i I

CAROLINA POWER & LIGHT COMPANY BRUNSWICK STEAM ELECTRIC PLANT l

BRUNSWICK RESPONSE TO NUREG 737 SUPPLEMENT 1 -

  • REGULATORY GUIDE 1.97 - APPLICATION TO EMERGENCY  ;

RESPONSE FACILITIES DATE: [/f 77

/f ^

SUBMITTED BY: M((h MM l,M RECOMMENDED BY: g[ _ __

APPROVED BY:

z.

7 REV. NO. SUBMITTED BY RECOMMENDED BY

  • APPROVED BY DATE 1

hd ,]$ m )}l /lJfg 2 Jua aw wM- 'b/dd 7

'Se+ + -

i 8405140174 840508 PDR ADOCK 05000324 p PDR

LIST OF EFFECTIVE PAGES -

Brunswick Response *to IMREG 737 Supple:nent 1 - Regulatory Guide o

1.97 - Application to Emergency Response Facilities

~

Page(s) '

Revision 1-iv 1 1-11 , 1 .

12 2'

'13-21 1 22-23 2 24-58 1 59

  • 2 60-61 -

1 62 -

2 63-64 1 .

65-67 2 68-69 , 1 72 2

~

73 1 e

iv Rev. 2 e

S e

.=___ - - _ - . _ - . _ _ _ _ _ - .-____ _ _ _ _ _ _ _ _ - _ _ _ _ _ - _ _ _ - - _ _ _ _

. . s' ,

  • VARIABLE B3 - RCS SOLUBLE BORON CONCENTRATION (Sample)

Recommended By RG 1.97 Provided by Brunswick (a) Instrument Range 0-1000 ppm Range exceeds RC 1.97 Recommendation ,

\

(b) Environmental Qualification No specific position - Sampling System will be qualified. Analysis equipment is high quality commercial.

.(c) Seismic Qualification No specific position Sampling system will be seismically qualified.

Analysis equipment has not been qualified.

Sampling System has full QA Program commitment.

(d) -Quality Assurance High Quality Commercial Grade Analysis equipment is high quality commercial grade. .

(e) Power Supply Non-1E lE for PASS, Conventional for analysis. l (f) Redundance & Sensor No Redundant Sample Points only Location RCS Samples are taken from the RHR Heat Exchanger A and B shell sides and from the No. 6 and No. 14 jet pumps.

(g) , Location of Display ,

1 l

The sample will be analyzed on site in the chemistry lab located in the service building. Back up analysis will be performed by Babcock and Wilcox. Boron concentration is logged by the laboratory technician

! and phoned in to the TSC. , l

. (h) Schedule l- TML modifications80-028 and 80-029 have provided this Post Accident Sampling System.

=l 1

, 12 Rev. 2 4

.-- , _ _. _ , . - . . _ --...#___ .-. .. - - _ . , , _ _ _ _ . - - r .,

s' ,

VARI ABLE C1 - RADIOACTIVITY CONCENTRATION OR RADIATION LEVEL IN CIRCULATINC PRIMARY CDOLANT Recommended by RC 1.97 Provided by Brunswick (a) Instrument Range 1/2 Tech. Spec. Limit Brunswick meets required range to 100 Times Tech Spec.

Limit (b) Environmental Qualification Yes Yes (Sampling System)

(c) Seismic Qualification Yes Yes (Sampling System)

(d) Quality Assurance Yes Yes (Sampling System)

(e) Power Supply lE lE (Sampling System)

(f) Redundance & Sensor Location Yes Yes Primary coolant samples are taken from.the Reactor Water Cleanup System during normal operation and analyzed at the counting room by a Cainma Spectroscopy System. During accident situations, Primary Coolant samples are taken by the Post Accident Sampling System located outside the Reactor Building. The sample is analyzed in the counting room. Results are ' phoned in to the TSC.

(g) Location of Display - Counting Room *

(h) Schedule - TMI Plant Modifications80-028 and 80-029 have provided the POST ACCIDENT SAMPLINC SYSTEM for Unit 1 and 2 respectively.

. 22 Rev. 2 e

4 Oc

VARIABLE C2 ANALYSIS OF PRIMARY COOLANT (CAMMA SPECTRUM) -

, Recommended by -

RG 1.97 Provided by Brunswick (a) Instrument Range 10 Ci/gm to 10 Ci/gm or TID-14844 Source Term in Coolaht Volume Brunswick meets required range r (b) Environmental Qualification No Yes (Sampling System)

(c) Seismic Qualification' - No Yes (Sampling System)

(d) Quality Assurance 111gh Quality Commercial Yes (Sampling Systen.)

