January 20, 1983

{n

=,

U. S. NRC l

Div. of Operating Reactors

$g g '

Attn: Robert A. Clark, Chief To.*

Washington, DC 20555

.t From:

Supervisor - Emergency Planning Energency Response Plan Implementation Procedures attached are for 9

inclusion in your manual. PIcase incorporate these changes and return this form, signed and dated.

Procedure 3.2 Revision 8 Change 1 New page 3.2-2 & 3.2 Review / Approval Page Procedure 4.1.5 Revision 8 Change 1 New page 4.1.5-6 & 4.1.5 Review / Approval Page j

Procedure 4.1.17 Revision 9 Complete:

Procedure 4.5.1.1 Cancel Procedure 4.5.1.2 Cancel Procedure 4.5.l.3 Cancel Procedure:4.10.

Cancel Appendix A.4 Revision 10 Complete Appendix B.1 Revision 9 Complete Appendix D.1 Cancel Appendix D.2 Cancel Appendix D.3 Cancel 1 have incorporated the above listed Emergency Response Plan Implementation Procedures into my manual.

Signed Date j pgg2ggggoggggg; Koor F

- ~w t,

a/

,,a ERPIP NO.: 3.2 / R EV. 3 DATE: Octccer 2,1931 i

()_

IITLE: IMMEDIATE AC" TION - LNG CONTINGENCY 4

RESPONSIBLE INDIVID U AL: STE EMERGENCY CCORDINATOR

=,

1.0 Use the Cove hint hot line and visual and instrument indicaters to determine details of spill, then record:

1.,1 Location of spill and/or initial distance in miles frem Calvert Cliffs Nuclear Power Plant intake struc. ace:

degrees miles 3

3 1.2 Potentia! size of spill (number of m ce rumber of 23,000 m

~

tanks):

~

l

.l.3 Time of spill:

(2ts hour clock)

~

i 1.4 Wind speed at the spilllocatier:

mph j

Wind direction at the spill location:

degrees Wind spee ensite (125 foot level of Met Tower' mph 3

i 3

Wind direction ensite:

degrees Data Determined and Recorded:

/

> 73 Initials.

Eme w

I

-NO TE-

}

COMPLETE ADDITIONAL STEPS IN THIS PRCCEDURE ONLY !? SP!LL IS FRCM A TANKER AND ONLY IF WIND DIRECT *ON AND SPEED INDICAT". A POSSBLE THREAT TO CCNPP. IF NO THREAT IS APPARENT, CONTINUE TO MONITOR ONLY.

2.0 Plot tne spill informacien on EXHIBIT 3.2-A, LNG SPILL INFORM ATION M AP.

Inf ormation ?!ctted:

/

In:t ais Time l

3.0 Using the LNG ACTION C ATECORIES.(EXHIBIT 3.2-B), catential spill size anc initial spill distance, determine the initial Action Category.

l Acticn Categcry Determined (cneck ene):

( )

LNG Notificaticn

( )

LNG Alert

( )

LNG Emergency

.~;d

( )

Ncne T

'n Tme ftigfg~iggI E'X5S5%

3.2-t

-ce i

-. _., _ _ _.. ~

y.,.gg

.g.7p

L ER FIP NO.: 3.2 '/ R E.V. Q ',,,

GA:sGE 1

't O

-NO TE-

~

Wind speed and direction information may be used to modify these Action Categcries

)

-r af ter a careful, censervative assessment by the Shift Supervisce or higher authori:y.

, 4.0 Sound a J second burst of the emergency alarm.

[

Notify personnei over P.A. System:

)

a. "AN LNG NOTIFIC ATION EXISTS."
5. " AN LNG ALERT EXIST 5."

ce

c. " AN LNG SITE EMERGENCY EXISTS."

_4

d. Give specific instructions (See ncte below).

[

If a drili, state "TrilS S A ORILL."

~ "

-NO TE-When removal of personnel frem the affected area is necessary announce:

3

" ALL PERSONN EL IMMEDIATELY LEAVE THIS AREA

[

(Be specific as to tne area to be vacatec. Avoid using tne :erm evs.cua:e.)

"REPCRT TO YCUR ASSEMBLY AREA."

,y.-

t-

. ~

" Extinguish all smoking materials and cpen flames."

Repeat this step again.

Emergency Alarm Scundec and Message Announced and Repeated:

/

Int::als Time 5.0 Ccmplete accre::riate LNG Category Actions:

5.1 If an LNG Notification exists, ccmolete tne L.NC Categerv A actions lis ec en

]

Exhibits 3.2-C through 3.2 7.

lGi o

3.2 If an LNG Mer: exists, ccmplete :he LNG Cateterv A and B ac-ions '.isted on Exhibits 3.2-C :hrough 3.2 7 3.3

[I an LNG Site Emer<ency exists, complete :he LNG C2:egerv A. B and C actions listed en Exnibits 3.2.C :nrough 3.2- ?.

G :.

Jt il R.,

intus:s Time 3j

6.0 'mplemen

ER?!? 3.1, Stecs 2 :necugh 5, if net previcusly accressec.

d a

,I

.?

1 3.2-2 l,,,,.p.,y-..-----,

- ~~m

-,7.y y -z.,

--n-

i b

q 1

e

. ?

\\

O ERP!P 3.2 REY!E7/APPROYAL q

t I

hEVISION CHANGE REVIEWER SIG/

SUPERVISOR POSRC' PLANT SUPERINTENDENT D, ATE t'.

EFU SIC /DATE MTG

/OATE e

Y l

?.:,hI.d$8 b m A- / V.?3 5'3 C [

l.,,ox) /bslF2

)

)

/

/ 1

/

.m.

5 6e I

?

'A r

f

(

l I

c 6

h I

I l

l l

I i

l I

i l

l r

i l

I..

l.. _ _ _. _.

I.

_. -_ -..~, m

-_-,,.7,77, pyg y.- ;7 qggggggqra

L IR?'? 3,2.-

r RE7. 8 Change 1 s

CAL 7ERT CI.~775 NCCI. EAR PC'G ? LUC

)

IMERGENCY RESPONSE PLLN 1

DGI.EMENTATICN PROCEDL RIS LIST OF rstr.C m E PAGES 3

ERPI? PAGE RE7.

3.2-1 3

3.2-2' S Change 1

~

~

3.2-3 2

1 e

3.2-4 2

3.2-3 2

. 1, Jj 3.2-6 2

3.2-7 2

]

3.2-8 2

N

..j t

.2-]

ls

~

t i

e h

.i y' '

.a i

'l

, 2, y

4 w.

.m.,w-e, nn..

,,+n.

-.m.,,.-

.s.-

..n.

. n,,.n.n,,.

4 ERP!P NO.: k.1.5 / R EV. 6 DATE: Ncvemoer 16,1981 i

    • f 3M Soit Cap Other 3'.'9. 3 Personnel Monitcring and Survey Instrum entation TLD and SRO High Range SRD (0-5R, 0-ICR,0- 100R,0-200R)

Special (RCP }-303 4.5)

Gamma Exposure Rate Meter (0.1 R/h to 20 KR/h)

' Neutron REM-Ball Neutron Dosimeter Alarming Dosimeter (0-200R)

Pcrtable Air Samplers (4 h power supply - minimum)

Team Memoers Equipped:

/

Initials Time

-NO TE-Assign asks to the Emergency Radiation Teams in accordance with the pricrity list EXHIBIT 4.1.5-A. Record all assigned tasks en EXHIBIT 5.2-A, EM ER GENCY ACEO NS FC RM.

, ~,

,j 3.10

!! the nature of gaseous release incicates the potential f cr significant levels s

of iodine (greater than 20 MPC-n of ex::csure is cossible), consicer immediate administratien of racicorotect:ve dr' gs to all aff ected onsite emergency personnel in acc::rcance witn ERPIP 2.5.3.! if adequate resciratory protect:en devices are rot availacle.

3. ! !

If a release of airocrne racioacuvity is detected, imrnediately ciscaten at l

least ene Onsi e Monitcring Team in ac::orosnce witn ERPIP 3.3.2.

i ER PIP 4.3.2 Initiated:

/

Intuais Time

-NO TE-t

!! a elease of racicactivity is cetected, Ine only delay allowee for the Onsite Monitcring Teams is an cperational cned< of exposure rate meters wnicn

~

should take 2 minutes at most.

3.l2 Have radiatten surveys pertcrmed in Assemoiy Areas ard around Ine Protected Area Fr.ce.

3.12.1 Record results on EXHISIT 5.2-A, EM ERCE.NcY ACECNS CR \\i.

l O

a.i. y 1

I l

.,.y_

.- 43...

. ~...

,, 7 -.c

~

7.-

p-- 3 -..

i i

ERPIP NO.: 4 1.5 / REV., S f

i C'D.5GE 1.

f h

I I

i 3.12.2 Notify PS of the results.

Surveys Performed and Results

/

E f

Reported to PS:

Initials Time f

3.D Establis'h control points as necessary.

cs

/'

u.

~

[

3.13.1 Record access control point locations en EXHIBIT 3.2-A.

i 3.13.2 Report results to the PS.

I Access Control Points Established and PS l

i Notified:

/

Imtlals Time

, 3.14 Have gaseous and, air particulate samples analyzed per ERPIP 4.3.2.

p 3.14.1 Record resuits on EXHIBIT 3.2-A.

}

3.14.2 Notify PS of the results.

1 i

Samples Analyzed & Results

/

l.

I Reported to PS:

-Initials Time j

t

[

3.13 Notify RAD of air sampling resuits obtained inplant and onsite.

i i

/

h.' _

Init:als Time 3.16 Restrict access into Auxiliary Building or other potential high Radiation Areas by unauthorized or unprecared individuals to hazardous radiatien environment.

j 3.16.1 Establish positive access control by instituting the use of Emergency Work Permits (ERPIP 4.3.1) fer all Centrolled Area entries curing the occurrence, emergency and recovery phases of the accident.

~

Positive Access Centrol Established

/

imtzais Tim e 3.17 When notified by one of the following: (check ene) a

(

) Control Room

)

(

) TSC

.j

(

) RAD 1j

(

) R 202 Alarm (on LC07 or 2C07 boced)

Have the LRMT and REMT members prepare to pe: form Post-Accident 1

}

Reactor Coolant Sampling per ERPIP 4.4.7.3.

3.17.1 Commence monitoring per ERPIP 4.4.7.3.ecuirements.

k

(

4. l. 5-4 h

1

., m. w~.,.y -

- - m w-g,,fe-mm.

  • +e*""**[*DT*"#' * " ' * "

g y

E t

. 'b i

  • i

. g'

'I l

L

\\

,~.

N.. /

)

1

.j ERPIP 4.1.5 Rrl!ri/.G?ROVAL il

.l hEVISION CHANGE REVIEWER SIC /

SUPERVISOR.

POSRC PLANT SUPERINTENDENT i

D ATE i.

EPU SIC /DATE MTG

/DATE kl.u'. $ b r>#$'*IS 9%(f' 5 wujj -llt'7JN 3 l

M i

/

i

//

1

+

\\

==

'i 1

'A I

l I

I e

4 l.-

li 4

4 I

l t

l i

o l

l h'

i s

e e

ep

-p*+m a

  • ,,Wer*we M **
  • 9 N-** * * " ' *'

S-.

4-g

.ERPIP i.1.5.

-REV. S Change 1 l

. CALVERT CLIFFS NtJCLEAR ?OWER PLANT EMERGENCY RES?ONSE ?LAN

'I IMPL."ENTATION PROCEEURES LIST OF :.::rCTIVE PAGES

,1 l.

i ERPI? PAGE REV.

4.1.5-1 3

4.l~.5-2.

+

4.1.5-3 6

j 4.1.5-4 6

a 5

4.1.3-5 6

~'

4.1.5-6 S Change 1

].

4.1.5-7 a

z,_. -

4.1.5-8 3

i.1.5-9 S

i.1.5-10 i

1 a

'i

.I Ja.

f

)

ff

$)

O i

=zy m.=~,.cwym.-,.~.

. ~ -

- n - -, - - -,-. m

- - - - = -.

