COF'sJMERS POWER COMPANY MIDLAND ENERGY CENTER Transmittal No:

CSC-7734 Date: May 9, 1984

'To:

Stone & Webster P O Box 1963 EXINC.tpAL STAFF E

Midland, MI. 48640 1

p.g M FP I1

')/ PJ F

Attached Is Partial Response To pao 505 Ma h g

Complete Response To g- -

g g7 y

"NF File 4

W For Your Information Other i

==

Description:==

Tracked Information Item 075.

Signatures N [

w : m -..... - -

,~n..

JGKepp,ler g,NRC]Re3 onEI.1.IL. w/,a i

cc:

JJHarrison, NRC Region III w/a RJCook, NRC Site w/a

,pk RAWells, MPQAD

. w/a 7

6S" BHPeck, }EC w/a NIReichel, MEC. w/a DDJohnson, }EC w/a g(

/

e405210182 840509 MAY 141984 PDR ADOCK 05000329 S

PDR y.

_.,v__

_.,m.

__7

ITEM / HOLD POINT NOTIFICATION FORM Sheet 1 Of 2 HM M MER STONE & WEBSTER

E"," M ER og CONSTRUCTION IMPLEMENTATION O TR ACKED ACTION ITEM OVERVIEW G TRACKED INFORMATION ITEM N/ptANP nuclear MANT./.0. NO. /+509 0 TRACKED RECOMMENDATION ITEM 0 uNTRACKEDireu REFERENCE (S) ANSI N 45.2 SECTION 6 ASME III NF 4121 1974 Edition. ASME Codo. Casa 1651 O HOLD POINT NOTIFICATION CONDITION DETAILS Code case 1651 has been implemented by Bechtel Power for the development of certificates of compliance (Attachment No. 1).

This document certifies that the manufacture of listed component supports complies with the requirements of ASME III Subsection NF.

As listed on Attachment 1, Item 7, of DWG FSK-M2CCA-1-7-H-4 is certified by Bechtel Power as being manufactured in accordance with the specified ASME code.

This Item is a standard component support part (" material") manufactured by ITT Grinnell.

(Continued on Sheet 2)

@ YES NO'S) N NO ATTACHMENTS DATE RESPONSE REO'D.

INITIATOR /DATE INITIATION APPROVED /DATE V~ ~Vl~ O W mn SQIt h

Y~0' W c

[

RESPONSE (SEE NOTE)

V Attached Bechtel Letter BCCC-9289 dated April 30, 1984 has been reviewed by CPCo SMO and determined to provide a complete reponse to this item.

(PAGE O YES NO'S)

NO ATTACHMENTS 1

EST. CORRECTIVE ACTION RESPONDENT TITLE DATE

"" """' M y wM gr/64c,A sk/u RESPONSE ACCEPTED DATE)

RESPONSE VERIFIED / CLOSED '

D' ATE 10$7E - FOR TR ACKE0 ACTION ITEMS ONLY. EXPL AIN CLE ARLY OR REFERENCE ATTACHE #ENTS FOR:

)

1) C AUSE OF OBSERVE 0 CONDITION 2) CORRECTIVE ACTION T AKEN 3) PREVENTIVE ACTION TAKEN 500-0.09(CN)

c.__ _ _

amurww 02' ShGet 2 of 2

[a,

- 'On ' 4-12-84 ~ it' was confirmed Bechtel Power has no written approved procedure

'which defines the development or certification of the attached document.

Is-!it:'the-intention to use such certificates to denote the acceptability of ASME III materials 3 supplied by BPCo to its subcontractors? Does Bechtel Power intend to. define; development.and certification of these documents within an approved

-procedure? If so when?

