Monthly Operating Repts for Apr 1995 for Point Beach Nuclear Plant Units 1 & 2
ML20083L340
Person / Time
Site: Point Beach  
Issue date: 04/30/1995
From: Koudelka M
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20083L315 List:
References
NUDOCS 9505180276
Download: ML20083L340 (9)


Text

.

OPERATIEG DATA REPORT' DOCKET NO. 50-266

+

t

~

DATE:

05/08/95 COMPLETED BY:

M. B. Koudelka M

y TELEPHONE:

414 755-6480 00 OPERATING STATUS ON m

K 0'

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1 NOTES
2. REPORTING PERIOD: April - 1995 g

oo

3. LICENSED THERMAL POWER (MWT) :

1518.5 QU 4.

NAMEPLATE RATING (GROSS MWE) :

523.8 gMb

5. DESIGN ELECTRICAL RATING (NET MWE) :

497.0-h

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE) :

509.0.

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):

485.0 8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:

NA 9.

POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NA

10. REASONS FOR RESTRICTIONS,- (IF ANY) :

NA THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 720.0 2,880.0 214,608.0 l
12. NUMBER OF HOURS REACTOR WAS CRITICAL 342.5 2,002.0 178,841.6
13. REACTOR RESERVE SHUTDOWN HOURS 0.0-0.0

- 667.3

14. HOURS GENERATOR ON LINE 330.2 1,988.9 175,701.3
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9
16. GROSS THERMAL ENERGY GENERATED (MWH) 449,547 2,929,580 248,474,577
17. GROSS ELECTRICAL ENERGY GENERATED 153,290 997,210 83,935,860 i
18. NET ELECTRICAL ENERGY GENERATED (MWH) 144,097 951,410 80,012,061
19. UNIT SERVICE FACTOR 45.9%

.69.1%

81.9%

20. UNIT AVAILABILITY FACTOR 45.9%

69.1%

82.3%

21. UNIT CAPACITY FACTOR (USING MDC NET) 41.3%

68.1%-

76.5%

22. UNIT CAPACITY FACTOR (USING DER NET) 40.3%

66.5%

75.0%

23. UNIT FORCED OUTAGE RATE 0.0%

0.0%

1.5%

24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

r NONE

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

NA DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED SEPTEMBER 22, 1977 i

1 b

_..w, s +

e-

,m

+-- -

x

POINT BEACll NUCLEAR PLANT Docket No.

50-266 Unit Name Point Beach. Unit 1 UNrr SIILTTDOWNS AND POWER REDUCTIONS Date May 8.1995 Completed By M. B. Koudelka REPORT MONTII APRIL - 1995 Telephone No.

414n55-6480 Method of Shutting No.

Date Type' Duration Reason 2 Down Licensee Event System Component Cause and Corrective Action 2

3/11/95 S

389.8 C

1 NA NA NA Scheduled refueling and maintenance (UIR22). Major work items include steam generator eddy current testing, residual heat removal rotating assembly work, channethead blowers duct replacement, reactor vessel head shielding, fuel transfer tube shielding, G03 emergency diesel generator Phase 3B tie-in work, modify control rod drive =~h=aiem current order timing change, degraded grid voltage relay work, steam generator blowdown heat exchanger replacement, crossover steam dump pressure switches replacement,1 A05 bus 2/3 loss of voltage logic work, component cooling small bore pipe seismic upgrades, SC-955 contamment isolation valve retubing, IRC-558 valve replacement, modify service water and component cooling supports as part of continued Bulletin 79-14 upgrades.

'F: Forced 2 Reason:

' Method:

' Exhibit G - Instructions S: Scheduled A - Equipment Failure (explain) 1 - Manual for preparation of B - Maintenance or Testing 2 - Manual Scram data entry sheets C - Refueling 3 - Automatic Scram LER file (NUREG-0161)

D - Regulatory Restriction 4 - Continuation of E - Operator Training &

Previous Shutdown Licensing Exam 5 - Reduced I;)ad F - Administrative 6 - Other (explain) 5 Exhibit I - Same Source G - Operational Error (explain) 11 - Other (explain)

PDF-CD28b (03-90) 4

POINT BEACH NUCLEAR PLANT DOCKET NO.