___ _ _~

4 i

  • RPIP 4.1.17 REV.9 i

TITLE:

SECURITY TEAM O

,i RESONSIBLE INDIVIDUAL:

SECURITY Team Leader

-r CONDITION:

Alert 6

Site Emergency i

General Emergency

-i i.

- CAUTION -

Failure to censult the.Radiatien Protection Directer during

(

j an emergency may result in undue radiation exposure to

~

personnel and violation of ALARA principles.

i NOTE -

Order of acticns Is not mandatcry. Initialing step completien must not delay acticn.

e <

A

~

/

ACTION:

51gnature Date 4

l.

INTERRCGATE ne personnel recall Ac-icn Comolete answering system (see A-achment !).

2.

CALL Emergency Persennel listed in Ac-icn Cemeiere APO. A.1 (SEC & PS first) who have not 4

i responded to the cager recall a

i

')

.i:!

3.

ESTABLISH a basic access centrol point Ac:icn Cemelete l l{

cn -he straign: sect:en of tne access. cad

.j just prier o passing uncer :he :ransmissien lines.

79 ty J

I i

_!. o f _'

4 k.)

l.

'w-a-

-,--+1g.-._t

..---.vyw.

-.-+.-y.

x,,3 m

.r., g,

s,.

9 p

ERPIP 4.L.i7 "l

R?.V. 9 4.

At the Access Control Point:

INFORM arriving plant workers (vehicles with CCNPP decals) to

~

a.

,D j

b.. IF PLANT EVACUATION is ordered, ADMIT ONLY emergency repcrt directly to their assembly areas.

?

[

workers past the Access Control Point unless entry is authorized by

~

the OSC Direc cr/SEC.

j c.

ALLOW access to all expected emergency vehicles.

d.

STOP all non-emergency vehicles that do not have CCNPP decals I

unless they are cleared for entry by the OSC Director /SEC.

RECORD name and destinat on of all personnel allowed access to i

e.

~

plant property.

e:

[

5.'

ACCOUNT for visitors that signed in at the South Ac-lon Comolete

.t Processing Su11 ding visit ~or's desk.

ll 6.

SEARCH areas fer personnel.

Action Comolete a.

Visitors Center Record visitors names /

'ch.

addresses. Escer: off-g site; close center.

u E

b.

Farm plc,cs/ buildings Direc: to Farm Demo Building.

Record names.

j c.

Waterfront a

d.

Camp Canoy J

Direc personnel

~

to Camp gate to await monitering.

)]

C1cse Camp.

U e.

73rehCuse, laydown O

1 areas, etc.

ti d

_2 cf.a n

-.riqprqr --~ -7{j-j; -- ym-.-v,.,, ;

- ~. - - - - - - -

....-_._y.,___.y,

s ERPLP 4.1.l7 REY.9 q

7.

RECEIVE accountability status from Assembly Area Leaders.

J

~3.

ESTABLISH communications with -

Action Comclete 3

the ECC/AECC.

r 4

9.

REPORT accountability status to Action Comelete SEC within 30 minu:es of assembly order.

10.

SEARCH for personnel that cannot be accounted for.

2 11.

Con:rol protected area access / egress:

a.

INFORM workers to report directly to their assembly area or emergency response facility.

2.

b.

IF PLANT EVACUATION !s ordered, ADMIT ONLY emergency workers into the protected area unless ent y is authorized by the OSC Direc:cr/SEC.

b' c.

WAIVE searches at expected emergency vehicles.

d.

ESCORT emergency vehicies. Only de first of several vehicles going to a single loca:icn recuires escor.

e.

ALLOW emergency verkers leaving de protec ed area to keep their dosimetry.

i I

i 12.

UNLCCX emergency ecuincen- *

-"a Sou:h Ac-ion Comete+e l Pe: cessing 3ui' ding: C'TT.0CK :he.U.:ernata l

I=ergency Centrol Cantar.

13.

ASSIST other emergency workers whenever possible.

i 11 FORWARD tnis checklist and all records related to this emergency response to the Emergency Planning Unit.

~

l Y;

l l

.}. Ci d

_, 7

-4

1 l

1 E' PIP 4.1.17 ' -

t R

e REV.9' I

ATTACHMENTI O

PAGER ANSWERING MACHINE INTEROGATION 1.

Press "STOP" button. Note the digital tape counter number.

2.

Press " REWIND" button to rewind the tape.

s 3.

Press " PLAY" button.

l.

4.

When the digital tape. counter reaches the number noted in Step 1 above, m

press "STOP" button.

A 4

5.

Press " AUTOMATIC" but:en to reset the machine.

c

~

.3

{',

F 1

m m

/

3 v

o o

a of.a y

c= = v= m:m -~~

- = = - - - - = - -

m

=

- +

s 1

~

r

,a s

~\\

, ', 7 +g

,t

==.*.: =,. - = <

-e e

.v j

C*

,'y1 m..

. y.

.,).

.z. y s

-l.

.g

, ERPI? 4. :.17 REVIIWA? PROVE.

4' i

REVISION CHANGE REVIEWER SIG/

$UPERVISOR PCSRC PLANT SUPERINTENDENT

DATE, EPU SIG/DATE MTG

/DATE l

l 10 n.Ci 53(ch,re N Z D->HI Q (il & J s II/,-/r, 0*

f

/

/* {

87/,N / 9 ht 38.CT

\\

t..,, d] ll12.fC?

I

,iy k

It

+'

o.

8.

T e.

t s

I

.1 L

y L

I 9

L I

l u

I u

T I

g u

i l

a e

~'

j l,

i 4

p

.,,.;.._.-.. v. 7 -.- --,. z. _-;: <- y,.gm ---( g.;y 3 q3,

,zy,. gyp y;-

- ~ r- :.y r~1rynn.

..2:

~-

h ER?IP 6.

17 '

b RE7. 9 f

f.

f CALVERT CLI??S NUCLEAR ?CWER ?I)lc

'(

N GENC? RESPONSE PLAN g

IMPLEMECAEION ?RCCEDL7ES I

{

T I

ER?I? PAGE REV.

f, l'

1 9

2 9

g 3

9 o

I

-4 9-

.e 3,

c 5

h 1

i l

i e

f t-(

t-4 r

0 a

5.

f l

0 s

Lx

ERPIP App A.4 REV.10

- TITLE: POLICE, FIRE AND MEDICAL EMERGENCY TELEPHONE NUMBERS A.

POLICE,

1.

Maryland State Police (Prince Frederick Barrack)

.J Telephone:

1 Radio Frequency:

. MHz Call Sigi 2.

Maryland Marine Police

~

~

Telephone:

Radio Frequency:

MHz Call Sign 3.

Calvert County Sheriff Deoartment Telephone:

Radio Frequency:

etHz Call Sign B.

_ FIRE 1.

Calvert County Volunteer Fire and Rescue Service.

I')

Telaphane Radio Frequency:

,- vtHz Call Sigt.

C.

MEDICAL 1.

Calvert Memorial Hosoital

- 2.

_Radiatien Management Corocration (RMC) 3.

BG&E Medical Directer and Staff Dr. W. A. Pillsbury a.

(Medical Director) b.

Dr. H. R. Brown (Sr. Clinical Physician) e t

e ERPIP App, A.4 REV. 10 c.

Dr. N. B. Carozza

~'".(Work)

(Sr. Physician)

(Home)

)~

d.

Dr. A. C. Fernandez (Work)

    • Physician)

(Home) m e.

r. -... tiarshbarger - CCNPP (Work)

(Physician Assistant)

'4 4.

Contracted Consulting PhysiE18.

The following physicians will be on call for the months indicated.

+

JANUARY.

Fricke

..:n n Y Fricke FEBRUARY Panos

.UST Panos MARCH Sterno SEPTEMBER Sterno APRIL Fricke OCTOBER Fricke MAY Panos NOVEMBER Panos 1

JUNE, Sterne DECEMBER Sterno 7

b.

If the atte..mog physician on-call is not readily available, call the physician on for the next month.

~

a.

Dr. Alexander N. Panos, Md.

'(Work) l((Home)

Home)

' t-b.

Dr. D;tvid W. Fricke, Md.

l((Home) OR

, Work)

S Mu 2


,-r-

~,

i ERPIP App A.4 REV. 10 J

,j c.

Dr. Gerald P. Sterner, Md.

ork)

W

..~.

' [,)

', Work)

(Home)

(Answering Service) 5.

Ambulance (Calvert County Volunteer Fire and Rescue Service)

Telephone:

Radio Frequency.

MHz Call Sign k.

S e

..I

,h

{

l 1

8 4 g

3 i

I

i i

e e

'* o.

i ATTACHMENT 1 o

~

[

ERPIP App.A.4 REVIN/ APPROVAL l

6, l

l REVISION CHANGE REVIEWER SIG/

SUPERVISOR POSRC PLANT SUPERINTENDENT DATE EPU SIG/DATE MTG

/DATE 0$

0 %wk v.ld 0.0 Qwgj i2ln/y, I

~

/

e e

I S

9 3

1 i

n :,

~ %.)

i t

b

]

i i

I t

4 M

1 I.

L 3

/

i l

a

^

g. v g

%L')

e

~~Mx',7"7Kry?'27. '_?g: C;T *Tp'yqQJg7sp?%;}'TT*3 '* ~.*~

T '*"~'"KOfli:T ~ K " ~ W-~? '^ ' T ' l

i ERPIP App,. A 4

' -l Pcg3 1 cf 1..,

Rr.v.10

'j i

1 O

CALVERT CLIFFS NUCLEAR POWER PLANT DERGENCY RESPONSE PLAN

. iq IMPLEMENTATION PROCEDURES' y

'I LIST OF EFFECTIVE PAGES _

.6

.:1 ERPIP PAGE REV.

+J

'1 1

10

.sf

q 3

2 to l

. 3

- 10 3

_l e

p

  • ==

a GC F'.1

1 1

0:

~5 iIlm 4

i

-h lg

_!y M

M

'V 4

ti 1a L. T e

e 8'

s

[.

SRPIP App. 3.1 Rsv.9 3

i.

\\

l INDEX OF EQU1PME NT CHECKLISTS t

l

@J l

Table 1 Controlled Area Medical Treatment Recm-Radiation Protection and Decentamination Supplies i

Table 1-1 Controlled Area Medical Treatment Room-Medical Equipment and i

Supplies i

Table 2 Calvert Memorial Hcspital Radiation Safety Emergency Equipmt.t k

Table 3.

Control Room Emergency Equipment Inventery j

Table 4 Emergency Centrol Center (South Service Building) Emergency Equipment

(

Inventory f

s l

Table 4.-l Emergency Centrol Center (ECC Kit) Inventory f

Table 5 Emergency Mobile Monitori' g Kit Equipment Inventory n

Table 6 Alternate Emergency Centrol Center (Farm Demonstration Building)

I Emergency Equipment Inventcry Table 7 Oceratienal Support Center (South Service Building) Emergency h

Equip.nent Inventory Table 3 Tecnnical Support Center Emergency Supplies Inventary Table 9 North Service Building Emergency Equipment Inventcry Tacle 10 Emergency Equipment in Reentry Lccker ('45' Level)

Table 11 Media Ccmmunicatiens Center (Fairgrounds) Emergency Equipment Inventery Table 12 South Precessing Suilding Emergency Equipment Inventory Table 13 Emergency Fire Fighting Equipment Located in Turbine Building 1

Table la Emergency Equipment in 13' Trailer (Moolle Lao)

Table 13 Emergency Equipment in 20' Trailer (Mobile Lac)

Table 16 Total ERPIP Per able Radiaticn Survey Instruments and Air Samplers for Emergency Use Only i

f'h

$)

I t

m '

b 1r ge 4

(

C *?

7M* k

?

^

ERDLD App. 5,1 l

Rev.9 1

..}

TABLEl

~

.I.

CONTROLLED AREA MEDICAL fREATMENT RCOM l

EMERGENCY EQULDMENT INVENTORY

~

a AMBULANCE KIT 8-520 SN cal Due Batt. CK Source C K Cs-l37 Scurce.

SN 5RO O.50 R (J) cal Due Ocsimeter Charger Anti-C Sets (6)

.)

