4 0YSTER CREEK NUCLEAR GENERATING STATION Provisional Operating License No. DPR-16 e

Technical Specification Change Request No. 119 Docket No. 50-219 Applicant submits by this Technical Specification Change Request No. 119 to the Oyster Creek Nuclear Generating Station Technical Specifications, changes to Specification 3.1 and 4.2 a

i By P. B. Fiedler Vice President and Director Oyster Creek Sworn and subscribed to before me this

42. /

day of D M, 1983.

wfdslW lunf Notary Public gra MICHAEL LAGGART NOTARY PUBLIC OF NEW JERSEY Up Ccmme boires December 31,1985 8401060155 831221 PDR ADOCK 05000219 P

PDR

7 e

Uf;ITED STATES OF AttERICA liUCLEAR REGULATORY C0f!!!ISSIO!4 IN THE liATTER OF

)

)

DOCKET fl0. 50-219 GPU tlUCLEAR CORPORATI0!i

)

~

CERTIFICATE OF SERVICE This is to certify that a copy of Technical Specification Change Request tio.119 filed with the United States liuclear Regulatory Commission on December 21, 1983, has this 21st day of December 1983 been served on the 11ayor of Lacey Township, Ocean County, tiew Jersey by deposit in the United States raail, addressed as follows:

11ayor of Lacey Township 818 West Lacey Road Forked River, flew Jersey 08731 e

By

' P. 5. Fiedler Vice President and Director Oyster Creek

- - - - - - ----------- - -------- J

Y 3

GPU Nuclear Corporation gsplE Bs 100 lnterpace Parkway

'y Mw E

Parsippany. New Jersey 07054 201 263-6500 TELEX 136-482 Writer's Direct Dial Number:

December 21, 1983 liayor of Lacey Township 818 !!est Lacey Road Forked River,fi.J. 08731

Dear Itayor:

Enclosed herewith is one copy of Technical Specification Change Request tio.119 for the Oyster Creek tiuclear Generating Station Operating License.

This docunent was filed with the United States tiuclear Regulatory Comission on December 21, 1983.

Very truly yours, 8

.a l

!b

^

Vice President and Director Oyster Creek 1r Enclosure GPU Nuclear Corporat cn is a sutscary of the Genera l Pubhc Utihties Corporation

l OYSTER CREEK NUCLEAR GENERATING STATIO!!

(DOCKET NO. 50-219)

PROVISIONAL OPEPATING LICENSE NO. DPR-16 Applicant hereby requests the Comission to change Appendix A to the above captioned license as follows:

1.

Section to be changed:

3.1 and 4.2 2.

Extent of change:

Scram Dump Volume (SDV) modifications were performed at the Oyster Creek Nuclear Generating Station in accordance with the BVR Ouners Group recomendations in response to IE Dulletin 80-17 and its supplements.

As a result of providing two SDV instrument volumes to monitor water accunulation, the high water level scram and rod block set points have been changed. Section 3.1 has been modified to reflect these changes.

In addition, the scram discharge volume drain and vent valves closure times in Section 4.2 has been changed to be in agreement with the BWR Owners Group reconnendations.

3.

Changes requested:

Per the attached Technical Specification pages 3.1-4, 3.1-7, 3.1-7a, 3.1-11, 3.1-11a and 4.2-2.

4.

Discussion:

The NRC presented their criteria for the modification of the scram discharge system in their letter of December 1, 1980. Our letters to the NRC dated December 17, 1980, March 4, 1981 and April 30, 1981 confirm that the SDV modification at the Oyster Creek Nuclear Generating Station will be in compliance with the NRC criteria.

The modification will ensure that there is sufficient volume available in the SDV to allow all 137 control rods to scram in the event that plant conditions warrant this action. The subject modification will enhance the safety of the plant, thereby providing a greater degree of protection for the health and safety of the public.