CD

/ l v

O I

5'O - 2'5 4 0+

, US AEC 'HOS GTWN ffi bhlM5!5b

~f h

'JW Ilh Liu o lMjhdM 4 l!,;u v

'WU WSH TLX A194

_ AC150( 1557 )( 2-03188 5E135)PD 05/15/74 1553. lR.'

t

'c W

ICS IPM8NGZ CSP g [ g f' q

3096542241 TOBN CORDOVA IL 135 05-15 0357P EDT WW1619p#w s

R4S JOHN F O' LEARY, DI REC TOR, DLR 7

C 9

5.:.O WIG-DIRECTORATE OF LICENSING REbOLATION US ATOMIC lN5RGY COMMISSION 9fw; aaY

/

WASHINGTON 'DC 20 545 o/

6,/{

(

REFERENCE:

QUAD-CITIES NUCLEAR POWER STATION UNIT 1,

DOCKET N14 DER 50-254, DPR-29, APPENDIX A, SECTIONS 1 0A.4i 1 0 A. 5, 6 6 8 1. A, 34.A TABLE 3.7 1 ON MAY I 4, 1974, WITH UNIT 1 IN THE ' COLD SHUT DOWN CONDITION DURING THE REFUELING OUTAGE, SURVEILLANC E TESTING REVEALED THE FOLLCAING:

1. SBLC RELEASE VALVE l-1105A 0'ERATED AT 165D PSIG, THUS EXCEEDING TECHNICAL SPECIFICATIONS.

THE RELEASE VALVE WILL BE READJUSTED AND TESTED TO BE WITHIN 4

SPEC IF IC ATI ONS.

2.

NITROGEN PURGE VALVE A0-1-16PI-55 REGUIRED 39 SECONDS TO CLOSE, THUS EXCEEDING TECHNICAL SPECIFICATION 3 7. D.1.

3. DRYWELL PURGE VALVE A0-1-l60.1-21 REGUIRED 13 I/2 i ~ ' SECONDS CLOSING TIME, THUS EXCEEDING TECHNICAL SPECIFICATION

~ 3 7.D. I.

THESE VALVES WILL BE REPAIRED AND RETESTED TO BE WITHIN

' SPEC IF I C AT I ONS. DETAILS OF THESE INCIDENTS WILL BE REPORTED i

_ IN LETTER WITHIN TEN DAYS VERY TRULY YOURS COMMONWEALTH EDISON CO GUAD-CITIES NUCLEAR POWER STATIONN J KALIVI ANAMIS STATION SUPERINTENDENT N4NN h

O

</,f 3 l.

s i

625PIDT+

M

/

USAEC HQS GTWN.

'i ff t

t t

COPY SENT REGION jf