ML20083A317

From kanterella
Jump to navigation Jump to search
Significant Deficiency Rept 90 Re Uncorrelated Data for Comsip,Inc Containment Gas Analyzer Catalyst Bed Configuration.Defective Equipment Assumed Corrected Per Vendor Instructions.Also Reported Per Part 21
ML20083A317
Person / Time
Site: Limerick  
Issue date: 12/07/1983
From: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML17150A234 List:
References
REF-PT21-83 10CFR-050.55E, 10CFR-50.55E, 90, NUDOCS 8312200251
Download: ML20083A317 (2)


Text

.

PHILADELPHIA ELECTRIC COMPANY 23O1 MARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 JOHN S. KEMPER VIC E PR ESID E NT assessoas messo aseo mass ances December 7, 1983 Mr. Thomas E. Murley, Director United States Nuclear Regulatory Commission Of fice of Inspection and Enforcement, Region I 631 Park Avenue King of Prussia, PA 19406 Subjec t:

Significant Deficiency Report No. 90 Comsip, Inc. Containment Gas Analyzers Limerick Generating Station, Units 1 and 2

Attachment:

Letters Comsip, Inc. to USNRC dated April 13, 1983 File: QUAL 2-10-2 (SDR /190)

Dear Mr. Murley:

The attached letter has brought to our attention a deficiency in the Comsip, Inc. Containment Gas Analyzers concerning catalyst bed configuration on this equipment. This deficiency has been previously reported to the USNRC under the provisions of 10CFR, Part 21.

We consider the deficiency described in the Attachment as a significant deficiency per 10CFR50.55(e) and are hereby notifying you as required.

We believe that the Comsip, Inc, report submitted under the provisions of.*10CFR, Part 21 provides the inf ornntion required for 10CFR50.55(e) reporting. Therefore, we anticipate that this letter will be our only report to you on this subject.

We will of course assure that the defective equipment is corrected in accordance with the instructions received from the vendor.

Sincerely, JPE/drd /831202-1 EM[

Attachment Copy to: Director of Inspection and Enforcement United States Nuclear Regulatory Commission Washington, DC 20555 S. K. Chaudhary, USNRC Resident Inspector hp

%q O

6 hJ