l 1

Commonwealth Edison Company i

fly ron Generating Station V

4 i' O Nonh German Omrch Road 1 ion, il 6lOlW)794 I t t 815-234 5 611 April 18, 1995 LTR:

BYRON 95-0136 FILE:

2.12.1718 l

TO:

Document Control U.S. Nuclear Regulatory Commissic,n Mail Station P1-137 Washington, D.C.

20555

? Operating Report

SUBJECT:

1994 Byron Station Radiological Environmentt Enclosed is the 1994 Byron Station Annual Radiological Environmental Operating Report, Docket Numbers 50-454 and 50-455.

This report contains the results of the Radiological Environmental and Meteorologic al Monitoring Programs.

The Radioactive Effluent Release Reports were submitted under separate cover in August of 1994 and February of 1995.

Two copies of the report are provided for your use. Two copies will be forwarded to Region III, and one copy to the Senior Resident Inspector.

r...

I G.L Schwartz Sta' ion Manag t

Byron Nuclear Power station GKS/DD/keh Attachment

" E C I l'. J e 9504280001 941231 PDR ADOCK 05000454

[l

.R PDR (p:\\byltro\\950136\\041895)

./

A l'nk om Company u.,,

I I

I BYRON STATION ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 1994 I

I APRIL 1995 l

TABLE OF CONTENTS Eage INTRODUCTION.....

1

SUMMARY

2 1.0 EFFLUENTS 1.1 Gaseous Effluents to the Atmosphere.......

3 1.2 Liquids Released to Rock River.....

3 2.0 SOLID RADIOACTIVE WASTE.................

3 3.0 DOSE TO MAN 3.1 Gaseous Effluent Pathways........

3 3.1.1 Noble Gases.....

3 3.1.1.1 Gamma Dose Rates..

3 3.1.1.2 Beta Air and Skin Dose Rates....

3 3.1.2 Radioactive Iodine...

4 I

3.1.2.1 Iodine Concentrations in Air...

4 3.1.2.2 Dose to Infant's Thyroid.......

4 3.1.3 Concentrations of Particulates in Air...

4 3.2 Liquid Effluent Pathways.................................

4 I

3.3 Assessment of Dose to Member of Public..

5 4.0 SITE M ETEOROLOGY...........................................

5 5.0 ENVIRONMENTAL MONITORING 5.1 Gamma Radiation..........

6 5.2 Airborne I-131 and Particulate Radioactivity..........

6 5.3 Terrestrial Radioactivity..

6 5.4 Aquatic Radioactivity...

6 5.5 Milk......

7 5.6 Sample Collections....

7 5.7 Program Modifications.........

7 6.0 ANALYTICAL PROCEDURES...

8 7.0 MILCH ANIMALS AND NEARESTCA'ITLE CENSUS........

8 8.0 NEAREST RESIDENSES CENSUS...........

8 9.0 INTERLABORATORY COMPARISON PROGRAM RESULTS.....

8 e

TABLE OF CONTENTS (continued)

Page APPENDIX I - DATA TABLES AND FIGURES.......

9 Station Releases Table 1.1-1 Gaseous Effluents...

10 I

Table 1.2-1 Liquid Effluents......

18 Table 2.0-1 Solid Radioactive Waste..

22 Figure 3.1 Figure 3.1-4 Isodose and Concentration Contours....

26 Table 3.1-1 Maximum Doses Resulting from Airborne Releases.........

30 Table 3.2-1 Maximum Doses Resulting from Liquid Discharges....

34 Table 3.3-1 10CFR20 Compliance Assessment.................

36 Environmental Monitoring Figure 5.0-1 Inner and Outer Ring TLD Locations.....

38 Figure 5.0-2 Fixed Air Sampler Locatic:s..

39 Figure 5.0-3 Water Sample Locations....

40 Figure 5.0-4 Milk Sample Locations..

41 Table 5.0-1 Radiological Environmental Monitoring Locations....

42 Table 5.0-2 Radiological Environmental Monitoring Program, Sam aling Locations and Sample Collection and Ana yses...

43 Table 5.0 Table 5.0-6 I

Radiological Erwironmental Monitoring Program Quarterly Summary.....

49 APPENDIX II - METEOROLOGICAL DATA.

56 APPENDIX III - 1994 REMP SAMPLE RESULTS...

85 APPENDIX IV - INTERLABORATORY COMPARISON PROGRAM RESULTS...... 172 I

is

l l

1 l

I INTRODUCTION Byron Station, a two-unit PWR plant, is located about two miles east of the Rock River and approximately three miles southwest of Byron in Ogle County, north central Illinois. Each reactor is designed to have a capacity of 1120 MW net. Unit No.1 loaded fuel in November 1984 and went on line February 2,1985. Unit No. 2 went on line January 9,1987. The plant has been designed to keep releases to the environment at levels below those specified in the regulations.

l Liquid effluents from Byron Station are released to the Rock River in controlled batches after radioassay of each batch. Gaseous effluents are released to the atmosphere and are calculated on the basis of analyses of daily grab samples of noble gases and continuously collected composite sa.nples of iodine and particulate matter. The results of effluent analyses are 7

I summarized on a monthly basis. Airborne concentrations of noble gases,1-131, and particulate i

radioactivity in offsite areas are calculated using isotopic composition of effluents and meteorological data.

I j

Environmental monitoring is conducted by sampling at indicator and control (background)

'i locations in the vicinity of Byron Station to measure changes in radiation or radioactivity levels that may be attributable to plant operation. If significant changes attributable to Byron Station are measured, these changes are correlated with effluent releases. External gamma radiation exposure from noble gases and I-131 in milk are the critical pathways at this site; however, an i

environmental monitoring program is conducted which also includes other pathways.

j 1

1 I

i

.I 1

l l

l

I

SUMMARY

Gaseous and liquid effluents for the period contributed to only a small fraction of the Technical Specification limits. Calculations of environmental concentrations based on effluent, Rock River flow, and meteorological data for the period indicate that consumption by the public of radionuclides attributable to plant operations are well below regulatory limits. Radiation exposure from radionuclides released to the atmosphere represented the critical pathway for the period with a maximum adult dose estimated to be 2.87E-05 mrem f or the year, where a shielding and occupancy factor of 0.7 is assumed. The assessment of radiation doses is performed in accordance with the Offsite Dose Calculation Manual (ODCM). The resul*s of I

analysis confirm that the station is operating in compliance with 10CFR50 Appendix 1 and 40CFR190.

I There were no additional operational controls implemented which affected the areas of radiological effluents in 1994.

There were no measurements which exceeded the reporting levels, including any which would I

not have been attributable to plant effluents.

The results of the current radiological environmental monitoring program are approximately Ae same as those found during the preoperational studies conducted at Byron Station.

I I

I I

I

~

1.0 EFFLUENTS 1.1 Gaseous Effluents to the Atmosphere Measured concentrations and isotopic composition of noble gases, radiciodine, and particulate radioactivity released to the atmosphere during the year are listed in Table 1.1-1. A total of 3.61E+01 curies of fission and activation gases was released with a maximum quarterly release rate of 3.70E+01 pCi/sec, for both units.

There was no I-131 or I-133 detected in gaseous effluents during the year.

A total of 4.69E-05 curies of beta emitters was released as airborne particulate matter with no alpha emitters being detected.

A total of 2.60 curies of tritium was released.

1.2 Liquids Released to Rock River I

A total of 2.52E+07 liters of radioactive liquid waste (prior to dilution) containing 6.40 curies (excluding tritium, gases and alpha) were discharged from the station. These wastes were released at a maximum quarterly average concentration of 7.95E-07 pCi/ml. A total of 1.82E+03 curies of tritium was released. Quarterly release totals of principal radionuclides in liquid effluents are given in Table 1.2-1.

2.0 SOLID RADIOACTIVE WASTE Solid radioactive wastes were shipped to Barnwell, South Carolina. The record of waste shipments is summarized in Table 2.0-1.

3.0 DOSE TO MAN 3.1 Gaseous Effluent Pathways Table 3.1-1 summarizes the doses resulting from releases of airbome radioactivity via the different exposure pathways.

3.1.1 Noble Gases 3.1.1.1 Gamma Dose Rates Offsite Gamma air and whole body dose rates are shown in Table 3.1-1 and were calculated based on measured release rates, isotopic I

composition of the noble gases, and average meteorological data for the period. Isodose contours based on concurrent meteorological data for gamma dose are shown in Figure 3.1-1 for the year. Based on measured I

effluents and average meteorological data, the maximum dose to an individual would be 2.87E-05 mrem for the year, with an occupancy or shielding factor of 0.7 included, and based on measured effluents and concurrent meteorological data would be 1.18E-03 mrem. The maximum gamma air dose was 4.01E-05 mrad, and 2.11E-03 mrad based on concurrent meteorological data.

3

n LJ O

3.1.1.2 Beta Air and Skin Dose Rates The range of beta particles in air is relatively small (on the order of a g

few meters or less); consequently, plumes olgaseous effluents may be g

considered " infinite" for the purpose of calculating the dose from beta radiation incident on the skin. However, the actual dose to sensitive skin tissues is difficult to calculate because this depends on the beta particle energies, thickness of inert skin, and clothing covering sensitive tissues. For purposes of this report the skin is taken to have a thickness of 7.0 mg/cm2 and an occupancy factor of 1.0 is used. This skin dose from beta and gamma radiation for the year was 7.72E-05 mrem.

The air concentrations of radioactive noble gases at the offsite receptor locations are given in Figure 3.1-2. The maximum offsite beta air dose for the year was 1.34E-04 mrad.

3.1.2 Radioactive Iodine The human thyroid exhibits a significant capacity to concentrate ingested or inhaled iodine. The minimal levels of radioiodine, I-131, released during E

routine operation of the plant may be made available to man resulting in a dose E

to the thyroid. The principal pathway of interest for this radionuclide is ingestion of radiciodine in milk ay an infant. Calculations made for 1993 and g

previous years indicate that contributions to doses from inhalation of I-131 and g

I-133 and I-131 in milk are negligible.

3.1.2.1 Iodine Concentrations in Air The calculated concentration contours for iodine in air are shown in Figure 3.1-3. Included in these calculations is an iodine cloud depletion E

factor which accounts for the phenomenon of elemental iodine g

deposition on the ground. There were no detectable iodine releases during the year.

3.1.2.2 Dose to Infant's Thyroid The hypothetical thyroid dose to an infant living near the plant via E

ingestion of milk was calculated. The radionuclide considered was I-5 131 and the source of milk was taken to be the nearest dairy farm with the cows pastured from May through October. The maximum infant's thyroid dose was 0.00 mrem during the year (Table 3.1-1).

3.1.3 Concentrations of Particulatesin Air Concentration contours of radioactive airborne particulates are shown in Figure 3.1-4. The maximum annual offsite concentration is estimated to be 2.91E-06 pCi/m3, 3.2 Liquid Effluent Pathways The three principal pathways through the aquatic environment for potential doses to man from liquid waste are ingestion of potable water, eating aquatic foods, and exposure while walking on the shoreline. Not all of these pathways are significant or I

4 g

l l

applicable at a given time or station but a reasonable approximation of the dose can be made by adjusting the dose formula for season of the year or type and degree of l

use of the aquatic environment. NRC developed equations' were used to calculate the doses to the whole body, lower GI tracts, t iyroid, bone, skin; specific parameters for use in the equations are given in the Commonwealth Edison Offsite Dose Calculation Manual. The maximum whole body dose for the year was 6.40E-03 mrem and no organ dose exceeded 4.06E-02 mrem (Table 3.2-1).

3.3 Assess.nent of Dose to Member of Public 4

During the period January to December,1994, Byron Station did not exceed these limits as shown in Table 3.1-1 and Table 3.2-1 (based on yearly average meteorological data), and as shown in Figure 3.1-1 (based on concurrent meteorological data), and as shown in Table 3.3-1:

The RETS limits on dose or dose commitment to a member of the public due to radioactive materials in liquid effluents from each reactor unit (3 mrem to the whole body or 10 mrem to any organ during any calendar quarter; 6 mrem to the whole body or 20 mrem to any organ during any I

calendar year).

The RETS limits on air dose in noble gases released in gaseous effluents to a member of the public from each reactor unit (5 mrad for gamma radiation or 10 mrad for beta radiation during any calendar quarter; 10 I

mrad for gamma radiation or 20 mrad for beta radiation during any calendar year).

The RETS limits on dose to a member of the public due to iodine-131, iodine-133, tritium, and radionuclides in particulate form with half-lives l

greater than 8 days in gaseous effluents released from each reactor unit (7.5 mrem to any organ during any calendar quarter: 15 mrem to any organ during any calendar year).

I The 10CFR20 limit on Total Effective Dose Equivalent to individual members of the public (100 mrem).

1 4.0 SITE METEOROLOGY A summary of the site meteorological measurements taken during each calendar quarter of the year is given in Appendix II. The data are presented as cumulative joint frequency distributions of the wind direction for the 250' level and wind speed class by atmospheric stability class determined from the temperature difference between the 250' and 30' evels.

Data recovery for all measurements on the tower was 99.9%.

5.0 ENVIRONMENTAL MONITORING Table 5.0-1 provides an outline of the Radiological Environmental Monitoring Program (REMP) as required in the Technical Standards. Table 5.0-2 outlines the sampling locations, sample collection frequency and analysis for the samples. Sampling locations are shown in Figures 5.0-1 through 5.0-4. Concentrations of radioactivity in various media are summarized in Tables 5.0-3 through 5.0-6. A detailed listing of all data is presented an Appendix III.

5

E

=

I Specific findings for various environmental media are discussed below.

5.1 Gamma Radiation External radiation dose was measured using CaSO4:Tm thermoluminescent dosimeters (TLDs). Each location consists of 2 TLD sets. The annual average external radiation dose was 16.3 mR at the indicator locations and 14.3 mR at the control locr.tions. TLD results are listed in Section 4.0 of Appendix 111 and Jocations are shown in Figure 5.0-1.

Quarterly external radiation dose at twelve air sampling locations averaged (14.9) mR and was similar to that measured in 1985 (14.4 mR),1986 (14.9 mR),1987 (15.3 mR),

1988 (15.2 mR),1989 (14.6 mR),1990 (14.5 mR),1991 (14.3 mR),1992 (13.6 mR), and 1993 (14.2 mR). These differences are not statistically significant.

5.2 Airborne I-131 and Particulate Radioactivity Locations of the samplers are shown in Figure 5.0-2. Airborne I-131 remained below 3

the LLD of 0.07 pCi/m throughout the year in all samples.

Gross beta concentrations ranged from 0.006 to 0.051 pCi/m3 and averaged 0.021 pCi/m3, which is slightly lower than the average concentrations in 1985 (0.026 3

pCi/m ),1986 (0.026 pCi/m3, except for the period from May 12 through June 9 when it was influenced by the nuclear reactor accident at Chernobyl), 1987 (0.027 3

pCi/m ),1988 (0.031 pCi/m3),1989 (0.026 pCi/m3), and about the same as in 1990 3

(0.021 pCi/m3),1991 (0.020 pCi/m ),1992 (0.022 pCi/m3), and 1993 (0.021 pCi/m3),

All gamma-emitting nuclide activities were below their respective LLD levels. No radioactivity attributable to plant operation was detected in any samples.

5.3 Terrestrial Radioactivity Vegetables were collected in July, August, and September and analyzed for gamma-emitting nuclides. In addition, green leafy vegetables were analyzed for Iodine-131.

All nuclides were below the limits of detection, indicating that there was no 3

measurable amount of radioactivity attributable to the station releases. Identical E

results were obtained during the period 1985 through 1993.

5.4 Acuatic Radioactivity 1

Well water was collected monthly from two offsite wells, shown in Figure 5.0-3, and analyzed for gross beta, tritium, and gamma-emitting nuclides. All other results were E

below the lower limits of detection. The results were similar to those obtained in 1985 5

through 1993.

Surface water samples were collected weekly from four locations shown in Figure 5.0-

3. Weekly samples were composited monthly and analyzed for gamma emitters.

Quarterly composites were analyzed for tritium. Cs-134 and Cs-137 concentrations were below the LLD level of 15 pCi/L and 18 pCi/L, respectively, in all samples.

l Tritium concentration was below the LLD of 200 pCi/L in all samples collected from t

6 m:=

the Woodland Creek (BY-09), Upstream (BY-13), and Upstream (BY-29). These icvels were similar to those obtained in 1985 through 19?3.

I Downstream from discharge (BY-12), tritium averaged 838 pCi/L, ranging from 473 to 1,391 pCi/L. Cs-134 and Cs-137 levels were below the LLD level of 15 pCi/L and 18 pCi/L, respectively, in all samples. All other gamma-emitters were below their respective LLDs. Elevated levels of tritium downstream from discharge pipe are I

attributable to the station operation. These levels were similar to those obtained in 1985 through 1993.

I Sediment samples were collected twice, from two control and one indicator locations, and analyzed for gamma-emitters. Cs-134 was below the LLD level of 0.15 pCi/g dry weight in all samples. Cs-137 was detected in two samples (one control and one I

indicator) and averaged 18.4 pCi/g dry weight, similar to that observed in 1991 (0.27 pCi/g dry weight),1992 (0.16 pCi/g dry weight), and 1993 (0.25 pCi/g dry weight).

l All other gamma-emitting nuclides, except naturally occurring gamma-emitters, were below detection limits.

i Levels of gamma radioactivity in fish were measured and found in all cases to be l

below the lower limits of detection for the program. The results were identical to

{

those obtained in 1985 through 1993.

5.5 Milk Milk samples were collected monthly from November through April and semimonthly from May through October and analyzed for Iodine-131 and gamma-emitting nuclides. Locations shown in Figure 5.0-4. Iodine-131 level was below the LLD level of 1.0 pCi/L in all samples.

Cs-134 and Cs-137 were below the LLD levels of 15 pCi/L and 18 pCi/L, respectively.

!3 All other gamma-emitting nuclides, except naturally-occurring K-40, were below their

! E respective LLDs. The results for I-131, Cs-134 and Cs-137 were identical to those obtained during the period 1985 through 1993, except during several months following the accident at Chernobyl, which occurred on April 26,1986. During those I

months I-131 ranged from 0.9 to 58.6 pCi/L, Cs-134 ranged from 5.8 to 10.7 pCi/L and Cs-137 ranged from 5.3 to 17.8 pCi/L.

5.6 Sample Collections All samples were collected as se eduled except those listed in Listing of Missed Samples, Section 2.0 of Appendix III.

5.7 Program Modifications I

The ODCM and Figures 11-2,11-3, and 11-4 were revised to include the new TLD locations and update various sample locations. Table 11-1 was revised to include new TLD locations and update sector and distances of various sampling locations.

A more rigid definition for the quarter has been adopted for 1994. Each quarter is 13 weeks long. The week shall start on Monday and end on Sunday, with week #1 (1994) beginning on the first Monday of January (1/3/94). Due to this new definition

,I all sa mples collected prior to 1/3/94 were reported as 1993 samples.

The following TLD's were deleted in the third quarter:

7 I

O E

I BY-101-1,2 BY-113-1,2 BY-111-1,2 The following TLD's were added for third quarter:

BY-111-3,4 BY-210-3,4 BY-214-4 BY-112-3,4 BY-212-4 BY-215-4 BY-201-3,4 BY-213-4 6.0 ANALYTICAL PROCEDURES l

Procedures used during the period covered in this report remained essentially unchanged.

A summary of the procedures used for analyzing radioactivity in environmental samples 1

is given in Appendix VI of the report for the period January - December 1993.

I(

7.0 MILCH ANIMALS AND NEAREST CATTLE CENSUSES Censuses of milch animals and nearest cattle were conducted within a five mile radius of the Station. The survey was conducted by " door-to-door" canvas and by information from Illinois agricultural agents. The censuses were conducted by W. Mueller on August 17 and 18,1994.

Results of the milch animal and nearest cattle censuses are presented in Table 9 of Appendix 111.

8.0 NEAREST RESIDENCES CENSUS The census of nearest residences within a five mile radius was conducted by W. Mueller on August 17,1994.

Results of the nearest residence census are presented in Table 9 of Appendix III.

9.0 INTERLABORATORY COMPARISON PROGRAM RESULTS Tcledyne's Interlaboratory Comparison Program Results are presented in Appendix IV.

Commonwealth Edison's Thermoluminescent Dosimeter (TLD) Program is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) which requires biennial review and evaluation. In addition to the biennial ANSI tested requirement, g

Commonwealth Edison also tests to the ANSI standard during the non-NVLAP visitation 3

year. Commonwealth Edison additionally has an internalirradiation program that tests each of the six nuclear station TLD processors once per quarter. The results of all TLD performance tests are retained by Commonwealth Edison's Corporate Health Physics Support.

I 8

e is "

l.

l l

I lI f

II I

AreEsD1x,

1l DATA TABLES AND FIGURES l!

l I

e suuses 9

I TABLE 1.1-1 BRP 6100 671 Revision 2 I

BYRON NUCLEAR POWER STATION UNIT I

DOCKET NUMBER STN 50 454 RADIOACTIVE RFFLUENT RELEASE REPORT fanuarv 1994 THROUGH June 1994 I.

GASEOUS EPPLCEhrS - SUMMATION OP ALL PELEASES UNITS IST QTR 2ND OTR 3RD QTR 4'DI QTR A.

FISSION AND ACTIVATION GAS RELEASES 1.

Total Release Activity Ci 2.72E-1 3.51E-1 2.

Maximum Release Rate for Quarter uCi/sec 2.85E+0 1.97E+0 3.

6 of 10CFR20 Limits

  • a.

Whole Body (500 mrem /yr) 0.00 0.00 b.

Skin (3000 exem/yr) t 0.00 0.00 4.

t of 10CFR50 Limits a.

Garma Quarterly (5 mrad) 0.00 0.00 b.

Beta Quarterly (10 mrad) 0.00 0.00 c.

Gamma Annual (10 mrad) 0.00 0.00 d.

Beta Annual (20 mrad) g 0.00 0.00 5.

IODINE RELEASES" 1.

Total I 131/I 133 Activity Ci

<LLp

<LLD C.

PARTICOLATE (>8 day half-life) RELEASES" 1.

Cross Activity Ci (Ltp

<tto 2.

Gross Alpha Activity for Quarter Ci

<LLD

<LLD D.

TRITIUM RELEASES **

1.

Total Release Activity C1 1.37E-1 7.20E-1

% of 10CFR20 limits is based on the mavf =m release rate for the period considered.

" Iodine, particulate, and tritium % of 10CFR20/10CTR50 limits are expressed as a total I

limit. See step E.

I 10 t

I

[.)

O; I

I TABLE 1.1 1 (continued)

BRP 6100 671 Revision 2 BYRON NUCLEAR POWER STATION i

UNIT I DOCKET FUMBER ST1t*50 454 RADICACTIVE IFFLUENT RELEASE REPORT January 1994 THROUGH June

, _ 1994 GASEOUS EFFLUEFr$ - SUMMATION OF ALL RELEASES (CONT)

UNITS 1ST OTR 2ND QTR 3RD 7TR 4TH CTR E.

SUM OF ICDINE, PARTICULATE (>S day half-life), AND TRITIUM RELEASES 1.

Total Activity Ci 1.37E-1 7.20E-1 2.

% cf 10CFR20 Limit a.

Any Organ (1500 arem/yr) 0.00 0.00 3.

t of 10CFR50 Limit a.

Quarterly Any Organ (7.5 mram) 0.00 0.00 b.

Annual Any Organ (15.0 mrea) g 0.00 0.00 I

I 11 5.

TABLE 1.1-1 (continued)

I BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN 454 RADIOACTIVE EFFLUDIT RELEASE REPORT JULY 1994 '[HROUGH DECEMBER 1994 I

GASEOUS EFTLUENTS - StN.ATION OF ALL PILEASES I

UNITS IST QTR 2ND QTR 3RD QTR 4TH QTR A.

FISSION AND ACTIVATION GAS RELEASES 1.

Total Release Activity Ci 1.66E+1 6.01E+0 2.

Maximum Release Rate for Quarter uCi/sec 3.70E+1 1.84E+1 3.

t of Tech Spec Limits

  • a.

Whole Body (500 mrem /yr) o,co o,co b.

Skin (3000 mrem /yr) t 0.00 0.00 4.

t of 10CMt50 Limits a.

Gamma Quarterly (5 mrad) t 0.00 0.00 b.

Beta Quarterly '(10 mrad) t 0.00 0.00 c.

Gamma Annual (10 mrad) t 0.00 0.00 d.

Beta Annual (20 mrad) t 0.00 0.00 B.

IODINE RELEASES **

1.

Total I-131/I-133 Activity Ci (LLD

<LLD C.

PARTICULATE (>8 day half-life) RELEASES **

l 1.

Gross Activity Ci 9.60E-6

<LLD 2.

Gross Alpha Activity for Quarter Ci (LLD

<LLD I

D.

TRITIUM RELEASES **

1.

Total Release Activity Ci 1.81E-1 1.26E-1 t of Tech Spec limits is based on the maximum release rate for the period considered.

Iodine. particulate. and tritium are expressed as a total limit. See step E.

12 j

i Ol 0l TABLE 1.1-1 (continued)

BYRON NUCIJAR POWER STATION UNIT I DOCKET NUMBER STN-50 454 RADIOACTIVE EITLUENT RELEASE REPORT i

JULY 1994 TitROUGH DECEMBER 1994 Q3SECUS EFTLUENTS - SUMMATION OF ALL RELEASES (COh"M UNITS IST QTR 2ND QTR 3RD QTR 4'DI QTR E.

TOTAL OF IODINE. PARTICULATE (>e day half life). AND TRITIUM RELEASES 1.26E-1l 1.

Total Activity Ci g, gig.1 2.

% of Tech Spec Limit a.

Any Organ (1500 mrem /yr) t 0.00 0.00 3.

t of 10CFR50 Limit l

a.

Quarterly Any Organ (7.5 mrem) t 0,00 0,00 b.

Annual Any Organ (15.0 mrem) t 0.00 0.00 I

13

=.

TABLE 1.1-1 (continued)

I BRP 6100-671 Revision 2 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER S7W 50 455 RADIQACTIVE EFFLUENT RELIASE REPORT January 1994 m June 1994 I

CJLSEOUS EFFLUEffrS - SUMMATION OF ALL RELEASES UNITS 1ST QTR 2ND 7fR 3RD 7TR 4TH QTR A.

FISSION AND ACTIVATION GAS RELEASES 1.

Total Release Activity C1 1.59E-1 3.44E-1 I

2.

Maximum Release Rate for Quarter uCi/see 1.91E+0 1.38E+0 3.

% of 10CFR20 Limits

  • a.

Whole Body (500 mrem /yr) 0.00 0.00 b.

Skin (2000 mrem /yr) 0.00 0.00 4.

% of 10CFRSO Limits a.

Gama Quarterly (5 mrad) 0.00 0.00 b.

Beta Quarterly (10 mrad) 0.00 0.00 c.

Gama Annual (10 mrad) 0.00 0.00 d.

Beta Annual (20 mrad) 0.00 0.00 B.

IODINE RELEASES **

1.

Total I-131/I-133 Activity Ci

<LLD

<LLD l

C.

PARTICULATE (>$ day half-life) RELEASES **

1.

Gross Activity C1

<tto

<LLD 2.

Gross Alpha Activity for Quarter Ci

<LLD

<LLD D.

TRITIUM RELEASES **

1.

Total Release Activity C1 2.75E-1 4.75E-1

% of 10CFR20 limits is based on the =mv4== release rate for the period considered.

Iodine, particulate, and tritium % of 10CFR20/10CFR50 limits are expressed as a total limit. See step E.

I 14 I

E=

TABLE 1.1-1 (continued)

BRP 6100 671 Revision 2 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER SDI 50 455 E

RADICACTIVE EFFLUENT RELEASE REPORT January 1994 IHROUGH June 1994 GASECUS EPPLUE?rTS - SUMMATION OF ALL RELEASES (CO}rr)

UNITS IST 7TR 2ND QTR 3RD QTR 4'DI QTR I.

SUN OF IODINE, PARTICULATI (>$ day half-life), AND TRITIUM RELEASES 1.

Total Activity Ci 2.75E-1 4.75E-1 2.

% of 10CFR20 Limit a.

Any Organ (1500 mram/yr) l t

0.00 0.00 3.

% of 10CFR50 Limit a.

Quarterly Any organ (7.5 mrea) o,00 0,00 b.

Annual Any organ (15.0 mrea) 0.00 0.00 E

i I

g is

=

TABLE 1.1-1 (Continued)

BYRON NUCLET.R POWER STATION UNIT

?

DOCKET NUMBER STN 50 455 RADIOACTIVE EFTLUElfr RZLEASE REPORT JULY 1994 THROUGH DECEMBER 1994 l

1 GASEOUS EFFLUDTTS - St.M% TION OF ALL RELEASES UNITS IST QTR 2ND QTR 3RD QTR 4TH QTR A.

FISSION AND ACTIVATION GAS RELEASES l

1.

Total Release Activity Ci 1.20E+1 3.62E-1 2.

Maximum Release Rate for Quarter uC1/see 3.70E+0 7.83E+0 j

I l

l 3.

t of Tech Spec Limits

  • l l

a.

Whole Body (500 mrem /yr) t 0.00 0.00 b.

Skin (3000 mrem /yr) g 0.00 0.00 4.

t of 10CTR50 Limits j

a.

Gamma Quarterly (5 mrad) 1 0.00 0.00 b.

Beta Quarterly'(10 mrad) g 0.00 0.00 c.

Gamma Annual (10 mrad) 0.00 0.00 d.

Beta Annual (20 mrad) g 0.00 0.00 5

B.

IODINE RELEASES" 1.

Total I-131/I-133 Activity Ci

<LLD

<LLD C.

PARTICULATE (>8 day half-life) RELEASES" 1.

Gross Activity Ci 8.31E-6 2.90E-5 2.

Gross Alpha Act2vity for Quarter Ci (LLD

<LLD l

1 D.

TRITIUM RELEASES" j

1.

Total Release Activity Ci 4.63E-1 2.27E-1 t of Tech Spec limits is based on the ma.ximum release rate for the period considered.

Iodine, particulate, and tritium are expressed as a total limit. See step E.

I 1

l I

16

O O'

TABLE 1.1-1 (continued)

BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER 571f 455 _

RADIOACTIVE ETTLUENT RELEASE REPORT JULY 1994 THRCUGH _ DECEMBER 1994 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES (CONT)

UNITS IST QTR 2ND QTR 3RD QTR 4TH QTR E.

TOTAL OF IODINE, PARTICULATE (>B day half-life), AND TRITIUM RELEASES 1.

Total Activity C1 4.63E-1 2.27E-1 2.

t of Tech Spec Limit a.

Any Organ (1500 mrem /yr) t 0.00 0.00 3.

4 of 10CFR50 Limit a.

Quarterly Any Organ (7.5 mrem) 0.00 0.00 b.

Annual Any organ (15.0 mrem) t 0.00 0.00 1

i l

I 4

I TABLE 1.2-1 I

BR7 610* 671 Reviston 2 SYRON NUCLEAR POWER STATIOlt I

CNIT I DOCKET NUMBER 5718 50 _4.16 _

RADICACTIVE EFFLCENT RELEASE REPCRT January

.1994 THROUGH fune f o o t.

I LIOCTID RFFLUEFFS - StM GLTION OF ALL RELEASES UNITS 15T QTR 2ND OTR 3RD QTR 4TH 7TE L.

FISSION AND ACTIVATION GAS RELEASES 1.

Total Activity Released Ci 9.23E-3 5.10E-2 h

2.

Average Concentratics: Reisased uCi/ml for Quarter 3.

4 of 10CFR50 Limits a.

Quarterly Whole Body (1.5 mram) t 0.03 0.05 I

b.

Quarterly Any Organ (5.0 mrea) t 0.01 0.02 c.

Annual Whole Body (3.0 mrea) t 0.01 0.03 d.

Annual Any Organ (10.0 mrea) t 0.01 0.01 M.

TRITItEl 1.

Total Activity Released Ci 1.95E+2 3.22E+2 2.

Average Concentration Released uCi/ml 7.64E-5 1.21E-4.

for Quarter 3.

t of Limit (1.005 3 uCi/ml) t 7.64 12.12 N.

DISSOLVED NOBLE GASES 1.

Total Activity Released Ci 7.38E-4 4.49E-3 2.

Average concentration Released uci/ml for Quarter 3.

t of Limit (2.003 4 uC1/ml) t 1.44E-4 8.47E-4 I

O.

GROSS ALPHA 1.

Total Activity Released Ci j

<LLD

<LLD I

2.

Average Concentration Released uCi/ml 0.00 0.00 for Quarter P.

VOLUME OF 10LSTE RELEASED FER UNIT liters 2.10E+6 2.68E+6 i

I Q.

V01I2tB OF DIIRIZON ICLTER PER UNIT liters 2.5bE+9 2.65E+9 l

18

7..

L..-

TABLE 1.2-1 (continued) 1 STRON NWCir.Ak POWER $TATION UNIT 1 DOCKET NUMBER STN L RADIDACTIVE EFFLUENT RELEASE REPCRT JULY

,1994 THROUGH DECEMBER 1994 tf 00!D Errf. VENTS - StHMAff 0M OF M L #fLEASES (CONT)

UNITS IST QTR 2ND QTR 3AD QTR 4TH QTR ;

L.

F15$20N AND ACTIVATION PRODUCT RELEASES 1.

Total Actavity Released C1 1.00E+0 2.0$E+0 2.

Average concentration Released uti/ml for Quarter g

3.

t of 10 err 50 Limats a.

Quarterly whole Body (1.5 mrem) b.

Quarterly Any organ (5.0 mreal t

0.04 0.34 c.

Annual Whole Body (3.0 mrom) 4 0.02 0.05 d.

Annual Any organ (10.0 mrom) g 0.02 0.17 M.

TRIT!UM 1.

Total Activity Released C1 2.37E+2 1.58E+2 2.

Average Concentration Released uC1/a1 for Quarter 9.75E-S 6.12E-5 3.

t of 10CTR20 Limit t

9.75 6.12 (1.00E-3 uC1/ml)

N.

DISSOLVED NOBLE CASES 1.

Total Activity Released C1 2.87E-2 5.89E-2 2.

Average Concentration Released uC1/m1 1.18E-8 2.28E-8 for Quarter 3.

5 of Admin Tech Regt. Limit t

5.91E-3 1.14E-2 t2.00E-4 uC1/ml)

O.

CROSS ALPHA 1.

Total Activity Released C1 (LLD (LLD 2.

Average Concentration Released uci/a1 0.00 0.00 for Quarter P.

VOLUME OF WASTE RELEASED PER UNIT liters 3.74E+6 4.06E*6l l

2.43E+9l2.58E+9l Q.

VOLUME OF DILUTION WATER PER UNIT 11 tere I

19 I

BRJ 6100 671 TABLE 1.2-1 (continued) lI l

BYRON NUCLEAR POWER STATION UNIT 2 DOCKrF NUMBER SDI 50- 455 RADICACTIVE BFFLUENT RELEASE REPORT January 1994 ntROUGH June 1994 LIOC7ID EFFLUENTS - SUMPOLTION OF ALL RELEASES (CONT)

UNITS IST QTR 2ND QTR 3RD QTR 4TH Qn I

L.

FISSION AND ACTIVATION GAS RELEASES

~

I 1.

Total Activity Released Ci 9.23E-3 5.10E-2 2.

Average Concentration Released uCi/ml for Quarter 3.61E-9 1.92E-8 3.

% of 10CFR50 Limits lI 5

a.

Quarterly Whole Body (1.5 miem) t 0.03 0.05

'I b.

Quarterly Any Organ (5.0 mrem) 0.01 0.02 c.

Annual Whole Body (3.0 arem) 0.01 0.03 d.

Annual Any Organ (10.0 mram) 0.01 0.01 I

M.

TRITIUM 1.

Total Activity Released Ci 1.95E+2 3.22E+2 I

2.

Average Concentration Released uCi/ml for Quarter 7.64E-5 1.21E-4 3.

% of Limit (1.00E 3 uCa/ml) 7.64 12.12 N.

DISSOLVED NOBLE GASES I

1.

Total Activity Released Ci 7.38E-4 4.49E-3 2.

Average Concentration Released uCi/ml for Quarter 2.89E-10 1.69E-9 3.

% of Limit (2.00E 4 uCi/ml)

O.

CROSS ALPHA 1.

Total Activity Released Ci

<LLD

<LLD 2.

Average Concentration Released uC1/ml for Quarter 0.00 0.00 P.

VOLUME OF WASTE RELEASED PER UNIT liters 2.10E+6 2.68E+6 Q.

VOLUME OF DILUTION WATER PER UNIT liters 2.56E+9 2.65E+9 I

20 I

nL>

rm LJ TABLE 1.2-1 (continued) 87 ROM NUCLEAR POWER STATION UNIT 2 DOCKET NVMBER STN 499 RADIDACTIVE ETTLUENT RELEASE REPORT DECEMBER 1994 JULY

,1994 THROUCH LioUfD ErrLUENTS - SUMMATION OF ALL RELEASES (CONT)

UNITS IST QTR 2ND QTR 3RD QTR 4THQTRl L.