50-266 AVERAGE DAILY UNIT POWER LEVEL UNIT NAME Point Beach, Unit 1 MONTH APRIL -

1995 DATE May 8,1995 COMPLETED BY M. B. Koudelka TELEPHONE (414)755-6480 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1

-2 11

-2 21 456 2

-2 12

-2 22 499 3

-2 13

-9 23 502 4

-2 14

-13 24 499 5

-2 15

-15 25 500 6

-2 16

-15 26 499 7

-2 17 57 27 500 8

-4 18 199 28 500 9

-8 19 371 29 496 10

-2 20 519 30 490 m

w 4--

--+w-~

y y

4-r

-e e--,

w-7 y

-~,,,

DOCKET NO.

50-266 UNIT NAME Point Beach Unit 1 DATE May 8, 1995 COMPLETED BY M.

B. Koudelka TELEPHONE 414/755-6480 Unit 1 operated at an average of 200 MWe net for the report period.

Licensee Event Report 50-266/95-002-00, Inadvertent Emergency Diesel Generator Start, was submitted.

I Licensee Event Report 50-266/95-003-00, Inadvertent Emergency Diesel Generator Start, was submitted.

Licensee Event Report 50-266/95-004-00, Loss of Voltage Relays Not Calibrated to Technical Specification Limits, was submitted.

1 While performing low power physics testing, coming out of Unit 1 Refueling 22, a manual reactor trip was initiated because of dropped rods.

Neither the physics procedure nor the normal operating procedure allowed a restart with the control rod configuration at that time.

Safety-related maintenance included:

1.

271/A02; 272/A01; 272/A02 Bus A01 and A02 undervoltage relay gaskets replaced.

2.

1A52-60 G01 emergency diesel generator car.put to 1A05 loose lug crimped.

3.

1A52-84 Bus 1A06 feed to 1X14 station service transformer overcurrent relay setpoint recalibrated.

4.

1B52-21B power to PP-13 pressurizer backup heater Group D power panel amptector retrofit installed.

5.

1C2 personnel access air lock 0-rings replaced.

6.

1CV-371-0 letdown line containment isolation valve diaphragm replaced.

7.

1HX-1A steam generator Furmanite removed and repair of lower south handhole.

8.

HX-105A&B primary auxiliary building battery room vent cooler flushed.

9.

1MS-478 HX-1B steam generator steam header PT-478 root valve packing replaced.

. ~

y:

10..1MS-279 HX-18A1&2 steam generator blowdown heat exchanger outlet to T26 tank. inlet throttle valve cage.and gaskets replaced.

c,

-11.

1MS-2016 HX-1A steam' generator steam header atmospheric steam l

' dump control valve cage replaced.-

i 12.

1MS-2017A HX-1B steam generator steam header non-return check l

valve diaphragm replaced.

[

13.

1MS-2054. main steam dump to condenser dump control valve' trim and packing-replaced.

14.

1P1B reactor coolant pump #2 seal leak corrected.

15.

1P1B-M reactor coolant pump motor return flanges installed.

l 16.

1RC-431C T1 pressurizer power-operated relief valve trim, l

packing, yoke bonnet bolts, and diaphragm replaced.

17..1RC-570B R1 reactor vessel head vent solenoid valve control switch replaced.

18, 1RC-595 T2 pressurizer nitrogen regulator isolation valve bonnet replaced.

l 19.

1SC-955 reactor coolant hot leg sample isolation valve-packing

' i replaced and operator rebuilt.

20.

1SC-966B pressurizer liquid sample containment isolation valve packing replaced.

21.

1SI-839B-S Train A cold leg safety injection to test line isolation solenoid valve rebuilt.

22.

1SI-866B core deluge injection line isolation valve limit switch wiring modified.

23.

1SI-878C P15B safety injection pump R1 reactor vessel injection valve cleaned and packing adjusted.

24.

1SI-898 T13 refueling water storage tank local sample valve

}

diaphragm replaced.

25.

1SW-726B HX-30B cavity cooling coil outlet manifold drain valve cleaned.

l 26.

1W1A-D1 containment accident recirculation fan accelerometers replaced.

27.

Plexiglass covers were removed from 4 reactor trip breakers and anti-operation pins were installed.

28.

Unit 1 containment floor liner plate inspected.

s

- o

.E OPERATIB3G DATA REPORT DOCKET NO.-50-301 DATE:

05/08/95' COMPLETED BY:

M. B. Koudelka TELEPHONE: 414 755-6480 OPERATING STATUS

1. UNIT NAME:

POINT BEACH NUCLEAR PLANT - UNIT 2

. NOTES

2. REPORTING PERIOD: April - 1995
3. LICENSED THERMAL POWER (MWT) :

1518.5

4. NAMEPLATE RATING (GROSS MWE) :

523.8

5. DESIGN ELECTRICAL RATING (NET MWE) :

497.0

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):

509.0.