Batteries O Cell (4)

~

Masking Tape (i reil)

Batteries AA Call (4)

Radiarien Tape (I rell) f ?.;

?sper Smears (t Sex)

Radiarien Rece (30 f.)

?cly Sags (3) 3

}

RCOM & CA3INET3 9

Decentamina:icn :' le-top wi:n 30 gallen helcing cent. (!)

NM, : ~

Sicassay XI:(1)

Lead Blanke:s (2) t<

Trauma (I Ki: (!)

Lead Cen:2.iner fer Sameles (!)

L3 Wincew 5hieic (!)

?!astic Shee:mg (I reti)

TI.D ring-type (6)

?!as-dc Shce Covers (!2) 53KI Sciunen (15td

?las :c Acrens16) e l:

C:ner mecic.'! su pties are inven:criec by me mecical Cecar men:.

l.1 i

\\.h REMARK.5:

i.

'4 It]

rj LNVENTORY SY:

DA T.:

q REVIE'7ED BY:

CATE:

.'.4'!

't y

d i

3 1

?:i

'W

' egypysY.7277'* ' m:'r"lC????;27"~* Kp,-

*7~~~.
  • ~ ~ '

""*~7cm*

~~;

~ ~ ' ' ~ ~ ~ ~ "

t ERPIP App. B.1 Rev.9 l

TABLEl-1 Q-CONTROLLED AREA MEDICAL TREATMENT ROOM MEDICAL EQUIPMENT AND SUPPLIE.S INVENTORY 7

- NOTE -

r Items on this list are inventeried and replaced by BG&E medical services.

h SHELF A - WHITE CABINET Basin Kit (1)

Emesis Basin (1)

Gauze 3x3 (100 Rolls)

Solution Bowl (1)

Gauze 2x2 (100 Rolls)

Medicine Cups, Disposable, Surgipad 3x10 (1 Pkg.

100/?kg. (1 pkg.)

Laryngescope 3/ Box (1 Box)

Crutch Tips (2)

Ambu Bag (1)

  • First Aid Book (1) s SHELF B - WHITE CABINET

~~

Ammonia Amoules (10)

Dacriose, 4 oz. Bonle (1)

Tourniquet (1)

Disposable Needles 1

Triangular Bandage (1) 20 ga. - 1/2" (20)

Isopropyl Alcenol, J00ml.

Disposable Syringe (1) Bonle 60cc (1)

Atropine Sulfate 0.amg/cc Disposable Syringe (i Vial) Exp. Date 20cc (1) pinephrine 30cc! vial Disposable Syringe -

h(1 Vial) Exp. Date 10cc (1)

?

Disposable Syringe 3cc (6)

Disposable Syringe Ice (6)

RADIOPROTECTIVE DRUGS:

Inferen, Injectable, 2 mi amples (3) ac. Date Calphesan, Injec acle, 3 amples/pkg. (1 pkg.)

Exp. Date Zincate Capsules,100's (1 Bonie)

Exp. Date Phespnojel,12 oz. Bonie (2 Bonles)

Neutra-Phos Capsules,100's (1 Bonie)

Exc. Date Saturated Solution or Potassium locice, 2 oz. Bonle (1 Bonie)

Exp. Date Magnesium Sulf are (1 Bonie)

~

SHELF C - WHITE CABINET Conen Ticoea Applicators, Eye Pads (a) 50's (1 B'ox)

Vacutainer Neecles (12)

Pontecaine, Vial (1)

Achesive Tape !"

pTelf a Pads (12)

(1 Roll)

O!Achesive Tape 1/2 (1 Roll)

Achesive Tape 3" (1 Rell) 3-msqqMYm'parc mqm qc:v.. -

~= Y p g q:7 ; T" " 'qn m i y,7 L'f _ 7'~"

ERPIP App. 3.!

Rev.9

. J' a

i d.

i TABLE 1-1 (Centinued) t i

h

~

SHELF 0 WHITE CASINET Saracine ljCCmi.)

Gauze Sandage 2" Scalpel #11 (6)

(12 Rc!1s)

~

Scalpel //13 (6)

Gauze Sandage 3" Sand-Aid !" Reg. (30)

(12 Rolls)

T Sand-Aid 2" Ex:ra Lg. (12)

Ace Bandage 2"(2 Rolls)

Guage Sandage 1" Ace Sandage 3"(2 Retis)

(I2 Rolls)

Ace Sandage 2" (2 Rolls)

Scissors (1)

DRATERS UNDER CLAS5 THITE CABINET Re:cer Oversnces (6 ? airs)

Stethoscoce (1)

Aprens (6)

S/P Cuff (1)

Surgecn Caps (6)

Reflex Hammer (1)

Surgical Masks (6)

Tracn Tube 13 mm. (2)

Steri-Oraces (6)

Cuff ed Endo:racneal Tube (c) d Exam Cloves. Medium Lifesave "5" Tube (!)

(6 ? airs)

Tool Slanke:s (2)

Vinyt Gloves, Large Traca Set (!)

(6 Pairs)

~

5teri-Scies (6 ?kgs.)

T Gowns (6)

A 1

5 INK AND CA3INET (TEMS A

i

l.. 5ter:-Tray w/ Fcrcecs Chicrex. Quar:

.,1,~

(1 set)

(2 Sc.les)

'L.r.la:acle Fuu Leg Solin:

!0 Q:. Basin (1)

(1)

Aspira::r (1) i, (nfla:acie !/2 Lag Solin:

[.V. Neecles (6)

(1)

TV Cuner Sets (6)

~~

Aluminum See =.er (1)

C11ccium (2 Set-les) j E.R. ?ack (Tcwels & Craces)

Cru:cnes (! Pac) 1 (2 Sets)

Urinal (1) 1 Ir-iga:icn Syr:nge w/ Tray

anium Cioxice

~~

L !

(15et)

(1 3ct:1e) l Ncrmal 5 aline 2fCmt.

Cot :n Sans (100)

(2 Sc.ies) Ex:. Ca:e Sed ?an (1) t 4

]

DJ/i/2NS 23Cmi. (2 So: :ess Ex. Da e Ner-al 5 aline ir-. gar: n q

!0CC mi. (2 Sc::les)

D Ext. Ca:e CECON X:T:

7 f

Nivea Cream (1.*ar)

Mair CI!:cers (1)

Manc 3r;.snes (2)

Racer (l' 5et)

%]

A55AY KIT:

Lavencer I o T>.ces (6)

Rec I;C T'.:Oes[5I 3

Kleenex(i 3Cx)

?acer Container 3 ',6)

, E.,

.d.,., v 00. etr ', a J

.I a

v 7 77'n W f W ~ W X T *X 2

  • TT.':** V T ?le'.

" ~ ~ ~ ~

'WF

. K'-K T"'

"P ~ '~~~ '

~Y""~ ~i' ~6 '

)

ERP!P App. B.1 l

i Rev.9 s

(I TABLE 1 1 (Continued)

^

i O

'^ REMARKS:

4

~

e-1 INVENTORY BY:

DATE j.

REVIEWkD BY' DATE NOTE: Person performing the revieu should be the first line superviser of the person who performed the inventory.

(

a. -
  1. e4 1,

)

e.