TISSION AND ACTIVATION PRODUCT RELEASES 1.

Total Activity Released CA 1.00E+0 2.05E+0 2.

Average Concestration Released uC1/mi 4,12g.7 7.95E-7 for Quarter f

3.

t of 10CFR50 Limits a.

Quarterly Whole Body 0.05 0.10 (1.5 mrem) b.

Quarterly Any Organ o,04 0.34 (5.0 mrem) c.

Annual Whole Body 0.02 0.05 (3.0 mrem) 4 d.

Annual Any Organ 0.02 0.17 (10.0 mrem) t M.

TRITIUM 1.

Total Activity Released C1 2.37E+2 1.58E+2 2.

Average Concentration Released uci/ml 9.75E-5 6.12E-5 for Quarter 3.

t of 10CTR20 Limit 4

9.75 W

(1.00E-3 uC1/ml)

N.

DISSOLVED NOBLE CASES

~

1.

Total Activity Released C1 2.87E-2 5.89E-2 2.

Average concentration Released uCi/mi 1.18E-8 2.28E-8 for Quarter 3.

4 of Admin Tech Regt. Limit 5.91E-3 1.14E-2 (2.00E-4 uC1/al)

O.

CROSS ALPMA 1.

Total Activity Released C1

<LLD (LLD 2.

Average Concentration Released uci/ml for Quarter 0.00 0.00 P.

VOLUME OF WASTE RELEASED PER UNIT liters 3.74E+6 4.06E+6 Q.

._ O,,, L.,T_.,E R,ER - T

,,t...

. 4,E.,

..,,E.,

21 e

TABLE 2.0-1 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN 50 454/455 RADIOACTIVE EFFLUENT RELEASE REPORT January 1994 THROUGH June 1994

[

SOLID RADIOAC* RIVE WM,II Ist OUARTER 1994 IEM I

DISPOSITION OF MATERIAL VOLUME (DESCRIPTION, CLASS, MDDE PER CURIES TYPE, AND SOLIDIFYING OF SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CUBIC FT SHIPMENT I

02-11-94 Dewatered bead resin,' Class A Exclusive

Barnwell, 199.4 3.21 Unstable, Liner, None Use S.C.

02-18-94 Filters, Class A Stable HIC, Exclusive

Barnwell, 132.4 14.6 None Use S.C.

l I

I I

331.8 17.81 2

QUARTERLY WTALS - FUMBER OF SHIPMENTS:

gg3ge y7 cggggs I

I 22

E

=-

TABLE 2.0-1 (Continued)

BRP 6100 671 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE BFFLUENT RELEASE REPORT January 1994 THROUGH June 1994 SOLID RADICAC"fIVE WASTg 2nd OUARTER __l,994 M

I DISPOSITION OF MATERIAL VOLUME (DESCRIPTION, CLASS, IODE PER CURIES TYPE, AND SOLIDIFYING OF SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CDBIC FT SHIPMENT 04-05-94 Dewatered Bead Resin, Class B Exclusive

Barnwell, 132.4 68 Stable, HIC, None Use S.C.

04-18-94 DAW, Class A Unstable, Drums, Exclusive

Barnwell, 105 3.08 None Use S.C.

05-03-94 Dewatered Bead Resin, Class A Exclusive

Barnwell, 199.4 3.59 Unstable, Cask, None Use S.C.

05-10-94 Filters, Class B Stable HIC, Exclusive

Barnwell, 132.4 69 None Use S.C.

05-17-94 Dewatered Bead Resin, Class A Exclusive

Barnwell, 199.4 9

Unstable Cask, None Use S.C.

05-24-94 Dewatered Bead Resin, Class A Exclusive

Barnwell, 199.4 12 Unstable. Cask, None Use S.C.

06-07-94 DAW, Class A Unstable, Drums.

Exclusive

Barnwell, 399.6 0.479 None Use S.C.

06-10-94 Dewatered Bead Resin, Class A Exclusive

Barnwell, 199.4 0.26 Unstable, Cask, None Use S.C.

(Continued ca Page 19 of 23) g 193,.s le,.,2 CCARTERLY TCTTALS - NUMBER OF SHIPMENTS:

10 CUBIC FT CURIES I

I 23

TABLE 2.0-1 (continued)

BRP 6100 671 Revision 2 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKrr NUMBER STN-50-454/455 RADICAC*TIVE EFFIDErr RELEASE REPORT Januarv 1994 THROUGH June 1994 SOLID RADIOACTIVR WASTE 2nd ODARTER 1994 _ M I

DISPOSITION OF ICLTERIAL VOLUMI (DESCRIPTION, CLASS, IODI PER CURIES I

TYPE, AND SOLIDIFYING OF SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CCBIC FT SHIP 22Nr 06-17-94 Dewatered Bead Resin, Class A Exclusive

Barnwell, 170.2 0.535 Unstable, Cask, None Use S.C.

06-27-94 Dewatered Bead Resin & Filters.

Exclusive

Barnwell, 202.1 1.78 Class A Stable, HIC, None Use S.C.

I I

I (Totals

>n Page) 18 o f 23

@3LRTERLY TCfrAI.S - NUMBER OF SHIPMErrS: (See Pace 18 of 23)

CUBIC FT CURIES l

1 24

Oo TABLE 2.0-1 (continued)

Revision 3 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET.4 UMBER S7W-50-454/455 RADICACTIVE EFFLUENT DELEASE REPORT JULY

,1994 THROUCH DECEMBER 1994 SOLID RADIOACTIVE WASTE 3& 4 OUARTER 1994

%IAg DISPOSITION OF MATERIAL VOLUME (DESCRIPTION, CLASS, ME PER CURIES TYPE, AND SOLIDIFYING OF SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CUBIC FT SHIPMENT There were no soAid radioactive waste shipments for 3rd and 4tr quarters of 1994.

I I

I 0

0 QUARTERLY TOTALS - NUMBER OF SHIPMDrTS:

CUBIC FT CURIES I

I' 25 avi

l i

FIGURE 3.1-1

/

l Estimated Cumulative Gamma Dose (in mrem)

)

7 L

l from the Byron Station for the period I

January-December 1994 p'

50 l

lsoofeth Labels f

!il l

Small figure - multiply by 10

(-

5.

4 Large figure - multipty by 10 l

2s D

?

  • Pocetonice ROC D

I

/y I

/

I

, J......

a s

[

V

/

l I

.... Y.

\\

it I

I 9

25 I

I I

2g -

26 I

Ea FIGURE 3.1-2 m

g bloo Esbmated Total Concentrations (in pCi/m3) of Noble Gases from the Byron Station

~

~

for the period January December 1994 h-j a men ut.a i ?

2 s

Small figure multipty by 10 i"

Large figure - muttply by 10

25 8

e

  • Pecolonice ROC K FOR D,,,,

~.-

N

\\_

I i

-o

~).......

I 3

23

[

{"i

],,

\\

(

g-I 4,......

I

...... V

,d "

(

50 1

5 ei...

I N

I I

e.....

2 I

2,

.a

FIGURE 3.1-3

!l Estimated Total Concentrations (in pCi/m3)

E of lodine from the Byron Station for the period January-December 1994 I

y

  • ,l There were no iodine releases.
  • a

/

/

fg N

V, 2*

' Pecatonica R.CaroRD_

-to

'I 7

~ I s..

/

I 3*,........

e,.

ra i

J ra i s

.5 E

"a" i s I

I I

S

*je* f "

Dison N

g lg

,o.

=

28

E O

FIGURE 3.1-4 y&

30 Estimated Total Concentrations (in pCi/m3) 5:

I of Particulates from the Byron Station 3o for the period January-December 1994

[

250 l

l liooteth Labets

(

h*

}

I 8

Small figure rnuftsply by 10 g

Large figure multiply by 10*

i j

25 100 1

3 u

i ll o

e u

nocuroRD.

I

/

I h,......... [

(

g M

k 30 0

$O0 ta me.

es j

~

i I

' u s

' A

,.....n.

,)'

N g

I l

,e 4

r --

29 s=

TABLE 3.1-1 BYRON STATION UNIT ONE ACTUAL 1994 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 04/13/95 INFANT RECEPTOR l

IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 2.65E-06 3.94E-06 1.82E-06 2.25E-05 3.09E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 4.85E-06 6.53E-06 6.32E-06 9.14E-05 1.09E-04 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 1.95E-06 2.90E-06 1.31E-06 1.58E-05 2.20E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

I SKIN 4.10E-06 5.96E-06 3.97E-06 4.53E-05 5.94E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

l ORGAN 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1

(MREM)

(

)

(

)

(

)

(

)

(

)

I l

THIS IS A REPORT FOR THE CALENDAR YEAR 1994 iI l

COMPLIANCE STATUS - 10CFR 50 APP. I INFANT RECEPTOR


 % OF APP I.

QTRLY IST QTR 2ND OTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OLJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 l

BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM' 2.5 0.00 0.00 0.00 0.00 5.0 0.00

'I SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 l

l RESULTS BASED UPON:

ODCM ANNEX REVISION 1.2 AUGUST 1994 ODCH SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

I

.I

O O

TABLE 3.1-1 (continued)

BYRON STATION UNIT ONE ACTUAL 1994 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 04/13/95 ADULT RECEPTOR l

1ST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 2.65E-06 3.94E-06 1.82E-06 2.25E-05 3.09E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 4.85E-06 6.53E-06 6.32E-06 9.14E-05 1.09E-04 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

l TOT. BODY 1.95E-06 2.90E-06 1.31E-06 1.58E-05 2.20E-05 I

(MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 4.10E-06 5.96E-06 3.9?S-06 4.53E-05 5.94E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 3.65E-05 1.94E-04 2.81E-05 2.70E-05 2.61E-04 (MREM)

(SSE )

(SSE )

(SSE )

(S

)

(SSE )

LIVER LIVER GI_LLI LIVER GI_LLI THYROID THYROID TRYROID KIDNEY KIDNEY KIDNEY LUNG LUNG LUNG GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1994 COMPLIANCE STATUS - 10CFR 50 APP. I I

ADULT RECEPTOR l

i

____.------- % OF APP I.

l lll QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I E i GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 l

SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LIVER LIVER GI_LLI LIVER GI_LLI THYROID THYROID THYROID KIDNEY KIDNEY KIDNEY LUNG LUNG LUNG GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.2 AUGUST 1994 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 31 ali

TABLE 3.1-1 (continued)

BYRON STATION UNIT TWO ACTUAL 1994 MAXIMUM DOSES RESULTINC FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 04/13/95 I

INFANT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL I

JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 1.10E-06 1.76E-06 2.77E-06 3.61E-06 9.25E-06 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 2.74E-06 5.45E-06 8.75E-06 7.74E-06 2.47E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 8.03E-07 1.27E-06 2.00E-06 2.67E-06 6.74E-06 (MR EM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.95E-06 3.20E-06 5.67E-06 6.97E-06 1.78E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MREM)

(

)

(

)

(

)

(

)

(

)

I THIS IS A REPORT FOR THE CALENDAR YEAR 1994 I

COMPLIANCE STATUS - 10CFR 50 APP. I I

INFANT RECEPTOR

% OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF I

OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00

)

i dETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 l

TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 l

I SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (KREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 RESULTS BASED UPON:

ODCM ANNEX REVISION 1.2 AUGUST 1994 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

II l

,I 32 l

I

I C

Ul J

TABLE 3.1-1 (continued) 4 l

{

t BYRON STATION UNIT TWO i

l ACTUAL 1994 l

MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/94 'IO 12/31/94 CALCULATED 04/13/95 ADULT RECEPTOR l

IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 1.10E-06 1.76E-06 2.77E-06 3.61E-06 9.25E-06 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 2.74E-06 5.45E-06 8.75E-06 7.74E-06 2.47E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 8.03E-07 1.27E-06 2.00E-06 2.67E-06 6.74E-06 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.95E-06 3.20E-06 5.67E-06 6.97E-06 1.78E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 7.33E-05 1.28E-04 1.24E-04 4.88E-05 3.30E-04 (MREM)

(SSE )

(SSE )

(SSE )

(S

)

(SSE )

LIVER LIVER LIVER GI_LLI GI_LLI THYROID THYROID THYROID KIDNEY KIDNEY KIDNEY LUNG LUNG LUNG GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1994 l

l COMPLIANCE STATUS - 10CFR 50 APP. I ADULT RECEPTOR l


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD OTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LIVER LIVER LIVER GI_LLI GI_LLI THYROID THYROID THYROID KIDNEY KIDNEY KIDNEY LUNG LUNG LUNG GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.2 AUGUST 1994 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l l

l l

l 33 l

l m1 L______________________________________________

L TABLE 3.2-1 f~

L BYRON STATION UNIT ONE ACTUAL 1994 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS m

PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 04/13/95 ADULT RECEPTOR IST 2ND 3RD 4TH h

DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.99E-04 6.53E-04 6.82E-04 1.47E-03 3.20E-03 f

BODY L-INTERNAL 4.77E-04 9.63E-04 1.84E-03 1.72E-02 2.03E-02 ORGAN LIVER GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1994 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY 1ST QTR 2.iD QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR AP?-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.03 0.0<

0.05 0.10 3.0 0.11 L

CRIT. ORGAN (MREM) 5.0 0.01 0.02 0.04 0.34 10.0 0.20 LIVER GI_LLI GI_LLI GI_LLI GI_LLI

'7-"'TF BASED UPON:

ODCM ANNEX REVISION 1.2 August 1994 ODCM SOFWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

L

[

E W

[

C0 TABLE 3.2-1 (continued) i BYRON STATION UNIT TWO ACTUAL 1994 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 04/13/95 E

l ADULT RECEPTOR g

IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.99E-04 6.53E-04 6.82E-04 1.47E-03 3.20E-03 I

BODY l

INTERNAL 4.77E-04 9.63E-04 1.84E-03 1.72E-02 2 03E-02 l

ORGAN LIVER GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1994 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.03 0.04 0.05 0.10 3.0 0.11 CRIT. ORGAN (MREM) 5.0 0.01 0.02 0.04 0.34 10.0 0.20 LIVER GI_LLI GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.2 August 1994 ODCM SOF'1%'ARE VERSION 1.1 January 1995 W

ODCM DATABASE VERSION 1.1 January 1995 l

x 5.

TABLE 3.3-1 BYRON STATION UNIT ONE 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/94 TO 12/31/94 CALCULATED 04/13/95 I

1.

10 CFR 20.1301 (a) (1) Compliance

'I Total Effective Dose Egivalent, mrem /yr 5.82E-03 10 CFR 20.1301 (a) (1) limit mrem /yr 100.0

% of limit 0.01 I

I Compliance Summary - 10CFR20 1st 2nd 3rd 4th t of Otr Otr Qtr Qtr Limit TEDE 3.06E-04 7.50E-04 8.12E-04 3.95E-03 0.01 RESULTS BASED UPON: ODCM ANNEX REVISION 1.2 AUGUST 1994 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l l

I g

I g

36

U O

TABLE 3.3-1 (continued)

BYRON STATION UNIT TWO 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/94 TO 12/31/94 CALCULATED 04/13/95 I

1.

10 CFR 20.1301 (a) (1) Compliance Total Effective Dose Egivalent, mrem /yr 5.84E-03 10 CFR 20.1301 (a)(1) limit mrem /yr 100.0

% of limit 0.01 Compliance Summary - 10CFR20 ist 2nd 3rd 4th

% of Otr Otr Otr Qtr Limit TEDE 3.27E-04 7.08E-04 8.60E-04 3.95E-03 0.01 RESULTS BASED UPON: ODCM ANNEX REVISION 1.2 AUGUST 1994 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

l I

37 5=

l I~L FIGURE 5.0-1 m

l" BYRON Revision 12 e.o August 1994 m

y fl

~

\\

='I' ~ s*-

g

/.%-.

,,, /

Ak, a w. -,....

i1 %

y imO

[IT j

m (, w

-j Y

... N.

". s..

a8

\\

m p

,V

.?

.. a -

n I

J

..., _/ e' g, I

\\

~-

.Y.

1 y

L j

ene.

'.y h

f '"'

j u" *'

/

{

_ ' ~

e,:

j x

." a

.J

_w e,,

t g.

~

>sti f

e; Val

+"*'

. =.-s

]

]

d m:

\\

/ s.-

~

).

=

J, Fg - ~ ~' 4--

/

h..

g

'-' 3 o

Smi G

g A'

3;

  • Q~'. *

/

~~

U.

r

.... _ ~.

i,

~

n s

9.a a

sa 5

.D

'r-n-

I I

~

t 2

7 s

2

>=_

y 1

t

. s.,

tgt,s. c j

j

..I

' dl, )'

~ab E

x rI

\\

.,. 3

. V' -

..- /

.,, i L

i l

~"' ]

~'

i=?'

F'

f T~d d4(,.

't Oregon j ay)nl\\

fyt-

...tp-

.- g

-uM

  • /i ti

/_

E BYRON STATION TLD Location N1

[

Y INNER AND OUTER RING TLD LOCATIONS 38

Oo FIGURE 5.0-2 E,

g1

[

g*

c 08 R tt Scor7 ag w

Leef River 9 01 0,

elley O

8YRON e 03

/

STATION vt.,

Mortes f'1

[

E.

Peines

{

reint I

OS 04 e

/

0988

\\

n. sa I

0 1

2 3

4 5 MILES 5

1,0 Kne$

BYRON STATION Air Sampling Locat.on a Byron Staten FIXED AIR SAMPLER LOCATIONS BY41 Byron BY-02 Stillman Valley BY-03 Nearsite-East BY-04 Paynes Point BY-05 Nearsite South BY46 Oregon BY47 Mt. Morris BY 08 leaf River BY-21 Byron Nearsite North BY-22 Byron Nearsite East Southeast BY-23 Byron Nearsite South BY 24 Byron Nearsite Southwest 39 s.

FIGURE 5.0-3 F

M l

r N

l f

i e

s E

~

II

gn scott no, f'

E M.',,

  • X/

i 13

$lillmea

~

I Valter o

8YRON ut ST,ATION 1

Mortis 18

\\

F, 88 I L f ndertwoo Rd.

\\

w

(

0 aines 12 Oregon

.g. se Rett 0

1 2

3 4

5 ulLES t

e i

e e

i i

10KMS e

e N

BYRON STATION WATER SAMPLE LOCATIONS L

weier BY.o, w eetiao,C,ee,

O Byron Station BY-12 Oregon Pool of Rock River, Downstream BY-13 Rock River, Upstream BY-14 CECO Offsite Well BY 18 McCoy Farmstead BY 29 Byron, Upstream 40 W

Eo-FIGURE 5.0-4 326 l

I o-l 4

1 II'"

gn scott no, t

520

$lillmes 28 g

/

ygig,y o

I

=

I BYRON 1

g g,

/

$7ATION k

Wettis

~

\\ F,

8 L f riderNoo Rd.

327 g-(

le I

L Oregos

.g...

g 0

1 2

3 4

5 MILES l

3 9

5

'ca BYRON STATION MILK SAMPLE LOCATIONS O

Byron Station BY 20 K. Reeverts Dairy Farm BY.26 Clenliszzard's Dairy BY-27 Kenneth Druien Dairy Farm BYSP-28 Duane Camhng Dairy Farm BY-30 Don Roos Da5 y s

I 41 I"1

TABLE S.0-1 t

Byron Station

~

Radiological Environmental Monitoring 3

m Locations y

g

_E 5

k N

E D

E y

i F

o m

b Y

s R

6--

U h.

2 35 g

BY-01 Byron 0

0 BY-02 Stillman Valley 0

0 BY-03 Nearsite - East 0

0 BY-04 Paynes Point 0

0 BY-05 Nearsite South 0

0 I

BY-06 Oregon 0

0 BY-07 Mt. Morris 0

0 BY48 Leaf Road 0

0 BY-09 Woodland Creek O

BY-12 Oregon Pool of Rock River, Downstream 0

0 0

BY-13 Rock River, Upsteam 0

0 0

BY-14 CECO Offsite Well 0

BY-18 McCoy Farmstead O

BY-19-1 River Road Across from BY-01 0

I BYSP-19-2 German Church Road 0

BYSP-19-3 6773 River Road 0

BY-20 K. Reeverts Dairy Farm O

BY-21 Byron Near Site N 0

0 BY-22 Byron Near Site ESE O

O BY-23 Byron Near Site S 0

0 BY-24 Byron Near Site SW 0

0 BY-26 Glen Hazzard's Dairy 0

BY-27 Kenneth Druien Dairy Farm

.O BYSP-28 Duane Camling Dairy Facm 0

BY-29 Byron, Upstream 0

0 0

BY-30 Don Roos Dairy O

BYSP-31 Byron, Discharge 0

CENSUS Dairy Residence Cattle I

I I

I 42

1 TABLE 5.0-2 BYRON STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM, SAMPLING LOCATIONS

1. AIR SAMPLERS Distance Direction Site Codea Location (miles)

(0)

I BY-01 Byron 3.5 25 BY-02 (C)

Stillman Valley 6.2 56 I

BY-03 Nearsite - East 3.8 85 BY-01 Paynes Point 4.5 140 BY-05 Nearsite - South 3.6 180 BY-06 Oregon 4.6 213 I

BY-07 (C)

Mt. Morris 7.8 240 BY-08 (C)

Leaf River

'0 315 BY-21 Byron Nearsite North u.3 9

I-. -

BY-22 Byron Nearsite East-Southeast 0.3 101 BY-23 Byron Nearsite South 0.6 182 BY-24 Byron Nearsite Southwest 0.7 229 I

2.

IJlh a.

Same as No.1.

b.

SpecialTLD Samplers Distance Direction Sjte Code (miles)

_,0L Inner Ring BY-102-1,2 1.0 25 BY-103-1,2 1.7 51 BY-104-1,2 1.4 64 BY-105-1,2 1.3 84 BY-106-1,2 1.4 108 BY-107-1,2 1.4 141 BY-108-1,2 0.6 158 BY-109-1,2 0.6 183 BY-110-1,2 0.6 201 I

BY-111-3,4 0.8 224 BY-112-3,4 0.8 255 BY-113-1,2 0.7 270 I

BY-114-1,2 0.8 298 BY-115-1,2 1.0 314 i

BY-116-1,2 1.4 329 a Control (background) locations are denoted by a C" ef er site code. All other locations are indicators.

t I

43 I

Oo TABLE 5.0-2 (continued)

BYRON STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM, SAMPLING LOCATIONS

2. TLDS b.

Special TLD Samplers (continued)

Distance Direction Site Codea (mdes)

(0}_

Outer Ring BY-201-1,2 4.5 360 BY-272-1,2 4.5 13 BY-203-1,2 5.1 42 BY-204-1,2 4.2 66 BY-205-1,2 3.9 89 g

BY-206-1,2 4.2 112 m

BY-207-1,2 4.2 140 BY-208-1,2 4.1 159 BY-209-1 3.8 189 BY-209-4 3.6 189 BY-210-3,4 4.8 203 BY-211-1 5.2 238 BY-211-4 4.9 238 BY-212-1,4 4.9 257 BY-213-1 5.0 270 BY-213-4 4.8 270 BY-214-1,4 4.8 298 BY-215-1,4 5.2 322 BY-216-1,2 4.8 337

3. MILK Distance Direction Site Codea Location (miles)

(0)_

UY-20 K. Reeverts Dairy Farm 2.1 37 BY-26 (C)

Glen Hazzard's Diary Farm 13.5 355 BY-27 Kenneth Druien Dairy Farm 5.8 244 BYSP-28 Duane Camling Dairy Farmb 3.2 305 BY-30 Don Roos Dairy 5.1 125 I

a Control (background) locations are denoted by a "C" after site code. All other locations are indicators.

b Additional dairy was not required by ODCM but was included to ensure that program has at least l

four dairies B

44 i

z

TABLE 5.0-2 (continued)

BYRON STATION RADIOLOGICAL ENVIRONhiENTAL hiONITORING PROGRAhi, SAh1PLING LOCATIONS

4. VEGETABELS Distance Direction Site Code Location (miles)

__.10L._

l-BY-19-1 River Road Across from BY-01 2.7 25 BYSP-19-2 German Church Road 3.6 180

,I BYSP-19-3 6773 River Road 3.0 350

5. GROUND /WELL WATER Distance Direction Site Code Location (miles)

JOL__

BY-14 CECO Offsite Well 0.3 101 BY-18 hicCoy Farmstead 1.0 235

6. S_URFACE WATER g

Distance Direction

B Site Code Location (mdes)

(0) _

g BY-09 Woodland Creek 2.1 320 g

BY-12 Oregon Pool of Rock River, Downstream 4.5 213 BY-13 (C)

Rock River, Upstream 2.6 302 BY-29 (C)

Byron, Upstream 3.5 25

7. EISli Distance Direction Site Code Location (mdes)

J 1__

0 BY-12 Oregon Pool of Rock River,

'I Downstream 4.5 213 BY-13 (C)

Rock River, Upstream 2.6 302 BY-29 (C)

Byron, Upstream 3.5 25 BYSP-31 Byron, Discharge 2.5 282 9.

$1IORELINE SEDIMENTS

'I Distance Direction Site Code Location (miles)

J0)__

BY-12 Oregon Pool of Rock River, I

Downstream 4.5 213 BY-13 (C)

Rock River, Upstream 2.6 302 BY-29 (C)

Byron, Upstream 3.5 25 a Control (background) locations are denoted by a "C" after site code. All other locations are indicators.

I 45

TABLE 5 0-2 (continued)

BYRON STATION RADIOLOGICAL ENVIRONMENTAL MONTIORING PROGRAM, SAMPLE COLLECTION AND ANALYSES Location Collection Type of Frequency Sample Media Codea Site Frequeng Analysis of Analysis Remarks 1.

Airborne Onsne and Near Field Continuous Gross Beta Weekly On all samples.

Partrulates operation Filter Weekly BY41 Bymn for a week exchange BY-02 (C)

Stillman Valley Gamma Isot.

Quarterly On Quarterly composite from eadi location.

BY-03 Nearsite - East Gamma Isot.

Weekly Gamma isotops if gmss beta in a sample BY-04 Paynes Point exceeds SX the average concentration of BY45 Nearsite - South the precedmg calendar quarter for the BY-06 Oregon BY-07 (C)

Mt. Morris BY-08 (C)

Isaf River BY-21 Byron Nearsite North BY-22 Byron Nearsite East-Southeast BY-23 Byron Nearsite South BY-24 Byron Nearsite Southwest 2.

Airborne Same as 1.

Continuous 1-131 Weekly On all samples.

g Iodine operation forone weeks l

l 3.

AirSamphng Same as 1-Test and Weekly On all samples.

Tram j

Maintenance 4.

TI.D

a. Same as 1.

Quarterly Gamma Quarterly Twosetsof TLD' sat allairsampler kutions. All sets read Quarterly.

b.

BY-102-1,2 Inner Ring Quarterly Gamma Quarterly All sets read Quarterly.

103-1,2 104-12 105-1,2 106-1,2 107-12 108-1,2 109-1,2 110-1,2 111-3,4 112-3,4 113-1,2 114-1,2 115-1,2 116-1,2 8 Control (backgmund) locations are denoted by a "C" in this column. All other locations are indicators.

l l

ll M

M M

M M

M M

M E

1

i 3

m3m m

m m

m

-- g -

--~

mm n

n r

TABLE 5.0-2 (continued)

BYRON STATION RADIOLOGICAL ENVIRONMENTAL MONTIORING PROGRAM, SAMPLE COLLECTION AND ANALEES 12 ration Collection Type of Frequency Sample Media Codea Site Frequency Analyss of Analysis Ih narks i

l 4.

R.Ds b.

BY-201-3,4 Outer Ring Quarterly Gamma Quarterly All sets read Quarterly.

]

(continued) 202-1,2 1

203-1,2 204-1,2 205-1,2 i

206-1,2 l

207-1,2 208-1,2 209-1,4 210-3,4 211-4 212-1,4 213-1,4 t

214-1,4 f

215-1,4 216-1,2 u

5.

Milk BY-20 K. Reeverts Dairy Farm Semimonthly-I-131 Semimonthly-On all samples.

N BY-26 (C)

G. Ilazzards Dairy May -October Gamma Isot.

May-October b

BY-27 K Druien Dairy Farm BYSP-28 D. Camimg Dairy Farm Monthly:

1-131 Monthly-On all samples.

BY-30 D. Roos Dairy November. April Gamma Isot.

November-April 6.

Vegetables BY-19-1 Rivt Road Accross from Annually at Gamma Isot.

Annually Four Vaneties from each location as BY-01 harvest available at harvest. (Gamma isotopic BYSP-19-2 German Church Road an edible portion on!y).

BYSP-19-3 6773 River Road 7.

Groung/Well BY-14 CECO Offsite Well Monthly Cross Beta Monthly On all samples.

Water Gamma Isot.

Monthly On a!! samphs.

BY-18 McCoy Farmstead Tntium Monthly On all camples.

8.

Surface Water BY-09 Woodland Creek Weekly Tritium Quarterly On quarterly composite from each kration.

BY-12 Oregon Poolof Rock Gamma Isot.

Monthly On monthly composite from each location.

Rsver, Downstream BY-13 (C)

Rock River, Upstream BY-29 (C)

Byron Upstream a Control (background) locations are denoted by a "C" in this column. All other locations are indicators.

b Additionaldairy was not required by ODCM but included to assure that the program has at least four dairies.

TABLE 5.0-2 (continued)

BiRON STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM, SAMPLE COLLECTION AND ANALYSES Location Collection Type of Frequency Sample Media Codea Site Frequency Analysis of Analym Remarks 9.

Fish BY-12 Oregon Poolof Rock Three times Gamma Lsot.

Three times From Ore 3pn Pool of Rock Rwer, on River, Downstream a year a year edible portens only. At least two species.

BY-13 (C)

Rock Rwer. Upstream spring, summer, BY-29 (C)

Byron, Upstream and fall BYSP-31 Byron, Discharge 11.

Shorehne BY-12 Oregon Poolof Rock Semiannually Gamma Isot.

Semiannually On all samples.

Sediments River, Downstream BY-13 (C)

Rock River, Upstream BY-29 (C)

Byron, Upstream 12.

Land Use Census Milch Animals

a. Site boundary to 2 miles
a. Enumeration by Annually During grazing seasort a door to door or equivalent counting technique.
b. 2 miles to 5 miles
b. Enumerationby Annually During grazing seasort 3

<m using referenced information from county agricultural agents or other rehable sources.

c. At dairies listed in Item 5.

~

c. Inquire as to Annually During grazing seasort feeding practices:
1. Pastureonly.
2. Feed and chop only.
3. Pasture and feed:if both, ask farmer to estimate fraction of food from pasture-25 %, 25-50 %, 50-75 %

or 75%

Nearest In all15 sectors up to 5 miles Annually Residence Census a Control (background) locations are denoted by a *C"in this column. All other locations are indicators.

l l

l IM M

EE

m M

M M

M M

M m

m M

m TABLE 5.0-3 RADIOLOGCAL ENVIRONME.NTAL MONrrORING PROGRAM QUARTERLY

SUMMARY

N me of Faniity Bvron Nuclear Power Station Dccket No._50-151. 50-455 Location of Faahty Ocle. Illmms Reporting Period 1st Ouarter 1st (County, State)

Sample Type and Indicator Location with liighest Control Number of Type Number of locations Ouarterly Mean Locations Non-routine (Umts)

Analyses LLD a

a Mean Mean Mean Results Range Location Range Range Atr Particulates Gross Beta 155 0.01 0.025 (116/116)

BY 06,gm 0.026 (13/13) 0.025 (39/39) 0 b

(pCi/m )

(0.011-0.044) 4 6 mi @ 213' (0.01(>o.041)

(0.014 4 040)

Gamma Spec.

12 Cs-134 0.05

<tLD

<tLD 0

Cs-137 0.06

<LLD

<LLD 0

Airbome lodme I-131 155 0.07

<LLD

<LLD 0

3 (pCi/m )

Background

Gamma IAwe 90 3

14.9 (84/54)

BY-206, 23.5 (2/2) 13.5 (6/6)

Gl.Ds) (mR/Qtr-)

(11.2-23.5) 42 mi @ 112*

(13.1-14 3)

O Milk I-131 15 1

(LLD

<LLD 0

(pCi/L)

Gamma Spec.

15 A*

Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Ba-La-140 15

<LLD

<LLD 0

Other Gammas 20

<tLD

<I.LD 0

Surface Water Gamma Sper.

10 (pCi/L)

Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Other Gammas 15

<LLD

<LLD 0

Tntium 4

200 1,391 (1/1)

BY-12, Oregon Pool 1,391 (1/1)

<LLD 0

of Rock River 4.5 mi @ 213*

Well Water Gruss Beta 6

4

<LLD None 0

(pCi/L)

Gamma Spec.

6 Cs-134 15

<tLD None O

Cs-137 18

<LLD None 0

Other Gammas 15

<LLD None 0

Tntium 6

200

<LLD None 0

  • Mean and range based on detectable measurements only. Fractions indicated in parentheses.

b 3

Locations BY46, BYM, and BY-72 had identical means of 0.026pCi/m. Only BY-06 is detsiled in this summary.

TABLE 5.0-4 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM QUARTERLY

SUMMARY

Name of Facility Byron Nuc! car Power Station Docket No. 50 4 54. 50-455 Location of Facility 021e Imms Reporting Pered 2nd Ouarter 19M (Cmmtv, State)

Sample Type and Indicator Location with Highest Control Number of Type Number of locations Ouarterly Mean Locations Non-routine (Umts)

Analyses LLD a

a Results y,,n Mean Range Mean Range Location Range Air Particulates Gross Beta 168 0.01 0.016 (125/126)

By.03, Nearsite.

0.017 (14/14) 0.016 (42/42) 0 b

3 (pCi/m )

(O m 024)

East,3.8 mi @ 85 (O m 021)

(O m 021)

Gamma Spec.

12 Cs-134 0.5

<LLD

<LLD 0

Cs-137 0.6

<LLD

<LLD 0

Airborne lodme I-131 168 0.07

<LLD

<LLD 0

3 (pCi/m )

m Gamma Background Gamma Dose 90 3

16.0 (84/84)

BY-105c 17.7 (2/2) 14.1 (6/6) 0 o

(TLDs) (mR/Qtr.)

(11.2-17.7) 1.3 mi @ 84*

(13.5-14 8)

Milk I-131 25 1

<LLD

<LLD 0

(pCi/L)

Gamma Spec.

25 Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Ba-La-140 15

<LLD

<LLD 0

Other Gammas 20

<LLD

<LLD 0

Surface Water Gamma Spec.

12 (pCi/L)

Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Other Gammas 15

<LLD sLLD 0

Tritium 4

200 915 (1/1)

BY-12, Oregon Pool 915 (1/1)

<LLD 0

of Rock River, Downstream,45 mi l

@ 213*

  • Mean and range based on detectable measurements only. Fractions indicated in parentheses.

b 3

locations BY-03, BY-05, and BY-21 had identical means of 0.017 pCi/m Only BY-03 is detailed in this summary.

c locations EY-105, BY-215 and BY-216 had identical means of 17.7 mR. Only BY-105 is detailed in this summary.

E M

m E

M M

M M

M M

W-TABLE 5.0-4 (continued)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM QUARTERLY

SUMMARY

Name of Facility Byron Nuclear Power Station Docket No. %-4R 50-455 location of Facility Octe. Illinois _

Reportmg Permd 2nd Ouarter 1994 (County, State)

Sample Type and Indicator location with Highest Control Number of Type Number of locations Ouarterly Mean Locations Non-routine (Uruts)

Analyses LLD Mean*

Mean Results a

Range Mean Range Imation Range Well Water Gross Beta 6

4

<LLD None 0

(pCi/L)

Gamma Spec.

6 Cs-134 15

<LLD None O

Cs-137 18

<LLD None 0

Other Gammas 15

<LLD None 0

un Tritium 6

200

<LLD None 0

Bottom Sediments Gamma Spec.

3 (pCi/g dry)

Cs-134 0.15

<LLD

<LLD 0

Cs-137 0.18

<LLD

<LLD 0

Other Gammas 0.20

<LLD

<LLD 0

Fish Gamma Spec.

18 (pCi/g wet)

Cs-134 0.13

<LLD

<LLD 0

Cs-137 0.15

<LLD

<LLD 0

Other Gammas 0 13

<LLD

<LLD 0

  • Mean and range based on detectable measurements only. Fractions indicated in parentheses.

TABLE 5.0-5 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM QUARTERLY

SUMMARY

Name of Fachty Byron Noctne Power station Docket No. So-4R 50-455 locaten of Facihty Oele IUinois Reportmg Period 3rdouarter 1994 (County, State)

Sample Type and Indicator Location with Highest Control Number of Type Number of Incations Ouarterly Mean I.ocations Non-routine (Units)

Analyses LLD Mean*

Mean Nts a

Range Mean Range Location Range Air Partiastates Gross Beta 156 0.01 0.019 (117/117)

BY-06, Oregon,4.6 0.021 (13/13) 0.019 (39/39) 0 3

(pCi/m )

(0.016-0.037) mi O 213' (0.014 4 033)

(0.011 0.034)

Gamma Spec.