Crade (e) Power Supply Non-lE lE (Sampling System) .

} (f) liedundance & Sensor Loc'ation No Yes Primary coolant samples are taken from the Reactor Water Cleanup System during normal operation and analyzed at Coolant the Counting Room by a Camma Spectroscopy System. During accident situations Primary samples are taken by the Post Accident Sampling System located outside the Reactor Building.

The sample is analyzed in the Counting Room. Results are phoned in to the TSG.

(g) Location of Display - Counting Room

, s s

(h) Schedule '

- TM1 Plant Modifi ations80-028 and 802029 h' ave provided the Post Accident Sampling System for Unit I and 2, respectively.

e 23 Rev. 2 v.. , . , . . - .- . , , _ , - - - , , - , ,

VARIABLE E2 - Reactor Building or Secondary -

High range monitoring of this variable is not.

Containment Area Radiation required for Brunswick. The Reactor Building vent is closed when the radiation level reaches 11'ar/hr and secondary containment atmosphere is l routed through the standby gas treatment system.

See Brunswick position paper.

I 4

4 e

t 4

59 Rev. 2 a

e I

e

, . . ___ _1_ . ___ . . _ . . .- _ _ _ - - - _ _-_. _ _ - - _ _ . _ ,

,4 VARIABLE E4, ES .

, Recommended by RG 1.97 Provided by Brunswick (c) Seismic Qualification . No .

'(d) Quality Assurance Not Required See. Note 2 (e) Power Supply -

High Reliability liigh Reliability (f) Redundance & Sensor Location No Partially as shown below Sensor Tag No. Range Location Function Radiation Detection D12-RE-4561 liigh IR-TB-31 TB Vent Rad Mon D12-RE-4562 Mid "

D12-RE-4563 Low "

D12-RE-4573 Illgh OG Stack Rad Mon D12-RE-4574 Mid D12-RE-4982 Low Flow Transmitter VA-FT-3358 0-15000 SCFM Local 1brbine Vent Flow Transmitter VA-FT-3359 0-100,000 SCFM Local Plant Stack (g) Location of Display Display Tag No. Range Location Service

- i Recorder D12-RR-4548-1 10- to 10 , uC1/cc XU-75 Control Room TB Vent Rad Mon Recorder D12-RR-4548-2 10 to 10 "

XU-75 Control Room "

Recorder -I D12-RR-4548-3 10 to 10 " " "

Effluent Recorder D12-RR-4549 10-1 u 19 - 13 n n n Radiation Recorder' D12-RR-4599-1 10- to 10 -I "

XX-79 Control Room OG Stack Rad Mon Radiation Recorder D12-RR-4599-2 10 -0 to 10- " "

Radiation Recorder D12-RR-4599-3* 10 -I " "

Effluent Recorder D12-RR-4600 to If 10 to 10 uCi/Sec "

62 Rev. 2

,--,,,,-,e - , ,n , _w - - _ - m r e .-r-- ,, -- - - +

I g VARIABLE E7 AIRBORNE RADI0 HALOGENS AND PARTICULATES (Portable Sampling with onsite analysis capability)'

Recommended by RG 1.97 Provided by Brunswick

-9 (a) Instrument Range 10 Ci/cc to 10 -3 C1/cc 10-I' Ci/cc to 10-2 Ci/cc (b) Environmental Qualification No specific provision No ,

(c) Seismic Qualification No specific provision No

'(d) Quality Assurance iiigh Quality Commercial Grade High Quality Commercial Grade .

(e) Power Supply No specific provision -

(f) Redundance & Sensor Location Not Required Yes Item Range Location Gamma Spectroscopy System 11714 C1/cc to 10- Ci/cc Counting Room Mobile Station (offsite environs analysis)

(g) Location of Display Counting Room (h) Schedule No changes are required.

=

65 Rev. 2

VARIABLE E8 PLANT AND ENVIRONS RADIATION (PORTABLE INSTRilMENTATION)

Recommended by RG 1.97 Provided By Brunswick (a) Instrument Range Photons 4 10 R/hr to 10 R/hr Beta & low energy photons (b) Environmental Qualification No specific provisions -

(c) Seismic Qualification No specific provisions -

(d) Quality Assurance liigh Quality Commercial liigh Quality Commercial Grade Grade (e) Power. Supply No specific, provision Battery Powered (f) Redundance & Sensor Location ,

Not Required Yes - Multiple units provided Item Quantity Range Measurement Location E-520 50 0 R/hr 2 R/hr Photons Service Bldg.

