'95 MAY -3 P3 :27 Tr.Pg.2 Date: 3-30-90 0FFICE OF SECRETARY DOCKElmG d SERVICE Bockhold: We're going to come up with the trOSMble senario. Okay, what caused the problem out there.

Mosbaugh: Hopefully, we can come up with just the actual real right root cause.

Bockhold: If we can come up with the actual real root cause, that would wonderful. I don't think that's going to happen, my gut reaction.

Mosbaugh: Well, George, you know the NRC is going to write a NUREG on this, Bockhold: I understand.

Mosbaugh: When you write a NUREG--

Bockhold :

If you don't have a probable cause-Mosbaugh:

vou kind of need -you kind of need an actual real root cause.

Bockhold: I understand exactly, but I don't think it's going to happen. I think we're going to blame it on -from what I heard the expert say in that meeting in there is that we re going to blame it on air leakage and one of the lube oil sensors being vented continuously-SEGMENT #2 Tr.Pg.4 Date : 3-30-90

(

Bockhold: See the flavor is - NRC is chasing every loose dangling end out there right now.

Mosbaugh: Yeah.

Bockhold:

And I'm concemed that come tomorow, okay, thery're going to be more frustrated when we've done all the testing and the engine's running great, you know.

Mosbaugh: It certainly is frustrating when we can't find the root cause.

Bockhold: That's right.

NUCLEAR REGULATORY COMMISSION So. 9 2 4 w - )

^+ lI DxH t flo To w 2 i-cu - 2 Oft:cial Exh. No.

in the rner ot tle n t le b"5

2

Swf, IdNTiRED Apwa,t RECEIVED inuroor V

REXCIED 9505230274 950419 Co-rg et r PDR ADOCK 05000424 Catraucr DG 0,

0 PDR Ow Weess _ 6 a c K Le Id Reco: tar 1 2 D5ki

-