12 Cs-134 0.05

<LLD

<LLD 0

Cs-137 0.06

<LLD

<LLD 0

Airborne lodine I-131 156 0.07

<LLD

<LLD 0

3 (pCi/m )

IS

Background

Gamma Dose 88 3

15.2 (82/82)

BY-212, 17.1 (2/2) 12.9 (6/6) 0 (ll.Ds) (mR/Qtr.)

(10.9-17.1) 4.9 mi @ 357' (12.5-13.4)

Milk I-131 30 1

<LLD (pCi/L)

<LLD 0

Gamma Spec.

30 Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Ba-La-140 15

<LLD

<LLD 0

Other Gammas 20

<LLD

<LLD 0

Surface Water Gamma Spec.

12 (pCi/L)

Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Other Gammas 15

<LLD

<LLD 0

Tritium 4

200 473 (1/1)

BY-12, Oregon Pool 473 (1/1)

<LLD 0

of Rock River,4.5 mi e 21f

  • Mean and range based on detectable measurements only. Fractions indicated in parentheses, m

m M

M M

M M

E n

M M

M M

M M

M TABLE 5.0-5 (continued)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM QUARlIRLY

SUMMARY

Name of Facthty Byron Nuclear Power station Docket No. 50-4R 50455 Locatxm af Fachty Ocle. Illinois heporting Pwiod 3rd Ouarter 1994 (County, State)

Sample Type and Indicator Location with Highest Control Number of Type Number et Locations Ouarterly Mean Locatums Non-routine (Umts)

Analyses LLD Mean*

Mean Results a

Range Mean Range I.ocation Range Well Water Gmss Beta 6

4

<LLD None 0

(pCi/L)

Gamma Spec.

6 Cs-134 15

<LLD None O

Cs-137 18

<LLD None 0

Other Gammas 15

<LLD None O

tn W

Tritium 6

200

<LLD None O

Vegetation Gamma Spec.

15 (pCi/g wet)

Cs 134 0.06

<LLD

<LLD 0

C5-137 0.08

<LLD

<LLD 0

Other Gammas 0.08

<LLD

<LLD 0

I-131 2

0.06

<LLD

<LLD 0

F3h G. mma Spec.

24 (pCi/g wet)

Cs-134 0.13

<LLD

<tLD 0

Cs-137 0.15

<LLD

<tLD 0

Other Gammas 0.13

<LLD

<LLD 0

' Mean and range based on detectable measurements only. Fractions indicated in parentheses.

TABLE 5.0-6 RADIOLOGICAL ENVIRONMENTAL MONTIORING PROGRAM QUARTERLY

SUMMARY

Nameof Facthey Byron Nuclear Power staten Daket No. 50-4M. SM55 Incation of Faolity Orle Illinnis Reporting Period 4thouarter 1994 (County, State)

Sample Type and Indicator Location with Highest Control Number of Type Number of locations Ouarterly Mean locatens Non-routme (Units)

Analyws LLD Mea n' Mean Results a

Range Mean Range location Range Air Particulates Cross Beta 156 0.01 0.024 (117/117)

BY4T2,St;Ilman 0.026 (13/13) 0 026 (39/39) 0 b

3 (pCi/m )

(0.012-0.051)

Valley,6.2 mi @ 56' (0.014-0.050)

(0.010-0.052)

Gamma Spec.

12 Cs-134 0.05

<LLD

<LLD 0

Cs-137 0.%

<LLD

<LLD 0

Airborne lodme I-131 1%

0.07

<LLD

<LLD 0

3 (pCi/m )

Gamma Backgroumi Gamma Dose 84 3

18.4 (78/78)

BY-105,

20.8 (2/2) 16.9 (6/6) 0 C

da (TLDs)(mR/Qtr.)

(14.2-20.8) 13mi @ M.

(16.5-17.8)

Milk 1-131 20 1

<LLD

<I '. D 0

(pCi/L)

Gamma Spec.

20 Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

Ba-La-140 15

<LLD

<LLD 0

Other Gammas 20

<LLD

<LLD 0

Surface Water Gamma Spec.

12 Cs-134 15

<LLD

<LLD 0

Cs-137 18

<LLD

<LLD 0

(

Other Gammas 15

<LLD

<LLD 0

(

Tritium 200 574 (1/1)

BY-12. Oregon Pool 574 (1/1)

<LLD 0

4 of Rock River,45 mi 9 213"

  • Mean and range baW on detectable measurements only. Fractions indicated in parentheses.

b locations BY-02 and BY-08 had identical means of 0.026pCi/m. Only BY-02 is detailed in this summary.

3

m c-m r,

c, r-m, r,

c m,

m, r

m TABLE 5.0-6 (continued)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM QUARTERLY

SUMMARY

Name of Facihty Byron Nuclear Power Station Docket No. 50-454. 5M55 locatkm of Faolity Ocle Illinois Reportmg Pened 4th Ouarter 1m4 (County, State)

Sample Type and Indicator Location with thghest Control Number of Type Number of Locations Oua rterly Mean locations Non-routme (Umts)

Analyses LLD Mean" Mean Results a

Range Mean Range Location Range Well Water Gross Deta 6

4

<LLD None 0

(pCi/L)

Gamma Spec.

6 Cs-134 15

<tLD None O

Cs-137 18

<LLD None 0

Other Gammas 15

<tLD Nane 0

m Tntium 6

200

<tLD None 0

vi 1

Bottom Sediments Gamma Spec.

3 (pCi/g dry)

Cs-134 0.15

<LLD

<tLD 0

Cs-137 0.18

<LLD

<LLD 0

Other Gammas 0.20

<LLD

<LLD 0

nsh Gamma Spec.

21 (pCi/g wet)

Cs-134 0.13 (LLD

<LLD 0

Cs-137 0.15

<LLD

<LLD 0

Other Gammas 0.13

<LLD

<LLD 0

  • Mean and range based on detectable measumnene only. Fractions indicated in parentheses.

l

l lI i

lI i

i.

APPENDIX II l

METEOROLOGICAL DATA 1

iI l!I

,1 I

I I

I I

56 I

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET

[

WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O 1

0 1

SSE O

O O

O O

O O

S O

O O

O O

O O

SSW 0

0 0

0 1

0 1

SW 0

0 0

4 3

0 7

{

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

2 0

0 2

NW 0

1 0

2 4

1 8

NNW 0

1 0

3 0

0 4

VARIABLE O

O O

O O

O O

TOTAL 0

2 0

11 9

1 23 Hours of calm in this stability class:

0

{Hoursofmissingwindmeasurementsinthisstabilityclass:

0 Hours of missing stability measurements in all stability classes:

0 57

O O

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O 1

1 0

0 0

2 i

NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

)

E O

O 1

0 0

0 1

5 ESE O

O 1

0 0

1 2

as SE O

O O

O O

3 3

SSE O

O O

O O

O O

S O

O O

O O

O O

SSW 0

0 0

1 0

0 1

1 SW 0

0 0

2 1

0 3

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 4

0 4

NW 0

0 2

1 3

0 6

NNW 0

0 2

1 1

0 4

VARIABLE O

O O

O O

O O

TOTAL 0

1 7

5 9

4 26 Hours of calm in this stability class:

0 Hours of missing wind measurement s in this stability class:

0 Hours of missing stability measurements in all stability classes:

0 l

58 E.

i BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

!3 WIND

, E DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O 3

3 0

0 0

6 NNE O

1 2

0 0

0 3

l NE O

O O

O O

O O

ENE O

O 1

0 0

0 1

E O

O O

O O

O O

ESE O

O 1

0 0

0 1

SE O

O O

4 2

2 8

SSE O

O 2

4 0

0 6

S O

O 2

1 0

0 3

SSW 0

0 1

0 0

2 SW 0

0 0

2 1

0 3

WSW 0

0 0

1 0

0 1

W 0

0 0

0 0

0 0

WNW 0

0 5

6 2

3 16 I

i NW 0

1 4

4 4

1 14 1

NNW 0

1 3

6 3

0 13 l

VARIABLE O

O O

O O

O O

I TOTAL 0

6 24 29 12 6

77 IHours of calm in this stability class:

0

, Hours of missing wind measurements in this stability class:

0 Hours of missing stability measurements in all stability classes:

0

.I 59

E O

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 STABILITY CLASS - NEUTRAL (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

1 13 26 35 13 0

88 NNE 1

7 20 34 2

0 64 NE 1

10 13 10 14 13 61 ENE O

14 19 11 25 6

75 E

O 15 33 25 16 3

92 ESE O

2 17 8

7 7

41 SE 1

1 12 21 11 3

49 SSE O

2 14 30 6

15 67 S

0 0

14 3

7 0

24 SSW 1

2 7

5 11 3

29 SW 1

7 4

22 18 0

52 WSW 0

8 15 43 8

2 76 W

D 7

32 57 20 11 127 WNW 1

4 27 67 31 1

131 NW 0

9 31 48 16 1

105 NNW 0

11 33 37 7

4 92 VARIABLE O

O O

O O

O O

TOTAL 7

112 317 456 212 69 1173 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

2 Hours of missing stability measurements in all stability classes:

0 s

1 BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 l

STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 250-30 FT)

{

WINDS MEASURED AT 250 FEET WIND SPEED (in mph) l lg WIND

!g DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O 1

15 11 1

0 28 i

NNE O

3 6

3 0

0 12 NE O

5 10 5

0 0

20 l

ENE O

5 5

3 0

0 13 l

s j

E 1

5 6

6 1

0 19 ESE O

O 2

3 8

4 17 SE O

O 6

9 11 0

26 SSE O

1 6

16 5

11 39 S

O 3

7 15 19 16 60 SSW 0

0 4

11 32 7

54 SW 0

5 5

14 7

2 33 WSW 1

1 17 34 11 0

64 W

0 1

25 34 8

0 68 WNW 0

2 37 32 11 0

82 NW 0

2 32 37 1

0 72 NNW 0

6 10 19 2

0 37 VARIABLE O

O O

O O

O O

l TOTAL 2

40 193 252 117 40 644 l

- Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability c1nss:

2 Hours of missing stability measurements in all stability classes:

0 l

61 1

a

O o!

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O O

2 0

0 0

5 NNE O

O O

O O

O O

NE 1

2 1

0 0

0 4

ENE O

3 0

0 0

0 3

E O

O O

1 0

0 1

ESE 1

0 1

2 1

0 5

SE O

1 2

2 3

1 9

SSE 1

0 5

4 4

2 16 S

1 3

1 3

11 9

28 SSW 0

0 3

6 6

0 15 SW 0

0 0

3 1

0 4

WSW 1

1 1

7 0

0 10 W

1 0

1 6

1 0

9 WNW 0

4 8

7 1

0 20 NW 1

0 5

2 0

0 8

NNW 1

1 2

1 0

0 5

VARIABLE O

O O

O O

O O

I TOTAL 8

18 32 44 28 12 142 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

0 Hours of missin9 stability measurements in all stability classes:

0 62 g

=

L BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JANUARY-MARCH 1994 STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 250-30 FT) 2 WINDS MEASURED AT 250 FEET

{-

WIND SPEED (in mph) 4 WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O 2

1 0

0 0

3 NNE O

O O

O O

O O

NE O

3 3

0 0

0 6

EL ENE O

10 4

0 0

0 14 E

O 6

0 0

0 0

6 ESE 1

0 1

2 2

0 6

{

SE O

O 1

3 2

0 6

SSE O

1 0

1 1

0 3

S 1

0 0

0 2

0 3

SSW 0

0 0

0 1

0 1

SW 1

1 4

1 2

0 9

I WSW 0

0 0

2 0

0 2

L W

0 0

0 1

0 0

1 WNW 0

0 3

4 0

0 7

NW 0

0 1

1 0

0 2

NNW 0

0 2

0 0

0 2

~

VARIABLE O

O O

O O

O O

TOTAL 3

23 20 15 10 0

71 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

0 Hours of missing.itabilit y measurement s in all stability classes:

0

[

63 d

E O

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O O

15 4

2 0

21 NNE O

1 12 12 3

0 28 NE O

3 7

7 0

0 17 ENE O

2 6

4 5

0 17 E

O 2

9 0

0 0

11 ESE O

2 1

1 0

0 4

SE O

1 1

1 0

0 3

SSE O

3 3

5 1

0 12 S

O 5

0 0

4 3

12 SSW O

1 2

9 13 0

25 SW O

9 8

7 4

0 28 WSW 0

6 6

3 13 2

30 W

0 2

8 2

1 0

13 WNW 0

1 7

5 10 1

24 NW O

3 4

17 8

1 33 NNW 0

1 8

3 0

0 12 VARIABLE O

O O

O O

O O

TOTAL 0

42 97 80 64 7

290 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

0 Hours of missing stability measurements in all stability classes:

0 64 E=

l BYRON NUCLEAR POWER STATION PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND I

DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL l

l N

O 2

4 2

1 0

9 l

NNE O

1 4

4 1

0 10 NE O

O 1

0 0

0 1

l ENE O

1 0

1 0

0 2

i l

l E

O 1

7 1

0 0

9 ESE O

2 1

0 0

0 3

l SE O

9 3

1 0

0 4

SSE O

O 4

1 1

0 6

l l

S O

1 0

2 3

0 6

I SSW O

3 2

3 2

1 11 SW 0

5 3

3 1

0 12 l

WSW O

O 3

2 2

0 7

W 1

1 1

6 2

0 11 WNW 1

1 5

3 2

2 14 NW O

3 2

4 1

1 11 NNW 0

5 4

2 0

0 11 VARI ABi.E O

O O

O O

O O

I TOTAL 2

26 44 35 16 4

127 Hours of calm in this stability class:

0 Hours of missing vrind measurements in this stability class:

0 IHours of missing stability measurements in all stability classes:

0 I

65 L -

i 0i U

i BYRON NUCLEAR POWER STATION

{

PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O 3

3 2

0 0

8 NNE O

O 2

3 5

0 10 NE O

1 2

1 0

0 4

ENE O

O 2

1 0

0 3

E O

3 5

5 0

0 13 E'

ESE O

1 1

0 0

0 2

gg SE O

1 2

0 0

0 3

SSE O

1 4

1 1

1 8

S 1

3 2

0 2

0 8

SSW 1

9 2

4 3

2 21 SW 0

2 3

5 2

0 12 WSW 0

2 3

1 2

1 9

W 0

4 3

3 3

0 13 WNW 0

3 7

4 3

1 18 NW 0

2 1

2 3

0 8

NNW 1

1 3

1 0

0 6

VARIABLE O

O O

O O

O O

TOTAL 3

36 45 33 24 5

146 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

0 Hours of missing stability measurements in all stability classes:

0 66

I BYRON NUCLEAR POWER STATION PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - NEUTRAL (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION O.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

2 4

14 16 20 0

56 NNE O

5 6

7 20 8

46 NE 1

1 5

11 15 5

38 ENE O

2 7

18 16 6

49 E

O 4

19 15 18 2

58 ESE 1

3 6

6 4

0 20 SE 3

4 1

8 8

0 24 SSE 1

4 3

7 7

5 27 S

3 4

8 11 7

4 3 ', '

SSW 2

9 6

27 17 8

69 SW 3

6 12 7

16 9

53 WSW 2

3 19 9

13 16 62 W

0 3

15 10 17 11 56 WNW 0

3 10 10 6

10 39 NW 1

5 6

18 6

3 39

~

NNW O

1 12 21 6

0 40

_~

VARIABLE O

O O

O O

O O

TOTAL 19 61 149 201 196 87 713 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

1 Hours of missing stability measurements in all stability classes:

0 6

67

E C

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O 2

6 14 3

0 25 1

NNE O

2 3

17 2

0 24 NE 1

3 9

12 3

0 28 ENE O

4 5

17 6

0 32 E

3 2

19 15 4

0 43 ESE 2

1 2

11 8

2 26 SE O

5 3

9 9

5 31 SSE O

1 4

6 10 4

25 S

O 3

6 14 14 3

40 SSW 1

1 3

31 35 5

76 SW 1

2 12 27 5

10 57 WSW 2

1 9

16 5

0 33 W

1 4

13 16 5

7 46 WNW 0

5 16 7

4 0

32 NW 0

1 12 11 4

0 28 NNW 0

5 5

10 2

0 22 VARIABLE O

O O

O O

O O

TOTAL 11 42 127 233 119 36 568 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability class:

9 j

Hours of missing stability measurements in all stability classes:

0 l

I 68 l-

I BYROM NUCLEAR POWER STATION PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

I WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

2 6

4 1

0 0

13 NNE O

1 4

1 0

0 6

NE O

O O

2 0

0 2

ENE O

1 0

6 1

0 8

E 2

2 4

3 1

0 12 ESE 1

1 5

7 11 1

26 SE O

O 2

12 4

0 18 SSE 1

0 3

4 5

2 15 S

O 3

5 13 13 0

34 SSW 1

6 2

10 6

0 25 SW 2

3 6

11 1

0 23 WSW 1

0 5

3 2

0 11 W

0 1

4 8

1 0

14 WNW 0

0 6

5 0

0 11 NW 0

1 2

9 0

0 12 NNW 0

1 5

6 1

0 13 VARIABLE O

O O

O O

O O

I TOTAL 10 26 57 101 46 3

243 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability clase:

1 Hours of missing stability measurements in all stability classes:

0 I

69

00 BYRON NUCLEAR POWER STATION PERIOD OF RECORD: APRIL-JUNE 1994 STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

1 0

3 1

0 0

5 NNE O

1 1

0 0

0 2

i NE O

O O

O O

O O

ENE O

O 1

0 0

0 1

E O

O O

O O

O O

ESE O

O O

2 0

0 2

l l

SE O

O 3

6 0

0 9

SSE O

O 3

6 1

2 12 S

1 1

4 8

0 1

15 SSW 0

3 1

3 1

0 8

SW 0

3 1

3 1

0 8

1 WSW 1

2 1

3 0

0 7

W 1

1 3

0 0

0 5

WNW 1

3 0

0 0

0 4

)

NW 0

1 0

1 0

0 2

NNW 1

2 1

1 0

0 5

l l

VARIABLE O

O O

O O

O O

TOTAL 6

17 22 34 3

3 85 Hours of calm in this stability class:

0

}

Hours of missing wind measurements in this stability class:

1 j

Hours of missing stability measurements in all stability classes:

0 70 E-

1 BYRON NUCLEAR POWER SYATION PERIOD OF RECORD: JULY-SEF TEMBER 1994 f-STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 250-30 FT)

WINDS MEASURED AT 250 FEET

{. -

WIND SPEED (in mph)

DIRECTION O.8-3 4-7 8-12 13-18 19-24

> 24 TOTAL N

O O

2 2

0 0

4 f

NNE O

1 0

0 0

0 1

NE O

O 1

0 0

0 1

ENE O

O 1

2 0

0 3

E O

2 6

1 0

0 9

ESE O

1 0

0 0

0 1

SE O

1 1

0 0

0 2

SSE O

O 9

4 0

0 13 S

O O

4 8

1 0

13 SSW 0

0 6

11 0

0 17 SW 0

1 5

5 0

0 11

('

WSW 0

2 3

1 0

0 6

W 0

3 3

2 0

0 8

WNW 0

4 6

6 0

0 16 NW 0

2 5

13 1

0 21 g

[

NNW 0

0 3

5 0-0 8

{

VARIABLE O

O O

O O

O O

TOTAL 0

17 55 60 2

0 134 ours of calm in this stability class:

0 ours of missing wind measurements in this stability class:

0 ouro of missing stability measurements in all stability classes:

0 m

71 1

C2 Oi BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JULY-SEPTEMBER 1994 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 250-30 FT) g!

WINDS MEASURED AT 250 FEET WIND SPEED (in mph)

WIND 910_ggN g8;} 4;} 8-}2 }3;}8 }9;24 > 24 }g}AL E N O O 3 4 0 0 7 NNE O 1 3 1 0 0 5 NE O 1 1 0 0 0 2 ENE O O 1 1 0 0 2 E O O 3 1 0 0 4 ESE O O O O O O O SE 1 2 1 0 0 0 4 SSE O 5 4 2 0 0 11 S 1 1 12 5 1 0 20 SSW 0 2 5 2 2 0 11 SW 0 2 10 5 0 0 17 WSW 0 1 5 5 2 0 13 W 1 5 11 4 0 0 21 WNW 0 2 2 5 0 0 9 NW 1 4 6 7 0 0 18 NNW 0 1 2 2 0 0 5 VARIABLE O O O O O O O I TOTAL 4 27 69 44 5 0 149 I' Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0 l 72 El ' \\

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JULY-SEPTEMBER 1994 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET WIND SPEED (in mph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N O 1 5 2 0 0 8 NNE O 2 1 0 0 0 3 NE O 2 0 0 0 0 2 ENE O 1 0 1 0 0 2 E O 4 6 0 0 0 10 ESE O O 1 1 0 0 2 SE O O 2 0 1 0 3 SSE O 3 0 4 1 0 8 S O 4 8 5 1 0 18 SSW O 5 5 3 2 0 15 SW 0 3 11 4 1 0 19 WSW 0 3 6 1 1 0 11 W O 2 1 6 0 1 10 WNW 1 3 6 5 0 0 15 NW 1 5 4 7 0 0 17 NNW 1 1 4 1 0 0 7 VARIABLE O O O O O O O I TOTAL 3 39 60 40 7 1 150 l Hours of calm in this stability class: 0 I Hours of missin9 wind measurements in this stability class: O l Hours of missing stability measurements in all stability classes: 0 73 I

E oi BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JULY-SEPTEMBER 1994 STABILITY CLASS - NEUTRAL (DIFF TEMP 250-30 FT) g, WINDS MEASURED AT 250 FEET g) WIND SPEED (in mph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL i N 2 5 13 8 1 0 29 NNE 2 5 10 11 2 0 30 NE O 6 3 4 0 1 14 ENE 4 4 12 5 1 0 26 E 1 7 17 4 0 0 29 ESE O 3 7 6 1 0 17 SE O 5 3 18 12 0 38 SSE 2 5 16 24 10 1 58 S 2 15 19 18 4 1 59 SSW 1 11 30 18 7 0 67 SW 0 17 18 26 7 0 68 WSW 4 11 9 23 5 0 52 W 3 17 20 18 2 0 60 WNW 3 4 16 16 1 0 40 NW 3 7 36 14 3 0 63 NNW 3 9 18 7 0 1 38 VARIABLE O O O O O O O TOTAL 30 131 247 220 56 4 688 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0 74 I

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JULY-SEPTEMBER 1994 ( STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET { WIND SPEED (in mph) WIND DIRECTION O.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N 1 1 10 11 0 0 23 [ NNE 1 2 1 6 2 0 12 NE 1 2 4 6 0 0 13 ENE 2 3 11 9 4 0 29 E 3 15 12 6 1 0 37 ESE 2 5 6 3 2 0 18 SE 1 2 7 7 11 0 28 SSE 2 4 12 13 11 1 43 S 1 2 12 30 20 6 71 SSW O 6 10 34 18 2 70 SW 3 3 25 35 16 3 85 { WSW 0 3 13 10 1 0 27 W 0 3 8 8 1 0 20 WNW 0 1 12 9 0 0 22 NW 0 2 23 12 0 0 37 NNW 1 4 19 11 0 0 35 VARIABLE O O O O O O O TOTAL 18 58 185 210 87 12 570 Hours of calm in this stability class: 0 EHoursofmissingwindmeasurementsinthisstabilityclass: 4 Hours of missing stability measurements in all stability classes: 0 { 75

Ea BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JULY-SEPTEMBER 1994 STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 250-30 FT) g WINDS MEASURED AT 250 FEET g WIND EDEED (in mph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N 1 3 8 1 0 0 13 NNE O 3 6 4 0 0 13 NE O 3 1 0 0 0 4 ENE O O 1 1 0 0 2 E O 2 4 2 0 0 8 ESE 2 0 3 1 6 0 12 SE 1 0 3 9 8 0 21 SSE O O 6 15 31 1 53 S O 2 6 26 17 1 52 SSW 0 2 4 25 12 0 43 SW O O 6 16 4 0 26 WSW 2 1 8 7 0 1 19 W O 3 6 2 0 0 11 WNW 2 0 12 1 0 0 15 NW 1 1 14 11 0 0 27 NNW 2 1 19 13 0 0 35 VARIABLE O O O O O O O TOTAL 11 21 107 134 78 3 354 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 2 Hours of missing stability measurements in all stability classes: 0 76 11

I j BYRON NUCLEAR POWER STATION PERIOD OF RECORD: JULY-SEPTEMBER 1994 l STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET l WIND SPEED (in mph) 's WIND E DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N O 1 1 0 0 0 2 l NNE 2 1 2 0 0 0 5 NE 1 1 0 0 0 0 2 ENE 2 1 0 0 0 0 3 E 2 0 0 0 0 0 2 ESE 1 0 0 1 0 0 2 SE 1 2 0 4 1 0 8 SSE O 1 4 12 4 0 21 S 0 0 8 14 7 0 29 SSW 1 1 1 11 0 0 14 SW 0 3 4 10 0 0 17 { WSW O O 4 3 0 0 7 W 2 1 3 0 0 0 6 WNW 1 3 1 1 0 0 6 NW 0 2 6 3 0 0 11 ^ NNW 1 2 10 9 0 0 22 ~ VARIABLE O O O O O O O TOTAL 14 19 44 68 12 0 157 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurement s in all stability classes: 0 77

0o BYRON NUCLEAR POWER STATION PERIOD OF RECORD: OCTOBER-DECEMBER 1994 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 250-30 FT) g WINDS MEASURED AT 250 FEET g WIND SPEED (in mph) WIND DIRECTION 0,8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N O O 1 0 0 0 1 NNE O 2 1 0 0 0 3 NE O O O O O O O ENE O 2 0 1 0 0 3 E O 1 9 9 0 0 19 ESE O O 8 3 0 0 11 SE O O 2 0 0 0 2 SSE O O 5 5 4 0 14 S 0 0 1 2 1 3 7 SSW 0 0 2 6 0 0 8 SW 0 2 0 0 0 0 2 WSW 0 0 1 2 2 0 5 W 0 0 0 4 7 0 11 WNW O O 2 5 3 0 10 NW O O 3 5 2 0 10 NNW O O O 1 0 0 1 VARIABLE O O O O O O O I TOTAL 0 7 35 43 19 3 107 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: O Hours of missing stability measurement s in all stability classes: 0 i 78 E =

BYRON NUCLEAR POWER STATION PERIOD OF RECORD: OCTOBER-DECEMBER 1994 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET { WIND SPEED (in mph) DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N O O 1 0 0 0 1 NNE O 2 1 0 0 0 3 NE O 2 0 0 0 0 2 ENE O 1 0 0 0 0 1 E O 4 1 2 0 0 7 ESE O O 1 1 0 0 2 SE O O 1 0 0 0 1 SSE O O 1 4 1 0 6 S O O O 2 1 0 3 SSW 0 0 1 2 0 1 4 SW 0 1 1 1 0 0 3 { WSW 0 1 0 0 2 0 3 W 0 0 0 2 0 0 2 WNW O O O 1 3 0 4 NW 0 0 0 1 0 0 1 NNW 0 0 0 0 0 0 0 VARIABLE O O O O O O O TOTAL 0 11 8 16 7 1 43 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 l Hours of missing stability measurements in all stability classes: 0 ( 79 __-----.m- ^ ' ' ' - ' ' ~ ~ '

Ea BYRON NUCLEAR POWER STATION PERIOD OF RECORD: OCTOBER-DECEMBER 1994 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 250-30 FT) i WINDS MEASURED AT 250 FEET WIND SPEED (in mph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL l N O O 1 0 0 0 1 NNE O O 2 0 0 0 2 l NE O 2 0 0 1 0 3 ENE O O O O O O O E O 1 2 2 0 0 5 ESE O O O 2 0 0 2 SE O O O O O O O SSE O O 1 0 2 0 3 S 0 0 1 0 1 1 3 SSW 0 0 3 0 0 0 3 SW 0 1 3 1 0 0 5 WSW 0 1 0 2 2 4 9 W 0 0 0 2 1 0 3 WNW 0 0 4 4 0 0 8 NW 0 1 0 2 0 0 3 NNW 0 0 0 1 0 0 1 VARIABLE O O O O O O O TOTAL 0 6 17 16 7 5 51 l Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 I Hours of missing st abilit y measurement s in all stability classes: 0 l I I

.I BYRON NUCLEAR POWER STATION PERIOD OF RECOF.D: OCTOBER-DECEMBER 1994 STABILITY CLASS - NEUTRAL (DIFF TEMP 250-30 FT) WINDS MEASUREP AT 250 FEET WIND SPEED (in eph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N 3 8 22 26 6 0 65 NNE 1 5 19 6 9 7 47 NE 1 4 6 8 14 4 37 ENE 2 4 8 28 5 0 47 E 1 6 12 19 3 1 42 ESE 1 0 5 13 3 6 28 SE O 2 7 5 2 0 16 SSE O 7 18 25 13 11 74 S 1 9 14 27 27 13 91 SSW 2 8 28 24 12 13 87 SW 3 6 14 15 8 5 51 WSW 1 4 9 11 6 25 56 W 2 8 10 33 9 10 72 WNW 2 11 19 22 19 0 73 NW 4 11 22 27 6 0 70 NNW 1 6 33 31 2 1 74 VARIABLE O O O O O O O I TOTAL 25 99 246 320 144 9G 930 Mours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 H lI ours of missin9 stability measurements in all stability classes: 0 I 81 I

00 BYRON NUCLEAR POWER STATION PERIOD OF RECORD: OCTOBER-DECEMBER 1994 STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET WIND SPEED (in mph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N 2 7 9 3 1 0 22 NNE 1 5 9 5 6 0 26 NE 2 5 9 11 4 0 31 ENE 1 6 9 11 15 1 43 E O 3 14 21 5 0 43 ESE 1 1 9 11 15 5 42 SE O 2 9 18 11 4 44 SSE 2 3 1 13 34 19 72 S O 2 6 19 38 3 68 SSW 1 3 10 18 45 16 93 SW 3 0 10 9 13 7 42 WSW 1 3 8 11 14 0 37 W 0 9 12 42 5 0 68 WNW i 2 9 20 0 0 32 m1ll' NW 1 1 12 13 2 0 29 NNW 0 5 4 16 0 0 25 VARIABLE O O O O O O O I TOTAL 16 57 140 241 208 55 717 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: O 82 B! =:

i {' BYRON NUCLEAR POWER STATION PERIOD OF RECORD: OCTOBER-DECEMBER 1994 STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET ( WIND SPEED (in mph) DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N O O 1 5 0 0 6 NNE O O 2 4 1 0 7 NE 1 1 2 5 0 0 9 ENE 1 1 1 1 1 0 5 { E O 3 9 4 1 0 17 ESE O O 2 6 5 0 13 h SE O 1 4 13 8 3 29 SSE O O 1 13 13 0 27 S O O 3 9 15 2 29 SSW 0 0 1 7 9 0 17 SW O O 2 5 0 0 7 ( WSW 0 1 1 5 0 0 7 W O 2 1 4 0 0 7 WNW 0 1 9 1 0 0 11 NW 0 0 4 5 0 0 9 NNW 1 2 5 6 0 0' 14 VARIABLE O O O O O O O TOTAL 3 12 48 93 53 5 214 { Hours of calm in this stability class: 0 (Houro of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0 83

i EI = l BYRON NUCLEAR POWER STATION PERIOD OF RECORD: OCTOBER-DECEMBER 1994 STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 250-30 FT) WINDS MEASURED AT 250 FEET WIND SPEED (in mph) WIND DIRECTION 0.8-3 4-7 8-12 13-18 19-24 > 24 TOTAL N 1 1 1 4 0 0 7 NNE O O O 2 0 0 2 NE 2 3 2 2 0 0 9 ENE 1 4 0 1 0 0 6 E O 6 3 3 1 0 13 ESE O O O O 10 2 12 SE O O 1 8 7 1 17 SSE O O 2 8 4 0 14 S O O 2 6 1 0 9 SSW 0 1 2 8 2 0 13 SW 0 0 2 4 0 0 6 WSW 0 1 3 0 0 0 4 W 0 0 5 5 0 0 10 WNW 0 1 3 0 0 0 4 ggr NW 0 2 4 13 0 0 19 i NNW O O O 1 0 0 1 VARIABLE O O O O O O O TOTAL 4 19 30 65 25 3 146 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing st abilit y measurement s in all stability classes: 0 84 I

l 4 \\ 4 .i k i i i f i l 4 i I 1 1 'E iE APPENDIX III 1 1994 REMP SAMPLE RESULTS i fl l i i i II !I i .I e i i 's 4 4 i i 85 i

BYRON TABLE OF CONTENTS i l Section g List of Tables .87 j

1.0 INTRODUCTION

... 8 8 2.0 LISTING OF MISSED SAMPLES.... .89 3.0 LISTING OF SAMPLE ANOMALIES........ .90 4.0 TLD DATA...... .159 3 5.0 GRAPHS OF DATA TRENDS......... ..162 1 i I i i l l 3 I i 1 l I I 86 i

I BYRON I LIST OF TABLES S 11112 Pace 1 Airborne Particulates and Iodine-131. .91 2 Airborne Particulates, Quarterly Composites of Weekly Collections.. .103 3 Milk.. .109 4 Fish, Edible Portions... .124 5 Bottom Sediments.. .136 6 Vegetables. .138 7 Surface Water.. .141 8 Well Water.. .150 Milch Animals, Nearest Residence, and Nearest Livestock Census....... .154 I I 1 87

I BYRON \\

1.0 INTRODUCTION

The following constitutes the final,1994 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at Byron Station, Byron, Illinois. Results of completed analyses are presented in the attached tables. Data obtained in the program are well within the ranges previously encountered in the program and to be expected in the environmental media sampled. For all gamma isotopic analyses, spectrum is computer scanned from 80 to 2048 kev. Specifically included are Mn-54, Fe-59, Co-58, Co-60, Zn-65, Zr-95, Nb-95, Ru-103, Ru-106, I-131, Ba-La-140, Cs-134, Cs-137, Ce-141, and Ce-144. Naturally occurring gamma-emitters, such as K-40 and Ra daughters, are frequently detected but not listed here. The data is reported in the format of xi2s;2TPU, where "x" is the significant result, "s" is the one standard deviation counting uncertainty, and TPU is the total propagated uncertainty at the one sigma confidence level. I All concentrations, except for gross beta, are decay corrected to the date of collection. Deviations from Scheduled Sampling and Corrective Actions Taken All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples. Thusual Environmental Results Sample Date Type Location Collected Comments SS

BYRON 2.0 LISTING OF MISSED SAMPLES j Expectea Collection Sample Type Location Date Reason Surface Water BY-13 01-03-94 Rock River Frozeu. Surface Water BY-29 01-03-94 Rock River Frozen. Surface Water BY-09 01-10-94 Creek Frozen. F Surface Water BY-13 01-10-94 Rock River Frozen. L Surface Water BY-29 01-10-94 Rock River Frozen. AP/l BY-24 01-17-94 Inaccessible due to snowy conditions. ( Surface Water BY-09 01-17-94 Creek Frozen. Surface Water BY-13 01-17-94 Rock River Frozen. I Surface Water BY-29 01-17-94 Rock River Frozen. Surface Water BY-09 01-24-94 Creek Frozen. Surface Water BY-13 01-24-94 Rock River Frozen. Surface Water BY-29 01-24-94 Rock River Frozen. Surface Water BY-09 01-31-94 Creek Frozen. Surface Water BY-13 01-31-94 Rock River Frozen. Surface Water BY-29 01-31-94 Rock River Frozen. Surface Water BY-09 02-07-94 Creek Frozen. [ Surface Water BY-13 02-07-94 Rock River Frozen. Surface Water BY-29 02-07-94 Rock River Frozen. TLD BY-209-4 1st Qtr. Found missing 02-07-94 { TLD BY-211-4 1st Qtr. Found missing 02-07 94 Surface Water BY-09 02-13-94 Creek Frozen. Surface Water BY-13 02-13-94 Rock River Frozen. Surface Water BY-29 02-13-94 Rock River Frozen. h TLD BY-303-1 1st Qtr. Found missing 03-05-94; Replaced 03-06-94 TLD BY-216-2 2nd Qtr. Telephone pole replaced; TLD found missing 07-02-94; replaced 07-09-94. Surface Water BY-09 12-14-94 Creek Frozen. [ 89

BYRON ( 3.0 LISTING OF SAMPLE ANOMALIES t Collection l Sample Type Location Date Comments AP/I BY-01 01-17-94 Low volume; replaced pump. AP/I BY-01 02-13-94 Volume estimated; new timer { installed. AP/I BY-07 02-28-94 Volume estimated. AP/I BY-23 03-07-94 Volume estimated; new timer } installed. AP/I BY-24 04-23-94 Low volume. AP/I BY-21 04-30-94 Estimated teading. AP/I BY-01 04-30-94 Filterlight. AP/I BY-21 05-07-94 Estimated reading; replaced timer. AP/I BY-22 06-18-94 Low volume; no power. AP/I BY-22 06-25-94 Low volume; no power. AP/I BY-04 08-23-94 Filter light; sample damaged by heavy rain storm. AP/I BY-21 09-13-94 Low volume; pump out of service for 24 hours; installed new air sampler housing. AP/I BY-23 10-04-94 Pump found not running; installed new pump. AP/I BY-07 11-22-94 Volume estimated. AP/I BY-07 11-29-94 Volume estimated. AP/I BY-24 12-14-94 Volume estimated. AP/I BY-07 12-20-94 Volume estimated. I e i i