4 j._

J P

l-i f

500-009(CN)

L

I@T,,f y ATTAC HmF t4T oup_7 ^

~~*

gTetA te 075 w

3-fbft;b$'dSmb;f k

Q 3Th I'.I h Yh

[1 fhihkdjs!.[b@ bat'd!1S$$(OU ff I

Certificate of Compliance j

?-

We,. Bechtel Po er Corporation, certify that the componet supports w

identified by this report have been manuf actured in accordance with Section III, Subsection NT, of the ASME Code 1974 Edition with the inclusion of Paragraph NT2610, Summer 1976 Addenda and fo:- Class 1 supports, Subarticle Nf5200 of the Winter 1978 Addenda.-

t Applicable code cases:

1 l

1644-3, 1683, 1729, 1734, 1644-5, 1644-6, 1644-7, N-10 8, 1567, 1644-9, K242-1, 1651, 1682, 1685, 1686, 1690, 1728, N-180, 1651,

[

i N-302, N-225.

i hN g

18 f [J Essponsible Representativ6

.f!#fl.

Date m

f 7

/'

MnGGR-orems osu s sgiepen ' panggs FSK-M-2ccA-to8 2.-HI ALL S7/ M; 77 Go/

ctess.t 2ccA-I-7-H4

'J"E9"7 571 Rd 63 60)

CLASS T f

I L

.(

i i

~

Bechtel Power Corporation Post Office Box 2167 Midland. Michigan 48640 April 30, 1984 Consumers Power Company P.O. Box 1963 Midland, Michigan 48640 Attention:

D. L. Quamme Site Manager 4

Midland Plant Units 1 & 2 Bechtel Job 7220 i

STONE &' WEBSTER OVERVIEW ITEM NO. 075 BCCC-9289

Dear Mr. Quamme:

This is Construction's final response to Stone & Webster's Overview Item No.-075.

~

i The 1974 Edition of Section III of the Boiler and Pressure Vessel Code, Subsection NF, paragraph 4121, requires manufacturers and installers of ASME component supports to certify that the supports-complies with the rules provided in that subsection, but does not contain requirements for the certification.

The manner in which the certification is to be pro-vided was defined later in Code Case 1651, and the attachment to Stone and Webster's CIO Item 075 is a representative example of the certificates i

being provided by Bechtel to B&W to satisfy this Code requirement. This form does not certify material in the sense that a C(rtified Material Test Report (CMTR) does, nor does it certify the material and fabrication performed by Grinnell.

It does, however, certify that all activities performed by Bechtel were in accordance with the ASME rules.

The:,3 activities include,.but are not limited to procurement (including assemblies from Grinnell), receiving and storing materials, cutting, pre-assembly, welding, NDE and shipping 1.e., The Quality Program..

Under the terms of Bechtel's contract with B&W, Bechtel is furnishing the

. supports to B&W for installation.

Some of the supports were procured by Bechtel from ITT Grinnell before 1978 and since 1978 the supports have been fabricated by Bechtel at the Standish Shop..lf a hanger item is missing from an assembly previously furnished by Grinnell, Bechtel pro-vides the item, performing fabrication as required where approved by Grinnell for Bechtel to do so.

i i

e k

D. L. Quamme Page 2 BCCC-9289 Regarding hanger number 2CCA-1-7-H4 furnished by Grinnell, Bechtel did some pre-assembly work, including welding, and on 6/15/83 delivered the hanger to B&W with all its parts except for item 7.

A certification was also provided on that date.

Item 7, which is a hunger rod, was cut to' length and threaded at the Standish Shop later.

It is a fabricated part requiring the certification per Code Case 1651 which was provided on 10/5/83.

Bechtel furnishes bulk quantities of material that are not designated for a particular hanger assembly in accordance with paragraph 4323 of the Bechtel Quality Assurance Manual.

In B&W's case, the Quality Records for bulk material procured by Bechtel and the records furnished by Grinnell for hanger assemblies are maintained in the Jobsite QC Vault and made available to B&W.

Reference B&W's letter of 3/12/84 to Bechtel, copy attached, agreeing with this arrangement.