3 1

1,

,b e

1 1

i l,

f 4

I l

~

I 9

I

(_In 3

i

jm;mn-ryn y?
:~-

--v q --~r

~~~m-m v ~ c -"'r: = = :~m ~'" =~r#_

~

ER.21P App. 5.1 _ __ -

Rev.9 0

TA3LE 2 l

CALVERT MEMOPJAL HOSPITAL EMERGENCY ECUIPMENT !NVENTORY

!O' INSTRUMENTATI5N & COSIMETRY & ACCESSORIES 4

PIC 6A SN cal Due San.Ck Scurce Ck

.RM-14 5N Cab Due Sat. Ck Source Ck l{

Dosimeter Char'ger (1)

SRO 0-200 mR (10)

SRO 0-5 R (10)

TLD 3adge Tyne (!O) 4 SRD 0-200 R (10) 5 4

i TLD, Rirg-type (3)

~"

E 3at eries (change 2nd & 'tn Quar ers) 9v.(2)

AA(2) a

!I EOUTPMENT & SUCCT ' 9

'" Dec:n Tacle Tcp (i)

Merculite Flect Covering (i set) i Sample XI: (1)

Herc :li e Rcil (1) 4 i

Tincew Shield (1)

tastic 3ags (!2)

!^

Leac 5 ample Cenniner (1)

Masking Tace (i Rell)

$hewe-Heac wi n Hese (1)

Raciatien Tarning Signs 'l set)

(Inciuces Tace i Rece)

Cec:n"minaten Manual (!)

<i REMARKS:

4 i

LNVENTCRY SY:

CATE:

i E

I "A

4 i

4 4

i f

7~ y N f4'",'If T 'y " N ? q ?@ g.TC~I' T.*/""'T 7 ;- --

-7'*'~"T.

-5""-~~~"-

- -- T q-i ~ ~r - -

- -" 1 s

f

[

ERPIP App. S.1 Rev.9 i

I

)

1 0

TABLE 3 Q

CONTROL ROOM l

EMERGENCY EQUIPMENT tNVENTORY l

l

~

y i

EMERGENCY KIT (Located behind Centrol Room File Cabinets)

~ ~ ~

CAL.

BATT.

SOURCE Instruments:

S.N.

DATE CK.

CK.

8 FIC 6A l

-PIC6A l

MS-2/ SPA-3

' Air Sampler f-I 1

Desimetrv:

Cal. Date SRD 0-200mR (10)

SRD 0-1R (10)

TLD (10)

Miscellaneous:

Desimeter Charger (1)

Particulate Filters (1 Sox) a-(

Charcoal Car. (10)

Silver Zeolite Cart. (10)

Flashlignt (1)

Set of Keys (1 set)

Bar eries (Change 2nd & 4th Quarters) 9 v. (4)

AA Cell (2)

O Cell Ncg. Pressure Respirators (10)

Soare Cartricges fer Respirators (10)

Anti-C Ccmplete Sets (10)

SHIFT SUPERVISORS OFFICE

~

Emergency Call Lis (1)

P&ID, Layouts (I set)

ERP Copy (1)

Trauma II Kit (1)

(Replace if Damaged or Oaan)

MRPIP Ccpy (1) b/

7 l

'Tg.p cy;j m~

mz m-n.= y ~.g -.

,~~+m-

=~

T- - --^

"-- - =

~~-

T l

$RPLo Apc. 3.1

~

Rev 9 j

TABLE 3 (Continued)'

Centrol Rocm (R:. side wall, ' ehind Uni: I cane!)

Q s

10 mile EPZ Mac tisopieths Overlays (i set) 30 mile EPZ Map & Isopleths Overlays (1 se )

l Senind Cent ci Room (Entrance to Emergency Stairuell)~

f SiOPAK-4GP Breathing Appara:us (23)

REMARKS:

I 1

[

+

INVENTORY 3Y:

DATE RjiVEWED SY:

DATE k

i a

y-1

\\

Ye I

K 3

hmwrim767r~_:7K73$ wyr.,F75%T ~T"'NTT"~7~~

'~ ^

~Y"TT~ ~7~;

l ERPIP App. S.1 Rev.9 3

a TABLE 4 EMERGENCY CONTROL CENTER (SOUTH SERVICE BLDG. - Classroom 1 & 2)

EMERGENCY EQUIPMENT-INVENTORY i

INSTRUMENTATION & ACCESSORIES j

h g

S.N.

CAL.DATE BATT.CK.

SOURCE CK.

s MS-Z/ SPA-3 E-520' i

i l

PRM aA/AC-3 I

~

5 l

AIR SAMPLER -

I TI-35 CALCULATOR

~

I l

TI-55 CALCULATOR TI-55 CALCULATOR

.i 1

o

{AMPLING MATERIALS Particulate Filters (3 Soxes)

Silver Teolite Car ridges (3) i I

e SA i i RIES (Change 2nd & 'th Quar ers) 4 i

"D" Cell (3)

?

1 MISCELLANEOUS Povidine Scruo Solutien (1 Settle)

[

Trauma II Mecical Kit. (1)

)

ECC Emergency Kit (1)

(Ste Table 'l fer Centent:s) i N

le 4

+

9 I

b-

,,e

.N

-[

'4-

"M

  • [
      • I'#

7M

""NPh*

  • O g*W" 9 F4%

$ 9 F4"""-

+

...j ER.Ct? Acc. 8.1

-j Rey.9 a

1'-

TABLE '+ (Cen:inuec)'

t 1 --

)

d' R E.:ERENCE MATERIAL & ADMINI5TRATIVE AIDS

.4 t,..

'l Plan: Status Board (1)

Offsite Status Scard (t) 10 Mlle EPZ Map & Isopleth Overlays (1 se:)

J*i 30 Mile EP! Map & Isopleth Over!ays (1 set)

1,.

?&!D's.ar.d Building Laycut Orawings (10 sets)

ERo Manual (1)

INPO Manual

~

l Radia:icn Safe:y ? :cedures (i se:)

2mergency Leg Scok (1)

~

ERPLo Manuals (16)

(Copy No. 2, 3, 4, 3, 6, 7, 3, 9,10,11,12,13,14, l 3, L 6,17) s

'4

,5

'I J,

j ADMINISTRAT'.VE & OF ICE SUCCLIES H-
u..cccares,,J)
cisscrs i.2) u i

l. Stk. Tax Markers (J)

q. ' --

q

?-nc:is (24)

Red Tax Markers (3)

Pens (24)

.?

f1 Yeilcw Tax Marke.s (J)

Stk. Frewrite Markars (3) i.

.I

? ace-C'.ics (10 Scxe-;

Slee ? owri:e Mar *<ers (3) 1 1 i P2cer Cames 'J Saxes)

Linec Pacer Ta:Lets (12)

Unlinec No ecacs (10)

Tace Ciscensers ij) r i;

Desk St2 piers (3)

Tace, Rolls (3)

-{'

5 2:les (3 Sexes) l A1:. ECC ?hene Cir-c cry (a) 0.C..:hene Cir-e :ry (i)

J 5ALTC. Phene Direc: cry (1)

ANNAP./?R. FRED. ?hene Direc cry (L' j

LECNAROTOWN/LAPLATA.:hene Cirec ry (!)

q ER. IP ?cem 3.1-A (20)

I b IR.:Le ?:rm 2.3. '.S (IC) n

)

he Y )

1.)

)$D YAN 4..$..,v '...

j t

i' : "

' s

![

- D.. IE Is.ap*. =.

4. 3 [. [..T.

I

_=~. II..S.7m.p

e... J..', v9 [
  • O., )

Q 6

s t.

[

')

d.,.

- !G M

tl

-2"3ftn % W W 5 @5 D.1. Q % W

'~",7-?7Cy ym ?WT: ' 'WCl."~7Tri'~

~

~ }'[" ' Wi

.3-ERPIP App. 3.1 Rev.9 r.

I i :

}

TABLE 4 (Continued)

I h

.]

ERPIP Fcem 4.2-8 (20)

ERPIP Fcem 4.3.1-0 (20) 1

'l ERPIP Fcem 4.2-C (20)

s

.H..

REMARKS:

y

'l 1

l l

INVENTORY BY:

DATE

~:1 REVEWED BY:

DATE y'

74

.j 11 e5 i

?k 9

r e

e-T t

e f I q

1 Li

.t

3 cj O.

i,3

'JV 9

l1

'i

-]

. ERPIP App. 3.1 Rev.9 I

i e

TABLE 4-1 EMERGENCY CONTROL CENTER

,1 ECC KIT INVENTORY 1

,1 m

INSTRUMENTATION & ACCESSORIES

-r 5.N.

. CAL. DUE DATE 3ATT.CK.

SCURCE CK.

PIC-6A FIC-6A Cs-L37 Scurce

~

~

OOSIMETRY CAL. QUE DATE 4

SRD 0-2CCma (2.5)

SRO 0-50R (23)

~ "

3RO 0-2COR (23)

Ocsimeter Charger (1)

MISCEL'_ANEC US

' 3aneries. 9 voi:(2)

Baneries, "AA" Ce!! (2)

~

(Replace 2nd 2 atn Quar ers)

(Replace 2nc & a n Quar ers) r Emergency Venicie Keys

? ly Sags, Sma!! (3)

(2 Se:s),-(2 Venicies)

Note Pads (c)

Aux. Sicg. Eleva::r Key

?-ns/? enc:Is (10 Soxes) i

(' Set)

'Vax P-ncils, 31k. (2 Soxes)

r n 2emo 2. en: Ca:e.

Tax ?r.c:1, Rec (2 Soxes)

Key (15e:}

Tax Penci!, Yellow (2 3cxes)

RE.MARKSi I

i INVENTCRY SY:

DAr.

l 2_: e.= ;;_ a. = v..

,nm._

NC' 3: Persen :ederming :ne reveu shcuic :e :he :i.s: iine sucerviser :f ne persen u.mo pedom.::

me inventory.

l

.4 W O M Q W P W 1? W W T C T W D " ' T

  • K C-

.L

,, :%. 4 A..

- :.* *" ~ ~~ mMcL TT TT 2 L'~TL - - D

'*^

ERPIP App. B.1 Rev.9 TABLES h

EMERGENCY MOBILE MONITORING KIT #

EQUIPMENT LNVENTORY NOTE: Kits 1,2, & 3 are Iocated at South Processing Suilding. Kit 4 is located in the suburban 4WD vchicle.

5.N.

CAL.DATE BATT. CK.

SOURCE CK.

E-520 MS-2/ SPA-3 i

AIR SAMPLEP CALCULATOR Cs-137 Source

.+

s.

DOSIMETRY CAL. D ATE SRD 0 - 200 mR (3)

TLD (3)

SRD 0 - 200 R (3)

Desimeter Charger (1) s SAMPLING MATERIALS

. Par-iculate Filters (1 Box)

Silver Zeolite Car. (13) harcoal Cartridges (1 Sox)

Paper Smears (1 Sox)

Charcoal Filter Head (1)

Silver Zeolite Head (1)

SA i i tRIES (Change 2nc. & 4th. Quar ers)

D Cell (6)

AA Cell (2)

Cel Cell (Charge Quarterly) (1)

I PROTECTIVE CLOTHING & MISCELLANEOUS Anti-C Complete seu (3)

Flashlignt (1).

l Neg. Pressure Respirators (3)

Raciation Tape (I roll) l Scare Resp. Cartridges (3)

Radiatien Signs (1 set)

Masking Tace (i roll)

Poly Sags, Small (J)

ERPIP Proc. & Macs ( set)

Poly Bags. Large (3) l Pen /Notepacs (2)

Lead Sricks (2) 1 Read Safety Vests (3)

Road Flares (3)

REMARKS:

hNVENTDRY SY:

DATE l

i REVIETED BY:

DATE i

13 -

{:Qg.p*p;r - q *:r<nv:'.

w~~

_c;; :' ' -

~ - -

~m~~~--~

7

- - ~ - -

ERPIP Acp. S.!

l R e v., 9 A

.)

e TABLE 6 ALT ~c~RNATE EMERGENCY CONTROL CENTER EMERGENCY EQUIPMENT LNVENTORY ic J

INSTRUMENTATION & ACCE550 RIES T

i 5.N.

CAL. DUE DAi c cATT.CX.

$OURCE CK.

l E-520

?!C-6A -

l PTC-6A PIC-6A

=-

. IC-6 A

~

RO AA RC aA 1

l M5-2/5FA-3 1

RM-ta/HP210 f '.

m

'?RM 2A/AC-3 t

j AIR 5 AMPLER t

i j

C& L37 icur:s t

4

~~ 3J Caleda:::r 1

1 I-J5 Caleda: r i

t SAMPL:NC tt Ar.R*AL3 l

. ar-iedare FU:ers (2 Soxes)

C.' art:ai FU:ers (3 Soxes) i Saver T.acil:e Car--icges (13) l (Change hc 2 tr. Quar ers) 22

-t'"

/

?,.g o..I.S9 g

-.m ee a ;i 's.' H e 4..; e %.3g (sy

.-J J

w w.e o

y_

\\

s O

4 Ymwm;;xamyvmpvrwme.7mrewcm=m

= mev e r :=:;n m = W n = Y " ~

~'

1 l

ERP!P App. B.i Rev.9

)

~

TABLE 6 (Continued)

A

't-00SIMETRY CAL. DUE DATE TLD (25)

SRD $ -200mR (25) 4 SRD $ -50R (23)

SRD D -200R (25)

Dosimeter Charger (2)

PROTECTIVE EOUIPMENT & SUPPLIES

[

Anti-C Complete Sets (5)

Coveralls (100) h Neg. Pressure Respirators (5)

Masking Tape (4 rolls) j Spare Filter Car ridges (5)

Radiation Tape (2 coils)

?

f Towels (10)

Soft Bristle Brush (10)

~-

Soap Bars (10)

Providine (1 Bottle)

[

Saturated Solution of Potassium Iodide (2 Bot.le:;)

~

2 or. Sottles @ 350 Doses eacn Tesuma II Medical Kit (1)

Decon Kit (1) 4 SIOPAK-60P SCSA (42)

( icassay Kit (1) e REFERENCE MATERIALS & ADMINISTRATIVE AIDS Macs & Isopleth Overlays (1 set)

INFO Resources Manual (1)

ERP Mammi (1 c::py)

Radiation safety Procecures Rev. No.

(1 set)

Mc. Emergency P!an & Appencix (1 set) j ERPIP Manuals (16)

(Copy No 13, 19, 20, 21, 22, 23, 2'4, 23, 26, 27, 23, 29, 30, 31, 32, 33) 1 Rev.No.

Desk Top Easels (5)

ADMINISTRATIVE & OFFICE SUPPLIES y

-1 Scissors (6)

]

Clipboards (20) i Bik. Wax Markers (2 Soxes)

Pencds (5 Soxes)

Pens (5 Soxes) 3 Qed Wax Markers (2 Soxes)

]

1 I

i 3-i r

  • =. ' ' ~

t -se ** q l

~*******r'y*_.-' ' ' *

    • 'T

'": '~

"~

"~ '

ERPl? Apc. 8.1 Rev.9 TABLE 6 (Cen:inued)-

~,

IcHew Wax Markers BIk. Prowrite Markers (3)

S i

(2 Boxes)

I

.. Red Prowrite Marken (3) 7 i

Paper Clips (10 Soxes) -

Blue Prowri e Markers (3) f Paper Clamps (10 Scxes)

Lg. Binder Clips (10 Soxes) h Red Crayons (J) 12" Rulers (J)

Slum Crayens (31 Ruci:er Sancs (J Boxes)

YeHow Crayens (J)

?usn Pins (5 Scxes)

Sc ing (I roll)

Scard Erasers (J) 3 1

I i

t, 5:ac. iers (12)

Tac. e Disc. ensers (!O)

St.apies (12 Soxes)

Tace. Scot:n (LG Rolls) h31/2 Notecads (13) 5xa 1/2 Notecacs (ij) s ji ha Notecacs (10)

Lined 3 !/2 x !! Taciers (20)

_ 3 t/2 x !! Send Pacer 3 t/2 x li Onien ? aper Q"';

(2 Scxes)

(2 Soxes) l

{

27x3a ?acer (4 pacs)

Manila :ctders (i 3cx) l EFI Macs (2 ? ads)

Sceed Memes (i Sox)

Susiness hveicpes w/Co. Accress (100)

Su:1 cess hveicpes, Srewn, Plain (J0) l Smati Sveicpes, Srewn, ?!ain (30) l

!2x9 3rewn hveicpes w/Cc. Accress (30) ifx10 3rewn.nveicces w/Cc. Accress (30)

Sa. vin Cecier sucpiles:

3 Dispersan: (2 Set !es) l 7:ner (2 3ct.les) 3 t/2 x !! Pacer (3 ;kgs.)

l 3 !!2 x la Facer (3 ;k;s.)

Xerox ;G0/2LO Telecocier.:acer (i Scx) b Tei<- enix Or/-5ilver Paper (2 Rails) i k

L5 mm:mm - rcqpm3mmnmmm=mm?r mm-7m=pwracunmrtmr ermm

.i

~

I ERPIP App. B.1' Rev.9

. -)

i t ABLE 6 (Continued) t%

x.sERPIP Form 3.1-A,(30)

ERPIP Fcem c.4.1-A (50)

CRPIP Fcem 5.2-A (30)

- ERPIP Form 4.4.1-B (50) hj ij ERPIP Form 4.3.1-B (30)

ERPIP Fcem 4.4.1-C (50)

/ I ERPIP Form 4.3.1-C (30)

ERPIP Form 4.4.1-0 (50) a ERPIP Form 4.3.1-D (30)

ERPIP Fcem 4.4.2-A (50)

ERPIP Fcem 4.3.1-E (30)

ERPIP Form 4.4.2-8 (50)

ERPIP Form 4.1.1-A (30)

ERP!P Form 4.2.3-A (50)

.ERPIP Form 4.2-A (30)

ERPIP Fcem c.4.3-8 (30)

{

FRPIP Fcem 4.2-8 (30)

ERPIP Form c.4.3-C (50) 1 ERPIP Form 4.24 (30)

~

ERPIP Form 4.4.5-8 (50) f}j ERPIP Fcem B.3-1 (30)

ERPIP Fcem 4.4.7.1-E (50)

ERPIP Form B.3-3 (30)

RCP 3-301-1 (50)

ERPIP Fcem B.3-6, 7 (30)

'~

)l MISCELLANEOUS EOUIPMENT l

. avin Copier (1) j Operability Ck.

Dic aphone Answering Machine (2)

A.

M)

Operability Ck.

L1 Radic (1)

Operability Ck.

01 Simplex Time Rec::rder (1)

{

Operability Ck.

.)

.]

Typewriters (3) i;i Operability Ck.

e i

Xerox Telecopier (1)

. :-)

y Operability Ck.

,3 lj Omnif ax T(.lecopier (1) 3 q

Operability Ck.

d Midas Terminal (1)

]

i Operability Ck.

N Tek renix Hard Copier (1) d Q Operability Ck.

m

?

.f L7 1

,___.3,,._...-

_..m._._...,,._

1, ERPIP App. S.1 t

.s e v. >

)

=

t 1^,

TABLE 6 (ContinuedV s

REMARKS:

-4 e

JJ 2

INVENTORY SY:

DATE REVEWED BY:

DAT.

i e

=

C e

.b 5

-A-il A

[T

'*g 6

...i

_1

}

..4 4

7 3

4 1

1 1

4

.4 i

1 1

1

=

~ \\..

4 h

1

..g i

Y

-.t

._g

.t

(!r,

1 i

-3 i

l I

g i

,7 4

i 4

pp p g qr-_p y-~;9q.qz ygr q,3;g:~,p77x~i' :,Krm 3,777~7q,,v,_.,,, ; qr * ',* RT77w

-~,:~~~~.

.i i.i SRPIP App. S.i Rev.9 ij TABLE 7

- h OPERATIONAL SUPPORT CENTER EMERGENCY EQUIPMENT INVENTORY 4

L:

INSTRUMENTATION & ACCESSORIES g

S.N.

CAL.DATE BATT.CK.

SOURCE CK.

Q PIC-6A b,

RO-4A If RO 4A

'j E-520 l4 il RO-2A AIR SAMPLER v:

Cs-137 Scurce

.g OSIMETRY CAL.DATE e

!)

Ti D Specials (15 sets Inc.tuding 3 Hi-Range SRDs)

^

.4

.1-}

TLD Specials (13 sets wit.h no Hi-Range SRDs)

TLD Whcie Body Badges (30) 9 TLD Surveinance Badges (20) l l-SRD 0-200mR (50)

SRD 0-5 REM ('23)

SRD 3-50 REM (23) l il SRD b-200 REM (23)

'A-l..f Ocsimeter Chargers (4) y

'd SA i i.-RIES (Change 2nd. & ath Quarters) 1j

(}D" Ceu (2)

"AA" Cell (3) 4 5

q 4j

!9 -

.1

'~

_ m ; messy g < y-=sez--.~s

. ~ +

. ~.

~ *

... ' ~.

"~^?'[ G}

v o w ' y**"*- ~ '

~.

ERof? Apd. B.,1 Rev.9 I'

t A=L:. e- (ven.inued) i Op i

SAM? LING MATERIAL 5 T

Par.icula e Filters (I Sox)'

~

N Si!ver Ieoli e Cart.(1 Box)

PROTECTIVE CLOTMING & MISCELLANEOUS Anti-C Ccmplete Se s (23)

?! ash!!gh (1)

.i

-}

Neg. Fressure Respirators (27)

Smoke Tubes (1 ?kg.)

I 1

>}

5 pare Rubber Gioves (1 Bag)

Canvas 3ag (1) 5 pare-Cloth Gloves (! Sag)

Small ?!astic Bags (30)

..a 1

Space ?!astic Sco:ies (1 Sag)

Securi:y Card Clips (23) 1q t

Masking Tape (7 R:lls) 3 2

ADMINISTRATIVE 5U?cLIES

}

'f l

C11::bcarcs 00) 5cctcn Tape (2 Rails)

Pens (20)

Tape Dispensers (2)

Fenciis (20) 5cacies (2 Soxes)

J,j L'" Rulers (2) 5:aciers (2) i f ace"f Gcs s/. Ooxes}

-e pe*

in

  • e f

2Cssers s2)

Rubcer Sancs (2 3cxes)

?2cer C'ames (2 Soxes) 9 x 3 '/2 Notecacs (3) 6 x

./2 Nctecacs (2) i 3 !/2 x 'l Linec ?2cer (3 ?acs)

Manila icers (2

i

~

1*

D Access Cen roi Car:s ('.C0)

Ocse Lim:: 5 ca:emen:G ?ac) 7

,1 lj vtst: rs Ocsimer y chec<

~

Li

!n/ Cut 5heet (! Pac) aj NRC ? rm 2 (i.:ac)

ER?!? =ccm 5.2-A G3)

M j.

Weekly Cestmet y Rec:rc (30)

ER?!? :rm 2.3..-h i.3) li imad Leg 3cok,1) 3R_ I? =ccm 1.3..-i

.3) l

_,,, p) y I

R3 Cia:lOn b*d0r'"Is"".On ?OT'"'s 3R.=5? 'COmClete! '. COOY)

D I. ?ac) t4 If

t
1. 4

'4 w "'*r W* i'M

% r**Tygy*;pg q}$'*QAyG.'t*tW4MZ41*KgqcW2'qq'K *l.'