BYRON Table 1. Airborne Particulates and Iodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I 131 I Units: 10r2pCi/m' BY-01 Byron Date Volume Gross Date Volume Gross 3 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 01-03-94 284 2.5 i 0.3 ; 0.5 1.011.4;1.4 07-05-94 112 1.010.4;0.4 -1.312.6;2.6 I 01-10-94 297 2.810.4;0.6 -0.111.6;1.6 07-11-94 245 1.310.3;0.4 1.312.1;2.1 01-17-94 65 ^ 4.410.4;0.9 -0.9 i 5.6 ; 5.6 07-20-94 362 1.710.2;0.4 -0.610.8;0.8 01-24-94 285 3.3 i 0.4 ;0.7 0.0 i 0.6 ;0.6 07-26-94 245 1.9 i 0.3 ; 0.5 -0.211.2;1.2 I 01-31-94 277 2.210.3;0.5 -0.4 i 1.2 ; 1.2 08-02-94 292 2.1 i 0.3 ; 0.5 1.011.0;1.0 02-07-94 280 3.010.4;0.7 -0.1 1 1.2 ;1.2 08-09-94 290 1.310.2;0.3 -1.4 i 1.7 ; 1.7 b 02-13-94 256 2.7 i 0.4 ; 0.6 0.1 i 1.1 ; 1.1 06-16-94 290 1.5 i 0.2 ; 0.3 0.6 i 1.1 ; 1.1 02-21-94 315 2.2 i 0.3;0.5 -0.2 i 1.2 ; 1.2 08-23-94 273 1.9 i 0.3 ; 0.5 -0.111.0;1.0 02-28-94 290 2.310.3;0.5 0.6 i 1.2 ; 1.2 08-30-94 285 2.6 i 0.3 ; 0.6 -0.5 i 1.2 ; 1.2 03-07-94 285 2.210.3;0.5 -0.6 i 2.2 ;2.2 09-06-94 296 1.3 i 0.3 ; 0.4 -0.811.1;1.1 03-15-94 321 1.9 i 0.3 ;0.4 -0.811.1;1.1 09-13-94 289 3.010.2;0.6 0.3 i 1.0 ; 1.0 I 03-21-94 247 1.7 i 0.3 ; 0.4 -1.111.2;1.2 09-20-94 286 2.010.3;0.5 -1.0i 1.2 ; 1.2 03-28-94 284 1.3 i 0.3 ; 0.4 -0.5 i 1.1 ; 1.1 09-27-94 289 1.510.3;0.4 0.011.2;1.2 1st Qtr. Mean s.d. 2.5 i 0.8 -0.210.6 3rd Qtr. Mean s.d. 1.8 1 0.5 -0.21 0.8 04-04-94 293 2.010.3;0.5 0.2 i 1.1;1.1 10-04-94 286 1.2 i 0.3 ; 0.4 0.7 1.6; 1.6 04-11-94 291 1.810.3;0.4 1.310.8;0.8 10-11-94 287 1.7i 0.3 ; 0.4 0.S i 1.1 ; 1.1 04-16-94 197 0.910.3;0.3 1.011.6;1.6 10-18-94 284 2.410.3;0.5 0.01 1.0;1.0 04-23-94 280 1.610.3;0.4 -1.6 i 1.9; 1.9 10-25-94 282 2.510.3;0.5 -0.5 i 1.3 ; 1.3 04-30-94 279 < 0.4 0.811.2;1.2 11-01-94 297 1.510.3;0.4 -0.1 i 1.7; 1.7 05-07-94 294 1.5 i 0.3 ; 0.4 1.4 i 1.4 ; 1.4 11-08-94 285 1.6 i 0.3 ; 0.4 0.31 1.0;1.0 I 05-14-94 287 1.310.3;0.4 -0.4 i 1.5 ; 1.5 11-15-94 293 2.1 i 0.3 ; 0.5 -1.21 0.1;0.2 05-21-94 285 1.3 i 0.2 ; 0.3 0.4 i 1.3; 1.3 11-22-94 296 2.0 i 0.3 ; 0.5 0.61 3.2;3.2 05-28-94 285 1.7i 0.3 ; 0.4 -0.6 i 1.3; 1.3 11-29-94 286 1.710.3;0.4 0.41 0.9;0.9 06-04-94 279 1.610.3;0.4 -1.711.7;1.7 12-06-94 286 2.8 f 0.3 ; 0.6 0.31 1.0;1.0 06-11-94 266 1.510.3;0.4 -0.31 1.4;1.4 12-14-94 336 3.6 i 0.3 ; 0.7 0.1 i 0.8 ; 0.8 06-18-94 285 1.910.3;0.5 -0.4 i 1.2; 1.2 12-20-94 245 4.4 i 0.4 ; 0.9 0.111.2;1.2 06-25-94 281 2.010.3;0.5 0.011.2;1.2 12-27-94 272 3.110.3;0.6 -0.2 i 1.2 ; 1.2 I 07-02-94 292 1.8 f 0.3 ; 0.4 -1.011.3;1.3 2nd Qtr. Meants.d. 1.6 1 0.3 -0.111.0 4th Qtr. Meanis.d. 2.410.9 0.110.7 I }

  • low v lume; replaced pump.

b Volume estimated; new timer installed. Filter light. 91

Oi Cl BYRON Table 1. Airborne Particulates and Iodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units: 10r2pCi/m' BY-02(C) Stillman Valley g Date Volume Gross Date Volume Gross E 3 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 01-03-94 290 2.3 i 0.3 ; 0.5 -1.411.7;1.7 07-05-94 114 1.710.4;0.5 1.8 i 2.1 ; 2.1 01-10-94 286 2.710.4;0.6 -0.210.8;0.8 07-11-94 251 1.310.3;0.4 -1.4 i 2.3 ; 2.3 01-17-94 280 3.310.4;0.7 3.213.0;3.1 07 20-94 371 1.410.2;0.3 -1.111.6;1.6 01 24-94 284 3.4 i 0.4 ; 0.7 -0.1 i 0.7 ; 0.7 07 26-94 249 2.6 i 0.3 ; 0.6 -0.411.3;1.3 01-31-94 286 2.1 i 0.3; 0.5 0.111.1;1.1 08-02-94 292 2.410.3;0.5 -0.611.0;1.0 02-07 94 293 2.810.3;0.6 -0.1 i 1.0 ; 1.0 08-09-94 285 1.810.3;0.4 1.011.5;1.5 02-13-94 254 2.9 i 0.4 ; 0.6 -0.4 i 1.0 ; 1.0 08-16-94 284 1.5 i 0.3 ; 0.4 0.311.3;1.3 02-21-94 305 2.5 i 0.3; 0.5 -0.7 i 1.2 ; 1.2 08-23-94 287 2.110.3;0.5 0.9 i 1.1 ; 1.1 02-28-94 279 2.410.3;0.5 -0.5 i 1.4 ; 1.4 08-30-94 290 2.810.3;0.6 0.411.1;1.1 03-07-94 290 2.310.3;0.5 0.3 i 1.7 ;1.7 09-06-94 288 1.310.3;0.4 1.3 i 1.1 ; 1.1 03-15-94 323 2.1 i 0.3; 0.5 -0.3 i 1.2 ; 1.2 09-13-94 283 3.4 i 0.3 ; 0.7 -0.7i 1.0; 1.0 03-21-94 247 2.010.4;0.5 -0.3 i 1.5 ; 1.5 09-20-94 287 2.6 i 0.3; 0.6 -1.011.1;1.1 03-28-94 285 1.410.3;0.4 0.1 i 1.1 ; 1.1 09-27-94 285 1.610.3;0.4 0.311.1;1.1 1st Qtr. Meants.d. 2.5 1 0.5 0.011.0 3rd Qtr. Meanis.d. 2.0 1 0.6 0.l i 1.0 04-04-94 304 1.910.3;0.5 -0.6 i 1.0; 1.0 10-04-94 292 1.4 i 0.3 ; 0.4 -1.61 1.4;1.4 04-11-94 283 1.810.3;0.4 -0.611.3;1.3 10-11-94 285 1.810.3;0.4 -0.6 i 1.2 ; 1.2 04-16-94 206 0.910.3;0.3 1.711.7;1.7 10-18-94 286 2.410.3;0.5 0.0i 0.9;0.9 04-23-94 293 1.810.3;0.4 0.1 i 1.0; 1.0 10-25-94 287 2.5 i 0.3 ; 0.5 -0.31 0.8;0.8 04-30-94 277 1.0 i0.3 ; 0.3 0.211.3;1.3 11-01-94 288 1.6 i 0.3 ; 0.4 0.11 0.8;0.8 05-07-94 290 1.310.2;0.3 1.211.2;1.2 11-08-94 284 2.2 i 0.3 ; 0.5 0.3 i 1.2 ; 1.2 05-14-94 285 1.310.3;0.4 -0.4 i 1.4 ; 1.4 11 15-94 283 2.110.3;0.5 0.21 1.1;1.1 05-21-94 300 1.410.2;0.3 0.7 i 1.3; 1.3 11-22-94 287 2.3 i 0.3 ; 0.5 -0.3 i 1.5 ; 1.5 05-28-94 284 1.810.3;0.4 -0.411.2;1.2 11-29-94 286 2.0i 0.3; 0.5 1.31 0.9;0.9 06-04-94 289 2.110.3;0.5 1.210.9;0.9 12-06-94 289 2.7i 0.3 ; 0.6 0.41 1.0;1.0 06-11-94 277 1.910.3;0.5 -1.011.4;1.4 12-14-94 324 4.010.3;0.8 0.01 1.0;1.0 06-18-94 286 1.9 i0.3 ; 0.5 0.111.0;1.0 12-20-94 245 5.010.5;1.0 0.71 1.0;1.0 06-25-94 281 2.010.3;0.5 0.3 i 1.2; 1.2 12-27-94 285 3.210.3;0.6 0.2 i 1.1 ; 1.1 07-02-94 293 1.810.3;0.4 -0.6 i 1.3 ; 1.3 2nd Qtr. Meants.d. 1.6 1 0.4 -0.110.8 4th Qtr. Meants.d. 2.6 i 1.0 0.0 1 1.3 I 92 g 5

BYRON Table 1. Airborne Particulates and Iodine-131. Collections: Continuous; weekJy exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units: 10r2pCi/m' l BY-03 Nearsite - East Date Volume Gross Date Volume Gross Collected (nd ) Beta I-131 Collected (m ) Beta I131 3 01-03-94 285 2.310.3;0.5 0.8 i 1.7 ;1.7 07-05-94 112 1.3 i 0.4 ; 0.5 1.612.4;2.4 01-10-94 291 2.6 i 0.3 ; 0.5 -0.7 i 1.3 ;1.3 07-11-94 247 1.2i 0.3 ; 0.4 -0.5 i 1.3 ; 1.3 01-17-94 277 2.8 i 0.4 ; 0.6 0.1 i 2.3 ;2.3 07-20-94 366 1.7i 0.2 ; 0.4 0.2i 0.8 ; 0.8 01-24-94 280 2.710.4;0.6 -0.810.7;0.7 07-26-94 246 2.0 i 0.3 ; 0.5 -0.3 i 1.5 ; 1.5 01-31-94 295 1.810.3;0.4 0.3 1.0 ; 1.0 08-02-94 292 2.210.3;0.5 -0.4 i 1.1 ; 1.1 02-07-94 291 2.710.3;0.6 -0.211.0;1.0 08-09-94 284 1.610.3;0.4 -0.4 i 1.4 ; 1.4 02-13-94 250 2.7 i 0.4 ; 0.6 0.6 i 1.0 ;1.0 08-16-94 285 1.7i 0.3 ; 0.4 -1.4 1.3;1.3 02-21-94 267 2.5 i 0.3;0.5 1.011.1;1.1 08-23-94 282 1.7i 0.3 ; 0.4 0.5 i 0.9 ; 0.9 02-28-94 294 1.9 i 0.3 ; 0.4 -0.2 i 1.3 ;1.3 08-30-94 285 2.810.3;0.6 0.5 i 1.1 ; 1.1 03-07-94 285 2.7 i 0.4 ; 0.6 0.110.8;0.8 09-06-94 284 1.310.3;0.4 0.811.2;1.2 03-15-94 326 2.210.3;0.5 -0.5 i 1.0 ; 1.0 09-13-94 283 3.510.3;0.7 -0.5 i 1.1 ; 1.1 03-21-94 244 1.5 i 0.3; 0.4 0.3 i 1.3 ;1.3 09-20-94 287 2.310.3;0.5 -0.711.0;1.0 03-28-94 279 1.3 i 0.3; 0.4 0.1 i 1.2 ;1.2 09-27-94 280 1.210.3;0.4 0.5 i 1.3 ; 1.3 1st Qtr. Meanis.d. 2.3 1 0.5 0.1 i 0.5 3rd Qtr. Meanis.d. 1.91 0.7 0.0 1 0.8 04-04-94 315 1.910.3;0.5 -0.611.2;1.2 10-04-94 287 1.510.3;0.4 -0.5 i 1.4 ; 1.4 04-11-94 280 1.8 i2.8 ; 2.8 0.211.1;1.1 10-11-94 285 1.5 i 0.3 ; 0.4 -0.5 i 1.1 ; 1.1 04-16-94 197 1.0 i0.3 ; 0.3 0.211.6;1.6 10-18-94 281 2.210.3;0.5 -0.61 2.1;2.1 04-23-94 284 1.910.3;0.5 0.4 i 1.8;1.8 10-25-94 286 2.610.3;0.6 -0.71 0.9;0.9 04-30-94 283 0.910.3;0.3 -0.311.3;1.3 11-01-94 287 1.7i 0.3 ; 0.4 -0.11 1.2;1.2 05-07-94 286 1.8 i0.3 ; 0.4 0.111.4;1.4 11-08-94 284 2.010.3;0.5 -0.21 0.9;0.9 05-14-94 281 1.510.3;0.4 -0.111.4;1.4 11-15-94 283 2.0i 0.3 ; 0.5 0.2i 1.2 ; 1.2 05-21-94 279 1.110.2;0.3 0.7 i 1.3 ; 1.3 11-22-94 287 2.210.3;0.5 1.3 i 1.3 ; 1.3 { 05-28-94 280 1.80.3;0.4 0.1 i 1.4 ; 1.4 11-29-94 286 1.9 i 0.3 ; 0.5 -0.81 0.9;0.9 06-04-94 285 2.1 0.3 ; 0.5 -1.5 1.6 ; 1.6 12-06-94 289 2.4 i 0.3 ; 0.5 1.01 0.9;0.9 06-11-94 277 2.010.3;0.5 -0.411.3;1.3 12-14-94 324 3.210.3;0.6 -0.2 i 1.0; 1.0 ~ 06-18-94 286 1.910.3;0.5 0.0 i 1.2 ; 1.2 12-20-94 245 4.5 0.4 ; 0.9 0.71 1.8;1.8 06-25-94 281 1.9 i0.3 ; 0.5 -0.5 i 1.2; 1.2 12-27-94 285 2.8 i 0.3 ; 0.6 0.81 1.1;1.1 07-02-94 289 1.810.3;0.4 0.011.3;1.3 2nd Qtr. Meanis.d. 1.710.4 -0.110.5 4th Qtr. Meants.d. 2.3 i 0.8 0.0 1 1.3 E E 93 1

i O, 0' BYRON Table 1. Airbome Particulates and lodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m8 for Gross Beta and 0.07 pCi/m' for I-131 Units: 10~2pCi/m' BY-04 Paynes Point g Date Volume Gross Date Volume Groas E' Collected (nd ) Beta 1-131 Collected (m ) Beta I-131 i 3 01-03-94 285 2.210.3;0.5 -0.5 i 1.8 ; 1.8 07-05-94 114 1.510.4;0.5 0.512.4;2.4 01-10-94 286 2.8 i 0.4 ; 0.6 0.010.9;0.9 07-11-94 247 1.4 i 0.3 ; 0.4 0.811.7;1.7 01-17-94 286 2.5 i 0.4 ; 0.6 -0.612.0;2.0 07-20-94 366 1.610.2;0.4 0.6 i 1.7 ; 1.7 01-24-94 285 3.410.4;0.7 -2.1 i 2.5 ; 2.5 07-26-94 246 1.810.3;0.4 1.1 i 1.4 ; 1.4 ~ 01-31-94 285 2.010.3;0.5 -0.7 1.1 ; 1.1 08-02-94 292 3.410.3;0.7 -0.3 i 1.2 ; 1.2 02-07-94 286 3.210.4;0.7 -0.6 i 1.2 ; 1.2 08-09-94 289 1.510.2;0.3 -0.111.5;1.5 02-13-94 254 2.610.4;0.6 0.411.1;1.1 08-16-94 285 1.510.3;0.4 0.111.5;1.5 02-21-94 316 2.310.3;0.5 -0.7 i 0.9 ; 0.9 08-23-94 258" 0.610.2;0.2 1.311.2;1.2 02-28-94 289 2.110.3;0.5 -0.5 t 1.3 ; 1.3 08-30-94 290 2.710.3;0.6 1.011.1;1.1 03-07-94 286 2.410.3;0.5 0.2i 0.7;07 09-06-94 284 1.4 i 0.3 ; 0.4 0.2 i 1.2 ; 1.2 03-15-94 320 2.1 i 0.3 ; 0.5 0.411.0;1.0 09-13-94 283 3.4 0.3 ; 0.7 0.011.0;1.0 03-21-94 248 M i 0.3;0.4 1.6 i 1.2 ; 1.2 09-20-94 287 2.1 i 0.3 ; 0.5 0.211.1;1.1 03-28-94 284 1.310.3;0.4 -1.211.4;1.4 09-27-94 285 1.510.3;0.4 -0.111.2;1.2 ~ 1st Qtr. Meanis.d. 2.410.5 -0.3 1 0.9 3rd Qtr. Meands.d. 1.9 1 0.8 0.4 1 0.5 04-04 94 295 2.213.2;3.2 0.311.1;1.1 10-04-94 292 1.210.3;0.4 -0.81 1.4;1.4 04-11-94 279 1.712.8;2.8 0.111.0;1.0 10-11-94 285 1.410.3;0.4 1.21 1.0;1.0 04-16-94 200 0.610.3;0.3 -0.911.7;1.7 10-18-94 281 2.410.3;0.5 -0.31 1.1;1.1 04-23-94 279 1.510.3;0.4 -0.512.0;2.0 10-25-94 287 2.5 i 0.3 ; 0.5 0.61 1.2;1.2 04-30-94 273 0.9 iO 3 ; 0.3 0.4 i 1.5; 1.5 11-01-94 288 1.510.3;0.4 -0.2 i 1.3 ; 1.3 05-07-94 286 1.510.3;0.4 -0.6 i 1.6 ; 1.6 11-08-94 284 2.210.3;0.5 -0.41 1.7;1.7 1 05-14-94 281 1.210.3;0.4 0.211.3;1.3 11-15-94 283 2.0 0.3 ; 0.5 -0.11 1.0;1.0 05-21-94 286 1.110.2;0.3 0.5 i 1.4 ; 1.4 11-22-94 287 2.210.3;0.5 1.51 2.0;2.0 05-28-94 284 1.610.3;0.4 0.311.2;1.2 11-29-94 286 2.110.3;0.5 1.4 i 0.9 ; 0.9 l 06-04-94 281 1.6 i 0.3 ; 0.4 -1.2 i 1.4 ; 1.4 12-06-94 289 2.610.3;0.6 -0.11 1.0;1.0 06-11 94 282 1.6 i 0.3 ; 0.4 0.111.4;1.4 12-14-94 324 3.7i 0.3 ; 0.7 0.6 i 1.0 ; 1.0 06-18-94 286 1.810.3;0.4 0.211.1;1.1 12-20-94 245 5.010.5;1.0 0.21 1.1;1.1 06-25-94 285 1.810.3;0.4 -0.411.1;1.1 12-27-94 285 2.8 i 0.3 ; 0.6 -0.5 i 1.3 ; 1.3 07-02-94 293 1.510.3;0.4 -0.3 1.5 ; 1.5 2nd Qtr. Meants.d. 1.510.4 -0.110.5 4th Qtr. Meanis.d. 2.411.0 0.2 1 1.5 4Il

  • Filter light; sample damaged by heavy rain storm.

I 94 g sii,

l I BYRON Table 1. Airborne Particulates and lodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m for Gross Beta and 0.07 pCi/m for I-131 8 8 Units: IgrpCi/m' BY-05 Nearsite - souls Date Volume Gross Date Volume Cross 3 Collected (m ) Beta I131 Collected (m ) Beta I-131 3 I 01-03-94 280 2.310.3;0.5 0.7 i 1.4 ; 1.4 07-05-94 114 1.310.4;0.5 1.3 i 2.3 ; 2.3 g 01-10-94 286 2.610.4;0.6 0.6 1.8 ; 1.8 07-11-94 246 1.210.3;0.4 -4.2 i 2.0 ; 2.1 '3 01-17-94 291 3.810.4;0.8 0.011.3;1.3 07-20-94 366 1.610.2;0.4 0.2 i 0.6; 0.6 01-24-94 285 3.5 0.4 ; 0.7 -0.510.8;0.8 07-26-94 245 1.910.3;0.5 1.111.4;1.4 g 01-31-94 285 2.0 i 0.3 ; 0.5 0.5 i 1.0 ; 1.0 08-02-94 292 1.9 i 0.3 ; 0.5 -0.311.0;1.0 g 02-07-94 291 2.910.3;0.6 0.811.2;1.2 08-09-94 284 1.510.3;0.4 1.611.2;1.2 02-13-94 255 26i0.4;0.6 -0.611.0;1.0 08-16-94 285 1.6 i 0.3 ; 0.4 1.1 i 1.1 ; 1.1 02-21-94 316 2.410.3;0.5 -1.7 i 1.2 ; 1.2 08-23-94 282 1.3 i 0.2 ; 0.3 0.111.1;1.1 02-28 94 288 2.210.3;0.5 -0.911.4;1.4 08-30-94 290 2.7i 0.3 ; 0.6 1.111.2;1.2 03-07-94 286 2.510.3;0.5 0.510.8;0.8 09-06-94 284 1.410.3;0.4 0.111.2;1.2 03-15-94 320 2.410.3;0.5 -0.111.0;1.0 09-13-94 283 3.310.3;0.7 -0.8 1.2 ; 1.2 03-21-94 248 2.210.4;0.6 -0.3 i 1.4 ; 1.4 09-20-94 287 2.410.3;0.5 -0.2 i 1.2 ; 1.2 03-28-94 284 1.610.3;0.4 -0.211.1;1.1 09-27-94 285 1.510.3;0.4 0.6i 1.1 ; 1.1 1st Qtr. Meanis.d. 2.5 1 0.6 -0.110.7 3rd Qtr. Meanb.d. 1.81 0.6 0.l i 1.4 l j 04-04-94 295 2.013.1;3.1 1.011.0;1.0 10-04-94 292 1.310.3;0.4 0.2 1.2 ; 1.2 W 04-11-94 279 1.910.3;0.5 -0.511.2;1.2 10-11-94 285 1.510.3;0.4 -0.5 i 1.3 ; 1.3 04-16-94 200 0.910.3;0.3 0.4 i 1.8; 1.8 10-18-94 285 2.110.3;0.5 -1.81 2.0;2.0 g 04-23-94 289 1.712.7;2.7 -0.311.1;1.1 10-25-94 291 2.7 0.3 ; 0.6 0.1 i 1.0 ; 1.0 n 04-30-94 273 1.110.3;0.4 -0.911.4;1.4 11-01-94 288 1.710.3;0.4 0.3 i 0.6 ; 0.6 05-07-94 290 2.010.3;0.5 1.311.3;1.3 11-08-94 289 2.010.3;0.5 -0.81 1.0;1.0 E 5 4-94 281 1.410.3;0.4 -0.2 i 1.4 ; 1.4 11-15-94 283 2.310.3;0.5 -0.4 i 1.0 ; 1.0 g 05-21-94 286 1.110.2;0.3 0.1 i 1.4 ; 1.4 11-22-94 287 2.7 0.3 ; 0.6 -0.8 i 1.8 ; 1.8 05 28-94 284 2.00.3;0.5 -0.311.3;1.3 11-29-94 286 1.9 0.3 ; 0.5 0.1 i 0.9 ; 0.9 06-04-94 284 1.610.3;0.4 -0.6 i 1.5 ; 1.5 12-06-94 286 2.1 0.3 ; 0.5 0.6 i 0.9 ; 0.9 06-11-94 278 1.910.3;0.5 -0.9 1.5 ; 1.5 12-14-94 324 2.9 0.3 ; 0.6 -0.31 0.9;0.9 06-18-94 291 1.9 0.3 ; 0.5 1.811.4;1.4 12-20-94 245 5.110.5;1.0 0.0i 0.9; 0.9 06-25-94 281 2.0 i0.3 ; 0.5 -0.911.2;1.2 12-27-94 286 3.010.3;0.6 0.0i 1.2 ; 1.2 07-02-94 293 1.610.3;0.4 0.711.2;1.2 2nd Qtr. Meanis.d. 1.7 1 0.4 0.1 1 0.8 4th Qtr. Mean s.d. 2.4 0.9 -0.3 1 0.6 I 95

= 5 BYRON Table 1. Airborne Particulates and Jodine-131. Collections: Continuous; weekly exchange Required LLD- 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units: 102pCi/m 3 BY-06 Oregon Date Volume Gross Date Volume Gross 3 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 I 01-03-94 2M 2.3 i 0.3 ; 0.5 0.3 i 1.8 ;1.8 07-05-94 124 1.710.4;0.5 0.0i 2.3 ; 2.3 01-10-94 286 2.6 i 0.4 ; 0.6 0.1 i 1.2 ;1.2 07-11-94 245 1.4 i 0.3 ; 0.4 0.4 i 1.4 ; 1.4 01-17-94 292 4.110.4;0.8 0.4 i 1.0 ; 1.0 07-20-94 362 1.9 i 0.2 ; 0.4 0.0 1.2 ; 1.2 ~ 01-24-94 285 3.310.4;0.7 0.2 i 0.5 ;0.5 07-26-94 245 2.210.3;0.5 0.711.4;1.4 ~ 01-31-94 290 2.110.3;0.5 0 "' + 1.1 ; 1.1 08-02-94 291 1.8 i 0.3 ; 0.4 -0.6 i 1.1 ; 1.1 02-07-94 285 2.7 0.3 ; 0.6 -0 . 3 ; 1.3 08-09-94 285 1.710.3;0.4 0.6 i 1.5 ; 1.5 02-13-94 272 2.510.4;0.6 0.3.c 1.0 ; 1.0 08-16-94 286 1.510.3;0.4 1.4i1.3;1.3 g 02-21-94 278 3.310.4;0.7 -0.1 i 1.2 ; 1.2 08-23-94 279 2.5 i 0.3 ; 0.5 0.5 i 1.0 ; 1.0 3 02-28-94 310 1.8 i 0.3;0.4 0.4 i 1.0 ;1.0 08-30-94 290 2.9 i 0.3 ; 0.6 0.811.0;1.0 03-07-94 285 2.7 t 0.4 ; 0.6 -1.1 i 1.6 ; 1.6 09-06-94 287 1.6 i 0.3 ; 0.4 1.311.1;1.1 g 03-15-94 382 2.310.3;0.5 -0.5 i 1.2 ; 1.2 09-13-94 283 3.310.3;0.7 0.711.0;1.0 g 03-21-94 239 2.010.4;0.5 -0.111.6;1.6 09-20-94 285 2.510.3;0.5 0.4 i 1.1 ; 1.1 03-28-94 285 1.6 i 0.3; 0.4 0.311.1;1.1 09-27-94 279 1.7i 0.3 ; 0.4 0.111.4;1.4 1st Qtr. Meanis.d. 2.6 1 0.7 0.0 1 0.5 3rd Qtr. Meanis.d. 2.11 0.6 0.51 0.5 5 04-04-94 292 2.010.3;0.5 0.6 i 1.1 ; 1.1 10-04-94 291 1.210.3;0.4 0.0 1.3 ; 1.3 04-11-94 302 1.510.2;0.3 0.2 i 1.1 ; 1.1 10-11-94 287 1.6 i 0.3 ; 0.4 1.3 i 1.2 ; 1.2 04 16-94 174 1.2 i 0.4 ; 0.5 0.0 i 1.8; 1.8 10-18-94 280 2.3 0.3 ; 0.5 -0.71 1.0;1.0 l 04-23-94 289 1.510.3;0.4 0.5 i 1.0; 1.0 10-25-94 291 3.010.3;0.6 0.71 1.1;1.1 5 04-30-94 277 0.710.3;0.3 -0.5 i 1.4 ; 1.4 11-01-94 287 1.610.3;0.4 -1.11 1.1;1.1 05-07-94 293 1.6 i 0.3 ; 0.4 -0.411.4;1.4 11-08-94 285 2.2 i 0.3 ; 0.5 0.41 1.1;1.1 g 05-14-94 279 1.310.3;0.4 -1.4 i 1.5; 1.5 11-15-94 284 2.110.3;0.5 0.01 1.2;1.2 E 05-21-94 285 1.310.2;0.3 -0.4 i 1.4 ; 1.4 11-22-94 286 2.610.3;0.6 0.11 1.4;1.4 05-28-94 295 1.910.3;0.5 -1.011.5;1.5 11-29-94 286 1.810.3;0.4 1.01 0.9;0.9 g 06-04-94 287 1.810.3;0.4 1.411.3;1.3 12-06-94 286 2.810.3;0.6 -0.91 1.0;1.0 g 06-11-94 284 1.810.3;0.4 -1.011.4;1.4 12-14 94 320 3.210.3;0.6 -0.71 1.0;1.0 06-18-94 280 1.9 i 0.3 ; 0.5 -0.911.4;1.4 12-20-94 244 4.810.4;1.0 -0.51 2.2;2.2 g 06-25-94 280 1.910.3;0.5 -0.5 i 1.2; 1.2 12-27-94 291 3.010.3;0.6 0.3 i 1.1 ; 1.1 g 07-02-94 282 2.1 i 0.3 ; 0.5 0.5 i 1.4 ; 1.4 2nd Qtr. Meanis.d. 1.6 1 0.4 -0.210.7 4th Qtr. Meants.d. 2.5 1 0.9 0.0 i 1.3 I 96 =

r L [ L BYRON Table 1. Airbome Particulates and Iodine-131. Collections: Cortinuous; weekly exchange Required LLD: 0.01 pCi/m' for Cross Beta and 0.07 pCi/m for I-131 2 Units: 104pCi/m' L BY-07(C) Mt. Morris Date Volume Gross Date Volume Gross { 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 3 01-03-94 288 2.210.3;0.5 0.711.6;1.6 07-05-94 122 1.4 i 0.4 ; 0.5 1.4 1 2.2 ; 2.2 01-10-94 274 2.8 i 0.4 ; C.6 0.812.1;2.1 07-11-94 245 1.4 i 0.3 ; 0.4 -1.0 i 1.9 ; 1.9 01-17-94 241 4.010.4;0.8 -0.1 i 1.2 ; 1.2 07-20-94 362 1.7 i 0.2 ; 0.4 0.1 i 0.6 ; 0.6 r ( 01-24-94 263 3.610.4;0.7 -0.110.7;0.7 07-26-94 249 1.610.3;0.4 1.3 i 1.5 ; 1.5 01-31-94 294 2.010.3;0.5 0.1 i 0.9 ; 0.9 08-02-94 285 1.510.3;0.4 -0.1 i 1.1 ; 1.1 02-07-94 284 3.2 0.4 ; 0.7 -0.711.3;1.3 08-09-94 290 1.610.3;0.4 0.411.6;1.6 02-13-94 248 2.4 i 0.4 ; 0.6 0.3 i 1.2 ;1.2 08-16-94 286 1.610.3;0.4 0.2 i 1.4 ; 1.4 02-21-94 301 2.410.3;0.5 -0.711.2;1.2 08-23-94 284 1.7i 0.3 ; 0.4 -0.611.0;1.0 02-28-94 256 2.6 i 0.4 ;0.6 0711.4;1.4 08-30-94 285 2.810.3;0.6 0.511.1;1.1 [ 03-07-94 289 2.2 i 0.3 ; 0.5 0.2 i 1.5 ;1.5 09-06-94 286 1.210.3;0.4 0.411.2;1.2 03-15-94 316 2.310.3;0.5 0.2 i 1.4 ; 1.4 09-13-94 285 3.4 i 0.4 ; 0.7 0.5 i 1.0 ; 1.0 03-21-94 248 2.010.3;0.5 -0.4 i 1.5 ; 1.5 09-20-94 286 2.5 i 0.3 ; 0.5 0.6 i 1.0 ; 1.0 { 03-28-94 285 1.6 i 0.3;0.4 1.7 1.1 ; 1.1 09-27-94 280 1.7i 0.3 ; 0.4 0.0i 1.3 ; 1.3 1st Qtr. Mean s.d. 2.6 1 0.7 0.2 1 0.6 3rd Qtr. Meanis.d. 1.9 1 0.6 0.3 1 0.6 e b 04-04-94 291 2.1 i0.3 ; 0.5 -0.611.2;1.2 10-04-94 286 1.010.3;0.3 -0.31 1.3;1.3 p 04-11-94 283 1.8 i0.3 ; 0.4 -0.3 1.2 ; 1.2 10-11-94 287 1.6 i 0.3 ; 0.4 -0.4 i 1.1 ; 1.1 04-16-94 197 0.610.3;0.3 0.7 i 1.6; 1.6 10.18-94 280 2.4 0.3 ; 0.5 0.0i 1.6; 1.6 04-23-94 284 1.80.3;0.4 -0.111.7;1.7 10-25-94 295 2.810.3;0.6 0.61 1.0;1.0 04-30-94 279 0.910.3;0.3 -0.6 i 1.3; 1.3 11-01-94 286 1.6 i 0.3 ; 0.4 0.31 1.1;1.1 05-07-94 282 1.510.3;0.4 -1.6 i 1.4; 1.4 11-08-94 286 2.0i 0.3 ; 0.5 0.7i 0,9; 0.9 05-14-94 285 1.610.3;0.4 -0.111.5;1.5 11-15-94 284 2.210.3;0.5 -0.2 i 1.0 ; 1.0 05-21-94 285 1.010.2;0.3 1.011.5;1.5 11-22-94 286* 2.410.3;0.5 0.5 i 1.3 ; 1.3 ( 05-28-94 285 1.710.3;0.4 -0.111.4;1.4 11-29-94 282 1.6 i 0.3 ; 0.4 -0.5 i 1.0 ; 1.0 06-04-94 282 1.80.3;0.4 -0.4 1.4 ; 1.4 12-06-94 286 2.6 0.3;0.6 -0.41 1.0;1.0 06-11-94 280 1.9 i 0.3 ; 0.5 1.2 i 1.3; 1.3 12-14-94 287 3.8 i 0.4 ; 0.8 0.1 1.1 ; 1.1 I 06-18-94 285 1.9 i 0.3 ; 0.5 -0.511.4;1.4 12-20-94 244 5.2 i 0.5 ; 1.1 0.81 1.1;1.1 8 06-25-94 281 2.010.3;0.5 -0.311.2;1.2 12-27-94 250 3.4 i 0.4 ; 0.7 0.2 i 1.2 ; 1.2 07-02-94 282 1.810.3;0.4 -0.611.4;1.4 2nd Qtr. Mean s.d. 1.610.4 -0.210.7 4th Qtr. Meanis.d. 2.5 i 1.1 0.110.8

  • Volume estimated.