The following are our responses to the specific questions asked by Stone and Webster.

l 1

Q-is it the intention to use such certificates to denote acceptability of ASME III materials supplied by BPC to its Subcontractors?

A-the certification being provided per Code Case 1651 applies to component supports only and is furnished only when Bechtel provides material which is unique to a designated hanger assembly.

Materials provided in bulk quantities are furnished in accordance with paragraph 4323 of the BQAM and the letter of 3/12/84 from B&W which allows the quality records to be maintained in the QC Vault.

Q-does Bechtel Power-intend to define development and certification of these documents within an approved procedure?

If so, when?

A-Bechtel is preparing a procedure for providing hanger certifications per Code Case 1651 which will complement the N-5 Data Reports.

The certification being provided to B&W will also be addressed in that procedure which is currently scheduled to be issued by 8/1/84.

If you have any questions, please contact John Russell at extension 7594.

Very truly yours, 5

G. A. Hi Site Man er GAH/JER/ajd

..r Attachments:

1)

B&W Letter M-1A(Q)-376 dated 3/12/84 2)

Bechtel Letter BCBW-29 dated 2/17/84 cc:

N. Reichel

__.______m_____

\\

\\

a Babcock & Wilc:x sar c nn.c comp.,

Cop ey a McDermott company (216) 606-8841 March 12,1954 TI) k Bechtel Power Corporation Tf g P.O. Box 2167

Subject:

Subcontract 7220-M-1A NSSS Erection Midland, MI 486A0 Provisions of Records for D '

ASME Syst9.ms Attn: Mr. G. A. Hierzer Serial:

M-1A-(Q)-376 REF:

BCBW-29 dated 2-17-84

Dear Mr. Hierzer:

B&W Construction Company concurs with Bechtel that Bechtel's Q.C. Vault is an acceptable " records retention location" as long as Bechtel can provide the Quality Assurance Records that we request in a timely manner.

Under these conditions, we foresee no problem.

if you have further questions regarding this matter, please contact me.

Respectfully, N 1 8t<_,

S. L. Taulbee Fielo 0.C. Supervisor sk-9w V. N. Asgaonkar Project Engineer cc:

R. P. Estlack H. R. Krause A. W. DePatie K. Pulito C. D. Thompson File 1

+r p

Escne:.3Cwer Corporation f

.i Des: Ctf.ce liion 2167 Mic'anc M 09.gan 48640 February 17, 1984 B&W Construction Conpany P.O. Box 1984 Midland, MI 48640 Attention Vas Asgeankar Midland Plant Units 1 & 2 Bechtel Job 7220 PROVISION OF RECORDS FOR ASME SYSTEMS BCBW-29 Dear Mr. Asgoankar ne 3echtel Quality Assurance Manual (BQAM) requires char Bechtel provide to B&W Construction certain records generated by our procure =ent and receiving inspection activities.

These records include (tut are not limited to) CMTRs, =aterial requisitions, and receipt l-inspection records.

BQAM paragraph 4323 vill also require that 3echtel provide these documents ~at a records retention location mutually agreed upon by Bechtel and the Certificate Helder receiving the caterial."

(

his letter is written to inform you that these docu=ents are ;iresently being stored in the QC Vault, located in the Main Office Building. 3&W l

personnel have been granted the sane rights to access this vault as l-have 3echtel personnel.

Bechtel requests your concurrence that the use of the QC Vault as a

" records retention location" is acceptable to B&W Construction.

Please respond by March 1, 1984..

Very truly yours,

\\

3 d4.Aan G. A. Ely ztr Site Ma QCAH/lAs/jke 021402T3 4

Written Response Required:

Yes l

Cate Response Raquired:

March 1, 1984 l

i l_

tc:

D. Short (site)

M. ;ietri-h (site)

K. Pulito (site)

M. Plu=5 (site)

R. Estlack (site)

J. Jarbee (3FEO)

(