't

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE) :

485.0

~.

8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT,'GIVE REASONS:

l NA

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE) : NA
10. REASONS FOR RESTRICTIONS, (IF ANY) :

NA THIS MONTH YEAR TO DATE CUMULATIVE 3

11. HOURS IN REPORTING PERIOD 720.0 2,880.0 199,393.0 j
12. NUMBER OF HOURS REACTOR WAS CRITICAL 720.0 2,734.4 174,786.0
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 233.9
14. HOURS GENERATOR ON LINE 720.0 2,653.3 172,348.0
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 302.2
16. GROSS THERMAL ENERGY GENERATED (MWH)

-1,080,884 3,976,210 247,958,135

17. GROSS ELECTRICAL ENERGY GENERATED.

365,940 1,342,320 84,293,430

18. NET ELECTRICAL ENERGY GENERATED (MWH) 349,498 1,280,573 80,361,088
19. UNIT SERVICE FACTOR 100.0%

92.1%

86.4%

20. UNIT AVAILABILITY FACTOR

-100.0%

92.1%

86.6%

21. UNIT CAPACITY FACTOR (USING MDC NET) 100.1%

91.7%

82.5%.

4

22. UNIT CAPACITY FACTOR (USING DER NET) 97.7%

89.5%

81.1%

23. UNIT FORCED OUTAGE RATE 0.0%

0.0%

0.9%

24. SHUTDOWNS' SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

Refueling,' 10/07/95, 38 days

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

NA j

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED SEPTEMBER 22,' 1977 i

e

?

I 1

_. _... _., _... _ _ ~

POINT BEACH NUCLEAR PLANT Docket No.

50-301 Unit Name Point Beach. Unit 2 UNTT SHUTDOWNS AND POWER REDUCTIONS Date May 8.1995 Completed By M. B. Koudelka REPORT MONTH APRIL - 1995 Telephone No.

414n554480 Method of Shuttmg Duration go,o Licensee Event System Component Cause aal Corrective Action Mo.

Date Type' (IIcurs)

Reason' peactep Report No.

Code

  • Code' To Prevent Recurrence NA NA NA NA NA NA NA NA NA NA I

'F: Forced rReason:

' Method:

' Exhibit G - Instructions S: Scheduled A - Equipment Failure (explain) 1 - Manual for preparation of B - Maintenance or Testing 2 - Manual Scram data entry sheets C - Refueling 3 - Automatic Scram LER file (NUREG-0161)

D - Regulatory Restriction 4 - Continuation of E - Operator Training &

Previous Shutdows Licensing Exam 5 - Reduced Lead F - Administrative 6 - Other (explain)

' Exhibit I - Same Source G - Operational Error (explain)

H - Other (explain)

PBF M 8b (03-90)

-q

>i T

POINT BEACH NUCLEAR PLANT DOCKET NO.

50-301 AVERAGE DAILY UNIT POWER LEVEL UNIT NAME

- Point Beach, Unit 2 MONTH APR!L -

1995 DATE May 8,1995 COMPLETED BY M. B. Koudelka l

l TELEPHONE (414)755-6480 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1

486 11 484 21 486 2

466 12 488 22 486 3

487 13 483 23 488 4

485 14-486 24 487 5

486 15 484 25 486 6

487 16 486 26 486 4

7 486

.17 485 27 487 8

487 18 486 28 486 9

486 19 486 29 486 10 487 20 486 30 487-4

~-

- ~-

a a

w w

=

DOCKET NO.

50-301 UNIT NAME Point Beach Unit 2 DATE May 8, 1995 COMPLETED BY M.

B. Koudelka TELEPHONE 414/755-6480 Unit 2 operated at an average of 485 MWe net for the report period.

Licensee Event Report 50-301/95-003-00, Reactor Trip Due to Turbine Generator Electrohydraulic Control (EHC) System Oil Leak, was submitted.

Safety-related maintenance included:

1.

2B52-29B power to PP-18 pressurizer backup heater Group D power panel amptector unit installed.

2.

2MS-249 HX-1A steam generator SAX-2023 inlet sample isolation valve packing adjusted.

3.

2P2A charging pump O-rings replaced.

4.

2SI-896A&B valves cleaned of boric acid buildup.

5.

Harmonic filters installed and 273/A05; 274/A05; and 275/A05 Bus A05 loss of voltage relays calibrated.

i

-