E-400 l

. 6 0 200 mr/hr Photons " "

Minirad 28 0 5 R/hr Photons " "

PIC-6A 30 " "

0- g000R/hr Photons

  • PRM7 6 10 R/hr - 5x10' R/hr Photons " "

Ro-7 2 0 - 20,000 R/hr Photons, beta & low " ~"

energy photons Ro-2 20 0 - 5 R/hr Beta & low energy photons " "

Teletektor 35 0 - 1000 R/hr Photons " "

Ro-2A 15 0- 50 R/hr Beta & low energy photons " "

(g) Location of Display - Display is integral part of portable instrument.

(h) Schedule - No changes required.

\

66 Rev. 2 e e

VARIABLE E9 Plant and Environs Radioactivity (Portable Instrumentation)

Recommended by Provided by Brunswick RC 1.97 a) Instrument Range Multichannel Camma Ray Multichannel Camma Spectrometer Ray Spectrometer b) Environmental Qualification No specific provision -

c) -Seismic Qualification No specific provision -

d) Quality Assurance , liigh Quality liigh Quality Commercial Crade Commercial Grade i

e) Power Supply No specific provision -

f) Redundance & Sensor Location Not Required Yes Multichannel Camma Spectrometer located in Counting Room and Mobile Lab.

l g) Location of Display - Display is integral part of portable instrument.

h) Schedule - No changes are required l

67 Rev. 2 9

s

't VARIABI.E E13 Primary Coolant and Sump (ANALYSIS CAPABILITY ON SITE)

  • Recommended by RC 1.9 Provided by Brunswick a), Instrument Range Cross Activity 10 uCi/ml to 10 C1/ml Camma Spectrum 1 uC1/ml to 10 uCi/ml Isotopic Analysis Isotopic Analysis Boron Content 0 to 1000 ppm 20 to 6000 ppm -

Chloride Content 0 to 20 ppm . 0.5 to 20 ppm Dissolved llydrogen or Total Gas 0 to 2000 cc (STP)/Kg Open item awaiting Dissolved Oxygen 0 to 20 ppm resolution by CE pil 1 to 13 1 to 14 b) Environmental Qualification No specific provision Sampling System will be -

qualified. Analysis equip- ,

ment is high quality commercial, c) Seismic Qualification . No specific provision Sampling System will be seismically qualified.

Analysis equipment has not j been qualified, d) Quality Assurance liigh Quality Commercial Sampling System has full QA Crade Program commitment. Analysis

, equipment is high quality commercial grade. <

e 4

+

70 Rev. 2

e

. \. . .

VARIABLE E13 (Continued)~ - -

Recommended by RC 1.97 Provided by' Brunswick .

.. (e) Power Supply' ENo specific provision Sampling System will be IE power.

Analysis equipment is powered from conventional sources:

(f) Redundance & Sensor Location Redundancy not req Ired ,

, The Post Accident ' Sampling System allows samples of primary coolant to be taken from a remote station in the Turbine Building breezeway. Analyzing equipment is located as follows:

Gross Activity and Gamma Spectrum Counting Room.

Chemical Analysis Chemistry Lab (f) Location of Display The chemistry analysis is made in the Chemistry Lab and the results logged. Cross activity j

and gamma spectrum displays are available in the Counting Room.

(h) Schedule: TMI Plant Modifications 80028 and 80029 have provided the Post Accident Sampling System for Unit I and 2, respectively.

1 e

71 ,

Rev. 2

-g , , -- - n ---- -

e

,  : 9 's t "

f VARIABLE E14 - Containment Air RecommendedbyRG1.9h Provided by Brunswick (a) Instrument Range '

l

. ,llydrogen Content 0 to 30% . I to 30% l 0xygen content 0 to 30% 1 to 30%

Camma Spectrum (Isotopic Analysis) Isotopic Analysis (b) Environmental Qualification , No specific provision Sampling System will be environmentally quali-

, fled. Analysis equipment' is high quality commercial.

(c) Seismic Qualification -

No specific provision Sampling System will be seismically qualified.

Analysis equipment has not been qualified. .

(d) Quality Assurance High Quality Commercial Brunswick.QA program Crade applies to the sampling system. Analysis equipment is high quality commercial grade.

(e) Power Supply No specific provision Sampling System will be IE power. Analysis equipment is powered

, from conventional sources.

e

. '72 Rev. 2

n. , -

, 7-. - - - . ---