[/$4[Ph 6[ *"~k Department of Energy Idaho Operations Office gg[
West Valley Project Office P O. Box 191 West Valley, NY 14171 October 1. 1991 Gary c. Comfort U.S. 11uclear Regulatory Commission Headquarters Washington, DC 20555
SUBJECT:
Update information for the West Valley Cement Waste Form Qualification Notebook
Dear Sir:
In accordance with our meeting with you, Mary Adams, and others on August 29, 1991, enclosed are five copies of an " official" update of information to be entered into your West Valley Waste Qualification " Notebook."
For your convenience we have also enclosed preprepared " tabs."
As indicated in the WVilS transmittal to DOE, seven of the documents are currently under " engineer release."
These are the Test Requests, Procedures and Reports, the other two items (not under " release") are the Test Plan and ACM-4801.
Mary Adams requested the ACM for information since it is referenced in some of the test procedures.
Finally an extra copy of the one~page
" flow chart" summarizing the testing activities is enclosed for convenience as well.
If you have questions please call me on FTS 472-4314.
Sincerely,
\\c, S.MR W.
S.
Ketola Technology Manager Weat Valley Project Office Enclosures
& Cel WSK:048:91 - 1614:91:10 Q l.b WSK/mla g4 911C 4d219 911001 69 PDR PROJ l
M-32 PDre
6 WD:91:1034 MS-56 Mr. T. J. Rowlard, Director September 25, 1991 West Valley Project Office, MS-DOE U.S. Department of EncIgy P.O. Box 191 West Valley IN 14171-0191
Dear Mr. Rowland:
Attnntico:
W. S. Fctola SUaT.Ecr: T:ansmittal of Documentatico to IGC, Sitdge Wash Cement Waste Form The follcuirg packet contains rtine hwents, of which seven are engineer released (ER) on Sltdje Wash Cement Qualification. The ergineerity release.1 drnents are three test procedures (WE-TP-028A, WG 'rP-028B ard WV!E-TP-034), two test stmrrary rep.ats (WV!E 'ISR-029 and WVIE-TSR-025), one test request (WVIE-TTQ<>34) ard one test plan (WV!E-TPIr70-11). Test proceduru WV!E-TP-028A ard test plan WV!G-TPIr70-11 have had engineerirg change notices (EQis) mde to the origimi ergineer released documents. These ergirneriry changed documnts shall supersede any prwicus documentation having the sam engineerirg rulcase (ER) nurber.
Also contained is the Analytical and Oxmtistry Method (72) for "Camnt Test Cuba Preparation" ard the f1cuchart for Waste Form Qualification Program for Sitdge Wash Liquid. This flowchart is a diagram which links the Waste Form Qualification Program For Cement Solidification of Sltrige Wash Liquid 1bst Plan WS-TPIr70-11 to the various test requests, test procedures ard fimi test summary reports. The Analytical ard memistry Method was requested by the IGC in conjuncticn with test proccdure WV!E-TP-025.
The test request WVIE-Tf0-028 is being perfon:od in two stages, test procedures WV!E-TP-028A ard WE-TP-028B. This is the reason why WV!E 'ITQ-028 has no "A" or "B" designation.
This cca:pletes the requests mde by the imC on August 29, 1991 in Washirgton, DC to West Valley thrlear Services.
Very truly
' [ (_ $ b. M L. E. Mi entist Analytical ard Process Gemistry West Valley Nuclear Services Co., Inc.
/ h f.
'w~
R. A. Palmr, lunager Amlytical aid Process Chemistry West Valley Ib.2 clear Services Co., Inc.
LD4/djs Attachnents DJS0630
Attad1ments:
mig-TPIr70-ll, "For the Wasta Fom Qualification PruJram For Ccunt Solidification of Sitdge Wadi Liquid",
Pc/.1 per ER #2044 arti DOI #4524 mig-TP-028A, "Pruxdure for Develc$ rent of Proocss Control Paramters for Ctmnt Solidificaticn of Sitdge Warh Liquids",
Rev.1 per ER #2076 ard IX2{ #4429 M1G-TP-028B, 'Nater to Cement Varianco in Simulatal Sitdge Warh",
Rev. O per IR #2191 mig-TSR-029, "Cenent Product frcan Actual Sitdge Wash Liquid",
Rev. O por ER #2149 mig-TSR-025, 'Maste Fom Qualification for Ctent Solidification of Sltdge Wash Liquids", Pav. O per ER #2157 M1G-TP-034, "Ocnfirmtol'f Cubo", Pav. O per ER #2163 mig 'ITQ-034, " Production of Cment Product Frun Actual laboratory Sitdge Warh Liquid", Bev. O per ER #2137 AC4-QJBE-4801 "Ctm.nt 7bst Cube Papration Method", Rev. S Wasta Fom Qualification PruJram for Sitdge Wash Liquid "ficuchart" l
l DJS0630 1