h /d,JJh)

Commonwr"'] Edison p

Dresden Nucteddsr Statlin

\\

RR.#1 Morris, liiinois 60450 Telephono 815/942-2920 31, 1976 [ 1

' BBS Ltr. #76-6421 August u

fREC((g9 f

SEP y IO76x ig 9.s. %

gi

{Hr.JamesG.Keppler,RegionalDirector j

y, Directorate of Regulatory Operations - Region,1,.ll.nc, c - h, (g%f

,, t,,Q

- y

=j y.;U.S. Nuclear Regulatory Commission 1

/,l/

s 4

799 Roosevelt Road 2' '

M Glen Ellyn, Illinois 60137 no p.

. m <j,

g m

u

SUBJECT:

Dresden Unit-3 Condenser Low Vacuum Scram Swltches

References:

1)

Letter to J.F. O' Leary from W.P. Wo'rden dated January 22, 1974 2)

P & ID H-346 Report Date: August 31, 1976 Occurrence Date: January' 14, 1974 INTRODUCTION Under " Corrective Action" of the Abnormal Occurrence report referenced above, it was stated that the existing Barksdale condenser low vacuum scram switches appeared to lack acceptable repeatability. To correct the problen, the Barksdale switches were to be replaced with Static-0-Ring Corporation vacuum switches which had proved to be very reliable in similar applications.

RESOLUTION After qual 1.tative testing, the proposed substitution of the Static-0-Ring

r., -

~"',.,

i

!~

switch'was'Judg'ed to be undesirable because of the, switch's seismic limita-ge 3..si t e r

tions. Furthermore, the performance of the condenser low vacuum scram switches over the intervening 34-month period indicates that the Barksdale switches have s tab i l i zed l,s igni f i can'tl y.

The maximum drift exhibited by any of these c.

i co.

,switchesovertfisperiodhasbeen0.6inHgj,whichoccurredonceonPS503C.;.a By adjusting thes'e switches ' to the Dresden setpoi.nt band of 23.7 + 0.2 in Hg,.;m 1,,a,

all setpoint variations have remained well within Technical Specification

,s, m; nc i

limits.

Since"the existing Barksdale switches on Unit-3 appear to be performing,i._<

as designed, no corrective action is deemed necessary.

- --~.

h0 -[h J'

B.B. Stephenson 8306160075 770411 Station Superintendent PDR ADOCK 05000249 S

PDR Dresden Nucicar Power Station BBS:WEil:bbc SEP 101976 COPY SENT REGION M i

~

--