,,.Ti W W,71='~Jg'.

, W,r T:y C.%Tl3

ERPIP App. B.1 Rev.9 s.,.

TABLE 7 (Coiitinued) d O.-

T ADD / HIRE SHEETS (1 Pad)

OPTION 1 CCNPP Personnel Monitoring Record (1) f OPTION 14 Quarter Dese Listing (1)

REMARKS:

O^E f

INVENTORY BY:

DAT:-

REVEWED BY:

!O l

i-t 1

4 1,

i i

i i

l 1

i i

9 i

i t

i 21 I

j I

.w.-

.w*

.RPl?.s. oc..,2.1 Rev,9.

c i %.

TABLE 3 f

TECHNICAL SUPPORT CENTER

)

EMERGENCY ECUIPMENT WVENTCRY t.a MfSCELLANECUS ECUIPMENT

~

4 l

Scund Powered Phene Sets (2)

.=.

Sound ?cwet-d :hene Ex ensien Cceds (2) 9l Digital Voltmeter (1)

DC Pcwer Sucply (J)

-i cx ension Cced 1

.1 Ra:ces (J) fL\\

4 Gauze (L Roll)

Sc twcrivers (J)

?!asntigns (J)

.. -. !astic Ties (1 Suncie)

_1.

5inaving Cream (1 can)

P-

'0" Call Sa: aries (12)

(Change 2nd & atn Quar e s)

... y, rN N t ".;..A. -~.'/ 2-6 ^ C=..u".C_ A.:0 7.f T 'a C*

- m 4

u..:ccares T. )

mers,..a a a Notecncs 'ic)

Pacer CEcs (1 :cxes) x 2x". Nctecacs I!G) 5:aciers (31 I

6x hNotecacs ia) 5 actes (i :cx) a l* Masking Tace (1 coi!)

Magic Mari<ers (2 :cxes)

Gracn Paper (1 pacs) ens (a cxes)

IWii :ac. er ( :acs)

Teecnene Messaces (3 pacs) 2 Manila ?ctcers (.' 00)

Tsce 2:scenser

'.)

z.s 79 P t y.. g. e

-..es

.-s-

.m+-o g;*= e

, p g see.

tgiee g 99

.p L

g my 7 mmm3

. _s.

I ERPIP App. B.1 a

Rev.9 TABLE 3 (Continued)

A j

YJ Conference Memes (2 pads)

Scotch Tape (2 rolls) y TSCD Checklist Notebook (1)

Pencils (4 boxes) a

'. )h Scissors (1)

Rubber Erasers (4) 4 c-

',q Pencil Sharpener (1)

Staple Removers (1)

~

cl1 3" Binders (2)

Bik. Wax Pencils (1 box)

'lj 7

' Highlight Markers (2 boxes)

Co. Telechene Direc cry (1)

Carben Paper (1 box)

Annap/Pr. Fred. Phone ERPIP (1 copy)

Book (1) 4D F:

ERP (1 copy)

Emergency Desimetry Log (1) c Persennel Mcnitoring Record (1) 1 Computer Instruc.icn Book (1) c

. EMARKS:

d t.:

a

~

INVENTORY SY:

DATE:

REVIEWED SY:

CATE:

73 l 'i

..i a

q et s

.q 1

Mr si i

j 23

.l

, 3.c.,g,,,

t 3

ERPIP APP. 3.1 Rev.9 i

TABLE 9 i

NORTH SERVICE SLPLCING l

EMERGENCY EOUIPMENT 'NVENTROY h.

RAD (AC INSTRUNEENTATION & ACCESSORIES 7

i 5.N.

CAL. OUE DAi c c ATT. CK.

SCURCE CK.

j t

6:

j E-520 s

J PIC 6A 1

Cs-i37 Sc~urce 4

i DO51 MET 5Y CAL.DATE' Z-Self-reading Ocsimeters 0 - 200 mR (3) 4 Thermeitminescent Ocsimeters (3)

Ocsimeter Charger (1)

~

SA t i:RI*3 (Change 2nd. 2 ath. Quar ers) h).

"C" Ce!I (2) 9 '/ci:(2)

"AA" Cell (2) i

n..C i =_e_ i 6 /=_

w L m._aA=.

i N

. _ ~

j n:mciete sets :I An x u.c:ning v,a)

d-f ace Negat:ve ? essure Respiraters (3) j Scare.:ll:er Car--ic=ses fer Respi.mters (3)

}

M5A-015C3A vitn 5ct.ie (2)

Space Air 5ct.ies fer M5A 20 L 5CSA (2) i j

Masking T3.pe (1 Rell) i REMARX5:

f i

4 g

.y. v = N. 6 w q v. a v..

w.2.. e_

s

\\

s p.= ~.;= 9 2y.

m..a.. =_

23.

wy y *,*.**-

  • *y t f. - - y

-wvmp_,7 y.gyy*

y e-.'s.-

Q gy cr g,

e*

s.

ERPIP APP. B.1 Rev.9 TABLE 10

, h EMERCENCY EQUIPMENT IN REENTRY LOCKER (45' LEVEL) m INSTRUMENTATION & ACCESSORIES I

S.N.

CAL. DUE DATE BATT.CK.

SOURCE CK.

i, PIC-6A E-520

- TELETECTOR p

HI-RANGE METER RO-7 m

I PRN-4

~

I i

DOSIMETRY & SAMPLING EQUIPMENT s

Personal Alarming Dosimeter (2) r3 S.N.

BATT. CK.

S.N.

BATT. CK.

Individual Desimetry Packets (10) 9 (5, 50, & 200R SRD's; Special Desimetry) l Desimeter Charger (1)

Lapel Air Sampling Unit (1 Set)

Desimetry Fcrms (1 Set) i i

1 j

PROTECTIVE CLOTHING & MISCELLANEOUS 3

j Anti-C Complete Sets (10)

Stopwatcn (1) i Neg. Pressure Respirator (10)

Plastic Overalls (10)

Spare Reso. Cartridges (10)

Rubber Overshoes f

Lead Blanket (2)

(10 Pairs) i ERP!P Sec-icn 4.4.7 & 3.3 Lead Gloves (! Pair)

s

]

(1 Set)

Tape, Masking (2 Rolls)

J D,

(Teudmcu-hs (10) 4 25 -

.=..c.oLo A.a.o. 3.I Re v.' 9 0

E TABLE 10 (Continued) 1 SA: i: RIES (Change 2nd & Mn Qua ters)

,J '

9 Volt (2)

~

"O" Cell (2)

"C" Ceu (2) s, "AA" Ceu (2)

RE.tLA.RKS:

e

[NVENTORY SY:-

~

DATE 5'

l REVIE'#ED SY:

DATE A,,_6 c: cersen ceder ning -he review should be ne h.rst !!ne suc. erviser of :ne e. ersen c. ed:rmine :he

=

inventcry.

hr ;.

i t

i i

\\

G q'

r.

- 43

- m 3.-n-y,;- z... _.,. ~..; ~~;..

.p_- y

,.7y gy
p3mp, y y y

y_

y,,

ERPIP APP. 3.1 Rev.9

\\

  • f

.i p'

TABLE 11 j

MEDIA COMMUNICATIONS CENTER

+

l EMERGENCY EOUIPMENT INVENTORY 4

r

- NOTE -

i

]

The following listed equipment is stored at the alternate

.y.

Emergency Control Center and is to be moved to the Media Communicatiens Center in the event of a declared emergency.

]

COMMUNICATIONS & MISCELLANEOUS EOUIPMENT c

i Portable Radio (1) S.N.

Operability Check'

,f Radio Antenna & Mast (1) 16 x 12 x 12 Metal Box Containing Radio Accessories (1) s 1

Multiplex Microphone Mixer w/ Assorted Electrical Gear (1)

(Housed in a Podium /Cacinet)

{m. -)

' Foot Lockers (2)

OFFICE EOUIPMENT & ADMINISTRATIVE AIDS

i Savin Copier (1)

Per able Typewriter (1)

Operability Check _

Operability Check Pertable Telecopier (1) -

Paper Shredder (1) i Coeracility Ched<

Operability Check t.

0 EPZ Map (1)

ERPIP (1 Copy) ll Rev.No.

CCNPP Flow Chart w/ Stands h;

(2 Secticns)

-t ADMINISTRATIVE / OFFICE SUPPLIES

[,

Clipcoards (6)

Scissors (2)

J Pens (13)

Pencils (13) s o

i. 3" Rulers (2) 5tapters (3) a'!

d

i

} }

1

.._,.,.--,--.,.-..7.7.,-

-~y 7 e

,-,y-------.

r.y,.

Rev.9

i n,

..p u

T TA3LE 11 (Continued)

).

~ ~ Tace Discense-s (3) 5taples (3 Scxes)

Tace,5ccich (3 Rolls).

Rescer Sands (2 Boxes) j

,}.

q

?acer Clips (5 Soxes)

Paper Clamps (J 5cxes)

.}-

N 31/2 x 11 Lined Taclets (LO) f*

9 x 3 t/2 Notepads (6) c.

d~

6 x 4 L/2 Notepads (6)

Manila ?ctders (20)

{f 31/2 x 11 Cnion Paper (t ?kg.)

3 t/2 x il Send ?acer

[

(1 Okg.)

i.

Envelopes, t x 91/2 Whi e (LCO)

Enveicpes, 9-x 12, Seewn (100) g, 1-Enveicpes, LO x 15, Srewn (100)

,.,.s

(

5AVIN CO?IER 51.!?? LIES:

Dispersant (2 Sot.!es)

Tener (2 So:-des)

~

31/2 x 11 ?acer (3 ?2cks) 3h j'

3 t/2 x it Pacer (5 ?scks)

Xerox 200/2LG Te ecccier ?2cer (1 Sox) i R J,iARK3:

d 4

a f,

e P

i

(

LNVENTCRY SY:

OATE E

g I

o., eyI--, =-an av.

C.m*~.'.

8

\\

(

5

- g I

i:

h i

i P

E r

.e l

.,.,.,. n.,,, g,,,

4 ERPIP APP. S.1 i

Rev.9 4

t 1

TABLE 12

,q SOUTH PROCE.SSING BUILDING

~

's EMERGENCY EQUIPMENT INVENTORY

~

m r

i DOSIMETRY CAL. DUE DATE 5,

1 Kit Centaining:

iLD's (100) l SRDs 0-200 mr (100)

Dosimeter Charger (1) j (with extra batteries) j Emergency Personnel Entry Forms (1 Pad)

~

i PROTECTIVE CLOTHING & MISCELLANEOUS i

Anti-C Complete Seu (32)

Neg. Pressure Respiraters (32) m (qjpare Respirator Cartridges (32)

Radiation Tace (2 Rolis)

Masking Tape, 2" (2 Rolls)

(Replace During ist Quarter)

Mocile Emergency Mcnitoring Klu (3 Kits)

(Fer Centents Censult Table 5)

REMARKS:

4 i

1 INVENTORY SY:

DATE REVIEWED BY:

DATE

~

4 i

NOTE: Person pederming the review should be the first line superviser of :he person who pedermed

ha inventery.

i e

I e 5

}

'd i

1 4

29 -

i

