ML20082V091
ML20082V091 | |
Person / Time | |
---|---|
Site: | Catawba ![]() |
Issue date: | 09/16/1991 |
From: | Tuckman M DUKE POWER CO. |
To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
References | |
NUDOCS 9109230110 | |
Download: ML20082V091 (2) | |
Text
Il I
Us
.,e4s f
I'
- i / t r e-
\\
>i-
. / s.
6,/.
e
+
i i n !:., i s
is
,/
- 4. '
\\I ouxtPowen September 16,1991 U. S. Nuclear Regulatory Commission A1TN: Document Control Desk Washington, DC 20555
Subject:
Catawba Nuclear Station, Unit i Docket No. 50-413 Special Report Vibration and loose Parts Monitoring System Pursuant to Technical Specification 3.3.3.9, find attached a Special Report concerning the inoperability of the Unit i Vibration and loose Parts Monitoring System Channel 11 (Steam Generator C).
Very truly yours, S'
hk M. S. Tuckman CRUSR916 Attachment xc: S. D. Ebneter Regional Administrator, Region 11 R. E. Martin, ONRR W. T. Orders Senior Resident inspector 1
6' I
91o9230110 910916 f l' l
DR ADOCK 0000 4 t,3 T
I SPECIAL REPORT CATAWilA NUCIIAR STATION, UNIT 1 Vibration and Loose Parts Monitoring System Channel 11 On August 9,1991, Channel 11 (Steam Generator C) of the Vibration and Ixose Parts Monitoring System was declared inoperable due to high background noise on the c The channel will not be repaired until a future outage because a containment en required. Channel 7, which is the other Steam Generator C Channel, is operable and provides coverage.
Since the channel has been inoperable for more than 30 days, it is reportable to the N pursuant to Technical Specification 3.3.3.9.
i e
4 l
l l
. ~...
-