ML20083M554

From kanterella
Jump to navigation Jump to search
Special Rept:On 950329,gap Seals Between Top of 12 Inch Concrete Block Wall & Assoc Steel I Beams Above Block Wall Were Discovered Filled W/Everlastic Column Boxboard Engineering Review Intiated
ML20083M554
Person / Time
Site: North Anna  
Issue date: 05/09/1995
From: Ohanlon J
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
93-481A, NUDOCS 9505190311
Download: ML20083M554 (2)


Text

_ __ _ _ _ _ - _ _ _ _ _ _ _

t VIHOINIA ELECTHIC AND POWER COMPANY Ricnnown,Vinorwu coast May 9, 1995 l

U. S. Nuclear Regulatory Commission Serial No.93-481 A Attention: Document Control Desk NAPS /GSS/EJW R4 Washington, D. C. 20555 Docket Nos.

50-338 50-339 l

License Nos.

NPF-4 NPF-7 Gentleman:

l VIRGINIA ELECTRIC AND PO_WER COMPANY l

liOFTH ANNA POWER STATION UNITS 1 AND 2 SUPPLEMENT TO PENETRATION ElBE BARRIERS SPECIAL REPORT Our letter dated August 5,1993 (Serial No.93-481) provided you with a Special Report identifying several blockout and sleeve type penetrati~ n fire barriers that were o

determined to be nonfunctional. This supplement to that report is being submitted to identify two additional fire barriers, representing a third type of fire barrier, that were determined to be nonfunctional. Subsequently, repairs were completed and the fire barriers were restored to functional status.

1 On March 29,1995, during the performance of the detailed surveillance inspections of

(

the fire protection system fire barriers, the gap seals between the top of a 12 inch concrete block wall and their associated steel "l" beams above the block wall were discovered filled with everlastic column boxboard. This condition was noted above the wall between the Unit 2 Cable Spreading Room and the Turbine Building, and the wall between the Unit 2 Normal Switchgear Room to the Unit 2 Mechanical Equipment Room. A fire watch was established until such time that the fire barriers were repaired using silicone foam and restored to functional status. This supplement is also being submitted because these deficiencies are believed to be the result of inadequate initial installation.

An engineering review was initiated whereby several fire barriers that have the potential for a similar configuration were identified. These barriers will be inspected on an accelerated frequency, and appropriate compensatory and corrective actions will be implemented, as required, to restore them to a functional status. Any similar deficiencies will be documented by station deviation reports. This approach is similar to that applied to previously identified discrepancies with the blockout fire barriers.

I 150061 Mp 95o5190311 950509 PDR ADOCK 05000338 S

PDR

y

)

This supplement has been reviewed by the Station Nuclear Safety and Operating Committee and will be provided to the Management Safety Review Committee.

. Should you have any questions regarding this report, please contact us.

Very truly yours, h

ames P. O'Hanlon Senior Vice President - Nuclear cc:

U.S. Nuclear Regulatory Commission Region 11 101 Marietta Street, N.W.

Suite 2900 Atlanta, Georgia 30323 R. D. McWhorter NRC Senior Resident inspector North Anna Power Station 2

..