( 97 - - - - - - - - - ' - - - - - - - - ' ~ ^ ~ ~ ~ ~ ~ ^ ~ ~ ~ ~ ~ ~ ~

O Ol BYRON j i Table 1. Airborne Particulates and Iodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units: 10-2 pCi/m' BY-08(C) Leaf River Date Volume Gross Date Volume Gross 3 3 Collected (m ) Beta 1-131 Collected (m ) Beta I-131 I 01-03-94 288 2.410.3;0.5 -1.611.6;1.6 07-05-94 122 1.610.4;0.5 3.412.2;2.3 g 01-10-94 287 2.410.3;0.5 0.011.2;1.2 07-11-94 245 1.1 i 0.3 ; 0.4 0.4 i 1.5 ; 1.5 5 01-17-94 292 3.810.4;0.8 0.211.9;1.9 07-20-94 368 1.810.2;0.4 0.4 i 1.0 ; 1.0 01-24-94 294 2.9 i 0.4 ; 0.6 0.110.8;0.8 07-26-94 245 1.910.3;0.5 -0.311.6;1.6 ~ 01-31-94 291 2.210.3;0.5 0.6 i 1.0 ;1.0 08-02-94 290 2.010.3;0.5 0.210.8;0.8 j 02-07-94 288 3.210.4;0.7 -0.111.3;1.3 08-09-91 290 1.6 i 0.3 ; 0.4 -0.8 i 1.9 ; 1.9 ) 02-13-94 254 2.610.4;0.6 -1.4 1 1.1 ;1.1 08-16-94 290 1.610.3;0.4 1.4 i 1.5 ; 1.5 02-21-94 295 2.6 i 0.3 ; 0.5 -0.811.3;1.3 08-23-94 288 1.9 i 0.3 ; 0.5 0.4 i 1.0 ; 1.0 02 28-94 288 2.010.3;0.5 0.411.1;1.1 08-30-94 280 2.6 i 0.3 ; 0.6 -0.6 i 1.2 ; 1.2 03-07-94 286 2.2 i 0.3 ; 0.5 0.2 i 1.7 ; 1.7 09-06-94 287 1.5 i 0.3 ; 0.4 -0.6 i 1.3 ; 1.3 03-15-94 327 2.010.3;0.5 0.8 i 1.2 ; 1.2 09-13-94 285 3.210.4;0.7 0.7 i 0.9 ; 0.9 03-21-94 247 1.710.3;0.4 -0.811.5;1.5 09-20-94 286 2.510.3;0.5 -0.9 i 1.2 ; 1.2 03-28-94 290 1.7 i 0.3 ; 0.4 0.4 i 1.1 ; 1.1 09-27-94 284 1.510.3;0.4 0.411.3;1.3 1st Qtr. Meanis.d. 2.4 0.6 -0.210.7 3rd Qtr. Mean s.d. 1.9 1 0.5 0.3 1 1.1 } l l } 04-04-94 289 2.110.3;0.5 -1.5 i 1.4 ; 1.4 10-04-94 286 1.410.3;0.4 0.6 i 1.0 ; 1.0 5 04-11-94 295 1.610.3;0.4 -1.1 i 1.2; 1.2 10-11-94 291 2.110.3;0.5 0.21 1.2;1.2 04-16-94 187 1.010.4;0.4 1.211.7;1.7 10-18-94 280 2.4 0.3 ; 0.5 -0.1 i 0.8 ; 0.8 04-23-94 280 1.8 i0.3 ; 0.4 0.8 1.4 ; 1.4 10-25-94 291 2.6 i 0.3 ; 0.6 -0.5 i 1.2 ; 1.2 04-30-94 283 1.010.3;0.3 0.4 i 1.2; 1.2 11-01-94 287 1.8 0.3 ; 0.4 -1.11 1.7;1.7 05-07-94 306 1.510.2;0.3 0.411.2;1.2 11-08-94 286 2.2 i 0.3 ; 0.5 1.0 i 1.1 ; 1.1 g 05-14-94 290 1.510.3;0.4 0.111.1;1.1 11-15-94 284 2.2 0.3 ; 0.5 0.41 1.1;1.1 g 05-21-94 285 1.30.2;0.3 1.211.4;1.4 11-22-94 286 2.410.3;0.5 .-l.6 i 2.1 ; 2.1 05-28-94 285 1.910.3;0.5 0.1 1 1.2;1.2 11-29-94 287 1.8 i 0.3 ; 0.4 0.31 1.0;1.0 06-04-94 291 2.0 i0.3 ; 0.5 1.411.5;1.5 12-06-94 286 2.810.3;0.6 -0.5 i 1.1 ; 1.1 06-11-94 285 1.7 i 0.3 ; 0.4 -0.3 i 1.4 ; 1.4 12-14-94 326 3.510.3;0.7 0.2 i 0.9 ; 0.9 06-18-94 285 1.810.3;0.4 -0.9 i 1.4 ; 1.4 12-20-94 244 5.010.5;1.0 0.6 i 1.0 ; 1.0 l 06-25-94 290 1.910.3;0.5 0.5 i 1.2;1.2 12-27-94 286 3.210.3;0.6 0.11 0.9;0.9 07-02 94 281 1.610.3;0.4 0.1 i 1.5 ; 1.5 2nd Qtr. Meants.d. 1.610.3 0.2 1 0.8 4th Qtr. Meants.d. 2.6 1 0.9 0.0 1 1.0 { l 98 lw

I = BYRON Table 1. Airborne Particulates and Iodine-131. Collections: Continuous; weekly exchange 8 2 Required LLD: 0.01 pCi/m for Gross Beta and 0.07 pCi/m for I-131 Igr Ci/m' Units: p BY-21 Byron Nearsite N Date Volume Gross Date Volume Gross 3 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 01-03-94 279 2.510.3;0.5 0.0 i 0.8 ;0.8 07-05-94 115 1.4 i 0.4 ; 0.5 0.4 2.6 ; 2.6 I 01-10-94 287 2.3 i 0.3 ; 0.5 0.3 0.8 ; 0.8 07-11-94 246 1.3 i 0.3 ; 0.4 0.011.7;1.7 01-17-94 290 3.410.4;0.7 -1.2 1.8 ; 1.8 07-20-94 360 1.6 i 0.2 ; 0.4 0.6 i 0.9 ; 0.9 01-24-94 286 3.1 i 0.4 ; 0.7 -1.5 1.4 ; 1.4 07-26-94 245 1.6 i 0.3 ; 0.4 -0.411.4;1.4 01-31-94 284 2.210.3;0.5 0.311.0;1.0 08-02-94 292 1.6 i 0.3 ; 0.4 -0.6 i 1.1 ; 1.1 02-07-94 290 3.210.4;0.7 0.111.3;1.3 08-09-94 289 1.410.2;0.3 0.2 i 1.1 ; 1.1 02-13-94 264 2.110.4;0.5 0.311.1;1.1 08-16-94 285 1.3 i 0.3 ; 0.4 0.6 i 1.4 ; 1.4 02-21-94 315 2.510.3;0.5 0.311.2;1.2 08-23-94 285 2.0 0.3 ; 0.5 1.2 i 1.1 ; 1.1 02-28-94 290 2.010.3;0.5 -0.111.3;1.3 08-30-94 285 2.5 i 0.3 ; 0.5 0.411.2;1.2 03-07-94 285 2.8 i 0.4 ; 0.6 -0.911.6;1.6 09-06 94 287 1.410.3;0.4 -0.5 i 1.1 ; 1.1 C 03-15-94 321 2.0 i 0.3 ; 0.5 -0.1 i 1.1 ; 1.1 09-13-94 242 3.710.4;0.8 0.6 i 1.5 ; 1.5 I 03-21-94 247 2.110.4;0.5 0.0 i 1.6 ;1.6 09-20-94 284 2.1 i 0.3 ; 0.5 -1.211.1;1.1 03-28-94 284 1.1 i 0.3 ; 0.4 -2.1 i 1.4 ; 1.4 09-27-94 284 1.6 0.3 ; 0.4 0.111.3;1.3 1st Qtr. Mean s.d. 2.4 i 0.6 -0.410.8 3rd Qtr. Mean s.d. 1.8i 0.6 0.1 0.6 04-04-94 288 2.210.3;0.5 0.5 1.2 ; 1.2 10-04-94 286 1.2 i 0.3 ; 0.4 -0.31 1.2;1.2 04-11-94 280 1.910.3;0.5 -0.411.1;1.1 10-11-94 287 1.5 0.3 ; 0.4 -0.5 i 1.1 ; 1.1 04-16-94 208 1.0 i0.3 ; 0.3 1.211.7;1.7 10-18-94 280 2.2 i 0.3 ; 0.5 0.4 i 1.4 ; 1.4 04-23-94 271 1.810.3;0.4 0.311.9;1.9 10-25-94 286 2.810.3;0.6 0.2 i 1.2 ; 1.2 04-30-94 288* 0.8 i0.3 ; 0.3 -3.113.7;3.7 11-01-94 287 1.810.3;0.4 0.61 1.4;1.4 05-07-94 285 1.410.3;0.4 -1.5 i 1.3 ; 1.3 11-08-94 285 2.1 i 0.3 ; 0.5 -0.1 i 1.2 ; 1.2 I 05-14-94 272 1.4 i0.3 ; 0.4 -0.2 i 1.5 ; 1.5 11-15-94 283 1.710.3;0.4 0.2 i 1.0 ; 1.0 05-21-94 285 1.210.2;0.3 0.811.3;1.3 11-22-94 286 2.2 i 0.3 ; 0.5 0.71 0.9;0.9 05-28-94 286 1.7i0.3 ; 0.4 0.5 i 1.5 ; 1.5 11-29-94 286 1.9 i 0.3 ; 0.5 -0.31 0.9;0.9 06-04-94 283 1.710.3;0.4 -0.1 i 1.5 ; 1.5 12-06-94 287 2.210.3;0.5 -0.41 1.2;1.2 I 06-11-94 283 2.1 0.3 ; 0.5 -0.2 i 1.5 ; 1.5 12-14-94 325 3.6 0.3 ; 0.7 0.0 0.9 ; 0.9 L 06-18-94 286 1.9 i0.3 ; 0.5 -0.811.5;1.5 12-20-94 245 5.010.5;1.0 -0.2 i 1.4 ; 1.4 06-25-94 281 2.2 i0.3 ; 0.5 -0.3 i 1.2 ; 1.2 12-27-94 286 3.310.3;0.7 0.8 i 1.1 ; 1.1 I 07-02-94 287 1.810.3;0.4 -0.311.3;1.3 2nd Qtr. Meants.d. 1.7 i 0.4 -0.3 i 1.0 4th Qtr. Meants.d. 2.411.0 0.110.8

  • Estimated reading.

b I Estimated reading; replaced timer. Low volume; pump out of service for 24 hours while installing new air sampler housing. 99 ~

O! BYRON Table 1. Airborne Particulates and Iodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units: 10r pCi/m' r BY-22 Byron Nearsite ESE g Date Volume Gross Date Volume Gross E 3 Collected (m ) Beta 1-131 Collected (m ) Beta I-131 3 01-03-94 284 2.510.3;0.5 -0.8 i 1.7 ; 1.7 07-05-94 113 1.4 i 0.4 ; 0.5 -1.012.5;2.5 01-10-94 287 2.310.3;0.5 -0.311.8;1.8 07-11-94 242 1.4 i 0.3 ; 0.4 1.3 i 1.5 ; 1.5 01-17-94 291 3.710.4;0.8 -0.111.2;1.2 07-20-94 360 1.410.2;0.3 1.0i 0.9 ; 0.9 01-24-94 285 3.5 i 0.4 ; 0.7 0.210.8;0.8 07-26-94 249 1.8 i 0.3 ; 0.4 0.011.5;1.5 ~ 01-31-94 290 2.2 i 0.3 ; 0.5 0.0 i 1.0 ; 1.0 08-02-94 292 1.810.3;0.4 -1.0 i 1.1 ; 1.1 g g 02-07-94 290 3.210.4;0.7 0.8 i 1.1 ;1.1 08-09-94 284 1.610.3;0.4 -0.411.7;1.7 02-13-94 259 2.4 i 0.4 ; 0.6 -0.2 i 1.0 ; 1.0 08-16-94 285 1.610.3;0.4 -0.2 i 1.6 ; 1.6 02-21-94 309 2.510.3;0.5 -0.5 i 1.2 ; 1.2 08-23-94 282 1.0 0.2 ; 0.3 -0.4 i 1.2 ; 1.2 02-28-94 290 2.410.3;0.5 0.111.3;1.3 08-30-94 285 2.9 i 0.3 ; 0.6 -0.1 i 1.4 ; 1.4 03-07-94 285 2.7 i 0.4 ; 0.6 -0.311.7;1.7 09-06-94 287 1.310.3;0.4 -0.5i 1.4 ; 1.4 03-15-94 321 2.410.3;0.5 -0.8.t 1.4 ; 1.4 09-13-94 284 3.210.4;0.7 0.111.2;1.2 l 03-21-94 245 1.810.3;0.4 -0.711.6;1.6 09-20-94 292 2.410.3;0.5 0.7i 1.0 ; 1.0 = 03-28-94 284 1.610.3;0.4 0.1 1 1.2 ;1.2 09-27-94 275 1.4 i 0.3 ; 0.4 -0.8i 1.4 ; 1.4 1st Qtr. Meanis.d. 2.6 1 0.6 -0.210.4 3rd Qtr. Meants.d. 1.8 1 0.6 -0.1 1 0.7 04-04-94 293 2.410.3;0.5 -0.211.2;1.2 10-04-94 296 1.5 i 0.3 ; 0.4 0.2 1.3; 1.3 04-11-94 279 1.710.3;0.4 0.111.1;1.1 10-11-94 282 1.5 i 0.3 ; 0.4 0.611.3;1.3 04-16-94 205 0.910.3;0.3 0.8 i 1.7; 1.7 10-18-94 284 2.410.3;0.5 0.3 i 0.8 ; 0.8 g 04-23-94 279 1.9 i 0.3 ; 0.5 0.511.0;10 10-25-94 287 2.510.3;0.5 0.01 1.2;1.2 g 04-30-94 279 0.7 i 0.3 ; 0.3 0.111.2;1.2 11-01-94 287 1.710.3;0.4 0.21 1.7;1.7 05-07-94 285 1.610.3;0.4 0.6 i 1.4 ; 1.4 11-08-94 285 2.1 i 0.3 ; 0.5 0.41 1.2;1.2 05-14-94 282 1.410.3;0.4 -0.2 1.4 ; 1.4 11-15-94 283 2.010.3;0.5 -0.4 i 1.2 ; 1.2 05-21-94 290 1.010.2;0.3 1.211.3;1.3 11-22-94 286 2.2 i 0.3; 0.5 -0.51 1.3;1.3 05-28-94 286 1.810.3;0.4 0.411.3;1.3 11-29-94 286 1.810.3;0.4 -0.1 i 0.9 ; 0.9 06-04-94 292 1.510.3;0.4 1.111.1;1.1 12-06-94 287 2.110.3;0.5

0. l i 1.0 ; 1.0 06 11-94 270 2.010.3;0.5 0.3 i 1.5; 1.5 12-14-94 330 3.610.3;0.7 0.1 0.9 0.9 06-18-94 111^

1.910.3;0.5 0.5 i 3.0; 3.0 12-20-94 245 4.610.4;0.9 0.2 i 1.0; 1.0 06-25-94 161^ 1.910.4;0.5 1.012.1;2.1 12-27-94 286 3.310.3;0.7 0.11 1.2;1.2 l 07-02-94 296 1.710.3;0.4 -0.711.4;1.4 5 2nd Qtr. Meanis.d. 1.6 1 0.5 0.4 1 0.5 4th Qtr. Meants.d. 2.410.9 0.1 1 0.6

  • low volume; no power I

100 E_ m

I BYRON Table 1. Airborne Particulates and lodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units: 10'2 pCi/m' BY-23 Byron Nearsite S I Date Volume Gross Date Volume Gross 3 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 01-03-94 284 2.210.3;0.5 0.111.0;1.0 07-05-94 114 1.910.4;0.5 0.012.7;2.7 01-10-94 292 2.4 i 0.3 ; 0.5 -0.2 i 0.8 ; 0.8 07-11-94 246 1.110.3;0.4 0.8 i 1.8 ; 1.8 01 17-94 290 3.9 i 0.4 ; 0.8 -0.911.4;1.4 07-20-94 360 2.1 i 0.3 ; 0.5 -0.410.8;0.8 01-24-94 290 3.710.4;0.8 0.111.4;1.4 07-26-94 245 1.710.3;0.4 -0.911.3;1.3 ~ 01-31-94 295 2.110.3;0.5 0.2 1.1 ; 1.1 08-02-94 297 1.910.3;0.5 1.110.9;0.9 02-07-94 295 3.2 0.4 ; 0.7 -0.711.2;1.2 08-09-94 284 1.6 0.3 ; 0.4 0.8 i 1.4 ; 1.4 02-13-94 255 2.810.4;0.6 0.411.0;1.0 08-16-94 285 1.5 i 0.3 ; 0.4 -1.1 i 1.5 ; 1.5 02-21-94 306 2.510.3;0.5 -0.111.2;1.2 08-23-94 282 1.110.2;0.3 -0.511.2;1.2 02-28-94 290 2.0 i 0.3 ; 0.5 -0.211.3;1.3 08-30-94 285 2.710.3;0.6 0.6 i 1.1 ; 1.1 03-07-94 280* 2.310.3;0.5 -0.5 1.8 ; 1.8 09-06-94 287 1.310.3;0.4 -0.7i 1.4 ; 1.4 03-15-94 320 2.410.3;0.5 1.4 1.2 ; 1.2 09-13-94 284 3.7i 0.4 ; 0.8 1.310.9;0.9 03-21-94 248 1.810.3;0.4 -0.711.3;1.3 09-20-94 287 2.110.3;0.5 -0.811.1;1.1 03-28-94 284 1.510.3;0.4 1.011.3;1.3 09-27-94 284 1.710.3;0.4 0.211.2;1.2 1st Qtr. Meants.d. 2.5 1 0.7 0.0 1 0.6 3rd Qtr. Mean s.d. 1.91 0.7 0.0 1 0.8 I b I 04-04-94 293 2.410.3;0.5 -0.111.1;1.1 10-04-94 143 1.2 i 0.4 ; 0.5 -2.51 3.4;3.4 04-11-94 279 1.710.3;0.4 -0.6 i 1.3; 1.3 10-11-94 286 1.7i 0.3 ; 0.4 0.31 1.2;1.2 04-16-94 205 0.910.3;0.3 -0.5 i 1.7; 1.7 10-18-94 280 2.2 i 0.3 ; 0. 5 0.61 1.2;1.2 I 04-23-94 279 1.710.3;0.4 -0.3 i 0.9; 0.9 10-25-94 287 2.7 0.3 ; 0.6 -0.51 1.3;1.3 04-30-94 279 1.010.3;0.3 -0.2 i 1.1 ; 1.1 11-01-94 287 1.710.3;0.4 0.01 1.2;1.2 05-07-94 290 1.610.3;0.4 0.811.3;1.3 11-08-94 285 2.310.3;0.5 -1.0 i 1.2 ; 1.2 05-14-94 286 1.310.3;0.4 -0.3 1.3 ; 1.3 11-15-94 283 2.1 i 0.3 ; 0.5 -0.31 1.2;1.2 05-21-94 285 1.510.2;0.3 -0.1 i 1.4 ; 1.4 11-22-94 286 2.1 0.3 ; 0.5 -1.3 1.1:1.1 05-28-94 285 1.810.3;0.4 0.2 1.4 ; 1.4 11-29-94 286 2.010.3;0.5 0.5 1.0; 1.0 06-04-94 288 1.610.3;0.4 -0.4 i 1.7; 1.7 12-06-94 287 2.610.3;0.6 -0.3 i 1.1 ; 1.1 I 06-11-94 279 1.810.3;0.4 0.4 1.4 ; 1.4 12-14-94 325 3.410.3;0.7 -0.11 1.0;1.0 06-18-94 291 2.010.3;0.5 -1.3 i 1.4 ; 1.4 12-20-94 245 4.8 0.4 ; 1.0 -0.110.8;0.8 06-25-94 281 1.610.3;0.4 -0.1 i 1.3; 1.3 12-27-94 285 3.110.3;0.6 0.4 i 1.2 ; 1.2 07-02-94 288 1.70.3;0.4 -2.2 i 1.5 ; 1.5 2nd Qtr. Mean s.d. 1.6 0.4 -0.310.7 4th Qtr. Mean s.d. 2.5 1 0.9 -0.3 1 0.6 I ^ V lume estimated; new timer installed. b Pump found not runrung; replaced pump. ~ 101

Ea= BYRON I Table 1. Airbome Particulates and Jodine-131. Collections: Continuous; weekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 2 Units: 10 pCi/m' BY-24 Byron Nearsite SW Date Volume Gross Date Volume Gross 3 3 Collected (m ) Beta I-131 Collected (m ) Beta I-131 I 01-03-94 284 2.510.3;0.5 0.0 i 1.7 ;1.7 07-05-94 114 1.310.4;0.5 0.112.5;2.5 01-10-94 287 2.5 i 0.3 ; 0.5 -0.111.6;1.6 07-11-94 246 1.210.3;0.4 1.2 i 1.8 ; 1.8 01-17-94 NS* 07 20-94 366 1.910.2;0.4 -0.610.9;0.9 01 24-94 571 3.410.2;0.6 0.010.3;0.3 07-26-94 249 1.610.3;0.4 0.4 i 1.6 ; 1.6 g ~ 01-31-94 290 2.410.3;0.5 0.211.1;1.1 08-02-94 292 1.710.3;0.4 -0.211.1;1.1 3 02-07-94 293 3.4 i 0.4 ; 0.7 0.611.1;1.1 08-09-94 284 1.610.3;0.4 -0.311.4;1.4 02-13-94 254 2.510.4;0.6 -0.211.2;1.2 08-16-94 285 1.610.3;0.4 2.1i1.5;1.5 02-21-94 309 2.6 i 0.3; 0.5 0.8 i 2.0 ;2.0 08-23-94 280 2.310.3;0.5 -0.1 i 1.2 ; 1.2 02-28-94 289 2.010.3;0.5 2.0 i 1.3 :1.3 08-30-94 285 2.7 0.3 ; 0.6 0.7 t 1.1 ; 1.1 03-07-94 286 3.010.4;0.7 1.2 i 1.4 : 1.4 09-06-94 287 1.610.3;0.4 1.311.3;1.3 03-15-94 320 1.810.3;0.4 -0.7 i 1.4 ;1.4 09-13-94 284 3.610.4;0.8 -0.2 i 1.2 ; 1.2 03-21-94 248 1.710.3;0.4 0.811.3;1.3 09-20-94 287 2.410.3;0.5 -0.111.0;1.0 03-28-94 265 1.210.3;0.4 -0.2 i 0.5 ; 0.5 09-27-94 284 1.6 0.3 ; 0.4 1.011.6;1.6 1st Qtr. Meanis.d. 2.410.6 0.4 i 0.7 3rd Qtr. Meanis.d. 1.91 0.6 0.41 0.8 04-04-94 285 1.510.3;0.4 0.1 1 1.1; 1.1 10-04-94 287 1.410.3;0.4 -0.41 1.5;1.5 04-11-94 278 1.910.3;0.5 1.411.2;1.2 10-11-94 285 1.610.3;0.4 -1.11 1.2;1.2 04-16-94 195 1.00.3;0.3 -0.6 i 1.6; 1.6 10-18-94 285 2.2 i 0.3 ; 0.5 -0.41 1.0;1.0 g b 04-23-94 211 2.010.4;0.5 0.711.9;1.9 10-25-94 287 2.7i 0.3 ; 0.6 -0.3 1.3 ; 1.3 5 04-30-94 283 0.710.3;0.3 -1.611.5;1.5 11-01-94 287 1.610.3;0.4 0.3 i 1.5 ; 1.5 05-07-94 285 1.410.3;0.4 -0.711.5;1.5 11-08-94 285 2.110.3;0.5 0.11 1.1;1.1 05-14-94 281 1.410.3;0.4 -0.711.5;1.5 11-15-94 283 2.310.3;0.5 0.7 i 1.1 ; 1.1 05-21-94 285 1.210.2;0.3 0.6 i 1.3; 1.3 11-22-94 291 2.2 i 0.3 ; 0.5 -0.11 1.1:1.1 05-28-94 286 1.9 i0.3 ; 0.5 -0.2 i 1.3; 1.3 11-29-94 282 1.910.3;0.5 -0.21 1.1;1.1 g 06-04-94 288 1.610.3;0.4 -1.311.6;1.6 12-06-94 283 2.310.3;0.5 0.11 1.3;1.3 g C 06-11-94 283 1.710.3;0.4 -0.411.2;1.2 12-14-94 324 3.8 0.3 ; 0.7 -1.2 i 1.5 ; 1.5 06-18-94 286 2.210.3;0.5 0.5 i 1.1; 1.1 12-20-94 245 5.010.5;1.0 2.01 1.8;1.8 06-25-94 285 1.9 i 0.3 ; 0.5 -0.111.3;1.3 12-27-94 285 3.310.3;0.7 0.51 1.1;1.1 l 07-02-94 293 1.610.3;0.4 -0.4 i 1.5; 1.5 \\ 2nd Qtr. Meanis.d. 1.6 1 0.4 -0.2 i 0.8 4th Qtr. Meanis.d. 2.5 1 1.0 0.0 1 2.0 " NS = No Sample; inaccessible due to snowy conditions. g b Low volume. B Volume estimated. I 102 g

L [ BYRON r Table 2. Airborne Particulates Collection: Quarterly composites of weekly collections Requi-M LLD: 0.05 pCi/m3 for Cs-134 and 0.06 pCi/m3 or Cs-137 and f 0.01 pCi/m3 for all other gamma emitters u Units: 10-4 pCi/m3 IL Sample Description and Concentration f~ BY-01 Byron 1994 L Collection Period 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. p Lab Code BYAP-4028 BYAP-4140 BYAP-4256 BYAP-8304 L Volume 3486 3894 3554 3735 [ Mn-54 0.5i6.5;6.5 6.4110.4;10.5 0.7i7.2;7.2 -0.215.3;5.3 Fe-59 3.716.0;6.0 -28.6i24.0;24.5 -4.8i7.2;7.2 1.6i16.3;16.3 Co-58 -5.li9.5;9.5 -8.017.5;7.6 0.3 7.3;7.3 3.2i6.8;6.8 E Co-60 4.41103;103 -4.8ill.2;11.2 5.6112.2;12.2 -3.3i7.0;7.0 Zn-65 -14.6121.0;21.0 3.910.1;0.7 -8.4112.1;12.1 9.9115.1;15.1 Zr-Nb-95 -5.519.2;9.2 16.9117.9;18.2 -1.5fl.3;1.3 8.2il2.8;12.8 Cs-134 4.015.6;5.6 0.8112.0;12.0 -1.4tl.4;1.4 -3.6i6.2;6.2 L Cs-137 -1.415.0;5.0 1.2i10.7;10.7 0.6i6.6;6.6 0.915.4;5.4 Ba-La-140 29.4i55.9;55.9 15.9t29.0;29.1 -21.li32.9;32.9 14.8i37.4;37.5 I BY-02(C) Stillman Valley Lab Code BYAP-4029 BYAP-4141 BYAP-4257 BYAP-8305 Volume 3702 3948 3566 3721 Mn-54 -6.317.1;7.1 -1.716.7;6.7 -2.716.0;6.0 -8.116.3;6.3 Fe-59 -1.4i1.4;1.4 -9.2i10.4;10.4 3.6i2.8;2.8 -10.7i19.8;19.8 E Co-58 8.7i10.0;10.0 -3.617.0;7.0 5.015.4;5.4 -4.115.9;5.9 L Co-60 -0.5i0.8;0.8 -3.4i3.9;3.9 8.31135;135 3.Si5.1;5.1 Zn-65 -8.4i13.5;13.5 -10.3i9.7;9.9 3.7i12.9;12.9 6.li6.9;6.9 Zr-Nb-95 -17.7i24.8;24.8 -1.818.0;8.0 9.5i9.3;9.3 3.1113.9;13.9 ( Cs-134 0.5141.1;41.1 0.917.6;7.6 5.li10.2;10.2 -1.617.3;7.3 Cs-137 4.418.7;8.7 1.415.4;5.4 0.314.6;4.6 -0.916.3;6.3 Ba-La-140 14.7A61.3;61.3 9.4122.6;22.7 11.6i13.0;13.0 -58.2i41.9;43.2 [ [ 103

O O BYRON Table 2. Airborne Particulates Collection: Quarterly composites of weekly collections Required LLD: 0.05 pCi/m3 for Cs-134 and 0.06 pCi/m3 or Cs-137 and f 3 0.01 pCi/m for all other gamma emitters E Units: 10-4 pCi/m3 5 Sample Description and Concentration BY-03 Nearsite - East 1994 E Collection Period 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. E Lab Code BYAP-4030 BYAP-4142 BYAP-4258 BYAP-8306 I! Volume 3664 3903 3533 3709 i Mn-54 -1.617.9; '.9 -4.4i6.5;6.5 -5.li6.8;6.8 -5.317.6;7.6 Fe-59 24.8i22.3;22.3 -15.5i28.9;29.0 19.4i72.2;72.2 -8.8126.5;26.5 Co-58 -2.918.0;8.0 -2.718.7;8.7 6.8i6.0;6.0 -2.0i7.1:7.1 Co-60 -10.3i123;123 6.2i27.7;27.7 -8.417.0;7.2 -4.5111.0;11.0 Zn-65 2.7i12.6;12.6 1.9117.3;17.3 -2.8113.8;13.8 -20.1122.2;22.2 Zr-Nb-95 1.4i3.9;3.9 5.6112.9;12.9 5.0i33.3;33.3 3.4i21.4;21.4 Cs-134 3.Si4.4;4.4 -8.9i29.7;29.7 9.0i43.2;43.2 6.2i8.6;8.6 Cs-137 7.6i7.1;7.1 3.2i7.2;7.2 0.5i7.1;7.1 0.9i9.1;9.1 Ba-La-140 -8.4i28.3;28.3 21.6i25.5;25.8 44.8128.7;29.8 -29.8i48.3;48.6 BY-04 Pavnes Point Lab Code BYAP-4031 BYAP-4143 BYAP-4259 BYAP-8307 Volume 3710 3890 3526 3716 Mn-54 -0.4i6.1;6.1 -3. li7.5i7.5 4.0i5.4;5.4 4.2i4.2;4.2 Fe-59 21.3131.5;31.5 18.2i46.9;47.0 -1.2ill.9;11.9 -5.1 12.1;12.1 Co-58 8.li10.2;10.2 1.217.9;7.9 1.819.2;9.2 3.7i4.7;4.7 Co-60 -1.11.5;1.5 2.9158.6;58.6 5.li8.0;8.0 -3.4i4.3;4.3 Zn-65 6.617.5;7.5 4.8110.6;10.6 0.9114.8;14.8 -5.3i9.1;9.1 Zr-Nb-95 -1.8i6.7;6.7 -6.7132.2;32.2 -14.4il7.3;17.3 -0.319.1;9.1 Cs-134 3.815.5;5.5 -3.014.6;4.6 2.6i4.6;4.6 0.215.0;5.0 Cs-137 1.7t7.3;7.3 8.315.3;5.5 1.li7.7;7.7 1.Si4.0;4.0 Ba-La-140 -43.7175.1;75.1 -17.9150.6;50.7 -83.71136;136 33.5i26.1;26.8 104 =

BYRON Table 2. Airborne Particulates Collection: Quarterly composites of weekly collections 0.05 pCi/m3 or Cs-134 and 0.06 pCi/m3 or Cs-137 and Required LLD: f f 3 0.01 pCi/m for all other gamma emitters Units: 10-4 pCi/m3 Sample Description and Concentration BY-05 Nearsite - South 1994 Collection Period 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Lab Code BYAP-4032 BYAP-4144 BYAP-4260 BYAP-8308 Volume 3715 3904 3543 3727 Mn-54 0.415.5;5.5 -1.3i6.5;6.5 -2.816.7;6.7 3.313.3;3.3 Fe-59 10.4i13.3;13.3 14.2il5.1;15.3 6.li11.3;11.3 7.3i12.0;12.0 Co-58 -2.616.7;6.7 2.4i6.1;6.1 4.8i7.5;7.5 1.215.3;5.3 Co-60 7.li9.3;9.3 -1.9i18.6;18.6 -6.5i11.8;11.8 0.3i5.6;5.6 I Zn-65 -7.5t10.5;10.5 -5.8115.9;15.9 1.9i11.9;11.9 -0.5t9.8;9.8 Zr-Nb-95 0.5i0.9;0.9 -8.2116.0;16.1 3.8i18.5 18.5 3.8110.4;10.4 Cs-134 1.0il.6;1.6 -7.3i7.8;7.9 -8.6117.3;17.3 0.4i4.6;4.6 Cs-137 -0.6i4.7;4.7 0.915.6,5.6 -6.9i7.7;7.7 -3.313.7;3.7 I Ba-La-140 13.9165.3;65.3 7.7i9.8;9.9 4.3i6.8;6.8 34.0i25.1;25.8 BY-06 Oregon Lab Code BYAP-4033 BYAP-4145 BYAP-4261 BYAP-8309 Volume 3773 3899 3541 3718 l Mn-54 -1.211.0;1.0 7.2i5.5;5.6 -3.0i7.2;7.2 -0.7i5.0;5.0 Fe-59 31.610.6;5.6 7.812.3;2.7 -3.6125.2;25.2 -1.6113.6;13.6 Co-58 -3.0il2.1;12.1 -0.4i6.5;6.5 0.317.3;7.3 -0.315.7;5.7 Co-60 2.4111.3;11.3 -4.313.4;3.5 0.4i62.2;62.2 0.615.2;5.2 Zn-65 -4.3i23.7;23.7 0.li9.3;9.3 13.li9.7;10.0 -3.6i9.4;9.4 Zr-Nb-95 -4.0i62.2;62.2 0.310.5;0.5 -4.5i255;255 -5.8i10.6;10.6 Cs-134 8.2il7.3;17.3 -2.li2.3;2.3 2.8i3.0;3.0 -0.5i4.5;4.5 Cs-137 -6.6i7.7;7.7 2.716.5;6.5 6.616.6;6.6 -4.0i4.8;4.8 Ba 15.3142.0;42.0 -16.3152.8;52.9 18.3i75.3;75.3 0.9i21.1;21.1 _-La-14 0 105

00 BYRON Table 2. Airborne Particulates Collection: Quarterly composites of weekly collections 0.05 pCi/m3 or Cs-134 and 0.06 pCi/m3 or Cs-137 and Required LLD: f f 0.01 pCi/m for all other gamma emitters I 3 Units: 10-4 pCi/m3 Sample Description and Concentration BY-07 (C) Mt. Morris l 1994 ,i Collection Period 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Lab Code BYAP-4034 BYAP-4146 BYAP-4262 BYAP 0310 I Volume 3587 3881 3545 3639 l Mn-54 0.3i4.5;4.5 -1.416.5;6.5 5.316.4;6.4 -1,313.7;3.7 Fe-59 -10.6111.2;11.2 -18.3i38.0;38.1 9.7i8.7;8.7 0.5i12.6;12.6 Co-58 -0.2i4.5;4.5 4.3i6.7;6.7 9.317.6;7.6 0.7i4.5;4.5 i Co-60 3.0i7.4;7.4 -5.319.8;9.8 6.0il5.6;15.6 1.6i4.0;4.0 Zn-65 -6.2i7.2;7.2 -1.9111.7;11.7 -0.9118.6;18.6 1.319.9;9.9 Zr-Nb-95 1.9i4.3;4.3 2.7i3.0;3.0 -17.2i23.0;23.0 -6.3i10.4;10.4 Cs-134 0.911.4;1.4 -0.310.7;0.7 -9.lil2.0;12.0 -0.314.5;4.5 Cs-137 -0.7i0.4;0.4 1.416.4;6.4 8.416.9;6.9 0.li4.6;4.6 Ba-La-140 14.5i120;120 -50.5i54.5;55.2 18.3i16.1;16.4 -29.li30.8;31.2 BY-08 (C) Leaf River Lab Code BYAP-4035 BYAP-4147 BYAP-4263 BYAP-8311 Volume 3727 3932 3560 3720 Mn-54 -0.4i4.0;4.0 3.3i6.0;6.0 -2.7i6.0;6.0 -2.3i5.2;5.2 I Fe-59 -7.0i73.2;73.2 -3.9163.7;63.7 -1.213.2;3.2 10.9116.6;16.6 l Co-58 -0.515.0;5.0 1.4i6.9;6.9 3.818.0;8.0 3.916.6;6.6 Co-60 -2.0i14.0;14.0 2.8i27.7;27.7 0.919.0;9.0 4.4i5.7;5.7 Zn-65 -1.019.6;9.6 -14.4i15.8;16.0 15.9113.7;13.7 -1.0ill.4;11.4 Zr-Nb-95 -1.614.0;4.0 -7.919.5;9.6 -8.0181.9;81.9 1.8110.2;10.2 Cs-134 -1.213.2;3.2 -6.2i32.9;32.9 7.4i9.4;9.4 4.2i6.1;6.1 Cs-137 1.4i4.1;4.1 -5.216.0;6.1 -0.217.4;7.4 1.915.6,5.6 Ba-La-140 -36.0133.8;33.8 30.7157.2;57.5 -29.0i16.8;17.6 -12.9133.3;33.4 1% 5

