Part 21 Rept Re Broken Engine Driven Lube Oil Pump Discharge Nozzle Boss.Caused by Overtorquing of Tapered Thread Adapter.Adapter Changed to Straight Threads W/Undercut
ML20083P980
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 04/09/1984
From: Moriarty J
COLT INDUSTRIES, INC.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
REF-PT21-84-206-000 PT21-84-206, PT21-84-206-000, NUDOCS 8404200287
Download: ML20083P980 (2)


Text

____

paa Colt Industries

['n'$n';$fefo"n 3

701 Lawton Avenue Beloit Wisconsin 53511 608/364-4411 April 9,1984 Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Ill. 60137 Attention: Mr. James G. Keppler, Director, Region III

Subject:

Colt Industries-Fairbanks Morse Engine Division Emergency Diesc! Generators Long Island Lighting Co.

Shoreham Nuclear Plant Cracked, Broken Engine Driven Lube Oil Pump Bosses Part 21 Report Gentlemen:

During factory tests of the first LILC0 Colt-Pielstick PC-2.3 Diesel Genera-1 tor Set, a broken boss on the engine driven lube oil pump discharge nozzle was discove;cd. The broken boss significantly reduced the sealing area between the pump and an adapter which screws into the boss. A second lube oil pump was examined and the boss area was found to be cracked.

l l

Our Engineering Department has concluded that the cracking or breaking was I

the result of overtorquing of the tapered thread adapter which screws into the boss. Such cracking or breaking, if severe enough, could permit oil leakage sufficient to prevent operation of an engine.

To prevent a reoccurrence, the adapter is being changed to straight threads with an undercut. The threaded hole in the boss has straight threads and need not be modified. All PC-2, PC-2.3 and PC-2.5 Diesel Engines shipped to the attached list of plants will be inspected for cracks or breakage and have their adapters changed to the straight thread design.

We will keep you advised of our progress in the field inspections and change-outs.

A copy of this report is being sent to the utilities involved.

T Very truly yours, 8404200287 840409 PDR ADOCK 05000322 oriarty S

PDR MANAGER UTILITY AL

%gjf i

JMM:jc i o APR 1o ggg4

U. S. Nuclear Regulatory Commission April 9,1984 - Page 2 cc: Stone & Webster Engineering Corp.

Bechtel Power Corp.

P. O. Box 2325 P. O. Box 3965 Boston, Mass. 02107 San Francisco, CA 94119 Attention:

Lead Electrical Engineer Attention: Hope Creek Project Engr.

J.0. No.12179 (Millstone III)

South Carolina Electric & Gas Co.

Washington Public Power Supply System P. O. Box 764 P. O. Box 1189 Columbia, South Carolina 29218 Elma,_ Washington 98541 Attention: Mr. Dan Nauman Attention: Tom Murawski Manager, Q.A. & Security Stone & Webster Engineering Corp.

U. S. Nuclear Regulatory Commicsion P. O. Box 2325 c/o Document Management Branch Boston, Mass. 02107 Washington, D.C. 20555 Attention: Project Engineer for Duquesne J.0.12241 Stone & Webster Engineering Corp.

United Engineers & Constructors, Inc.

P. O. Box 2325 P. O. Box 8223 Boston, Mass. 02107 Philadelphia, PA 19101 Attention: Project Engineer LILC0 Attention: Mr. D. H. Rhoads Project Engrg. Manager (Seabrook)

Sargent & Lundy Engineers Bechtel Power Corp.

55 E. Monroe Street P. O. Box 607 Chicago, IL 60603 Gaithersburg, MD 20760 Attention:

P. L. Wattelet Attention: SNUPPS Project Engineers Marble Hill Project Manager

.