[, Gilbert / Commonwealth engineers and consuitants GILBERT ASSOCIATES, INC., P. O. Box 1498, Reading, PA 19603/Tel 215 775-2600/ Cable Gilasoc/ Telex 836-431 June 30, 1983 N.R. BARKER Vice President and General Manager Quality Assurance Division United States Nuclear Regulatory Commission Office of Inspection and Enforcement Washington, DC 20555 Attention:

Mr. R. C. DeYoung Re: Reportable Event Operation of Reactor Core Isolation Cooling (RCIC) System Equipment Room Cooler

Dear Mr. DeYoung:

Our April 29, 1983, letter to the NRC indicated that the RCIC pump /

turbine on the Perry Nuclear Power Plant could, as presently designed, operate without adequate room cooling, since the cooling water supply to the fan coil was not automatically put in service when the RCIC turbine starts.

This item was classified as reportable under the provisions of 10 CFR Part 21, and corrective actions were initiated to automatically provide cooling water to the pump room cooling unit when the RCIC turbine starts.

Having reviewed seventeen (17) of forty-eight (48) safe shutdown systems for similar discrepancies, and finding none, Gilbert / Commonwealth has concluded that Reportable Event No. 067 was an isolated case.

Evaluation of applicability to the remaining safety related systems on the Perry Project is being assessed during the continuing process of system finalization. Any similar instances identified in this process will be corrected.

If you require any further information on this matter, please contact me at (215) 775-2600, Extension 7545.

Very truly yours, Wh

/

930630 N. R. Barker 83j7%O 0500044y Vice President and General Manager p

p h

Quality Assurance Division NRB:bmk l D cc:

H. Lorenz R. C. DeYoung - 2 L

T. M. Demers U. Potapovs - NRC Region IV Document Management Branch 525 Lancaster Avenue Readmg. PA / 000 He Avenue. Wyomissmg. PA / Morgantown Road. Green HMs. Readmg. PA 215 775-2600 209 East Washmoton Avenue. Jackson. MI 517 788-3000 / 80 Pme Street. New York. NY 212 422-3177