Text
,
Florida Power CORPORATION oyennt aver una a DodetNo.80302 May 31, 1995 3F0595-07 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555
Subject:
Once Through Steam Generator Inspection, Technical Specification Twelve-Month Report
Reference:
A. FPC to NRC letter, 3F0594-01, dated May 25, 1994 B. FPC to NRC letter, 3F1194-10, dated November 30, 1994
Dear Sir:
Florida Power Corporation (FPC)is hereby providing the complete results of the Once Through Steam Generators (OTSGs) inspection performed during our Refuel Outage 9 (Spring 1994) as well as a final version of the report, " Evaluation of Crystal River 3 Pulled Steam Generator Tubes," we provided to you in Reference B.
The special report is provided in accordance with Technical Specification 5.7.2.c.
The report contains the following information:
1.
Number and extent of tubes inspected, 2.
Location and percent of wall-thickness penetration for each indication of an imperfection, and 3.
Identification of tubes plugged and tubes sleeved.
The information contained in the attached 12-month report supersedes information previously provided in Reference A pertaining to the items listed above.
9506070239 950531 PDR ADOCK 05000302 0
PDR CRYSTAL RVER ENERGY COMPLEX 15760 W. Power une Street. Crysted FUvor. Flonda 3442S6708. (904) 7954486 A Flanda Progress Compvry
U. S. Nuclear Regulatory Commission 3F0595-07 Page 2 The final version of the report provided in Reference B replaces the earlier version with change bars noting any actual changes made.
This report is consistent with the technical bases provided in support of TSCRN 203, Revision 0 but addresses the tube pull results more broadly.
Sincerely, G. L.
- oldt, Vice President Nuclear Production GL8:LVC Attachment Regional Administrator, Region 11 xc:
Senior Resident inspector NRR Project Manager
,