ML20084D886

From kanterella
Jump to navigation Jump to search
Ro:On 730320,radwaste Waste Surge Tank Radioactivity Exceeded Tech Spec Limits.Caused by Water Transfer from Waste Collector Tank W/O Decontamination Factor Provided by Filter & Demineralizer Which Were Taken Out of Svc
ML20084D886
Person / Time
Site: Dresden  
Issue date: 03/29/1973
From: Worden W
COMMONWEALTH EDISON CO.
To: Anthony Giambusso
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20084D704 List:
References
2145, 244-73, NUDOCS 8304120645
Download: ML20084D886 (2)


Text

r m

Ns

(

50-237

~

50-249 Commonwealth Edison Company 72 WEST ADAMS STREET

  • CHICAGO. ILLINOle Addrean Eeoly tes POST OFFICE toX F 4 7
  • C H IC A G O, I L L I M O IS 40 4 9 0 WPW Ltr.#244-73 Dresden Nuclear Power Station R. R. #1 ppf j m

Morris, Illinois 60450

.b March 29, 1973 D

z

.~.;l i:

J

.. LU &g.,

(

?'

. s.

14.x -

Mr. A. Giambusso

\\

4g f.g. 4 Deputy Director for Reactor Projects 7

Qp \\g['

Directorate of Licensing

'tr p

U. S. Atomic Energy Commission

,/g Washington, D. C.

20545 s

!':)-

F SUMECT:

LICENSE DPR 19-25, DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3

[' -

SECTION 6.6.B.3 CF THE TECHNICAL SPECIFICATIONS.

Qa

Dear Mr. Giambusso:

}pi2 f

j~

This is to report a condition relating to the operation of the (r

station in which on March 20, 1973, the Radwaste Waste Surge Tank was 3

(Dl' found to contain 5.6 curies which exceeds the Technical Specification limit as stated in Section 3.8.D.

PROBLEM AND INVESTIGATION The following circumstances led to the Waste Surge Tank content of 5.6 curies:

"A" waste collector filter had been taken out-of-service on March 13, 1973 due to suspected crud leaks in the filter septums. On March 19, 1973 at 2110, "B" waste collector filter and the Radwaste demin-eralizer were taken out-of-service due to high differential pressure across the filter. Steam cleaning of "B" filter was required. Also at 2110 the water level in the Waste Collector Tank reached 80 percent and continued increasing.

In order to decrease tank level, water from the Waste Collector Tank was transferred to the Waste Surge Tank without the decontamination factor provided by the filter and demineralizer.

\\.~ q $q y

n(

/

8304120645 }3 g g gDRAEK PDR

<s.15

Mr. A. Giambu a March 29, 1973 At 0015 on March 20, 1973, the Waste Surge Tank was placed on recirculation for a sample. At 0130 hours0.0015 days <br />0.0361 hours <br />2.149471e-4 weeks <br />4.9465e-5 months <br />, a sample from the Waste Surge Tank was taken and the analysis indicated 4.3x107 uuCi/1'and a tank curie content of 5.6 curies.

Initial action taken to eliminate the problem consisted of steam cleaning of "B" Waste Collector Filter and placing the filter and demineralizer back in service. At 0926 on March 20, 1973, the Waste Surge Tank was processed through the filter and demineralizer to "C"

Waste Sample Tank. Sample results from "C" Waste Sample Tank at 1400 hours0.0162 days <br />0.389 hours <br />0.00231 weeks <br />5.327e-4 months <br /> indicated the tank curie content was below Technical Specification limits.

The presence of 5.6 curies of S r radioactivity in the water in the above ground tanks did not present a hazard to the public since the contents of the tank were not released to the river and the tank S tradioactivity was reduced to less than Technical Specification ibnits within 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> following collection and analysis of the first sample. Had a failure of the Waste Surge Tank occurred, as described in Admendment #9,Section V.C.1 of the S.A.R., and the radioactivity contained in the tank been released to the aquatic environment, the Ibnits as specified in 10 CFR 20.106 would not have been exceeded when averaged over one year.

i CORRECTIVE ACTION In order to minimize the potential for future incidents of this nature, a procedure will be issued by April 3, 1973, requiring sample analysis and calculations of curie content prior to processing the Waste Collector Tank to above ground radwaste storage tanks without the use of either a Waste Collector Filter or the Radwaste Demineralizer.

Sincerely,

b. 0 W. P. Worden Superintendent WPW:do l

(

.