TENNESSEE VALLEY AUTHORITY

+

CH ATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II April 24,1984 Director of Nuclear Reactor Regulation Attention: ' Ms. E. Adensam, Chief Licensing Branch No. 4 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Ms. Adensam:

In the Matter of

)

Docket Nos. 50-328 Tennessee Valley Authority

)

As required by the Sequoyah Nuclear Plant, unit 2 technical specification 4.4.5.5, enclosed are the results of the steam generator tube inservice inspection performed on unit 2.

If you have any questions concerning this matter, please get in touch with Jerry Wills at FTS 858-2683 Very truly yours, TENNESSEE VALLEY AUTHORITY b.

L. M. Mills', Manager Nuclear Licensing

, Sworn t.

subscr bed b fore me this day of 1984-Aaa9A "MW12 Notary Public j

g My Commission Expires /

~M Enclosure cc: _ U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

-L.

gDRADOCK05000h2u pk-8404270217 8404 4 7

PDR 8

ll 1

v.

1983-TVA 5OTH ANNIVERSARY '

An Equal Opportunity Employer a.