BYRON Table 2. Airborne Particulates Collection: Quarterly composites of weekly collections Required LLD: 0.05 pCi/m3 for Cs-134 and 0.06 pCi/m3for Cs-137 and 0.01 pCi/m3 for all other gamma emitters Units: 10-4 pCi/m3 Sample Description and Concentration BY-21 Byron Nearsite N 1994 Collection Period 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Lab Code BYAP-4036 BYAP-4148 BYAP-4264 BYAP-8312 Volume 3722 3883 3499 3709 Mn-54 3.9i6.2;6.2 2.6i6.0;6.0 -6.0i7.3;7.3 -0.414.3;4.3 Fe-59 -3.9f.21.4;21.4 -5.2i11.5;11.5 -4.9i3.6;3.7 6.0i7.2;7.2 Co-58 -0.316.9;6.9 7.117.3;7.4 3.8i8.2;8.2 -2.314.6;4.6 Co-60 -2.913.3;3.3 -3.314.2;4.2 1.9i2.4;2.4 -3.614.1;4.1 I Zn-65 -2.8i14.2;14.2 10.7f17.5;17.6 2.8t15.4;15.4 -0.5i8.8;8.8 Zr-Nb-95 -6.3i44.2;44.2 -4.8111.8;11.8 13.3i86.2;86.2 8.418.9;8.9 Cs-134 -2.8i19.6;19.6 -3.213.5;3.5 2.2i4.0;4.0 1.214.4;4.4 Cs-137 -0.2i5.3;5.3 -2.2i7.2;7.2 0.3i8.1;8.1 -0.3i4.3;4.3 I Ba-La-140 -30.0148.0;48.0 31.2i31.2;31.7 -7.7i10.1;10.1 -15.6116.2;16.4 BY-22 Byron Nearsite ESE Lab Code BYAP-4037 BYAP-4149 BYAP-4265 BYAP-8313 Volume 3720 3608 3530 3724 Mn-54 -1.813.3;3.3 -1.4i7.0;7.0 0.li6.7;6.7 3.li5.0;5.0 Fe-59 2.8121.2;21.2 11.319.5;9.7 1.2i2.8;2.8 2.9112.7;12.7 Co-58 1.2i4.4;4.4 4.518.2;8.2 9.516.6;6.6 -1.315.2;5.2 I Co-60 0.6i2.0;2.0 -3.6i2.7;2.8 -5.li3.8;3.8 3.9i4.1;4.1 Zn-65 3.318.6;8.6 -10.Si9.32;9.4 -0.9i14.3;14.3 4.314.9;4.9 Zr-Nb-95 2.016.3;6.3 14.5151.9;51.9 -1.312.2;2.2 -4.5111.5;11.5 Cs-134 2.013.3;3.3 2.011.9;1.9 -4.915.5;5.5 1.li5.6;5.6 Cs-137 2.li3.5;3.5 -1.918.9;8.9 1.916.8;6.8 -4.2i4.8;4.8 Ba-La-140 -19.0i135;135 -37.6149.7;50.1 26.2i33.5;33.5 45.4i33.6;34.6 I 107 I

00 BYRON Table 2. Airborne Particulates Collection: Quarterly composites of weekly collections Required LLD: 0.05 pCi/m3 for Cs-134 and 0.06 pCi/m3for Cs-137 and 0.01 pCi/m3 for all other gamma emitters Units: 10-4 pCi/m3 Sample Description and Concentration BY-23 Byron Nearsite S l 1994 Collection Period 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. I Lab Code BYAP-4038 BYAP-4150 BYAP-4266 BYAP-8314 Volume 3729 3908 3540 3565 Mn-54 0.74.0;4.0 5.4i7.2;7.3 2.6i5.0;5.0 2.9i7.2;7.2 Fe-59 -5.7i8.0;8.0 3.9i6.1;6.1 3.7i6.8;6.8 30.5i25.0;25.6 Co-58 0.6i6.2;6.2 -1.5i7.2;7.2 -3.518.2;8.2 -1.6i8.6;8.6 Co-60 -1.0122.9;22.9 4.7i4.6;4.7 -2.3i37.8;37.8 0.918.2;8.2 Zn-65 3.4111.4;11.4 2.9115.6;15.6 -0.9114.3;14.3 0.3il7.9;17.9 Zr-Nb-95 7.6i18.4;18.4 -6.4 17.4;17.4 3.6i6.7;6.7 -13.4i18.0;18.0 Cs-134 2.lil.7;1.7 -8.217.0;7.2 -3.3t7.6;7.6 2.8i6.4;6.4 g Cs-137 0.4i4.5;4.5 0.4fl.0;1.0 -4.4i5.5;5.5 1.7i6.9;6.9 g Ba-La-140 -35.li82.2;82.2 -2.616.1;6.1 -21.8i156;156 -33.0iS9.4;59.7 BY-24 Byron Nearsite SW l Lab Code BYAP-4039 BYAP-4151 BYAP-4267 BYAP-8315 Volume 3696 3824 3543 3709 Mn-54 -5.616.5;6.5 4.215.6;5.6 -3.4i5.8;5.8 -1.6i6.2;6.2 Fe-59 5.7 11.0;11.0 6.6i14.5;14.5 9.8i22.2;22.2 9.6i19.7;19.7 Co-58 6.2i7.4;7.4 -5.316.4;6.5 -5.5i9.3;9.3 -0.319.4;9.4 Co-60 -1.8141.9;41.9 -7.3i7.1;7.2 7.0i9.2;9.2 2.8i7.0;7.0 Zn-65 19.5118.3;18.3 -23.7116.6;17.1 13.2i9.7;9.7 -4.0i13.3;13.3 Zr-Nb-95 -9.li11.5;11.5 16.3i16.6;16.9 14.91525;525 1.7i11.8;11.8 g Cs-134 -2.4i21.0;21.0 7.9i26.5;26.5 3.213.2;3.2 0.Si6.6;6.6 g Cs-137 -3.Si8.1;8.1 3.0i5.5;5.5 2.8i5.9;5.9 -0.26.2;6.2 Ba-La-140 79.8i67.0;68.0 -2.714.4;4.4 39.4i102;102 34.8tS4.3;54.7 108 g a

I BYRON I Table 3. Milk Collection: Semimonthly-May through October I Monthly -November through April Required LLD: 1.0 pCi/t., for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma I emitters Units: pCi/L I Sample Description and Concentration BY-20 K. Reeverts Dairy Farm Date Collected 01-03-94 02-07-94 03-07-94 Lab Code BYMI-0161 BYMI-245 BYMI-0315 1-131 0.04i0.23;0.23 -0.04i0.12;0.12 0.1910.23;0.23 Mn-54 1.112.5;2.5 2.2i2.8;2.8 -0.4i3.9;3.9 I Fe-59 0.116.0;6.0 1.416.0;6.0 -10.li6.4;6.4 Co-58 -0.3i2.7;2.7 0.612.2;2.2 -0.3i3.8;3.8 Co-60 1.9i2.8;2.8 -0.7i4.0;4.0 1.6i2.0;2.0 I Zn-65 -4.416.5;6.5 -4.2i5.4;5.4 -7.1110.0;10.0 Zr-Nb-95 -0.3i4.8;4.8 1.214.6;4.6 0.513.1;3.1 Cs-134 -1.912.6;2.6 0.7i2.9;2.9 0.311.1;1.1 Cs-137 -0.8i2.8;2.8 2.5i2.9;2.9 1.414.3;4.3 I Ba-La-140 1.913.2;3.2 -2.313.2;3.2 3.2il7.8;17.8 Date Collected 04-04-94 05-07-94 05-21-94 Lab Code BYMI-0136 BYMI-0884 BYMI 1361 1-131 0.0310.21;0.21 0.1310.24;0.24 -0.0210.10;0.10 Mn-54 -5.015.0;5.0 1.32.9;2.9 0.8i2.3;2.3 Fe-59 -8.1115.2;15.2 -2.8i6.1;6.1 4.015.6;5.6 Co-58 0.714.2;4.2 -0.512.5;2.5 0.512.2;2.2 Co-60 2.li67.5;67.5 -1.2i3.9;3.9 -1.li3.0;3.0 Zn-65 1.219.6;9.6 -2.317.0;7.0 -2.9i6.0;6.0 Zr-Nb-95 0.9i12.2;12.2 -1.015.0;5.0 3.314.5;4.5 Cs-134 0.4f3.0;3.0 -0.713.3;3.3 -0.4i2.6;2.6 Cs-137 -0.7i5.3;5.3 1.2i3.4;3.4 1.012.8;2.8 I Ba-La-140 -8.7152.;52.2 0.811.2;1.2 -3.213.1;3.1 109 I

U C BYRON Table 3. Milk (continued) Collection: Semimonthly -May through October Monthly-November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-20 K. Reeverts Dairy Farm Date Collected 06-04-94 06-18-94 07-02-94 Lab Code BYMI-1808 BYMI-2201 BYMI-2664 g E 1-131 0.100i.21;0.21 0.0410.12;0.12 0.15i0.15;0.15 Mn-54 2.314.8;4.8 0.li3.0;3.0 0.712.1;2.1 Fe-59 -1.015.5;55 -3.417.9;7.9 -3.li5.5;5.5 Co-58 -7.814.7;4.8 1.612.8;2.8 -1.512.3;2.3 Co-60 -4.215.9;5.9 3.2i4.2;4.2 -0.7t3.3;3.3 Zn-65 -8.9112.3;12.3 -6.419.3;9.3 4.7i5.9;5.9 Zr-Nb-95 0.5i7.2;7.2 -3.015.5;5.5 -2.2i4.1;4.1 Cs-134 1.415.0;5.0 1.213.5;3.5 -0.4i2.4;2.4 Cs-137 1.3i4.9;4.9 -1.5i3.6;3.6 2.212.5;2.5 Ba-La-140 -2.915.4;5.4 -0.414.2;4.2 -1.712.6;2.6 Date Collected 07-11-94 08-02-94 08-16-94 Lab Code BYMI-3018 BYMI-3592 BYMI-4015 1-131 -0.05i0.13;0.13 0.0310.13;0.13 0.0710.12;0.12 Mn-54 -0.413.5;3.5 1.0i?.8;2.8 0.3i3.5;3.5 Fe-59 3.4 8.7;8.7 -3.11o.2;6.2 -0.318.4;8.4 Co-58 2.813.6;3.6 0.113.1;3.1 -0.5f3.6;3.6 Co-60 2.1f4.5;4.5 1.7f3.3;3.3 -1.214.3;4.3 Zn-65 -5.li8.2;8.2 2.7i6.6;6.6 -4.418.1;8.1 Zr-Nb-95 -1.416.9;6.9 3.415.6;5.6 -3.015.6;5.6 Cs-134 -1.3i4.3;4.3 -0.713.1;3.1 0.213.4;3.4 Cs-137 2.2i3.5;3.5 0.413.0:3.0 0.7i3.5;3.5 Ba-La-140 3.318.4;8.4 4.316.3;6.3 -0.2i4.4;4.4 110 .E

F BYRON Table 3. Milk (continued) Collection: Semimonthly-May through October 7 Monthly-November through April L Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emit ters b Units: pCi/L { Sample Description and Concentration BY-20 K. Reeverts Dairy Farm Date Collected 09-06-94 09-20-94 10-04-94 Lab Code BYMI-4521 BYMI-4916 BYMI-5525 I-131 0.0210.18;0.18 0.0510.12;0.12 0.00io.21;0.21 Mn-54 -0.712.2;2.2 -0.413.1;3.1 0.112.8;2.8 Fe-59 6.014.7;4.7 4.417.0;7.0 0.67.7;7.7 Co-58 -0.912.0;2.0 -0.613.4;3.4 -1.3i2.9;2.9 Co-60 -1.5i3.2;3.2 -1.314.7;4.7 -2.6i3.6;3.6 Zn-65 0.315.4;5.4 -4.418.0;8.0 -3.li7.5;7.5 { Zr-Nb-95 2.4i4.0;4.0 -2.9i5.8;5.8 -1.815.4;5.4 Cs-134 0.2i2.5;2.5 -1.814.1;4.1 -0.7i3.3;3.3 Cs-137 1.012.4;2.4 3.413.4;3.4 1.613.6;3.6 Ba-La-140 -1.7tl.9;1.9 -0.8f3.7;3.7 -3.614.8;4.8 Date Collected 10-18-94 11-01-94 12-06-94 Lab Code BYMI-6038 BYMI-6427 BYMI-7424 I-131 -0.2110.25;0.25 0.0710.21;0.21 -0.1010.21;0.21 Mn-54 0.312.2;2.2 -0.2i3.3;3.3 -0.li2.9;2.9 Fe-59 0.415.6;5.6 1.218.0;8.0 -6.li6.5;6.5 Co-58 0.612.3;2.3 -0.613.5;3.5 -1.113.3;3.3 Co-60 0.2i3.3;3.3 -2.915.0;5.0 -1.614.0;4.0 Zn-65 5.316.0;6.0 -2.2i7.3;7.3 -2.6i7.0;7.0 Zr-Nb-95 -1.1f4.3;4.3 0.415.6;5.6 -2.6i4.6;4.6 Cs-134 1.612.5;2.5 -0.413.6;3.6 -0.2i2.9;2.9 Cs-137 0.112.6;2.6 -0.813.6;3.6 -2.013.0;3.0 Ba-La-140 -0.812.8;2.8 -1.211.8;1.8 1.913.5;3.5 111

E= BYRON Table 3. Milk (continued) Collection: Semimonthly - May through October Monthly - November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-26(C) Glen Hazzard's Dairv Date Collected 01-03-94 02-07-94 03-07-94 Lab Code BYMI-0162 BYMI-0246 BYMI-0316 I-131 0.1810.23;0.23 0.09i0.16;0.16 -0.07i0.22;0.22 Mn-54 1.2i2.0;2.0 1.0i2.0;2.0 1.2i3.3;3.3 Fe-59 5.4i4.6;4.6 -0.614.9;4.9 -5.li9.0;9.0 Co-58 -0.312.0;2.0 1.2i2.2;2.2 1.213.7;3.7 Co-60 2.212.8;2.8 1.813.0;3.0 -2.8i9.1;9.1 E Zn-65 1.li4.7;4.7 -6.315.5;5.5 2.8i12.4;12.4 5 Zr-Nb-95 -2.li3.6;3.6 -0.813.9;3.9 -3.7i19.1;19.1 Cs-134 -0.211.6;1.6 0.212.3;2.3 -0.4i4.9;4.9 Cs-137 0.412.0;2.0 1.0i2.4;2.4 -0.614.0;4.0 Ba-La-140 -0.312.3;2.3 0.6i2.2;2.2 0.715.8;5.8 Date Collected 04-04-94 05-07-94 05-21-94 Lab Code BYMI-0137 BYMI-0885 BYMI-1362 I-131 0.0410.19;0.19 -0.0110.21;0.21 -0.11i0.15;0.15 Mn-54 0.li2.2;2.2 0.813.2;3.2 0.112.4;2.4 Fe-59 -2.88.1;8.1 1.814.1;4.1 0.8i9.2;9.2 Co-58 -0.8i2.1;2.1 2.013.2;3.2 0.5i2.4;2.4 Co-60 -1.li5.0;5.0 -0.711.5;1.5 2.8i4.1;4.1 E Zn-65 -2.815.2;5.2 2.Si7.7;7.7 -4.215.6;5.6 3 Zr-Nb-95 -2.0i3.6;3.6 0.211.9;1.9 0.2i0.6;0.6 Cs-134 1.311.9;1.9 0.210.3;0.3 -0.110.1;0.1 Cs-137 0.112.4;2.4 -0.813.6;3.6 0.112.8;2.8 Ba-La-140 -1.6i8.8;8.8 1.111.6;1.6 -0.615.0;5.0 I 112 m

c BYRON Table 3. Milk (continued) Collection: Semimonthly - May through October Monthly - November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma I emitters Units: pCi/L Sample Description and Concentration BY-26(C) Glen Hazzard's Dairv Date Collected 06-04-94 06-18-94 07-02-94 t I Lab Code BYMI-1809 BYMI-2202 BYMI-2665 I-131 0.1110.17;0.17 0.0810.13;0.13 -0.03t0.17;0.17 Mn-54 0.812.4;2.4 1.7i2.2;2.2 0.212.6;2.6 Fe-59 1.615.6;5.6 1.715.3;5.3 0.216.7;6.7 Co-58 -0.5i2.7;2.7 1.312.2;2.2 -0.9i2.7;2.7 j Co-60 0.413.3;3.3 -0.6i2.9;2.9 -0.2i3.3;3.3 Zn-65 -0.416.0;6.0 -2.315.3;5.3 -3.3i6.4;6.4 Zr-Nb-95 -3.014.6;4.6 1.44.1;4.1 0.614.7;4.7 g Cs-134 1.0i2.4;2.4 1.4i2.4;2.4 -0.7i3.0;3.0 Cs-137 0.812.8;2.8 0.112.5;2.5 1.3i2.8;2.8 Ba-La-140 1.112.4;2.4 2.3i2.6;2.6 -5.813.5;3.7 E Date Collected 07-11-94 08-02-94 08-16-94 Lab Code BYMI-3019 BYMI-3593 BYMI-4016,7 1-131 0.0810.14;0.14 0.1210.14;0.14 0.10i0.16;0.16 l Mn-54 1.7i2.4;2.4 0.7i3.6;3.6 2.0i2.3;2.3 Fe-59 1.315.9;5.9 3.9 8.0;8.0 1.7i5.0;5.0 l Co-58 -0.3i2.5;2.5 -2.013.8;3.8 0.214.5;4.5 I Co-60 0.li3.8;3.8 -0.7i4.6;4.6 0.0i2.8;2.8 Zn-65 0.717.4;7.4 6.818.0;8.0 -5.215.3;5.3 Zr-Nb-95 -1.815.1;5.1 0.4i5.8;5.8 -0.8i4.3;4.3 Cs-134 0.412.7;2.7 -1.Si3.5;3.5 -0.4i2.6;2.6 ) Cs-137 0.1t2.5;2.5 0.213.6;3.6 1.012.3;2.3 i Ba-La-140 -1.114.0;4.0 2.516.8;6.8 3.3i2.4;2.4 I l 113 L_ --- O

O Ol BYRON Table 3. Milk (continued) Collection: Semimonthly-May through October Monthly-November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-26(C) Glen Hazzard's Dairv Date Collected 09-06-94 09-20-94 10-04-94 Lab Code BYMI-4522 BYMI-4917 BYMI-5526 I-131 0.07i0.17;0.17 0.07i0.14;0.14 -0.0210.16;0.16 Mn-54 1.912.8;2.8 0.9i3.5;3.5 -3.414.2;4.2 Fe-59 7.5i7.5;7.5 -0.3i6.7;6.7 -2.619.3;9.3 Co-58 -2.012.8;2.8 -1.213.7;3.7 -1.04.7;4.7 Co-60 -2.2i4.1;4.1 -2.5f4.4;4.4 1.615.5;5.5 Zn-65 -7.0i8.1;8.1 2.6i7.4;7.4 -6.5i10.6;10.6 Zr-Nb-fb -1.7i4.8;4.8 -2.215.7;5.7 2.8i6.5;6.5 Cs-134 0.4i3.3;3.3 -0.3i3.6;3.6 -0.3i4.4;4.4 Cs-137 -1.2f3.2;3.2 2.013.2;3.2 -3.014.0;4.0 Ba-La-140 4.115.4;3.4 3.8i3.5;3.5 -1.915.9;5.9 I Date Collected 10-18-94 11-01-94 12-06-94 Lab Code BYMI-6039 BYMI-6428 BYMI-7425 I-131 0.2010.25;0.25 0.06i0.16;0.16 -0.0510.23;0.23 Mn-54 2.713.4;3.4 4.213.2;3.2 0.613.4;3.4 Fe-59 -3.418.0;8.0 -0.719.4;9.4 -0.2i6.2;6.2 Co-58 -2.6i3.7;3.7 2.6i4.1;4.1 0.213.0;3.0 g Co-60 -1.514.6;4.6 -0.4i3.9;3.9 -0.414.2;4.2 3 Zn-65 3.3i8.0;8.0 -2.4i9.6;9.6 -1.6i7.7;7.7 Zr-Nb-95 2.216.2;6.2 0.216.6;6.6 -7.li5.7;5.8 Cs-134 0.314.1;4.1 0.813.3;3.3 -1.213.7;3.7 Cs-137 1.413.7;3.7 0.613.8;3.8 0.413.4;3.4 Ba-La-140 -0.215.9;5.9 -2.013.3;3.3 -1.013.7;3.7 114 m

I BYRON I Table 3. Milk (continued) Collection: Semimonthly-May through October Monthly-November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-27 Kenneth Druien Dairy Farm Date Collected 01-03-94 02-07-94 03-07-94 Lab Code BYMI-0163 BYMI-0247 BYMI-0317 I-131 0.09i0.21;0.21 0.10f0.15;0.15 -0.14i0.18;0.18 Mn-54 2.42.4;2.4 -0.712.4;2.4 -0.4i2.2;2.2 Fe-59 -1.5i4.9;4.9 -3.7i6.2;6.2 -1.0i2.3;2.3 Co-58 1.412.7;2.7 -0.912.8;2.8 -0.6i2.3;2.3 Co-60 1.6i3.7;3.7 -2.613.9;3.9 1.9i4.9;4.39 I Zn-65 -1.716.8;6.8 3.7i7.2;7.2 -4.6i5.8;5.8 Zr-Nb-95 -2.313.8;3.8 -1.014.6;4.6 2.2183.2;83.2 Cs-134 -0.5i2.0;2.0 1.4i3.2;3.2 0.9i4.6;4.6 Cs-137 0.7i2.2;2.2 -1.li2.6;2.6 0.li2.5;2.5 I Ba-La-140 1.4i2.7;2.7 0.5il.0;1.0 -1.713.2;3.2 Date Collected 04-04-94 05-07-94 05-21-94 Lab Code BYMI-0138 BYMI-0886 BYMI-1363 I-131 -0.1210.12;0.12 -0.1510.16;0.16 0.0710.12;0.12 Mn-54 -0.812.7;2.7 2.3i4.7;4.7 -1.li2.2;2.2 Fe-59 -0.510.6;0.6 -0.8112.2;12.2 -1.8i6.9;6.9 Co-58 1.112.9;2.9 -1.li5.0;5.0 0.112.1;2.1 Co-60 2.212.6;2.6 -4.6i7.2;7.2 -0.6i4.7;4.7 I Zn-65 0.215.9;5.9 3.9113.3;13.3 -0.315.3;5.3 Zr-Nb-95 -0.3fl.1;1.1 2.li7.8;7.8 0.415.2;5.2 Cs-134 -0.811.8;1.8 3.715.4;5.4 -0.6i12.2;12.2 Cs-137 1.2i3.1;3.1 0.315.0;5.0 1.412.3;2.3 I Ba-La-140 -0.611.4;1.4 1.li5.7;5.7 -0.212.3;2.3 I ,g 115 I

E ha BYRON Table 3. Milk (continued) Collection: Semimonthly-May through October Monthly -November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-27 Kenneth Druien Dairy Farm Date Collected 06-04-94 06-18-94 07-02-94 Lab Code BYMI-1810 BYMI-2203 BYMI-2666 I-131 0.08i0.17;0.17 0.06i0.13;0.13 0.0110.11;0.11 Mn-54 -0.313.0;3.0 1.li2.9;2.9 0.513.7;3.7 Fe-59 0.6i7.4;7.4 -0.416.6;6.6 2.719.9;9.9 Co-58 1.713.3;3.3 0.li2.6;2.6 -1.13.5;3.5 Co-60 2.114.8;4.8 0.2i3.7;3.7 4.8i4.7;4.7 Zn-65 3.09.3;9.3 -1.06.5;6.5 -3.218.1;8.1 Zr-Nb-95 7.016.5;6.5 -2.014.6;4.6 -1.416.0;6.0 Cs-134 -0.4i3.6;3.6 2.4i3.3;3.3 -1.li4.0;4.0 Cs-137 1.8i3.7;3.7 2.013.2;3.2 -2.613.9;3.9 Ba-La-140 -3.112.6;2.6 0.6i3.0;3.0 0.810.9;0.9 Date Collected 07-11-94 08-02-94 08-16-94 Lab Code BYMI-3020 BYMI-3594 BYMI-4018 I-131 -0.06i0.13;0.13 0.22 0.23;0.23 0.09i0.11;0.11 l Mn-54 1.8i3.1;3.1 4.3i4.7;4.7 -0.914.3;4.3 i Fe-59 4.517.2;7.2 -7.318.6;8.6 3.1110.6;10.6 Co-58 -1.413.5;3.5 -4.415.0;5.0 -3.4i4.3;4.3 Co-60 2.6i4.8;4.8 -2.515.7;5.7 -0.414.9;4.9 3 Zn-65 -2.418.8;8.8 -6.li9.2;9.2 -3.7i10.8;10.8 3 Zr-Nb-95 -0.716.0;6.0 -2.li7.8;7.8 -2.9i7.1;7.1 l Cs-134 -0.913.5;3.5 0.414.0;4.0 3.914.6;4.6 l Cs-137 0.8i3.5;3.5 1.914.4;4.4 0.114.2;4.2 Ba-La-140 -5.816.3;6.3 -1.416.5;6.5 0.116.7;6.7 1 116 l

=

l

BYRON Table 3. Milk (continued) Collection: Semimonthly-May through October p Monthly-November through April L Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration s ( BY-27 Kenneth Druien Dairy Farm Date Collected 09-06-94 09-20-94 10-04-94 i l Lab Code BYMI-4523 BYMI-4918 BYMI-5527,8 1 { I-131 -0.0410.17;0.17 0.03i0.13;0.13 -0.0210.13;0.13 Mn-54 1.714.1;4.1 -1.512.7;2.7 0.5i2.0;2.0 Fe-59 5.619.6;9.6 -2.li6.1;6.1 -3.li5.1;5.1 [ Co-58 -0.114.3;4.3 -0.812.7;2.7 0.412.0;2.0 Co-60 0.815.7;5.7 -0.2i3.3;3.3 -0.li2.5;2.5 Zn-65 -6.4i10.3;10.3 -2.8i6.3;6.3 -0.4i4.9;4.9 [ Zr-Nb-95 0.3i 0.915.0;5.0 -0.6i3.6;3.6 Cs-134 3.114.2;4.2 -3.313,3;3.3 1.0i2.2;2.2 Cs-137 3.4i4.1;4.1 0.3i3.1;3.1 1.3i2.1;2.1 Ba-La-140 2.414.4;4.4 -1.512.7;2.7 -2.2i3.3;3.3 { Date Collected 10-18-94 11-01-94 12-06-94 Lab Code BYMI-6040 BYMI-6429 BYMI-7426 I-131 0.0410.19;0.19 0.1410.24;0.24 -0.02i0.20;0.20 Mn-54 -0.2i4.9;4.9 -3.015.0;5.0 2.4i3.0;3.0 Fe-59 1.6110.4;10.4 -6.4i11.8;11.8 -2.5i7.3;7.3 Co-58 1.215.1;5.1 -1.5i4.7;4.7 1.3i2.9;2.9 Co-60 2.415.6;5.6 -0.415.2;5.2 -1.314.4;4.4 Zn-65 4.2111.8;11.8 -3.6i12.1;12.1 2.018.2;8.2 Zr-Nb-95 -1.318.0;8.0 -5.917.7;7.7 2.9i5.3;5.3 Cs-134 0.2i4.1:4.1 1.915.0;5.0 2.2i3.3;3.3 Cs-137 -1.4i4.3;4.3 -1.8i4.9;4.9 -0.413.4;3.4 Ba-La-140 -2.317.0;7.0 -2.Si8.1;8.1 2.2i3.9;3.9 117 -A

O. O BYRON Table 3. Milk (continued) Collection: Semimonthly-May through October l Monthly-November through April Required LLD: 1.0 pCi/L for I 131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other ganuna emitters Units: pCi/L I Sample Description and Concentration BYSP-28 Duane Camling Dairy Farm Date Collected 01-03-94 02-07-94 03-07-94 Lab Code BYMI-0164 BYMI-0248 BYMI-0318 I131 0.0210.17;0.17 -0.0210.12;0.12 0.0610.20;0.20 Mn-542.012.7;2.7 -1.2i2.4;2.4 0.911.8;1.8 1.012.5;2.5 Fe-59 0.9i2.1;2.1 -2.4i4.5;4.5 -5.0166.6;66.6 Co-58 0.712.7;2.7 -0.6il.8;1.8 -0.86.0;6.0 Co-60 -1.2i3.6;3.6 -0.412.8;2.8 0.912.1;2.1 Zn-65 -0.917.6;7.6 -3.415.3;5.3 5.717.1;7.1 3 Zr-Nb-95 -2.414.7;4.7 0.613.2;3.2 2.5i19.9;19.9 5 Cs-134 -1.312.5;2.5 -1.0i2.2;2.2 -1.012.8;2.8 Cs-137 0.0i3.4;3.4 0.li2.2;2.2 -1.3i3.2;3.2 Ba-La-140 1.113.0;3.0 1.812.0;2.0 1.316.7;6.7 Date Collected 04-04-94 05-07-94 05-21-94 Lab Code BYMI-0139 BYMI-0887 BYMI-1364 1-131 0.11i0.20;0.20 0.0210.21;0.21 -0.07i0.10;0.10 Mn-54 -1.212.2;2.2 0.Si2.2;2.2 -0.6i4.1;4.1 Fe-59 3.112.9;2.9 1.412.2;2.2 -5.219.3;9.3 Co-58 1.112 1;2.1 -0.812.2;2.2 0.213.8;3.8 Co-60 -3.3124.8;24.8 0.5tl.9;1.9 1.6i5.4;5.4 Zn-65 -0.815.2;5.2 -2.515.6;5.6 0.7110.0;10.0 g Zr-Nb-95 -1.3;1.2;1.2 1.014.2;4.2 -3.016.6;6.6 E Cs-134 -0.411.0;1.0 0.7il.1;1.1 3.6i4.8;4.8 Cs-137 -0.3t2.4;2.4 1.212.6;2.6 -0.814.2;4.2 Ba-La-140 -1.818.5;8.5 -0.110.3;0.3 1.015.6;5.6 118 s

{ BYRON f: Table 3. Milk (continued) l Collection: Semimonthly-May through October Monthly-November through April (. Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BYSP-28 Duane Camline Dairy Farm ( Date Collected 06-04-94 06-18-94 07-02-94 Lab Code BYMI-1811 BYMI-2204 BYMI-2667 I-131 -0.0910.16;0.16 0.03i0.12;0.12 0.0910.15;0.15 Mn-54 0.412.3;2.3 -1.014.2;4.2 0.913.2;3.2 Fe-59 0.2i4.6;4.6 -4.4i9.3;9.3 -4.0i8.1;8.1 Co-58 0.li2.1;2.1 -0.5i3.5;3.5 -1.913.1;3.1 Co-60 -0.912.9;2.9 0.li5.6;5.6 1.0i4.5;4.5 Zn-65 -0.2i4.9;4.9 -15.li10.6;10.8 2.918.4;8.4 Zr-Nb-95 5.4t3.8;3.8 -5.317.4;7.4 1.116.8;6.8 [ Cs-134 -0.512.5;2.5 1.6i4.6;4.6 -1.4i4.2;4.2 Cs-137 -1.7i2.5;2.5 1.914.6;4.6 1.213.5;3.5 Ba-La-140 -2.112.4;2.4 -6.815.1;5.1 2.512.5;2.5 [ Date Collected 07-11-94 08-02-94 08-16-94 [ Lab Code BYMI-3021 BYMI-3595 BYMI-4019 l-131 0.1210.18;0.18 0.1010.20;0.20 0.07i0.12;0.12 Mn-54 -1.2i3.8;3.8 2.012.9;2.9 -0.9i3.0;3.0 Fe-59 1.6i9.9;9.9 4.818.7;8.7 6.116.9;6.9 Co-58 -0.5i4.0;4.0 0.513.2;3.2 2.4i2.5;2.5 [ i Co-60 1.2i4.6;4.6 1.714.8;4.8 3.2i4.1;4.1 Zn-65 -9.4i10.2;10.2 -1.0i9.1;9.1 2.4i6.5;6.5 Zr-Nb-95 -1.7i7.6;7.6 -3.9i5.7;5.7 0.9i5.7;5.7 (. Cs-134 -0.5i4.2;4.2 1.li3.6;3.6 1.413.2;3.2 Cs-137 1.0i4.5;4.5 0.8i3.2;3.2 0.li3.4;3.4 Ba-La-140 1.315.8;5.8 -3.6f4.1;4.1 0.813.7;3.7 { ( 119

O O BYRON Table 3. Milk (continued) Collection: Semimonthly - May through October Monthly-November through April Required LLD. 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; g 18 pCi/L for Cs-137; 20 pCi/L for all other gamma g emitters Units: pCi/L Sample Description and Concentration I BYSP-28 Duane Camling Dairy Farm Date Collected 09-06-94 09-20-94 10-04-94 Lab Code BYMI-4524 BYMI-4919 BYMI-5529 I-131 -0.0910.16;0.16 0.04i0.18;0.18 -0.08i0.18;0.18 Mn-54 1.213.2;3.2 2.112.8;2.8 1.5i3.0;3.0 Fe-59 1.817.2;7.2 1.4i7.3;7.3 -2.518.1;8.1 Co-58 -0.713.2;3.2 -3.213.0;3.0 -0.4i2.9;2.9 g Co-60 1.03.9;3.9 0.913.8;3.8 0.714.6;4.6 g Zn-65 -1.7i7.6;7.6 -3.317.6;7.6 -2.018.3;8.3 Zr-Nb-95 2.915.5;5.5 3.3i4.4;4.4 -3.4i5.8;5.8 Cs-134 3.113.8;3.8 -1.8i3.0;3.0 1.0i3.8;3.8 Cs-137 -0.13.7;3.7 3.012.8;2.8 -1.113.4;3.4 Ba-La-140 -0.213.6;3.6 0.413.8;3.8 3.4i5.4;5.4 Date Collected 10-18-94 11-01-94 12-06-94 Lab Code BYMI-6041 BYMI-6430 BYMI-7427 I-131 0.0610.18;0.18 0.0810.19;0.19 0.0210.12;0.12 Mn-54 2.113.1;3.1 -1.513.8;3.8 -0.112.4;2.4 Fe-59 4.0.t8.5;8.5 -3.018.7;8.7 -3.715.9;5.9 Co-58 2.913.7;3.7 -3.713.5;3.5 -2.332.4;2.4 E Co-60 -2.414.1;4.1 0.Si3.8;3.8 0.213.6;3.6 E Zn-65 -4.18.5;8.5 -1.418.8;8.8 -3.615.8;5.8 Zr-Nb-95 3.516.0;6.0 -5.li6.4;6.4 -2.914.0;4.0 Cs-134 -0.4f4.2;4.2 -1.2i3.7;3.7 -0.912.3;2.3 Cs-137 -0.7i3.6;3.6 -1.li3.2;3.2 1.212.8;2.8 Ba-La-140 4.014.0;4.0 -3.815.1;5.1 1.113.8;3.8 I 120 Ea,

I t I l BYRON Table 3. Milk (continued) 'I Collection: Semimonthly -May through October Monthly-November through April l Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters 1 Units: pCi/L Sample Description and Concentration I BY-30 Don Roos Dairv Date Collected 01-03-94 02-07-94 03-07-94 Lab Code BYMI-0165 BYMI-0249 BYMI-0319 I-131 -0.1710.18;0.18 0.0910.15;0.15 0.21i0.23;0.23 Mn-54 -0.812.0;2.0 1.7i3.0;3.0 -2.0i2.4;2.4 I Fe-59 -0.li5.2;5.2 4.5i8.7;8.7 -3.7i4.8;4.8 Co-58 0.511.9;1.9 -1.413.3;3.3 0.6i2.2;2.2 Co-60 1.513.0;3.0 0.3i4.3;4.3 1.213.6;3.6 I Zn-65 -0.4i5.6;5.6 -4.117.7;7.7 -1.9i6.4;6.4 Zr-Nb-95 -1.013.8;3.8 -4.915.8;5.8 2.212.2;2.2 Cs-134 -1.912.1;2.1 0.813.2;3.2 2.011.9;1.9 Cs-137 0.6i2.2;2.2 -1.7i3.6;3.6

1. 9i3.2;3.2 I

Ba-La-140 1.62.0;2.0 -4.417.6;7.6 1.416.2;6.2 Date Collected 04-04-94 05-07-94 05-21-94 Lab Code BYMI-0140 BYMI-0888 BYMI-1365 1-131 0.1510.23;0.23 0.0810.17;0.17 -0.0610.12;0.12 Mn-54 -0.514.5;4.5 0.312.0;2.0 0.312.4;2.4 Fe-59 -9.31149;149 -0.Sil.0;1.0 2.719.2;9.2 Co-58 0.5i3.8;3.8 0.3i2.1;2.1 1.2i2.8;2.8 Co-60 1.713.9;3.9 -1.118.3;8.3 2.li34.7;34.7 I 7.n-65 -0.5i11.6;11.6 0.3f 4.8;4.8 -5.0i6.4;6.4 Zr-Nb-95 -0.812.1;2.1 -0.810.6;0.6 -1.6i9.0;9.0 Cs-134 -1.3i2.9;2.9 0.110.2;0,2 -3.5133.9;33.9 Cs-137 3.114.7;4.7 1.212.4;2.4 0.213.2;3.2 Ba La-140 -2.513.1;3.1 2.313.8;3.8 2.218.0;8.0 I 121

