods of time (continued on Li'ne 1 l

skshM Chuk COMPO(/J')

[/I) t cor CCot CODE ENT CCOE SLFPLER MANUFACTUNR

@ l Hl Fl~ W l Vl Al Ll Vl OlPl.

W l Bl 2l 5l 0l W

TON 7 89 10 11 12 17 43 44 47 48 CAUSE DESCRIPTON U7)

@ l The valve closing time is too slow to prevent veir overflow following pump trip.

l 8l 80 00 l

.]1 80 l

  • O lb?b (A/)

OTH(tRSTATUSut N or A 2.)

DSCOVERlDESCRSTON (AV B0 STATUS

% POWER DISCOVERY d

l 0l 0l 0l l NA l W l Environmental Monitoring Program l

7 0 9

10 12 13 44 45 46 80 Rft CF RE AS AMOUNT O CTMTV W

Wl NA l

l NA l

LOCAT RELEASE 7 8 9

10 11 44 45 PERSONNEL EXPOSURES H I 01 01(01) tv C)lotsCRetONh/) NA 80 NuMets 2V Z

7 89 11 12 13 l

PERSONNEL INJURIES 80 EE l 0l 0lN}2) lotscRescN(1])

NUMBE 0l NA 7 89 11 12 l

robstble Consequ' enc)es

/y 3

80 o

R l No effect on public health and safety.

7 89

]

LOSS OR OAMAGE TO FACILITY tres !

8 Lz}r)1ctscRescN 0 6)

NA 7 89 10 l

PUBLOTY (3 2) 80

'@89[ Copies of this report are being sent to MI news media.

~-

l 80 ADDITONAL FACTORS (.3 7)

@ l_ vith delta-T above 5 degrees F.

(AO-75-27)

' B9 8308110438 760105 l

PDR ADOCK 05000255 80

& \\_

S PDR 7 09 80

O Q

' *g c..

.p 1

consumers 4,

Power Nd Company

)

0[

W U

o.n.. on.c..: nie w.. u cn...a 4..no.. s.c..on. u.cn...a 4 o2o 3. coa. eo 7 es.os so

,g %;th, !.fx 9

-,N January 5, 1976

,,,4 j

i l

}

. Alli t9{$ y

\\. ' # "cI5'OE,@ " x.s 9

~-

Ns

<N' N'

A ~; /

Mr. J. G. Keppler

j.-

US Nuclear Regulatory Comission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255, LICENSE DPR-20 PALISADES PLANT Transmitted attached is a " License Event Report" for the Palisades Plant.

Ralph B. Sewell (Signed)

Ralph B. Sewell Nuclear Licensing Administrator CC: Director of Nuclear Reactor Regulation, USNRC 111

' COPY SENT REGION 2

___________--__O

_