~~~~~'Y"~~**,~7"';**T~~"'~~~

~~~ M ~ " '

}

..,-n.,..;g...

---a~

.r--~

r-

~

ER PIP App. 3.1

)

m... 9 l

4

_, a., :_

,2 m

,I

.=..

E'.iERG ENCY. 9L E FICMT'NC EOU!P'.1:N T LOC ATED IN TUR SIN 5 3UII.OINC FR E N3PECEON UNIT

// R EQ'O

!/ FOUNO SMOKE EJECTCR5 Each 3

?RC TEC TIVI e ' O TI-i!NG Eaa

!0

,:_ c_u TR.,C R :_,

cacn 3

.-O AM a-C :,R a.

l v

cac,

+

R E33UR E 0 :_M AND Eao a

EX ?ANCOL FO AM ac

!O d

UCU:0 : CAM Eac 5

i p :.,__

.a P4,....O t i ' ca cac 5

w.

p 4

..~e. O L,C 4

.aa a

w i

.c

-G AM OUCT Eac

.. m y.s u - :

m ---

2, p

-c e

CCCR 5AR Eac L

c i

[

.-.:. :. :.+ y.e y. :y. _u m,

e :,

nv

-w l

ORC:31.E INMY 3AR Eac I-8 RY 3ARS Eac

- s --...a z

.= C v.%....

r s

.dc

\\

  • d'%

h?d*

-.. ~. -,..

w..

-..,.,e7f v.ww e - vvg. * ; s= ~ - <{,--

    • "f,t.*. **'
        • '**J yT*'"

v 1

v p{.,' s}e f p p [] i g

') j ERPIP App. 3.1 i l ar7. 9 i j I i==- TABLE 13(Continued) ,'] } EMERGENCY.:RE FICHTING EQUIPMENT LOCATED IN TURSNE BUILOING j FRE NSPECTION UNIT

  1. R EQ'O # FOUND

~ h,: 3 GATED WYE Each I J DOUBLE. EM ALE Each i A e L!?T RO PE Each 5 b NO.ZZLE I 1/2 Each 2 ~~ l SPANNER WRENCH Each 4 ~ 2 s j BOLT CUTTER Each L i FRE AXE Each I i i. REDUCER 21/2 de 11/2 Eacn i 4 l NVENTORY SY: DATE: 4 1 i REVIEWED BY :I _ O ATE: ) l. Person performing the review should be the front line swerviser of :ne cersen performing the inve.tcry. 14 e l'c l1 l _ v] f pr- ! s _,,.y_.., ,g.~- ,....._.j7 '";q ?EU7 " ""' " * ' ~ ' ' " " 7 'O ~ "

  • I

,4 e w w-- w-A '

g 4 C R.0I.0 r'..p c. 3. A t Rev.9 4 TABLE 14 i OFFSITE MOBILE LAa - !3 FT. TRAILER 1 EMERGENCY EOUIPMENT INVENTORY s' E 1 I LNSTRUMENTATION & ACCESSORIES ~ I 5.N. C A L. D U E D A. T E BATT.CX. SOURCE CK. ?!C GA P.C AA j i RO aA i 1 I RO-4A .i +J RO uA -) J E $20 1 ~ PRM AA/AC-3 ,\\, RM-la 4 l RACECO AIR SAMPLER -s 1 4 +-) 1 en. THOMAS AIR SAMPLER '~ 55 v.u.c.la::r u-i a i CCSIMETRY ECUIPMENT CAL DAT'5. ~ l i~.0 5 cec 215 (20 ?k:;s. w/75 Tks) 75 T* C's. 20.:-r Metcer (3) 3 j 3RD 3-2CCmA (3) 3RD 3-JR (J) 5E O 0-JO R (j) 3RD MCCR (J) ..4 ] Oestmeter Charger (2) \\ d .u....u.er r.y c.y. m.. _ e.m.u. - r Suve-L.cii e Car. 00) 5cc:- :2 ars :ic 5 exes) Op "9 sce.:n:ers (i acx) Mini:cre ru ers 'I 5cxes) b i 1 k J,- s .+ a m p a ' ,e.e+ e g e se ee > =-+e 4 - 94rd. t ,w n m.

    • -,*'et-

. ':" f-or

    • "g

) D

'l ERPIP APP. 3.1 e' Rev.9 TABLE 14 (Centinued) ln ' PROTECTIVE CLOTHING .} l Anti-C Complete See, (6) ' ~ Rubber Gloves (50 5ets) Cotton Gloves (50 Sets) Paper Suits (1 Box) Neg. Pressure Respirators (10) Spare Resp. Cartridges-Ei (10) . Smoke Tubes (2 Boxes) i 1 l BA i i CRIES (Change 2nd. 6: 4th. Quarters) d a ~ ~ ~ { 9 Volt (12) "D" Cell (24) 71/2 Volt (12) "AA" Cell (24) 1 MISCELLANEOUS O 5Ga1.eoiy s.1e a) xnives (2) Rad. Rope (1 Roll) Tweezers (1 Sox) Survey Maps (1 Set) Clean Tags (1 Sox) j All Weather Caution Signs (15) Caution Signs (10) >j Hi-Rad Signs (10) Sign Inser s, Varicus (10) l Flood Lignts, Pertable (2) Flashlights (2) i Extensien Cords (5) Kaydry (5 Soxes)

1 MS 260 Spray Cleaner (3)

Masking Tape (a Rolls) i .} Green Tape (3 Rolls) Lead Blankets (6) 'j

{

PLASEC BAGS: 1 l 12" x 24" Clear (25) 24" x 40" Yellow (25) 5" x 7" Clear (LOO) 39" x 65" Yellow (10) >l Heaters (2) j {=>SADIO (1) l Operacility Ck. j Teol Box (1) 1 1; 1 33 i )n -

ERPI? A??." B.1 !~ Rev 9 J TABLE 14 (Continued) ADMINISTRATIVE /OFRCE 3UPPLIES Pens (1 Sox) Pencils (1 Pack) 4 Bik. Markers (2 Soxes) 31/2 x !! Paper (4 Pads) 9 x 51/2 Notepads (2) Legbooks (2) Manila Felders (10) Clipbcards (4) Tape Dispenser (L) 5cccch Tape (1 Roi!) 1 5: apter (L) Scaples (1 Sex) j L2" Ruler (1) Paper Clips (1 Box} he s j Paper Clamps (1 Sox) Rad.. Safety Precedures .1 (1 Copy) Mcbile Lab Systems Manual (1) j 4 REMARK 5: t

l i

q n j IN'ENTORY SY: DA ~E 1 REVIETED SY: DATI i i l i 4 f 1 l o .'l o } 1 O 2 h ,9 .sJ= 3 4 rie*p-ergm**-M e ens---m.-- e- >-, * - y e s-

  • - - -s;-g -agpm e g e,

,,9 9 9,. -+-e -w.e-ey==g-a+ s y =e w ,-==t 4 m eqP -.P 846 =

r ERPIP APP. B.1 Rev.9 TABLE 15 20 FT. TRAILER (MOBILE EMERGENCY CHEMISTRY LAB)' l (.h EMERGENCY EQUIPMENT INVENTORY j INSTRUMENTATION .k. l S.N. CAL.DUE BATT.CK. SOURCE CK. i ) PIC 6A t l PIC 6A - i -l E-320 } E-520 ~ ~ L PRM 4A/AC-3 i RM-L4 ~~ RADECO AIR

(

SAMPLER f l' i THOMAS AIR p SAMPLER j Q' l TI-35 Calculater -l SAMPLING ACCESSCRIES t' l Zeolite PUters (30) Scot-PU:ers (2 Soxes) i Glassfibre Futers (1 Sox) Millipore Futers (2 Soxes) 4 i DCSIMETRY ECUIPMENT CAL.DATE i TLD Scecials (20 ?kgs. w/WB Tids) I WB TLDs, (30) SRD 'a - 3R (50) SRO O - 200mR (30) V SRD 0 - 2CCR (50) SRD D - JCR (30) 1 Ocsimeter Charger (a) !, 6') a 1 - 35 .--._.r--......,, s. ,c_.---.. .,, ~ ~

ER.otp Apo, 3,1 Rev.9 t {. TABLE !5 (Contint.ed)' . ROTECTIVE CLOTHING & ACCESSORIES h Anti-C Complete Seu (0) Rdber G1cves (30 Seu) j Cotten Gloves (30 Seu) t . aper 3uiu (1 Sox) u Neg. Pressere Respirators (10) Scare Resp. Ca.dridges (10) i 3CSNs (2) Smoke Tutes (2 Soxes) Scare Air Go::les 0) I BATTERIES (Change 2nd. & 'etts Quarters) 3 9 Volt (12) "O" Cell (2'+) ~' t t 7 !/2 Vol:(2) "AA" Cell (24) COUNTING ICCI? MENT icil system u/ Cave (1) s TLD Reacer (1) O'- v MISCELLANECUS t 1 J Cal. Poly Sot-te u/Vr.: (1) Knives (2) 9 Rac. Repe (! Rei!) 5 i Tveezers (3) Survey Macs (! Set) Trash Can (1) Rasnlipu (2) 4 <j MS-250 $cray (3) iCef*s1Cn Cer0S (3) e KaVCr*/ ($ 3cXes) i i q Mask:ng Tace (3 Reils) Leac Stanken (6) Creen Tace (a Reils) Mar ? late (1) ~ i j Isol 30X (i) Hea:ers (2} 5 IONS: .i l aCka*. ion 3i.s (12) f Mif. RaC.A rea i. !2} h 4 } i (

  • ~ '

t 5

  • -++-,em e e w

.w-w., +.,.-#.+, ~.g, ,gp..- ,.+,ww. eg we

ERPIP APP B.i Rev.9 1 ' l TABLE 15 (Conticued) O Centaminated Areas (12) Radioactive Material (12) Airectne Radiation (12) Clean Tags (1 Box) i PLASTIC BAGS: ..m 12" x 24", Clear (30) 4" x 3", Yellow (100) .i 5" x 7", Clear (100) 39" x 65", Yelicw (10) - RADIO (1) Operability Ck. 1-4 ~ i LABORATORY SUPPLIES. I Orion Ionanalyzer (2) Fisher Thermix (1) L&N Conductivity Bridge (1) i S.N. CAL.DUE I g-jiasks (2 Soxes) Pipettes (3 Soxes) .a o Rcagents (1 Sox) q Sm. Clese Nalgene Sot-les (3 Bags) Lg. Clear Nalgene Sot.les (1 Bag) ! I j Srown Nalgene Bottles (1 Sag) l >? ADMINISTRATIVE /OF ICE SUPoLIES i i ~ Pens (1 Sox) P-ncils (1 Pack) i Stk. Markers (1 Sox) 31/2 x il Facer (4 Pads) 9 x 51/2 Notepads (2) Log Sooks (2) Manila Folders (10) Clipboards (a)

3

't Tape Discenser (1) Scotcn Tace (1 Roll) i Stacter (1) Staples (1 Sox) '1 ,m (2d Ruler (1) Pacer C11ps (1 Box) i

)

3- - l ~~ n-vn m m r-, ; r e - m ...-...,-,~:- m n : -,-- -

ErdrA# APV. 5.1 Rev.9 TABLE 13 (Centinued)

  • '/

i Rad-Saf ety Procecures l Paper C! amps (1 Box) i (1 Se:) .? Pacer Rolls (Fer Da:a Terminal (2) i Casse::e Tapes (3 Ecxes) ~ i RCP's (2 Socks) 2 Mocile Emergency Respense Lab Manual (1) e 3EMARMS: .j a.- N ~- LNVENTORY SY: DATE REVIEWED SY: DATE i

j)

. i 1 ii 1 i t t t- 'l - 33 ~ ' ?E ~1 -- - 'i I" ' ~ ' " " ' ~ ~ ' ~ ~ ~ ~T ~~ ' " ~ "' ""?*~~" *W iT "rW

s ERP!P APP. B.1 Rev.9 TABLE 16 'O PORTABLE RADIATION SURVEY INSTRUMENTS AIR SAMPLERS AND DO5IMETEoS FOR EMERGENCY USE ONLY 7 i LOCATIQN_ TYPE!OUANTITY 69' First Aid Room E-520 (1) l Calvert Memorial Hospital Pic-6A (1), RM-l4 w/HP-210 (1) C.ontrol Room Pic-6A (2) MS-2/SP A-3 (1) Air Sx. (1) A.C. cnly Nor:h Service Building E-520 (1), Pic-6A (1) 3 Primary ECC (South Service - ~ PRM-4A (1), MS-2/ SPA-3 (1), E-520 (1), 4 Builcing Pic-6A (2), Air Sx. (1) A.C. only i Alternate ECC (Farm E-520 (1), Pic-6A (4), F.M-14 w/HP-Demonstration Buildirg) 210 (1) MS-2/ SPA-3 (1), RO 4A (2), c 1 PRM-4A (1), Air Sx. (1) A.C. only 1 l

  • Mobile Kit 11 (South C/H)

E-520 (1), MS-2/ SPA-3 (1) Air Sx. l (1) BN type, runs off car battery j (') Reentry Loef<er (47 Turbine S-520 (1), Pic-6A (1), RO-7 (1), Suilding) Teletec cr (1), ?RN-4 (1) OSC (South Service Building) E-520 (1), Pic-6A (1), RO.3 A (2), RO-2A (1), Air Sx. (1) A.C. only - I f if Mobile Lab E-520 (1), Pic-6A (1), RO aA (4), j PRM AA (1), RM-14 w/HP-210 (1) j A.C. Air Sx. (1), D.C. Air Sx. (1) } 27 Mooile Lab E-520 (2), Pic-6A (2), PRM 2A (1), j RM-14 w/HP-210 (1), A.C. Air Sx. (1), i D.C. Air Sx. (1) 1 - N_QT_E - + Mobile Kits 14 are Identical i i i Y i' .I. 4 30 1 4 i m.._._.. _,,_ m.m. -. m.., .~.,

ERPIP A?l2. 3.1 Rev.9 ) ~iASLE [6 (Centinued) i i s O~', i. Tc:al Amcun: ef Ec.ui: ment for ER?!? t ] RO-72 E-520s Pic.4As R m- !4's MS-2/ SPA 13 A.C. Air $X's D.C. Air SX's 4 1 13 13 'a 7 6 6 s t a I .RC-2As RO 4As ?RM 4A/AC-3 Teletec ce ?RNA I .L 3 4 L L 4 TOTAL AMOUNT OF OOSIMETRY FOR ERPt? a .~S 'PD TLD' e i LOCATION (C-200M R) (0-IR) (0-!R) (0-JCR) (0-20CR) t ] Small Trailer 5 0 5' 5 3 3 'v3 l Lar ge Trailer 30 0 50 50 50 JO T3 2 20 5pecats }.'~NcrnServiceSieg. 3 0 0 0 0 5 ,.t'. - . u 53' Fi.m Aic Rcom 0 0 0 3 0 0 Calver-Memer:si 10 0 10 0 !0 3-Ring - l Hesci 21 ' 0-W 3 Convci Recm !0 '0 0 0 3 10 T3 if Reen : /-L:cuer 0 0 LO '!C !0 iJ 5 ceca! -i Fr mar / ICC 23 0 0 25 23 2 l Mecde XI: (s) //! a 12 0 0 0 L2 L2 '73 A!:erna:e ECC (Parm Demo) 25 0 0 25 25 25 '7 3 Scu:n Oa:e Sec:. y iGO O C 0 .00 75 t Oper. Supccr, Center 50 0 23 23

3 10 T3 20-Service l

JC-5pecals '6 I h

s 4

20 - 7'. m _,..n,.m. . ;- -- 7 7,.3p,, ,., y.