O O BYRON I Table 3. Milk (continued) Collection: Semimonthly-May through October Monthly-November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-30 Don Roos Dairv Date Collected 06-04-94 06-18-94 07-02-94 Lab Code BYMI-1812 BYMI-2205 BYMI-2668 I-131 0.1310.19;0.19 -0.0310.11;0.11 0.0810.13;0.13 Mn-54 1.812.5;2.5 0.712.7;2.7 -0.8i3.5;3.5 Fe-59 0.215.8;5.8 1.417.0;7.0 3.316.8;6.8 Co-58 -1.412.4;2.4 -0.4i3.5;3.5 -1.112.8;2.8 Co-60 1.912.9;2.9 -1.514.0;4.0 4.614.7;4.7 3 Zn-65 -3.616.1;6.1 5.017.5;7.5 1.117.0;7.0 g Zr-Nb-95 0.414.5;4.5 3.4i5.5;5.5 -1.li5.3;5.3 Cs-134 -2.3i2.6;2.6 0.414.0;4.0 -0.612.8;2.8 Cs-137 0.112.8;2.8 2.6i3.3;3.3 2.013.1;3.1 Ba-La-140 0.7i2.2;2.2 -2.313.3;3.3 1.2i3.2;3.2 Date Collected 07-11-94 08-02-94 08-16-94 Lab Code BYMI-3022 BYMI-3596 BYMI-4020 1-131 0.0810.18;0.18 0.1710.22;0.22 -0.04i0.11;0.11 Mn-54 0.913.6;3.6 0.3i3.2;3.2 2.3i4.1;4.1 Fe-59 -0.4i10.5;10.5 2.li9.1;9.1 0.69.1;9.1 Co-58 -0.913.6;3.6 -0.313.4;3.4 0.113.9;3.9 Co-60 -0.814.4;4.4 -3.514.5;4.5 2.114.3;4.3 g Zn-65 -1.519.3;9.3 1.418.5;8.5 -0.419.6;9.6 E Zr-Nb-95 1.9i7.6;7.6 -0.815.7;5.7 -1.0i7.0;7.0 Cs-134 -1.414.6;4.6 -0.813.6;3.6 -1.84.1;4.1 Cs-137 1.613.7;3.7 2.013.6;3.6 0.7i3.7;3.7 Ba-La-140 1.7i8.1;8.1 -1.618.0;8.0 0.815.2;5.2 I 122 m

I BYRON Table 3. Milk (continued) I Collection: Semimonthly -May through October Monthly-November through April Required LLD: 1.0 pCi/L for I-131; 15 pCi/L for Cs-134 and Ba-La-140; I 18 pCi/L for Cs-137; 20 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration I BY-30 Don Roos Dairv I Date Collected 09-06-94 09-20-94 10-04-94 Lab Code BYMI-4525,6 BYMI-4920 BYMI-5530 I-131 0.06f0.18;0.18 0.1510.21;0.21 0.01i0.20;0.20 Mn-54 1.213.3;3.3 0.613.0;3.0 0.513.2;3.2 Fe-59 -0.614.0;4.0 -6.8i7.8;7.8 -3.9i6.6;6.6 Co-58 0.lil.7;1.7 -1.412.8;2.8 -3.6i3.4;3.4 Co-60 2.012.2;2.2 -0.li3.9;3.9 2.013.8;3.8 Zn-65 -0.2i4.4;4.4 -1.318.2;8.2 1.2i7.7;7.7 Zr-Nb-95 -0.6i3.4;3.4 3.6i5.9;5.9 0.4f5.7;5.7 I Cs-134 0.5f2.1;2.1 2.813.4;3.4 -1.712.9;2.9 Cs-137 0.812.0;2.0 1.0i3.2;3.2 4.4i3.4;3.5 Ba-La-140 1.211.2;1.2 -3.114.1;4.1 -0.2i3.4;3.4 I Date Collected 10-18-94 11-01-94 12-06-94 Lab Code BYMI-6042 BYMI-6431 BYMI-7428 I-131 -0.0410.22;0.22 0.06i0.18;0.18 -0.02i0.24;0.24 Mn-54 -0.813.4;3.4 -0.6i2.2;2.2 0.512.0;2.0 Fe-59 -4.0i6.8;6.8 0.215.7;5.7 -2.0i5.3;5.3 Co-58 -0.li3.0;3.0 1.312.5;2.5 -0.4i2.1;2.1 I Co-60 0.7i3.6;3.6 0.213.2;3.2 2.613.1;3.1 Zn-65 0.516.1;6.1 -1.116.0;6.0 -5.715.3;5.3 Zr-Nb-95 -0.9i4.7;4.7 -0.414.5;4.5 -0.814.0;4.0 Cs-134 1.412.9;2.9 -0.1f2.6;2.6 -0.Si2.4;2.4 Cs-137 0.8i3.2;3.2 -1.112.6;2.6 1.4i2.4;2.4 Ba-La-140 -1.5i2.4;2.4 -3.li14.2;14.12 1.3i2.5;2.5 II 123 I

L [ BYRON r' Table 4. Fish, Edible Portions Collection: Three (3) times per year p Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for L Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight I Sample Description and Concentration r L BY-12 Oregon Pool of Rock River. Downstream u Date Collected 05-23-94 05-23-94 05-23-94 [ Lab Code BYF-1420 BYF-1421 BYF-1422 Type Carp Silver Redhorse Carpsucker F L Mn-54 -0.5i.0.8;0.8 -0.3tl.0;1.0 0.1+1.0;1.0 Fe-59 0.li2.3;2.3 1.0i3.4;3.4 1.912.6;2.6 Co-58 0.310.9;0.9 0.011.1;1.1 0.4fl.0;1.0 [ Co-60 0.2il.0;1.0 1.2il.7;1.7 0.6tl.3;1.3 Zn-65 -0.912.1,.2.1 -1.013.0;3.0 -0.812.5;2.5 Zr-Nb-95 0.6fl.5;1.5 -0.4tl.9;1.9 -0.211.8;1.8 F Cs-134 -0.8i0.9;0.9 0.0i0.9;0.9 1.4tl.0;1.0 L Cs-137 -0.510.9;0.9 0.2il.3;1.3 0.lil.0;1.0 Ba-La-140 -2.51.6;1.6 1.9il.7;1.7 -1.8il.9;1.9 Date Collected 05-23-94 05-23-94 07-07-94 [ Lab Code BYF-1423 BYF-1424 BYF-2800 Type Shorthead Redhorse Freshwater Drum Carp r L Mn-54 -0.110.8;0.8 -0.211.1;1.1 0.8il.4;1.4 Fe-59 0.2i0.2;0.2 -2.012.8;2.8 1.913.1;3.1 Co-58 0.3i0.8;0.8 0.4fl.2;1.2 -0.7il.4;1.4 ( Co-60 0.611.3;1.3 0.311.3;1.3 -1.110.9;0.9 Zn-65 1.22.0;2.0 -2.li2.6;2.6 1.813.4;3.4 Zr-Nb-95 0.4 0.3;0.3 0.2i2.2;2.2 0.2i2.4;2.4 [ Cs-134 0.611.4;1.4 0.111.3;1.3 -0.511.5;1.5 Cs-137 0.7io.7;0.7 0.Sil.3;1.3 -0.611.2;1.2 Ba-La-140 -1.914.0;4.0 -1.212.2;2.2 0.li1.4;1.4 [ [ ( 124

0 0 BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration BY-12 Oregon Pool of Rock River. Downstream Date Collected 07-07-94 07-07-94 07-07-94 Lab Code BYF-2801 BYF-2802 BYF-2803 I Type Small Mouth Buffalo Fresh Water Drum Fresh Water Drum Mn-54 -1.2i0.9;0.9 -0.210.9;0.9 0.9il.0;1.0 E Fe-59 1.411.6;1.6 -0.4i2.1;2.1 0.913.0;3.0 E Co-58 0.4to.9;0.9 -0.110.8;0.8 -0.411.3;1.3 Co-60 0.6il.4;1.4 -0.7tl.1;1.1 0.8tl.7;1.7 Zn-65 -1.lf3.1;3.1 -0.6i2.0;2.0 -1.013.6;3.6 Zr-Nb-95 1.9i2.4;2.4 -0 911.2;1.2 2.3i2.0;2.0 Cs-134 -0.2il.2;1.2 0.7io.8;0.8 0.7il.5;1.5 Cs-137 1.li1.4;1.4 -0.310.9;0.9 -0.411.3;1.3 Ba-La-140 -0.610.8.;0.8 0.2il.0;1.0 0.6i0.8;0.8 Date Collected 07-07-94 10-03-94 10-03-94 Lab Code BYF-2804 BYF-5489 BYF-5490 Type Channel Catfish Carp Carpsucker Mn-54 -1.3i2.0;2.0 -0.110.4;0.4 0.010.5;0.5 E Fe-59 -2.0i4.3;4.3 -0.310.8;0.8 0.6tl.2;1.2 E Co-58 1.4il.8;1.8 0.20.4;0.4 -0.510.6;0.6 Co-60 0.912.3;2.3 0.010.4;0.4 -0.2i0.7;0.7 Zn-65 -1.513.1;3.1 0.6i0.8;0.8 0.71.4;1.4 Zr-Nb-95 2.012.9;2.9 0.010.6;0.6 0.li0.1;0.1 Cs-134 0.8t2.2;2.2 0.010.4;0.4 -0.li0.6;0.6 Cs-137 0.9il.5;1.5 0.210.4;0.4 0.010.6;0.6 Ba-La-140 0.612.2;2.2 -0.li0.4;0.4 -0.310.9;0.9 I 125 =

BYRON I Table 4. Fish, Edible Portions I Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration BY-12 Oregon Pool of Rock River. Downstream Date Collected 10-03-94 10-03-94 10-03-94 Lab Code BYF-5491 BYF-5492 BYF-5493 Type Big Mouth Bass Shorthead Redhorse Small Mouth Bass Mn-54 0.4i0.5;0.5 0.4i0.4;0.4 0.010.9;0.9 Fe-59 -0.110.6;0.6 -0.4tl.2;1.2 0.2il.8;1.8 Co-58 0.0i0.5;0.5 0.510.5;0.5 0.2i0.8;0.8 Co-60 0.310.4;0.4 0.0i0.8;0.8 0.li1.2;1.2 Zn-65 -0.111.4;1.4 0.lil.4;1.4 -1.4i2.1;2.1 Zr-Nb-95 0.li0.2;0.2 0.4tl.0;1.0 -0. lil.5;1.5 Cs-134 0.010.1;0.1 0.0i0.7;0.7 0.111.0;1.0 I Cs-137 -0.li0.6;0.6 0.310.6;0.6 0.611.0;1.0 Ba-La-140 0.4i4.0;4.0 0.5i0.9;0.9 0.lil.0;1.0 I I 'I 126 I

0_ O~ BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration BY-13(C) Rock River. Upstream Date Collected 05-23-94 05-23-94 05-23-94 Lab Code BYF-1429 BYF-1430 BYF-1431 Type Carpsucker Freshwater Drum Carp Mn-54 -0.511.3;1.3 0.210.7;0.7 -0.910.8;0.8 Fe-59 0.713.5;3.5 0.4il.8;1.8 0.Sil.7;1.7 Co-58 -0.4 fl.3;1.3 -0.210.6;0.6 -0.410.8;0.8 l Co-60 -0.3il.7;1.7 0.811.0;1.0 -0.3fl.0;1.0 Zn-65 0.3i2.9;2.9 1.611.9;1.9 -0.4i2.0;2.0 Zr-Nb-95 1.612.3;2.3 0.311.4;1.4 0.0il.4;1.4 Cs-134 -0.Sil.5;1.5 0.310.8;0.8 0.110.9;0.9 Cs-137 1.lil.4;1.4 0.610.8;0.8 -0.710.8;0.8 Ba-La-140 1.711.5;1.5 -0.8tl.2;1.2 -0.9il.4;1.4 Date Collected 05-23-94 07-07-94 07-07-94 Lab Code BYF-1432 BYF-2811 BYF-2812 Type Golden Redhorse Carp Silver Redhorse Mn-54 0.310.9;0.9 0.310.7;0.7 -0.310.9;0.9 Fe-59 -3.8i2.9;2.9 -1.011.6;1.6 -1.li2.4;2.4 Co-58 0.411.0;1.0 0.5i0.6;0.6 -0.110.9;0.9 Co-60 -0.311.4;1.4 -0.110.7;0.7 0.4fl.1;1.1 Zn-65 -0.212.9;2.9 0.411.5;1.5 -1.112.3;2.3 Zr-At-95 -0.411.8;1.8 -0.4fl.2;1.2 -0.411.8;1.8 Cs-134 -0.311.1;1.1 0.010.7;0.7 -0.411.0;1.0 Cs-137 0.110.9;0.9 0.310.7;0.7 0.9il.0;1.0 Ba-La-140 0.110.2;0.2 -2.2il.1;1.2 0.5il.0;1.0 I 127 I m 4

1 I BYRON l 1 Table 4. Fish, Edible Portions I Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration l BY-13 (C) Rock River Uostream 1 Date Collected 07-07-94 07-07-94 07-07-94 Lab Code BYF-2813 BYF-2814 BYF-2815 Type Golden Redhorse Quillback Small Mouth Bass Mn-54 -0.9il.5;1.5 0.lil.0;1.0 0.3fl.4;1.4 Fe-59 -1.4i4.0;4.0 -0.7i2.5;2.5 -2.313.1;3.1 Co-58 -0.2il.6;1.6 0.510.9;0.9 -0.8il.32;1.2 Co-60 0.512.3;2.3 0.611.3;1.3 0.111.8;1.8 Zn-65 -0.513.0;3.0 2.2i2.5;2.5 -1.412.7;2.7 Zr-Nb-95 0.412.2;2.2 -0.311.5;1.5 0.2i2.1;2.1 Cs-134 1.311.6;1.6 0.1 1.2;1.2 -1.6il.6;1.6 Cs-137 -0.Sil.6;1.6 0.111.2;1.2 -1.211.5;1.5 I Ba-La-140 0.416.8;6.8 0.411.8;1.8 -0.2il.9;1.9 Date Collected 07-07-94 10-03-94 10-03-94 Lab Code BYF-2816 BYF-5500 BYF-5501 Type Channel Catfish Carp Golden Redhorse Mn-54 -0.112.3;2.3 0.8il.1;1.1 0.210.5;0.5 Fe-59 0.315.1;5.1 0.212.3;2.3 0.0il.2;1.2 Co-58 0.22.3;2.3 -0.1il.2;1.2 0.li0.5;0.5 Co-60 -1.112.5;2.5 -0.3il.5;1.5 0.310.6;0.6 I Zn-65 -0.913.2;3.2 -1.412.6;2.6 -0.6il.2;1.2 Zr-Nb-95 -0.814.1;4.1 0.lil.9;1.9 -0.110.8;0.8 Cs-134 1.2i3.2;3.2 -1.11.1;1.1 -0.310.5;0.5 Cs-137 -1.012.3;2.3 -0.2il.0;1.0 0.110.5;0.5 Ba-La-140 -1.012.8;2.8 -0.511.5;1.5 -0.410.7;0.7 t 128 I

O O, BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters g Units: 10-2 pCi/g wet weight E Sample Description and Concentration I BY-13 (C) Rock River. Upstream Date Collected 10-03-94 10-03-94 10-03-94 Lab Code BYF-5502 BYF-5503 BYF-5504 Type Carpsucker Channel Catfish Fresh Water Drum Mn-54 -0.30.7;0.7 -0.2il.0;1.0 0.310.6;0.6 Fe-59 0.4tl.4;1.4 1.312.5;2.5 -0.7il.2;1.2 Co-58 0.110.7;0.7 -0.311.0;1.0 0.2io.5;0.5 Co-60 -0.210.8;0.8 -0.811.3;1.3 0.510.7;0.7 Zn-65 0.411.6;1.6 -3.012.9;2.9 -1.2il.3;1.3 Zr-Nb-95 0.111.2;1.2 -0.li1.8;1.8 0.410.9;0.9 Cs-134 0.310.7;0.7 0.3tl.1;1.1 -0.4i0.6;0.6 Cs-137 -0.3i0.7;0.7 0.5il.0;1.0 0.310.5;0.5 Ba-La-140 0.6i0.9;0.9 -1.li1.6;1.6 0.0i0.6;0.6 I I 129 l.

BYRON lI Table 4. Fish, Edible Portions lI Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration BY-29(C) Byron. Upstream 5 Date Collected 05-23-94 05-23-94 05-23-94 Lab Code BYF-1433 BYF-1434 BYF-1435 Type Carp Carpsucker Golden Redhorse Mn-54 0.410.9;0.9 0.7il.2;1.2 -0.lil.3;1.3 Fe-59 0.4t2.6;2.6 -1.9i3.2;3.2 0.3i2.9;2.9 I Co-58 -0.411.0;1.0 0.lil.2;1.2 0.7il.2;1.2 Co-60 0.311.3;1.3 1.4tl.8;1.8 -0.611.7;1.7 Zn-65 -1.0i2.4;2.4 -3.313.1;3.1 0.813.6;3.6 I Zr-Nb-95 0.111.6;1.6 0.512.1;2.1 -0.212.2;2.2 Cs-134 -0.4i0.9;0.9 1.2il.3;1.3 -0.lil.3;1.3 Cs-137 1.111.0;1.0 0.6il.2;1.2 0.lil.3;1.3 Ba-La-140 -0.810.9;0.9 -1.0il.5;1.5 -0.2il.8;1.8 Date Collected 05-23-94 05-23-94 07-07-94 Lab Code BYF-1436 BYF-1437 BYF-2817 Type Walleye Freshwater Drum Carp Mn-54 0.210.9;0.9 -0.2i0.8;0.8 -0.10.7;0.7 Fe-59 2.3i2.5;2.5 1.6i2.0;2.0 -0.6il.4;1.4 Co-58 0.310.9;0.9 -0.lio.9;0.9 -0.610.8;0.8 Co-60 -0.411.1;1.1 0.8i1.0;1.0 -0.lil.0;1.0 Zn-65 0.512.4;2.4 -0.412.1;2.1 0.512.1;2.1 Zr-Nb-95 1.2il.9;1.9 -0.2il.6;1.6 0.411.2;1.2 Cs-134 0.111.1;1.1 0.0fl.0;1.0 0.4fl.0;1.0 Cs-137 -0.4i0.9;0.9 -0.210.9;0.9 0.3i0.8;0.8 Ba-La-140 0.3 1.7;1.7 -0.311.7;1.7 -0.3i0.5;0.5 130

U0 BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters a Units: 10-2 pCi/g wet weight l Sample Description and Concentration BY-29(C) Byron. Upstream Date Collected 07-07-94 07-07-94 07-07-94 lab Code BYF-2818 BYF-2819 BYF-2820 Type Golden Redhorse Quillback Silver Redhorse Mn-54 0.6tl.2;1.2 0.3fl.2;1.2 -0.2i0.6;0.6 Fe-59 0.7i3.0;3.0 0.912.7;2.7 0.311.4;1.4 Co-58 0.011.2;1.2 0.710.8;0.8 0.li0.6;0.6 Co-60 -0.6il.4;1.4 0.411.7;1.7 0.6i0.7;0.7 Zn-65 0.512.8;2.8 0.412.6;2.6 -0.8il.5;1.5 Zr-Nb-95 0.811.8;1.8 -0.112.1;2.1 -0.2il.0;1.0 Cs-134 -0.2il.2;1.2 -0.4tl.1;1.1 0.2io.7;0.7 Cs-137 -0.411.0;1.0 0.2il.1;1.1 -0.210.7;0.7 Ba-La-140 0.310.5;0.5 0.3il.2;1.2 1.010.8;0.8 Date Collected 07-07-94 07-07-94 07-07-94 Lab Code BYF-2821 BYF-2822 BYF-2823 Type Silver Redhorse Fresh Water Drum Small Mouth Bass Mn-54 0.611.1;1.1 -0.110.9;0.9 -0.2il.3;1.3 Fe-59 1.612.5;2.5 0.412.5;2.5 0.8i2.9;2.9 Co-58 -0.2il.0;1.0 -0.lil.2;1.2 -0.2il.3;1.3 Co-60 0.911.3;1.3 0.3fl.2;1.2 1.111.6;1.6 Zn-65 -0.112.2;2.2 -0.li2.4;2.4 2.6f2.9;2.9 Zr-Nb-95 0.lil.6;1.6 0.111.7;1.7 0.6fl.7;1.7 Cs-134 -0.911.0;1.0 1.0il.2;1.2 0.411.4;1.4 Cs-137 0.610.9;0.9 -0. lil.1;1.1 0.4il.3;1.3 Ba-La-140 0.lil.2;1.2 -1.lil.2;1.2 0.lil.7;1.7 IH 131 5, =. i

L-., ~ BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration BY-29(C) Byron. Upstream u Date Collected 10-03-94 10-03-94 10-03-94 ~ Lab Code BYF-5505 BYF-5506,7 BYF-5508 Type Carp Carpsucker Golden Redhorse P L, Mn 54 -0.2i0.9;0.9 0.110.6;0.6 -0.210.7;0.7 Fe-59 -0.612.2;2.2 -0.511.5;1.5 -0.811.8;1.8 Co-58 0.7i0.9;0.9 0.li0.7;0.7 -0.210.7;0.7 Co-60 0.611.0;1.0 -0.60.9;0.9 -0.2il.1;1.1 ~ Zn-65 1.4f2.3;2.3 0.6il.4;1.4 0.3i2.0;2.0 Zr-Nb-95 -1.11.7;1.7 0.2il.2;1.2 -0.311.-4;1.4 ~ Cs-134 0.910.8;0.8 0.010.7;0.7 0.210.8;0.8 Cs-137 0.5i0.9;0.9 0.410.7;0.7 -0.li0.9;0.9 Ba La-140 -0.6tl.3;1.3 -0.4tl.1;1.1 0.0il.0;1.0 ~ Date Collected 10-03-94 10-03-94 ~ Lab Code BYF-5509 BYF-5510 Type Silver Redhorse Walleye ~ Mn-54 0.610.8;0.8 0.610.9;0.9 Fe-59 -1.4i2.5;2.5 -0.112.0;2.0 Co-58 0.li0.8;0.8 0.311.0;1.0 Co-60 0.Sil.4;1.4 0.8tl.3;1.3 ^ Zn-65 -0.4i2.3;2.3 0.4il.8;1.8 Zr-Nb-95 0.7il.8;1.8 1.3il.3;1.3 { Cs-134 0.li0.9;0.9 0.6i0.9;0.9 Cs-137 0.8i0.8;0.8 -0.310.8;0.8 Ba-La-140 -1.711.4;1.4 -1.111.6;1.6 [ 132 e M - - - - - - - ~ ' - - - ' - '

Ea' BYRON Table 4. Fish, Edible Portions E Collection: Three (3) times per year E Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration BYSP-31 Byron. Discharce Date Collected 05-23-94 05-23-94 05-23-94 Lab Code BYF-1425 BYF-1426 BYF-1427 Type Silver Redhorse Carp Channel Catfish Mn-54 -0.5i0.9;0.9 0.411.0;1.0 0.410.7;0.7 Fe-59 0.312.1;2.1 1.112.4;2.4 0.7il.6;1.6 Co-58 0.311.0;1.0 0.2i0.9;0.9 0.510.7;0.7 Co-60 -0.21.0;1.0 1.lil.4;1.4 0.2tl.0;1.0 Zn-65 0.512.2;2.2 1.li2.0;2.0 -0.81.9;1.9 m Zr-Nb-95 -0.8il.5;1.5 0.511.4;1.4 -0.811.2;1.2 g Cs-134 -0.310.8;0.8 -0.2i0.9;0.9 1.4i0.8;0.8 Cs-137 0.310.9;0.9 -0.311.0;1.0 1.710.9;0.9 Ba-La-140 -1.811.9;1.9 -0.3tl.4;1.4 0.2il.1;1.1 Date Collected 05-23-94 07-07-94 07-07-94 Lab Code BYF-1428 BYF-2805 BYF-2806 Type Carpsucker Carp Small Mouth Bass Mn-54 0.6i0.7;0.7 0.111.4;1.4 0.4tl.0;1.0 Fe-59 1.lil.8;1.8 -0.4i3.4;3.4 1.212.5;2.5 E Co-58 0.610.8;0.8 -0.6tl.3;1.3 0.2il.0;1.0 E Co-60 1.41.1;1.1 -1.012.5;2.5 0.211.1;1.1 Zn-65 0.411.9;1.9 -1.314.4;4.4 -0.512.8;2.8 g Zr-Nb-95 0.8tl.4;1.4 0.6i2.5;2.5 0.811.7;1.7 g Cs-134 0.7i0.9;0.9 1.7il.4;1.4 -0.3tl.0;1.0 Cs-137 0.810.9;0.9 1.011.4;1.4 -0.311.1;1.1 Ba-La-140 -1.54.4;4.4 0.4f4.2;4.2 -1.211.3;1.3 133

=

t BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters Units: 10-2 pCi/g wet weight Sample Description and Concentration l BYSP-31 Byron. Discharge Date Collected 07-07-94 07-07-94 07-07-94 Lab Code BYF-2807 BYF-2808 BYF-2809 Type Carpsucker Fresh Water Drum Shorthead Redhorse Mn-54 0.110.8;0.8 0.2i0.6;0.6 0.2fl.0;1.0 I Fe-59 1.7i3.2;3.2 -0.1tl.7;1.7 1.0i2.6;2.6 I Co-58 0.111.3;1.3 -0.210.7;0.7 0.511.0;1.0 Co-60 0.8il.4;1.4 0.211.0;1.0 0.811.4;1.4 Zn-65 -1.0i3.0;3.0 0.011.7;1.7 1.li2.4;2.4 Zr-Nb-95 -0.7il.8;1.8 0.311.3;1.3 0.111.9;1.9 Cs-134 -0.4tl.1;1.1 -0.110.7;0.7 -0.2il.2;1.2 Cs-137 -0.111.4;1.4 0.3i0.7;0.7 0.5il.2;1.2 Ba-La-140 -0.6i0.8;0.8 0.4i0.5;0.5 -0.8il.6;1.6 Date Collected 07-07-94 10-03-94 10-03-94 Lab Code BYF-2810 BYF-5494 BYF-5495 Type Channel Catfish Golden Redhorse Carp Mn-54 0.3fl.4;1.4 0.410.6;0.6 0.0i0.5;0.5 I Fe-59 -1.413.7;3.7 1.6118.8;18.8 0.2il.1;1.1 Co-58 -0.911.7;1.7 -0.410.5;0.5 -0.li0.4;0.4 Co-60 1.3i2.3;2.3 -0.510.9;0.9 0.li0.6;0.6 Zn-65 -0.7i3.8;3.8 0.211.2;1.2 -0.511.2;1.2 Zr-Nb-95 2.0i2.5;2.5 -0.612.8;2.8 0.4i0.8;0.8 Cs-134 -0.8il.7;1.7 0.li2.2;2.2 -0.5i0.5;0.5 Cs-137 -0.511.7;1.7 0.310.5;0.5 0.2i0.5;0.5 Ba-La-140 0.4f14.7;14.7 1.2i2.3;2.3 0.li0.6;0.6 134

O O BYRON Table 4. Fish, Edible Portions Collection: Three (3) times per year Required LLD: 0.13 pCi/g for Cs-134, Co-58,60 and Mn-54; 0.15 pCi/g for Cs-137 and 0.26 pCi/g for all other gamma emitters g Units: 10-2 pCi/g wet weight 3 Sample Description and Concentration ID'SP-31 Byron, Discharge Date Collected 10-03-94 10-03-94 10-03-94 ' YF-5497 BYF-5498 Lab Code BYF-5496 B Type Shorthead Redhorse Carpsucker Fresh Water Drum Mn-54 0.4i0.5;0.5 -0.611.1;1.1 0.6tl.0;1.0 Fe-59 0.3il.2;1.2 1.712.3;2.3 2.4i2.3;2.3 Co-58 0.3io.5;0.5 0.0il.2;1.2 -0.311.0;1.0 Co-60 -0.2i0.6;0.6 0.2il.4;1.4 0.0il.2;1.2 Zn-65 -0.811.2;1.2 0.2i2.6;2.6 -2.6f2.8;2.8 Zr-Nb-95 -0.8i0.9;0.9 -0.6il.0;1.0 0.511.8;1.8 Cs-134 -0.2i0.5;0.5 -0.Sil.1;1.1 -0.41.0;1.0 Cs-137 0.5f0.5;0.5 0.4il.1;1.1 0.911.2;1.2 E Ba.La-140 -0.4i0.6;0.6 -2.2il.3;1.3 -0.811.6;1.6 E Date Collected 10-03-94 lab Code BYF-5499 Type Small Mouth Bass Mn-54 -1.311.5;1.5 Fe-59 -0.413.2;3.2 Co-58 0.211.4;1.4 Co-60 0.2il.7;1.7 Zn-65 0.Si3.5;3.5 Zr-Nb-95 0.912.4;2.4 j Cs-134 0.0il.6;1.6 Cs-137 0.311.5;1.5 Ba-La-140 -0.312.2;2.2 1 I 135 5

BYRON Table 5. Bottom Sediments Collection: Semiannually Required LLD: 0.15 pCi/g for Cs-134 and 0.18 pCi/g for Cs-137 and 0.20 pCi/g for all other gamma emitters Units: 10-2 pCi/g dry weight Sample Description and Concentration BY-12 Oregon Pool of Rock River Date Collected 05-14-94 10-11-94 Lab Code BYBS-1188 BYBS-5828 Mn-54 -0.4fl.8;1.8 1.0il.5;1.5 Fe-59 -2.816.4;6.4 -0.813.4;3.4 Co-58 -0.312.1;2.1 4.Si2.0;2.1 Co-60 0.312.8;2.8 3.Si2.1;2.1 Zn-65 -2.916.0;6.0 -2.913.6;3.6 Zr-Nb-95 -0.114.2;4.2 -0.2i2.7;2.7 Cs-134 -0.3i2.0;2.0 -0.61.8;1.8 Cs-137 2.3i2.1;2.1 1.011.5;1.5 Ba-La-140 -0.516.8;6.8 0.li3.0;3.0 ]lY-13 (C) Rock River. Upstream Date Collected 05-14-94 10-11-94 Lab Code BYBS-1189 BYBS-5829,30 Mn-54 2.311.4;1.4 0.71.1;1.1 Fe-59 -1.6f2.4;2.4 -1.512.2;2.2 Co-58 0.0il.4;1.4 -0.111.1;1.1 I Co-60 0.610.5;0.5 -0.4fl.1;1.1 Zn-65 1.613.1;3.1 -7.813.2;3.4 Zr-Nb-95 -2.6il.3;1.3 -1.3i2.1;2.1 Cs-134 0.li0.1;0.1 0.71.0;1.0 Cs-137 17.613.4;4.2 19.313.2;3.2 Ba-La-140 -7.2i3.5;3.6 -2.5f2.5;2.5 I I 136 I

0 0 BYRON Table 5. Bottom Sediments Collection: Semiannually Required LLD: 0.15 pCi/g for Cs-134 and u.18 pCi/g for Cs-137 and 0.20 pCi/g for all other gamma emitters Units: 10-2 pCi/g dry weight Sample Description and Concentration BY-29(C) Byron. Upstream Date Collected 05-14-94 10-11-94 Lab Code BYBS-1190 BYBS-5831 Mn-54 0.4i0.8;0.8 1.0i0.8;0.8 Fe-59 1.317.6;7.6 -0.2i0.1;0.1 Co-58 -0.2i0.8;0.8 -0.111.1;1.1 E Co-60 -0.110.2;0.2 0.811.7;1.7 3 Zn-65 2.2i2.0;2.0 -0.li2.3;2.3 Zr-Nt-95 -1.8il.3;1.3 0.110.1;0.1 Cs-134 0.lil.4;1.4 0.3i0.2;0.2 Cs-137 7.6tl.7;2.0 2.6tl.1;1.1 Ba-La-140 0.210.1;0.1 -0.2il.4;1.4 I 1 I 137 un

BYRON I Table 6. Vegetation Collection: Annually Required LLD: 0.06 pCi/g for Cs-134 and I-131 and 0.08 pCi/g for Cs-137 Units: 10-2 pCi/g wet weight Sample Description and Concentration BY-19-1 River Road Across from BY-01 Date Collected 07-26-94 0 94 07-26-94 Lab Code BYVE-3330 BYVE-3331 BYVE-3332 Type Cucumbers Zucchuu Onions I-131a Mn-54 -0.li0.7;0.7 0.3i0.9;0.9 -0.310.8;0.8 Fe-59 0.211.8;1.8 -0.2i2.1;2.1 -2.9il.9;1.9 lI s Co-58 -0.5i0.6;0.6 -0.211.0;1.0 -0.2i0.8;0.8 Co-60 0.4f0.8;0.8 0.511.0;1.0 1.2il.0;1.0 Zn-65 -0.6il.9;1.9 0.3i2.2;2.2 0.4i2.0;2.0 Zr-Nb-95 -0.4il.4;1.4 0.5fl.6;1.6 0.3tl.4;1.4 Cs-134 0.li0.7;0.7 -0.li0.9;0.9 1.2i0.9;0.9 Cs-137 0.li0.7;0.7 -0.li0.9;0.9 0.2io.9;0.9 Ba-La-140 -2.515.0;5.0 1.215.8;5.8 2.0il.6;1.6 Date Collected 07-26-94 07-26-94 5 Lab Code BYVE-3333 BYVE-3334 Type Potatoes Cabbage I-131 -0.311.3;1.3 Mn-54 0.li0.7;0.7 -0.311.0;1.0 I Fe-59 0.111.8;1.8 1.011.9;1.9 Co-58 -0.4i0.7;0.7 0.6i0.9;0.9 Co-60 0.2il.0;1.0 0.111.3;1.3 I Zn-65 -0.11.6f;1.6 0.42.0;2.0 Zr-Nb-95 0.lil.4;1.4 0.2il.5;1.5 Cs-134 0.0i0.8;0.8 0.6fl.0;1.0 ' ~ Cs-137 0.410.7;0.7 0.4i1.0;1.0 Ba-La-140 2.515.0;5.0 -0.2i0.9;0.9 a Analysis for I-131 required for green leafy vegetation only. ,I 138 I

O O BYRON Table 6. Vegetation Collection: Annually Required LLD: 0.06 pCi/g for Cs-134 and I-131 and 0.08 pCi/g for Cs-137 Units: 10-2 pCi/g wet weight Sample Description and Concentration BYSP-19-2 German Church Road Date Collected 07-20-94 07-26-94 07-26-94 Lab Code BYVE-3184 BYVE-3335 BYVE-3336 Type Rhurbarb String Beans String Beans I-131a 0.010.8;0.8 Mn-54 -0.110.7;0.7 -0.511.1;1.1 0.0il.1;1.1 Fe 59 -0.2il.6;1.6 -0.712.7;2.7 -0.412.3;2.3 Co-58 -0.110.7;0.7 -0.2il.1;1.1 -0.410.9;0.9 Co-60 0.311.0;1.0 0.811.5;1.5 0.411.4;1.4 Zn-65 -1.111.8;1.8 -2.4i3.0;3.0 -1.8i2.7;2.7 Zr-Nb-95 -0.411.2;1.2 0.611.9;1.9 -1.011.6;1.6 Cs-134 -0.110.9;0.9 0.61.1;1.1 -0.2il.0;1.0 Cs-137 0.810.8;0.8 -1.2il.1;1.1 0.4tl.1;1.1 Ba La-140 -0.110.7;0.7 -0.811.4;1.4 -0.411.2;1.2 I Date Collected 07-26-94 09-06-94 Lab Code BYVE-3337 BYVE-4527 Type Cauliflower Cantelope I-131a Mn-54 0.210.8;0.8 0.110.5;0.5 Fe-59 0.110.2;0.2 0.211.3;1.3 Co-58 0.2i0.8;0.8 -0.110.5;0.5 Co-60 0.311.1;1.1 0.210.7;0.7 3 Zn-65 1.012.2;2.2 -0.111.2;1.2 3 Zr-Nb-95 0.4fl.5;1.5 0.410.9;0.9 Cs-134 -0.410.9;0.9 -0.2io.6;0.6 Cs-137 0.4i0.9;0.9 0.210.6;0.6 Ba-La-140 0.213.4;3.4 -0.210.6;0.6 a Analysis for 1-131 required for green leafy vegetation only. I 139 5m

