Amend 41 to License NPF-51,changing Tech Spec 4.8.1.1.2.d.1, by Granting one-time Extension to Current Surveillance Requirement by Allowing Insp of Diesel Generators to Be Deferred Until Next Refueling Outage on 911017
ML20083E527
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 09/19/1991
From: Dyer J
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20083E530 List:
References
NUDOCS 9110030017
Download: ML20083E527 (5)


Text

_

~.

-__._._-m___

y' J'F[$

UNITED STATES 3

NUCLEAR REGULATORY COMMISSION

  • k

~

WA$HINoToN. D.C. Nt66 r

%*...+/

t ARIZONA PUBLIC SERVICE COMPANY ET AL.

f DOCKET NO. STN 50-529 PALO VERDE NUCLEAR GENERATING STATION. UNIT NO. 2 tMENDMENT TO FACILITY OPERATING LICENSE i

Amendment No.

41 License No. NPF-51 1.

The Nuclear Regulatory Commission (the Connission) has found that:

A.

The application for amendment by Arizona Public Service Company (APS) on behalf of itself and the Salt River Project Agricultural Improvement and Power District, El Paso Electric Company, Southern California Edison Company, Public Service Company of New Mexico. Los Angeles Department of Water and Power arid Southern California Public Power Authority-(licensees), dated July 13, 1991, conplies with the standards and requirements of-the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations set forth in 10 CFR Part I; B.

The facility will operate in conformity with the application the provisions of Act -and the rules and regulations of, the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Consnission's regulations; D.

The issuance cf this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been-satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications'as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. NPF-74 is hereby amended to read as follows:

1 9110030017 910919 PDR ADOCK 05000530 P'

PDR

4 l.

(2) Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 41, and the Environmental Protection Plan contained in Apperdix B, are hereby incorporated into this license.

APS shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan, except where otherwise stated in specific license conditions.

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION i

b Janes E. Dyer, Director Project Directorate Y Division of Reactor Projects 111/IV/V Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:. September 19. 1991-1 P

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 41 FACILITY OPERATING LICENSE NO. NPF-51 D_0CKET NO. STN 50-529 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the areas of change.

REMOVE INSERT 3/4 8-4 3/4 8-4 3/4 8-4a f

ll 8

..--~

ELECTRICAL POWER SYSTEM SURVEILLANCE REQUIREMENTS (Continted) 4.8.1.1.2 (Continued) b.

At least once per 92 hys by verifying that a sample of diesel fuel from the fuel storage tank obtained in accordance with ASTH-D4176-82, is within the acceptable limits specified in Table 1 of ASTM 0975 81 when cnecked for viscosity, water and sediment.

c.

At least once per 184 days the diesel generator shall be started **

and accelerated to generator voltage and frequency at 4160 1 420 volts and 60 1 1.2 Hz in less than or equal to 10 seconds.

The generator voltage and frequency shall be 4160 1 420 volts and 60 1 1.2 H1 within 10 seconds after the start signal.

The generator shall be manually synchronized to its appropriate emergency bus, loaded to an indicated 5200-5400*** kW in less than or equal to 60 seconds, and operate for at least 60 minutes.

This test, if it is performed so it coincides with the testing required by Surveillance Requirement 4.8.1.1.2.& 4, may also serve to concurrently meet those requirements as well, d.

At least once per 18 months curing shutdown by:

1.

Subjecting the diesel to an inspection in accordance with procedures prepared in conjunction with its manuf acturer's

.ecoumendations for this class of standby service.*

l

% cept That the Surveillance Requirement inspection due no lat:

than September 29, 1991, may be deferred until the next refuelirg outge b x no later than December 31, 1991.

    • This test sna11 be conducted in accordance with the manufacturer's recommen-dations regarding engine prelube and warmup procedures, and as applicable regarding loading recomrnndations.
      • This band is meant as guidance to avoid routine overloading of the engine.

Loads in excess of this band for special testing under direct monitoring (i the manufacturer or momentary variations due to changing bus loads shall r,it invalidate the test.

PALO VERDE - UNIT 2 3/4 8-4 Ameridment No. 41

ELECTRICAL POWER SYSTEM SURVEILLANCE REQUIREMENTS (Continued) 2.

Verifying the generator capability to reject a single largest load of greater than or equal to 839 kW (Train B A W pump) for emergency diesel generator B or 696 kW for emergency diesel generator A (Train A HPSI pump) while maintainin voltage at voltsandfrequencyat6011.2Hz.**g*

4160 1 420 3.

Verifying that the automatic load sequencers are OPERABLE with the interval between each load block within i I second of its design interval.****

4.

Simulating a loss of offsite power by itself, and:

a)

Verifyingdeenergizationoftheemerggcybussesandload shedding from the emergency busses.*

b)

Verifying the diesel starts ** on the auto-start signal, energizes the emergency busses with aermanently connected loads within 10 seconds, energizes tie auto-connected shut-down loadri through the load sequencer and operates for greater than or equal to 5 minutes while its generator is

" " Deferred until cycle 3 refueling outage.

PALO VERDE - UNIT 2 3/4 8-4a Amendment No. 41 (new page) l T