9
(
,h t
Arizona Public Service Company d3 En 27 r;; p :
. Gi April 24, 1984 ANPP-29349-BSK/TRB U. S. Nuclear Regulatory Commission Region V Creekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek, California 94596-5368 Attention: Mr. T. W. Bishop, Director Division of Resident Reactor Projects and Engineering Programs
Subject:
Deficiency Evaluation Report DER 84-17 A 50.55(e) Evaluation Relating To The Core Shroud Envelope File: 84-019-026; D.4.33.2
Reference:
Telephone Conversation between P. Narbut and T. Bradish on March 26, 1984
Dear Sir:
The NRC was notified of the subject Deficiency Evaluation in the referenced telephone conversation, with a determination of reportability to be made within thirty (30) days (April 25, 1984).
The deficiency has subsequently been determined to be Not Reportable under the requirements of 10CFR50.55(e), therefore no written report is required. Necessary documentation of the evaluation will be maintained in APS files.
Very truly yours,
(.
t C
C.
cm nev-p E. E. Van Brunt, Jr.
APS Vice President, Nuclear ANPP Project Director EEVB/TRB:db cc: See Page Two 5090148 840424 DR ADOCK 05000528
/[r-g }_ I Q 8
,.- -.6 Mr. T.
W.' Bishop AlfP-29349 -
.Page Two cc:
Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 T. G. Woods, Jr.
D. B. Karner W. E. Ide D. B. Fasnacht A. C. Rogers B. S. Kaplan L. A. Souza D. E. Fowler J. Vorees J. R. Bynum J. M. Allen P. P. Klute A. C. Gehr W. J. Stubblefield W. G. Bingham R. t.. Patterson R. W. Welcher H. D. Foster D. R. Hawkinson L. E. Vorderbrueggen
. G. A. Fiore111 S. R. Frost J. Self D. Canady Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, CA 30339 i
1 4
-