ERPl? App. 3.1. '. i .U7. 9 i s 1.. o l TA BLE 3.1-1 ?otentiallv Ava:!acle Resources ( ?;M Utili:V Ractotectc31 Emer2ency Res:ense Ca acilities j H. ?. I R&OiOCnem ?t sCE*.e! i Ecyt:m en: J.vaila3ie scr Ressense o A..ctner ?]M t ::t::v 's i O 5 ? 5 C 6 M M C N 3 5 C I- ! I-2 C E 5 5 A. Persocce! i. . :. P. Seoervisors 3 3 2 2 5 2 3 2'. H. P. Tecns 6 6 5 5 20 5 to 3. Radio Chem I O O O Suservisors 1 2 2 2 Radicchem Tecns 3 2 3 2 2 2 I ' 3. - Engr.-Eff!. Ass. 2 4 0 ) L t i 7 6. "'i O Reader 2 1 0 t t t t 7. EE-RMS Specialis: 1 I L 0 1 0 t 3. Security Sgt-1 0 2 9. Securi:7 Officers 3 .O i .w,. S. Racia:icn Detection Un.:s! & 2 Ecu pm en: Combined 1. Survey Meter-Hi 2 20 0 L2 5 3 '7e-v.d /" 2-Survey Meter - Hi-Telesccping LO 4 5 0 f. 3. 5cteey Meter-Lo 10 5 3 2 !O 3 '4. SAM il 2 0 a 2 !+ 5. Portacie Celi 0 l l l INai 0. 6. Shield for GeLi 0 t t L 0 7 Compu: r & Cutput for C L l 0 3 GeLi 1. uR.hr. ra:eme:er 0 0 0 0 0 &.scorder 9. RM-!: ? risker 2 !J LO 15 5 3 !O. Air Samoter - 5 5 3 6 2 2 lo vol. 5 5 3 6 2 2 l 11. A:e Sampler - .-i vol IC 10 5 3 2 2

2.

Cas Sam:ler 2 0 0 2 2 0 i M:eIa:er Celi 2 0 0 2 2 'O Analysis) 13. ?ccket Dosimeters 300 200 LOO

00 20 200 14 Propor
icnal Coun:

2 0 0 l 0 15. Uc. Scin:. I 1 0 0 0-0 ! 6. Scaler. Timer - Detecter 2 1 i 0 i ! 7. Sniel:s f or aoove 2 l 0 0 13. Rad acs 0 0 0 24 2 O ! 9. len Telemetry 0 0 C i 0 ( . d m -:)- --.; -. ; mp. y .M.. q- ~~~ ~~ m:}~~' ' ' "^} ~ ~ ~ ~

r ER PIP Aco. 3.1 ny. ? TASLE B.1-1. continued Potent:allv Avadacte Rescurces ?- P2M Utill:v Ractcletical imerzency Resconse Cacabilities h H. P. & Rac:cc em ?ersennef & Ecutement Avana,te ter Rescense to Acc ner ?]M U tutv ~ i T 0 S P S C T M M C N S S C I-! I-2 G E C. Vehicles Cembined S S 5tation Tagen or 1. Truck er Van I L I I L L for Survey Team 2., 110 genera:cr 0 0 t o 3. Inverter f or 4 0 L 0 L L i vehicle cattery 4 GeLi Ccunting 1 0 'O O I I Lab Van a' 5. Seta Counting Lab 0 0 0 0 0 1

6. ' Wind Speed &

I O O O O O ~ - - Direction Indic. D. Sucolies Uni:s 1 & 2 Combined 1. Coverall & Access 2000 1000 500 500 0 s set 1000 2. Disposable 1000 1000 10(,0 0 200 200 3. Rainsuits 1000 500 50 200 250 ,I 10 gf' 4 Respira tors 250 10 0 150 10 0 LOO 100 C '),- 5. Respirater 200 t000 500 400 200 .!00 s Cartrieges 6. Iodine Sampler 10 0 50 0 200 200 25 0 100 Car ridges 7. Silver Zeolite 10 0 20 0 0 0 0 i Carvidges 3. 50 gal. plastic 2000 5000 500 50 0 2K 1000 P bags 9. Decen Kit I 0 0 0 0 (skin) 10. Acsolute Filter 6 2 1 0 1 0 { Vactum Cleaner 11. Filters !cr amove 6 2 l 0 2 0 7 12. Rese. Test Secth 1 0 0 0 0 0 l 13. SC3A (4.5) 25 !O 20 6 5 10 12 SCSA Tanks 25 10 20 6 !O 30 i 15. Port Air Comp 0 1 0 0 0 16. Clove Sox for j Sample P ep. 2 0 0 0 0 17. Lead Sricks 200 0 20 0 100 500 13. !/ft' Lead Sheet 50 4xa x1/4 100 l'x2' 10 la 20 !C0 .s !9. Lead Slankets 100 0 23 !S 10 0 i _

20. Air Sample pacers 10C0 1000 200 200 500 LOK

' *n 21. Raciacwasn-gal. 35 0 0 53 35 3 22. Rad Cal Scurce 0 0 0 2 0 23. Misc. Sec. for Lac I O O O "OU:p. 1 -:. L-1 w, g .,p. MM MgI** W j

__.____u n .4 -,g A.p a3p. *3.. Lt .j

7. 7. '.

C. i e e' l 1 l l oe -I N l I I 4-N ! 2 i i 1 i i: om l } -e e ., -< p) l UU .t. C ae l =c .= i l lX q-7 U.a i i =v e ~

s. V

,t e = v = ,M. c=% - t - =. l _ 4.J cC 4 1 i. i- .e. c "- 5 >., cf

  • . =

.-= !Z e 74* ^ 'lll'. % .I s ii s s... _-,"E ;- : :? ' e.- - I C. I. to. .t. g- _= =_ .. e u _,... _ - _v e 6,. .o,, = m s. u y. -s. - h8 m, I e -3 * - E s- : s E u f. gS =- \\ e ~

u. : 5 38a s.e.

u = .e. s c ~ v 1, a x^ e tsn s. a. ae 35.!!

c.

... a. a. o c>- vv vv

m..= =.

=. e ':.. o b ~ bb O E =.= b b -c. ~ O ,t i =. - _ s =. w ':Oge ~ ,~ = .l V i e-3 0 e < G$ a. m < sd > 60 I l . i 1 m e =~ .~ = =- = e. ~ ~ = a -u = -. ~ ~-. ..Ms 4 as-

a. v

=e s d.= :. 'E, ~~ m o o t m Eq~ wge g

=

p g

e. m o~-

o85l 8 i E-df E 5 ss 8 =. R 8 ~o ~ ,%R_ 1 z ~ os~~~ n r-i. -o 4 j --O o' c' o' coc'co c' u o C ococo - I . i. ./. d o 9 -<z u... n u -y y .=.= _a v-= = .c o c a z I m:= z z ~e z. . <.c 5 e ~ )I a.s W. zl l a-g 4 o J ,,,p = I f ( I4 .r pe 2 *.. =. .M w - e. X..gl; e t ~- ~- M e ,I v.,. f <t l A. w .'M. ' .n. y s b qu/ p., =y ~n .<r

5. m 3

.M. I ,,..=,,.r. e s s e m. 8 4 t 8 .n. .i .= G - f n e>

u..
u...

u u .. = - c ;::.= = s 3 s l -t A i t i ,l .t = 5 =- g 6 zi g e.=...[ w l a .:. g .3 k ?: i f X<2! C i l. 2 h, E.. "'. 5 _ h.. = w 1 ...c =c e -.o - =. s. e e e e .w .u. J. J

  • ...,C,,,,%.:.

O ;,: .s: 4 . =.. = c.*,,- 4 }. e e . y ..e 4 rs r= p -w w U. zW m-w t ~5 ^ u .= u t .z.. ...c .Q l g.c .= i. ,= m .= 6 (- J

g. -

.:ll x ec i 1

== e g h s.-l { ~ 3 @ h l. 0 l

  • 'm N

~ t i l ') j 7, l 21~. N ,j. l r.s, .y a, ,4,,, w c,.' '3 3 y . e I .s: j e { w." l =-{ 8 e.i. 4 l .n1s 4 = g.- I i l l 4 i 'I 4 b f t 4 l =g emy e, m;**"".~T**'l.5*"l-'"""T***""* *'~~7 I* ~

e. +r-g t.

O + im g ERPI? G? 3'. L wa'~ral G?W;td. t 6, I ,1 REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT CATE EPU SIG/DAT?. .M TG /OATE 0 0 b' S */N % n s, ; (; a $ 0 3 -0 4 0 f f, J lc)' 3 7 3 /

j e

s-e i I { t

  • p([u-3 i

4, i I l 1 t i t i l f. i I l i* = 1 l l 5 n j eg l I I s =b ,i'; 4 -,7 ..-- <~*

      • "7 M**

-. ~^ ... L , ae.

V .T.3 3 7 3 4m. e. 1..' e p 2 T[ e Q .w o e e a a

  • e p

a e e C.. emon. .~e- ,R.et = Ly y e* m.. a. .em

9.,

u e :.:....:: m u_. a.m.CT ua-.> C S a-. o. r a_v 4 tv_er_v_iv. A .c.,J

2..J..m,._..,. : a L s-.
m..

.e.---. o.1.v- _ - a

s-> - >, AG.-

Le. s. -.~L= r.2 , e. ~. 1 9 23 9 2' 9 24 9' 4 3 e, ?.J a. i i 4 9 25 3 4 ~~ 5 9 27 9 f ,a l s 2 \\_ t 3 9 30 7 .th - 3 9 n 9 to 10 9 32 9 3 30 9

  • 1 a

98 9 &q ]J 7 Jw 0 'A e< a f b'

  • b 0

+4 3 ' C. } ~' ~ 9 ) ,y 3 e* .C 5 .o -Qw 9-9 - me> e p w b e= ws = . - = + * =s t

      • +-N*-
    • "V**

""'W'"<***4i,7'"'M*""***T

          1. 9P"*'***

O October 29, 1982 To: Holders of ERPIP Manuals From: J. M. Moreira Subj ect: ERPIP 4.5.1.1 The purpose of this l'etter is'to cancel ERPIP 4.5.1.1, ALERT: PROTECTION, ACCOUNTABILITY, & EVACUATION. ERPIP 4.5.1.1 contains duplicate information detailed in ERPIP 4.1.21 i Assembly Area Leader Checklist.- g/ w [vl{tt Mr Ch V Supervisor)'- Emergency Planning l l l l $ fb POSRC M / /Ob Plant Superintendent JMM/TEF:sab , T "*, l l =

3, s .. s c j-I (Oi w ,un d l%,, ^ .b_ To: Holders of ERPIP Manuals J j From: J. M. Moreira i i l

Subject:

ERPIP 4.5.1.2

i i

~ The'. purpose of this letter 1s to cancel ERPIP 4.5.1.2, SITE EMERGENCY: } j PROTECTION, ACCOUNTABILITY, AND EVACUATION. } l Information contained in ERPIP 4.5.1.2 has been incorporated in ERPIP's for Assembly Area Leaders, Radiation Protection Director, and Security Team respectively. {} b 2d R i errisor - Emergency P1 . ng i l 1 s s )'s 65 POSRC .4 4 ) J-I4wJJ Plant Superintendent t i , i. ,n0i/TEF:sab 5 i- %J t 1 i '*'#^~* " % :W U ---w ~*-e ' ~ ^ ^ ^^^~~.C"~* ., ~ g ;-e, e ,, m- ~ ~ ;-m _ , m -<w 3.:

3r s

i

D,

. s

  • ~

n j _-J.m 9 N T:,3 / l 1 To: Holders of ERPIP Manuals From: J. M. Moreira

Subject:

ERPIP 4.5.1.3 The' purpose cf this letter is to cancel ERPIP 4.541.3, GENERAL EMERGENCY: j PROTECTION, ACCOUNTABILITY, AND EVACUATION. i Information contained in ERPIP 4.5.1.3 has been incorporated in ERPIP's i j for the Radiation Protection Director, and Security Team respectively. ) t 1 i [ $U b l ,Stiprsrvisor - E:nergenc%ng 1 55 Ci POSRC i L/ Plant Superintendent 'I e JMM/TEF:sab t e 4 9" b ') L- _c~._..-__,._,.,__ 23 ,7**

  • * '^ ', *.,

.s ,...f ,. c >1O t t-f -da.41 i /T.T,.3 I l .=, To: ERPIP Manual Holders 1 From: J. M. Moreira

Subject:

ERPIP 4.10 i The' purpose of this letter is to cancel ERPIP 4.10 EMERGENCY SECURITY.

)

The information contained in ERPIP 4.10 is incorporaced in ERPIP's for I I i Security Team or is detailed in the Safeguards Cuatingency Plan. i s s 2 S isor - Emer lanning ,30 4 l T3 Cf POSRC I l Plant Superintendent JMM/TEF:sab e 1 O A l ch 's. 3 4 1 3 s,____., _._..__...._s

_m v' ..o l m) i O i. (141 Y /Y. $ t' r To: ERPIP Mat.:a1 Holders ) From: J. M. Moreira t

Subject:

ERPIP App. D. 1 The~ purpose of this letter is to cancel ERPIP App. D.1 RESPONSE TO MfS. j Information regarding response to alarms is detailed in the Safeguards ' ~ i i Contingency Plan. -l4 .c .b. W & 1 Supe 'isor - Emerge, Planning h ~ "1 E 65 a POSRC n 4 i Plant Eperintendent P I JMM/TE7:sab i Li f e h I -4 i ~., \\~ ,} .. ;._ 7 7, 3 -. --- w y, .;,,.~.--.,.-~..- - -, .7...y..

i s 6 4 *** ) 1 ~ 1 & 4 in:3 s J .l To: Holders of ERPIP Manuals -} J. M. Moreira From:

Subject:

ERPIP App. D. 2 3 I The purpose of this letter is to cancel ERPIP App. D. 2, ARREST AND DETENTION. j j .i i Information regarding arrest and detention is detailed in the Safeguards i Contingency Plan. .h .i. Sep isor - Em Planning (.s, ) d hb 0 POSRC m ud./ Plant S67erintendent ItuTEP:sab i' j 'i. r 'a =4 J

  • %.)

.q l - 'i U q ,1 ,I i 'I ~f~ - -....... - -. _._. c-. r g...g.- ...... -... 7. o. 77c-. 7.- :

k. l (Js t l l 1 4 i 4 e o ~,ja7/1. $ I'lb l c a 1 ~ ? - To: Holders of ERPIP Manuals From: J. M. Moreira

Subject:

ERPIP App. D. 3 1 The' purpose of this letter is to cancel ERPIP App D. 3, SITE TRAFFIC .2 ( CONTROL. i i Infor~ution contained in App. D. 3 is now detailed in ERPIP's for the Security Team. a, ~. ppy,, .lanning S M ror - Emer2 3Sc( POSRC 4 Plant Superintendent I ij l JMM/TEF:sab. ,i l ) ) i. 9 N .wr .~,y----p-7,. ;,.y v ~,,., ,}}