BYRON Table 6. Vegetation l Collection: Annually Required LLD: 0.06 pCi/g for Cs-134 and I-131 and 0.08 pCi/g for Cs-137 l Units: 10-2pCi/g wet weight i I Sample Description and Concentration f l BYSP-19-3 6773 River Road I Date Collected 07-20-94 07-20-94 09-06-94 lI Lab Code BYVE-3185 BYVE-3186 BYVE-4528 Type Squash Squash Tomatoes f I-131a Mn-54 -0.110.4;0.4 0.0i0.3;0.3 0.010.6;0.6 { Fe-59 -0.110.7;0.7 0.210.7;0.7 0.3il.3;1.3 i I Co-58 0.2103;0.3 -0.110.4;0.4 0.010.6;0.6 Co-60 0.210.4;0.4 0.2i0.4;0.4 0.010.7;0.7 Zn-65 -0.310.9;0 9 0.110.8;0.8 -0.4tl.4;1.4 Zr-Nb-95 0.2i0.7;0.7 -0.3i0.6;0.6 -0.5il.0;1.0 Cs-134 -0.210.4;0.4 0.210.4;0.4 0.010.6;0.6 l Cs-137 0.310.4;6.4 -0.210.4;0.4 0.510.6;0.6 Ba-La-140 -0.210.3;0.3 -03i0.4;0.4 0.3i0.8;0.8 1 Date Collected 09-06-94 09-06-94 I Lab Code BYVE-4529 BYVE-4530 j ) Type Okra Corn I-131a Mn-54 -0.8tl.1;1.1 -0.410.9;0.9 Fe-59 0.9il.7;1.7 0.213.2;3.2 Co-58 0.4il.1;1.1 0.4i0.9;0.9 Co-60 0.2il.8;1.8 1.0il.0;1.0 Zn-65 0.912.1;2.1 -2.012.6;2.6 l Zr Nb-95 0.212.6;2.6 -0.912.2;2.2 Cs-134 0.410.8;0.8 0.311.1;1.1 Cs-137 -0.2fl.2;1.2 -0.2il.0;1.0 Ba La-140 -0.9il.2;1.2 -2.518.5;8.5 a Analysk 'or I-131 required for green leafy vegetation only. 140 'l

BYRON Table 7. Surface Water Collection: Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-09 Woodland Creek I 1994 Collection Period January February March Lab Code BYSW-4615a BYSW-5323b BYSW-5610 I Mn-54 0.310.9:0.9 1.22.8;2.8 0.412.1;2.1 Fe-59 -0.4i2.7;2.7 -3.8111.4;11.4 1.1167.6;67.6 Co-58 0.011.2;1.2 -13.412.8;3.3 1.82.3;2.3 Co-60 1.210.8;0.8 0.li0.1;0.1 -0.2io.4;0.4 Zn-65 1.2il.7;1.7 -3.517.5;7.5 -2.114.5;4.5 Zr-Nb-95 0.512.2;2.2 0.4fl.1;1.1 0.8tl.4;1.4 Cs-134 0.3i0.9;0.9 -0.511.6;1.6 1.4i2.0;2.0 Cs-137 1.0i0.8;0.8 0.9i3.4;3.4 -1.8i2.7;2.7 Ba-La-140 1.4i10.4;10.4 0.511.9;1.9 2.4120.8;20.8 1994 Collection Period April May June Lab Code BYSW-0941 BYSW-1830 BYSW-3070 Mn-54 0.210.8;0.8 0.012.0;2.0 1.111.9;1.9 Fe-59 0.5f2.2;2.2 -0.514.4;4.4 -0.8i5.9;5.9 Co-58 0.010.9;0.9 0.312.4;2.4 -0.9i2.3;2.3 Co-60 0.00.1;0.1 -0.82.6;2.6 0.li2.6;2.6 Zn-65 -2.011.8;1.8 1.615.3;5.3 2.515.1;5.1 Zr-Nb-95 0.6tl.1;1.1 3.7i4.4;4.4 1.615.2;5.2 Cs-134 -0.510.3;0.3 -0.112.6;2.6 -1.li2.0;2.0 I Cs-137 0.610.9;0.9 -0.7f2.2;2.2 1.312.5;2.5 Ba-La-140 -0.7i0.8;0.8 -0.3i4.1;4.1 -11.617.9;8.1 a Results reflect one weekly collection during the month. b Results reflect two weekly collections during the month. I I 141

Ol 0! BYRON Table 7. Surface Water (continued) Collection: Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration H.Y-09 Woodland Creek 1994 Collection Period July August September Lab Code BYSW-3758 BYSW-4749 BYSW-5893 Mn-54 0.5i2.8;2.8 -0.12.1;2.1 -2.212.6;2.6 Fe-59 -2.6i6.9;6.9 0.714.6;4.6 0.6tl.3;1.3 Co-58 0.7i3.3;3.3 0.3i2.4;2.4 1.813.5;3.5 Co-60 0.6i2.7;2.7 1.0i2.0;2.0 -2.012.8;2.8 Zn-65 3.li5.8;5.8 -1.7i3.9;3.9 0.9 7.4;7.4 Zr-Nb-95 0.615.2;5.2 1.713.7;3.7 0.3i0.5;0.5 Cs-134 -0.13.0;3.0 1.2i2.1;2.1 0.8i0.9;0.9 Cs-137 -0.4i2.9;2.9 1.22.1;2.1 1.7i3.2;3.2 Ba-La-140 2.919.0;9.0 3.915.2;5.2 5.219.3;9.3 1994 Collection Period October November December Lab Code BYSW-6632 BYSW-7594,5 BYSW-8183 Mn-54 -0.412.6;2.6 -0.31.8;1.8 -0.613.7;3.7 Fe-59 5.717.1;7.1 1.214.4;4.4 1.818.6;8.6 Co-58 0.812.8;2.8 -0.9i2.0;2.0 -5.014.4;4.4 Co-60 -1.812.7;2.7 2.5i2.2;2.2 0.113.1:3.1 Zn-65 0.816.1;6.1 -1.214.4;4.4 -4.117.5;7.5 Zr-Nb-95 3.015.8;5.8 -0.9i3.7;3.7 5.017.1;7.1 Cs-134 1.612.8;2.8 0.812.1;2.1 -0.513.6;3.6 Cs 137 0.413.2;3.2 1.512.0;2.0 0.li3.5;3.5 Ba-La-140 -5.217.7;7.7 -0.215.2;5.2 3.3110.5;10.5 I 142

BYRON l Table 7. Surface Water (continued) Collection: Monthly composites of weekly collections r Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; L 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration DY-12 Oregon Pool of Rock River. Downstream 1994 Collection Period January February March Lab Code BYSW-4968 BYSW-5324 BYSW-5611 j Mn-54 -0.li2.3;2.3 1.2i2.1;2.1 -1.012.6;2.6 [ Fe-59 6.0i6.1;6.1 1.4t18.6;18.6 2.6i22.7;22.7 Co-58 0.7i3.4;3.4 -0.911.8;1.8 1.2i2.1;2.1 Co-60 3.513.3;3.3 2.3i8.8;8.8 0.110.3;0.3 Zn-65 -3.217.9;7.9 0.414.2;4.2 -1.6i4.9;4.9 Zr-Nb-95 -1.215.9;5.9 -0.6i0.5;0.5 -4.4i10.7;10.7 Cs-134 0.li3.2;3.2 -0.913.1;3.1 1.li2.6;2.6 Cs-137 1.813.0;3.0 -0.2i2.4;2.4 0.212.3;2.3 i Ba-La-140 -0.75.7;5.7 0.2i0.2;0.2 0.813.6;3.6 1 1994 Collection Period April May June Lab Code BYSW-0942 BYSW-1831 BYSW-3071 Mn-54 0.2i0.8;0.8 0.4fl.6;1.6 -1.4i2.2;2.2 Fe-59 -1.511.6;1.6 1.213.4;3.4 -2.716.5;6.5 Co-58 -0.510.7;0.7 0.6il.7;1.7 -0.7i2.8;2.8 Co-60 0.310.7;0.7 0.811.8;1.8 -2.0i2.4;2.4 Zn-65 -0.8tl.6;1.6 -2.513.5;3.5 -0.813.8;3.8 Zr-Nb-95 -0.3il.4;1.4 0.913.1;3.1 1.2i5.4;5.4 Cs-134 0.lio.1;0.1 -1.3tl.8;1.8 1.512.7;2.7 Cs-137 -0.4i0.8;0.8 0.3tl.7;1.7 0.9i2.6;2.6 Ba-La-140 -1.0il.7;1.7 -0.5i3.9;3.9 -3.8i12.9;12.9 [ 1 143 I

E= BYRON Table 7. Surface Water (continued) Collection: Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters E Units: pCi/L g Sample Description and Concentration BY-12 Oregon Pool of Rock River. Downstream I 1994 Collection Period July August September Lab Code BYSW-3759 BYSW-4750 BYSW-5894 Mn-54 1.212.6;2.6 0.3il.5;1.5 -1.013.1;3.1 Fe-59 0.916.9;6.9 3.114.2;4.2 -9.619.1;9.1 Co-58 -2.013.0;3.0 -0.4il.8;1.8 -2. li3.1;3.1 Co-60 -0.6i3.4;3.4 -0.31.6;1.6 -1.li3.5;3.5 Zn-65 -0.415.8;5.8 -0.4i3.5;3.5 8.116.5;6.8 Zr-Nb-95 5.6i5.0;5.0 0.313.1;3.1 1.916.6;6.6 Cs-134 -2.913.1;3.1 -0.411.7;1.7 0.313.3;3.3 Cs 137 0.213.2;3.2 0.7il.6;1.6 0.313.4;3.4 E Ba-La-140 3.314.9;4.9 -0.2i14.4;14.4 5.li6.1;6.1 5 1994 Collection Period October November December Lab Code BYSW-6633 BYSW-7596 BYSW-8184 Mn-54 0.412.8;2.8 -1.712.1;2.1 -0.112.7;2.7 Fe-59 1.516.6;6.6 0.3i5.0;5.0 0.4i6.4;6.4 Co-58 0.713.2;3.2 1.412.6;2.6 -0.613.1;3.1 Co-60 1.0i3.1;3.1 1.412.2;2.2 -0.8i3.3;3.3 Zn-65 0.714.8;4.8 -3.514.6;4.6 -0.115.8;5.8 Zr-Nb-95 -3.616.0;6.0 -2.914.6;4.6 0.315.3;5.3 Cs-134 0.712.8;2.8 0.612.3;2.3 0.3i2.7;2.7 Cs-137 0.5i3.0;3.0 0.712.1;2.1 0.2i3.0;3.0 Ba-La-140 -3.718.9;8.9 1.614.9;4.9 -1.617.8;7.8 I

BYRON Table 7. Surface Water (continued) I Collection: Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/l, foi all other gamma emitters Units: pCi/L Sample Description and Concentration I BY-13(C) Rock River. Upstream 1994 Collection Period Jar.uary February March Lab Code NSa BYSW-5325b BYSW-5612 I Mn-54 -1.0i2.8;2.8 1.9i2.6;2.6 Fe-59 0.91.0;1.0 4.2i320;320 I Co-58 0.612.7;2.7 0.6i3.2;3.2 Co-60 1.914.6;4.6 1.4i3.0;3.0 Zn-65 1.415.5;5.5 -2.li6.7;6.7 Zr-Nb-95 -2.3i5.5;5.5 -3.2i49.7;49.7 Cs-134 1.7il.8;1.8 1.0il.2;1.2 Cs-137 1.2i2.8;2.8 0.913.4;3.4 Ba-La-140 -7.1t289;289 2.112.7;2.7 1994 Collection Period April May June Lab Code BYSW-0943 BYSW-1832 BYSW-3072 Mn-54 -0.411.6;1.6 -1.6tl.9;1.9 1.0il.8;1.8 Fe-59 0.81.4;1.4 -0.215.1;5.1 2.213.9;3.9 Co-58 -0.4tl.6;1.6 0.4i2.3;2.3 0.3i2.1;2.1 Co-60 0.210.2;0.2 0.4i2.4;2.4 0.5il.4;1.4 Zn-65 -3.li3.1;3.1 0.014.7;4.7 0.li3.0;3.0 Zr-ht-95 1.818.8;8.8 2.0i4.2;4.2 -1.013.6;3.6 Cs-134 -0.63.7;3.7 0.8i2.2;2.2 0.4il.8;1.8 I Cs-137 1.311.9;1.9 0.012.4;2.4 2.li2.1;2.1 Ba-La-140 -1.2i2.3;2.3 3.3i4.0;4.0 -3.9i6.5;6.5 j a NS = No Sample; Rock River frozen. b Results reflect two weekly collections during the month. I 145

O O BYRON Table 7. Surface Water (continued) E Collection: Monthly composites of weekly collections E Required LLD: 15 pCi/1. for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L :ar Cs-137; 30.0 pCi/L for all other gamma emitters g Units: pCi/L g Sample Description and Concentration I BY-13 (C) Rock River. Unstream 1994 Collection Period July August September Lab Code BYSW-3785 BYSW-4751 BYSW-5895 Mn-54 -1.212.4;2.4 1.2il.3;1.3 0.3il.8;1.8 Fe-59 -0.3i6.0;6.0 0.5i3.6;3.6 -0.7i5.3;5.3 Co-58 1.112.8;2.8 -0.811.5;1.5 -0.511.9;1.9 Co-60 0.5i2.5;2.5 0.311.4;1.4 2.lil.8;1.8 Zn-65 -4.914.9;4.9 0.812.3;2.3 -1.9i2.8;2.8 Zr-Nb-95 0.714.9;4.9 0.5i2.5;2.5 -3.2i4.6;4.6 Cs-134 0.113.1;3.1 0.li1.5;1.5 1.612.2;2.2 Cs-137 0.212.8;2.8 0.911.5;1.5 1.411.9;1.9 E Ba-La-140 -4.3i4.8;4.8 2.213.6;3.6 1.8i4.7;4.7 3 1994 Collection Period October November December Lab Code BYSW-6634 BYSW-7597 BYSW-8185 Mn-54 0.6i3.2;3.2 -1.512.6;2.6 -0.811.7;1.7 Fe-59 6.2i6.8;6.8 -0.617.2;7 2 0.613.6;3.6 Co-58 -3.0i3.3;3.3 1.2i2.6;2.6 -0.2il.9;1.9 Co-60 -3.7i3.0;3.0 -0.4i2.8;2.8 0.li2.0;2.0 Zn-65 1.6i4.8;4.8 0.614.8;4.8 -0.7i3.5;3.5 Zr-Nb-95 4.415.6;5.6 1.3i4.4;4.4 1.013.0;3.0 Cs-134 2.2i2.2;2.2 1.0i2.8;2.8 1.6tl.8;1.8 Cs-137 1.912.8;2.8 -0. li2.9;2.9 0.912.0;2.0 g Ba-La-140 0.911.6;1.6 -3.816.8;6.8 -3.314.2;4.2 g 146 u

I I f BYRON lI Table 7. Surface Water (continued) f Collection: Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; L 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-29(C) Byron. Upstream j I 1994 Collection Period January February March Lab Code NSa BYSW-5326b BYSW-5613 Mn-54 1.4tl.2;1.2 -4.2i4.1;4.1 Fe-59 -0.32.4;2.4 -2.8i9.3;9.3 Co-58 0.8i1.3;1.3 -1.514.3;4.3 Co-60 1.613.9;3.9 2.0i6.3;6.3 l 72 -65 -2.613.4;3.4 -0.418.8;83.8 l I Zr-Nb-95 -0.2i2.6;2.6 -5.7i10.8;10.8 Cs-134 1.511.6;1.6 0.6tl.0;1.0 j Cs-137 0.4tl.4;1.4 1.314.8;4.8 i Ba-La-140 2.21208;208 -5.4i108;108 1994 Collection Period April May June Lab Code BYSW-0944 BYSW-1833 BYSW-3073 Mn-54 -0.5i2.6;2.6 -2.213.3;3.3 0.211.3;1.3 Fe-59 3.515.6;5.6 1.3i9.9;9.9 -0.8i3.8;3.8 Co-58 0.912.2;2.2 -4.4i4.3;4.3 0.7il.4;1.4 I Co-60 3.2i2.5;2.5 3.0i4.6;46 -0. lil.3;1.3 Zn-65 1.615.0;5.0 -2.li8.2;8.2 -3.312.6;2.6 Zr-Nb-95 -1.2i4.2;4.2 -1.2i7.4;7.4 -0.6i2.6;2.6 I Cs-134 0.412.8;2.8 0.3i4.5;4.5 0.7il.4;1.4 Cs-137 2.5i2.8;2.8 -1.9i4.4;4.4 0.911.3;1.3 Ba-La-140 -4.1t4.7;4.7 -4.0i7.0;7.0 -5.61.5.9;5.9 I a NS = No Sample; Rock River frozen. b Results reflect two weekly collections during the month. 147 I

E_ O~ BYRON Table 7. Surface Water (continued) Collection: Monthly composites of weekly collections Required LLD: 15 pC;/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration I BY-29(C) Byron. Upstream 1994 Collection Period July August September Lab Code BYSW-3786 BYSW-4752 BYSW-5896 Mn-54 0.3i2.7;2.7 -0.8il.7;1.7 -0.9i2.2;2.2 Fe-59 -3.0i6.7;6.7 2.5i3.2;3.2 2.li5.8;5.8 Co-58 -0.3i3.3;3.3 1.0il.8;1.8 -0.4t2.7;2.7 Co-60 1.3i2.5;2.5 0.4il.5;1.5 1.0i2.0;2.0 Zn-65 1.li8.2;8.2 0.4i3.1;3.1 -4.2i4.5;4.5 Zr-Nb-95 0.815.6;5.6 1.8i3.1;3.1 -1.814.4;4.4 Cs-134 0.3i3.4;3.4 -0.11.8;1.8 -0.li2.4;2.4 Cs-137 3.2i3.2;3.2 0.lil.9;1.9 1.2i2.4;2.4 Ba-La-140 -0.7i5.7;5.7 2.5i4.2;4.2 7.3i4.8;5.0 1994 Collection Period October November December Lab Code b YSW-6635,6 BYSW-7598 BYSW-8186 Mn-54 0.9il.8;1.8 0.5i2.6;2.6 -0.2i2.0;2.0 Fe-59 1.6i4.3;4.3 -1.417.4;7.4 1.6i5.3;5.3 Co-58 0.2il.8;1.8 -0.li2.9;2.9 -0.812.1;2.1 Co-60 0.8tl.5;1.5 0.3i2.9;2.9 1.5i2.3;2.3 Zn-65 0.913.7;3.7 -1.915.0;5.0 0.114.6;4.6 i Zr-Nb-95 0.3i3.0;3.0 1.215.3;5.3 2.014.0;4.0 1 Cs-134 -0.4tl.7;1.7 0.7i3.0;3.0 -0.812.7;2.7 Cs-137 0.9i2.0;2.0 0.6i3.5;3.5 0.912.3;2.3 Ba La-140 -1.514.2;4.2 0.517.3;7.3 1.7i4.5;4.5 l I 148

BYRON Table 7. Surface Water Collection: Quarterly composites of weekly collections Required LLD: 200 pCi/L for H-3 Units: pCi/L QUARTERLY COMPOSITES 1994 I Composite Concentration (pci/L) Period Lab Code Tritium I BY-09 Woodland Creek I 1st Quarter BYSW-5553 5i96;96 2nd Quarter -2686 112i84;85 3rd Quarter -5171 84174;75 4th Quarter -8052 42i81;81 BY-12 Orecon Pool of Rock River. Downstream 1st Quarter BYSW-5554a 1,391 140;236 2nd Quarter -2687b 915 111;167 I 3rd Quarter -5172 473i90;110 4th Quarter -8053 574i103;129 BY-13(C) Rock River. Uostream 1st Quarter BYSW-5555 97 100;101 I 2nd Quarter -2688 110182;83 3rd Quarter -5173 -4i74;74 4th Quarter -8054 64i82;82 I BY-29(C) Byron. Upstream 1st Quarter BYSW-5556 -6i93;93 2nd Quarter -2689 32178;78 3rd Quarter -5174 100178;80 4th Quarter -8055 17180;80 a Sample was reanalyzed; result of reanalysis is 1,633i147;266 pCi/L. b A recomposite of the weekly collections was analyzed; result of analysis is 8081111:156 pCi/L. I 149 I

BYRON l Table 8. Well Water Collection: Monthly i Required LLD: 4.0 pCi/L for Gross Beta and 200 pCi/L for H-3; ( 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration BY-14 CECO Offsite Well 1 Collection Date 01-03-94 02-07-94 03-07-94 Lab Code BYWW-4617 BYWW-4996 BYWW-5335 Gross Beta -0.7il.0;1.0 1.511.2;1.2 -0.2il.7;1.7 H-3 23i98;98 41193;93 121i99;100 Mn-54 0.412.8;2.8 1.lil.9;1.9 0.2i0.6;0.6 Fe-59 1.813.7;3.7 0.414.4;4.4 -1.3f2.9;2.9 Co-58 -0.913.1;3.1 -1.012.1;2.1 -0.2i0.8;0.8 Co-60 0.913.9;3.9 -0.911.9;1.9 0.2i0.9;0.9 i Zn-65 2.913.7;3.7 2.7i3.9;3.9 -0.7il.2;1.2 i E Zr-Nb-95 1.7i5.2;5.2 -2.513.2;3.2 0.710.7;0.7 E Cs-134 -1 o*2.9;2.9 -0.3i2.0;2.0 0.6i0.6;0.6 l Cs-137 1.0i2.7;2.7 1.212.1;2.1 0.2i0.6;0.6 l Ba-La-140 -0.3110.1;10.1 1.014.0;4.0 -8.3i5.5;5.5 Collection Date 04-04-94 05-07-94 06-04-94 Lab Code BYWW-0154 BYWW-0893,4 BYWW-1842 f Gross Beta 0.2il.0;1.0 0.6tl.3;1.3 0.310.8;0.8 H-3 -40192;92 139i67;68 89178;78 Mn-54 -1.2il.9;1.9 0.8tl.5;1.5 0.6i0.9;0.9 I Fe-59 -4.5i37.7;37.7 0.419.2;9.2 -1.413.4;3.4 Co-58 -0.512.0;2.0 1.311.7;1.7 -0.611.4;1.4 Co-60 0.9il.6;1.6 -0.112.6;2.6 0.8i0.9;0.9 72 -65 0.513.6;3.6 0.9i3.8;3.8 -1.611.8;1.8 I Zr-Nb-95 -0.1i0.1;0.1 1.41.4;1.4 1.li2.4;2.4 Cs-134 0.710.6;0.6 0.015.2;5.2 0.3il.0;1.0 Cs-137 0.7i2.2;2.2 1.2il.9;1.9 0.8tl.0;1.0 Ba-La-140 -1.6i2.4;2.4 2.0i3.7;3.7 -12.9117.5;17.5 I 150 I

O O BYRON Table 8. Well Water (continued) Collection: Monthly Required LLD: 4.0 pCi/L for Gross Beta and 200 pCi/L for H-3, 15 pCi/L for Cs-134, Co-5S,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamrna ernitters 3 Units: pCi/L g Sample Description and Concentration BY-14 CECO Offsite Well Collection Date 07-11-94 08-02-94 09-06-94 Lab Code BYWW-3038 BYWW-3608 BYWW-4535 Gross Beta 2.2il.9;1.9 0.9fl.3;1.3 -0.411.2;1.2 H-3 119184;86 50183;83 82183;84 Mn-54 -0.5il.1;1.1 0.011.5;1.5 1.812.5;2.5 Fe-59 0.113.2;3.2 -2.814.4;4.4 -0.3i3.4;3.4 Co-58 -0.411.4;1.4 0.211.8;1.8 0.22.6;2.6 Co-50 -0.2fl.2;1.2 0.9il.6;1.6 1.4i2.5;2.5 Zn-65 -1.012.6;2.6 -3.0i3.7;3.7 -1.3i4.8;4.8 Zr-Nb-95 1.212.6;2.6 1.813.3;3.3 -0.310.9;0.9 Cs-134 -0.2il.3;1.3 0.8il.7;1.7 -2.114.9;4.9 Cs-137 -0.3il.3;1.3 0.6tl.7;1.7 1.Si2.6;2.6 E Ba-La-140 -8.816.9;7.0 -3.2i6.5;6.5 -0.6fl.1;1.1 5 Collection Date 10-11-94 11-01-94 12-06-94 Lab Code BYWW-5827 BYWW-6436 BYWW-7433 Gross Beta -0.li1.2;1.2 0.7il.3;1.3 1.4il.4;1.4 H-3 120178;79 641.82;83 172185;88 Mn-54 1.012.3;2.3 2.8i2.8;2.8 -1.4i2.8;2.8 Fe-59 6.7il7.4;17.4 -2.316.7;6.7 -3.2i6.7;6.7 Co-58 -6.li3.4;3.4 -1.713.1;3.1 -2.913.3;3.3 Co-60 2.916.9;6.9 -0.2io.3;0.3 0.7i3.3;3.3 Zn-65 1.8i5.2;5.2 -2.2i5.2;5.2 -1.8i5.0;5.0 Zr Nb-95 -0.710.7;0.7 4.3i4.8;4.8 -3.3i6.2;6.2 Cs-134 1.0119.7;19.7 3.5i3.2;3.2 -0.313.0;3.0 E Cs-137 2.012.4;2.4 1.8i3.0;3.0 0.8i3.3;3.3 E Ba-La-140 -6.3i21.4;21.4 -5.8i10.0;10.0 5.2i4.1;4.2 E E m

BYRON Table 8. Well Water (continued) Collection: Monthly Required LLD: 4.0 pCi/L for Gross Beta and 200 pCi/L for H-3; 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration I BY-18 McCoy Farmstead Well Collection Date 01-03-94 02-07-94 03-07-94 Lab Code BYWW-4618 BYWW-4997 BYWW-5336 Gross Beta -0.St1.0;1.0 1.2il.2;1.2 0.8il.8;1.8 H-3 9i98;98 -26190;90 66197;97 Mn-54 1.li3.4;3.4 -0.lil.3;1.3 -0.6i0.8;0.8 Fe-59 -3.115.5;5.5 0.4i3.0;3.0 -1.8133.7;33.7 I Co-58 0.013.2;3.2 -1.2il.5;1.5 -0.4tl.2;1.2 Co-60 0.913.3;3.3 1.7il.4;1.4 0.4i2.2;2.2 Zn-65 -1.4i7.2;7.2 0.3i2.6;2.6 -3.8il.9;1.9 Zr-Nb-95 0.415.6;5.6 -0.12.4;2.4 -0.310.3;0.3 Cs-134 -2.6i2.8;2.8 -0.2il.5;1.5 -0.2i0.2;0.2 Cs-137 0.3i3.6;3.6 0.9tl.6;1.6 0.70.8;0.8 Ba-La-140 -0.6i5.2;5.2 1.2i2.4;2.4 -1.0i99.5;99.5 Collection Date 04-04-94 05-07-94 06-04-94 Lab Code BYSW-0155 BYWW-0895 BYWW-1843,4 Gross Beta 0.811.0;1.0 1.111.1;1.1 0.610.5;0.5 H-3 36i96;96 140195;97 104i55;56 Mn-54 2.4i3.7;3.7 -0.512.8;2.8 -0.11.2;1.2 I Fe-59 -1.2i8.0;8.0 -1.815.6;5.6 0.4i4.4;4.4 Co-58 1.913.5;3.5 -1.412.9;2.9 -0.4fl.5;1.5 Co-60 0.5f3.8;3.8 2.5i2.8;2.8 0.911.2;1.2 Zn-65 -4.519.2;9.2 -1.215.7;5.7 -3.li2.9;2.9 I Zr-Nb-95 -0.7i6.9;6.9 -0.24.4;4.4 0.2i3.0;3.0 Cs-134 -3.3i3.7;3.7 0.7i2.9;2.9 0.4il.1;1.1 Cs-137 -2.0i4.0;4.0 0.2i3.1;3.1 0.Sil.1;1.1 Ba-La-140 5.817.7;7.7 0.5i5.8;5.8 -1.li15.0;15.0 I II 152 I

E. BYRON l Table 8. Well Water (continued) Collection: Monthly Required LLD: 4.0 pCi/L for Gross Beta and 200 pCi/L for H-3; 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30.0 pCi/L for all other gamma emitters Units: pCi/L Sample Description and Concentration I BY-18 McCoy Farmstead Well Collection Date 07-02-94 08-02-94 09-06-94 Lab Code BYWW-2673 BYWW-3609 BYWW-4536 I Gross Beta 2.011.4;1.4 0.811.3;1.3 1.8il.4;1.4 H-3 33i81;81 112183;84 61182;82 Mn-54 0.8tl.7;1.7 0.411.1;1.1 0.012.1;2.1 Fe-59 2.4i3.8;3.8 0.li2.6;2.6 -3.Si29.3;29.3 Co-58 0.lil.8;1.8 0.7il.3;1.3 -0.4i2.4;2.4 Co-60 1.2il.7;1.7 -0.111.1;1.1 0.811.7;1.7 Zn-65 0.1t3.4;3.4 0.112.3;2.3 0.3i5.0;5.0 Zr-Nb-95 -4.413.6;3.6 1.012.4;2.4 0.511.8;1.8 Cs-134 -0.lil.6;1.6 0.7il.2;1.2 -1.311.1;1.1 Cs-137 0.7il.8;1.8 0.8tl.2;1.2 1.7i2.7;2.7 Ba-La-140 -1.3118.5;18.5 -3.4i4.6;4.6 -2.5i3.6;3.6 Collection Date 10-04-94 11-01-94 12-06-94 Lab Code BYWW-5535 BYWW-6437 BYWW-7434 Gross Beta 0.4tl.2;1.6 0.Sil.2;1.2 0.5fl.3;1.3 H-3 87i76;77 92183;84 37i79;79 Mn-54 0.612.3;2.3 -1.2i3.0;3.0 0.612.8;2.8 Fe-59 -3.217.2;7.2 -4.8i6.6;6.6 -0.8i6.4;6.4 Co-58 1.012.8;2.8 -0.13.0;3.0 1.012.9;2.9 Co-60 2.612.6;2.6 3.616.5;6.5 -1.813.6;3.6 i Zn-65 2.214.8;4.8 2.415.6;5.6 -1.7t7.2;7.2 Zr-Nb-95 -0.715.1;5.1 0.510.5;0.5 2.2i6.3;6.3 Cs-134 -1.7i3.7;3.7 -2,2i4.0;4.0 0.63.4;3.4 Cs-137 -2.512.8;2.8 -2.013.2;3.2 1.7i3.1;3.1 g Ba-La-140 11.9119.9;19.9 -0.6il 7.9;17.9 0.116.5;6.5 g ( I I 153

L BYRON r~ L~ b nL [ E [ MILCH ANIMALS, NEAREST LIVESTOCK, AND NEAREST RESIDENCES CENSUSES l [ E E E E W [ [ [ m 1 _-__ A

I BYRON I MILCH ANIMALS CENSUS 1994 A. There are seven dairy farms within a 6.5 mile radius of Byron Station. B. Sampling Locations BY-20 K. Reeverts Dairy Farm 1.9 miles @ 37 Number of cows - 30 Diet consists of: no pasture 100% feed BY-26 Glen Hazzard's Dairy 11.8 miles @ 355" Number of cows - 26 Diet consists of: 10% pasture 90% feed BY-27 Kenneth Druien Dairy Farm 5.2 miles @ 240 Number of cows - 51 Diet consists of: 10% pasture 90% feed I BYSP-28 Duane Camling Dairy Farm 3.0 miles @ 305 Number of cows - 26 Diet consists of: 50% pasture 50% feed I BY-30 Don Roos Dairy 5.1 miles @ 125 Number of cows - 35 Diet consists of: no pasture 100% feed l 155

E

  • 1 BYRON MILCH ANIMALS CENSUS 1994 B.

Samoline Locations (continued) Shamrock View Farma 4.8 miles @ 180 Number of cows - 60 Diet consists of: 25% pasture 75% feed Ashelforda 2.5 miles @ 272* g Number of cows - 20 Diet consists of: 10% pasture 90% feed 1 a Non-participating. Census conducted by W. Mueller on August 18,1994. l l I i 156 en

BYRON [ NEAREST LIVESTOCK CENSUS,1994 [ Nearest livestock of the Byron. Station within a 6.5 mile radius. Sector Direction Distance A N 3.0 miles l B NWE 1.5 miles C NE 4.7 miles D ENE 3.0 miles E E 2.8 miles F ESE 1.5 miles G SE 6.2 miles [ H SSE 3.2 miles J S 0.6 miles K SSW 2.2 miles L SW 3.2 miles M WSW 1.7 miles N W 2.5 miles P WNW 3.5 miles {- Q NW 3.8 miles .R' NNW 1.4 ~ miles { Census conducted by W. Mueller on August 17 and 18,1994. [ 157

E, O BYRON NEAREST RESIDENCE CENSUS,1994 Nearest resident of the Byron Station within a 6.5 mile radius. Sector Direction Distance A N 2.7 miles B NNE 1.0 miles C NE 1.2 miles D ENE 1.3 miles E E 1.3 miles F ESE 1.4 miles G SE 0.8 miles H SSE 0.6 miles J S 0.5 miles K SSW 0.6 miles L SW 0.8 miles M WSW 1.7 miles N W 1.8 miles P WNW 0.8 miles Q NW 1.0 miles R NNW 1.3 miles - I Census conducted by W. Mueller on August 17,1994. I 158 =,

I BYRON i .'I i l 1 4 I i e I i

I s

i 4.0 TLD DATA' 2 1 i 6 f 'TLD Data provided by Commonwealth Edison Company. 159

I l Commonwealth Edison Company Dato: 3-MAR-95 Environ 4 ental Site Report for Byron Pages 1 Gamma Radiation Measured in mR by TLDs Sito Miles Degrees Description Quarter 1 Quarter 2 Quarter 3 Quarter 4 1994 1994 1994 1994 Cir Samplers (2 TLDs per location! BY-21 0.3 9 BYRON NEAR-SITE NORTH 11.2 11.3 10.9 14.2 BY-22 0.3 101 BYRON NEAR-SITE EAST SOUTHEAST 16.4 16.1 15.4 19.3 l I?:l! 8:t lit 113 " 2:lliE 18tiiHwEST 11:1 12:! 11:1 19:1 4 l Mein i S.D. 14.1 1 2.2 14.3 1 2.1 13.7 1 2.0 17.3 1 2.4 f Annual Mean and S.D. 14.8 1 2.4 Ctr Samplers (2 TLDs per locatlon! BY-01 3.5 25 BYRON NORTH NORTHEAST 11.7 12.4 11.4 15.4 i SY-03 3.8 85 NEAR-SITE EAST 13.6 14.7 14.0 17.7 1 BY-04 4.5 140 PAYNES POINT SOUTHEAST 15.0 16.2 14.8 4 19.2 } BY-05 3.6 180 NEAR-SITE SOUTH 15.8 15.9 16.0 20.3 BY-06 4.6 213 WEST SOUTHWEST 13.6 12.6 12.1 17.0 ) l Mein t S.D. 13.9 1 1.6 14.4 1 1.3 13.7 1 1.9 17.9 g 1.9 Annual Mean and S.D. 15.0 1 2.4 CONTROL LOCATIONS (2 TLDs per location! BY-02 6.2 56 ST!LLMAN VALLEY NORTHEAST 13.1 13.5 12.5 16.5 I BY-07 7.3 240 MOUNT MORRIS WEST SOUTHWEST 14.3 14.8 13.4 17.8 BY-C3 7.0 315 LEAF RIVER NORTHWEST 13.1 14.0 12.7 16.6 M;cn 1 S.D. 13.5 t 0.7 14.1 1 0.7 12.9 1 0 5 16.9 1 0.7 Annual Mean and S.D. 14.3 1 1.7 l Inner Ring (100 Series, 2 TLDs per location 1 l BY-101 1.2 13 NORTH NORTHEAST 16.7 17.6 BY-102 1.0 25 NORTH NORTHEAST 16.1 17.1 16.5 19.9 BY-103 1.7 51 NORTHEAST 15.7 16.3 15.9 19.0 BY-104 1.4 64 EAST NORTHEAST 15.9 16.7 16.9 19.3 BY-105 1.3 B4 EAST 16.2 17.7 16.7 20.3 BY-106 1.4 103 EAST SOUTHEAST 15.6 16.6 16.1 19.9 BY-107 1.4 141 SOUTHEAST 16.6 17.3 17.0 20.1 BY-108 0.6 158 SOUTH SOUTHEAST 15.2 16.1 15.1 18.3 BY-109 0.6 183 SOUTH 14.4 15.8 14.6 18.5 I i d i i l 160 I L-_-

M Paget 't Dat:s 3-NAR-95

  • Erwironesntc1 Sita Report lor Byron ~~ " ~ ~ *

~~ site Miles Degrees Description Guarter 1 Guarter 2 Guarter 3 Quarter 4 E 1994 1994 1994 1994 BY-110 0.6 201 SOUTH SOUmWEST 14.2 15.4 15.4 17.9 BY-111 0.9 235 SOUTHWEST 15.6 16.9 16.1 BY-112 0.8 247 WES' SOUTHWEST 14.9 15.9 14.3 15.2 e i BY-113 0.7 270 WEST 13.8 15.1 14.4 17.5 BY-114 0.9 298 WEST NORTHWEST 13.4 14.3 13.9 18.3 BY-115 1.0 314 NORTHWEST 14.2 15.5 14.6 18.1 BY-116 1.4 329 NORTH NoctTHWEST 13.3 14.2 13.3 18.9 BY111A 0.8 224 SOUTHWEST 15.2 16.4 16.1 20.3 Mean 1 S.D. 15.1 1 1.1 16.2 1 1.0 15.5 1 1.1 18.7 1 1.5 Annual Nean and S.D. 16.3 1 1.8 Outer Ring (200 Serles, 2 TLDs per locatlon) l BY-2018 4.8 360 NORTH 16.4 17.1 15.2 20.9 l BY-202 4.5 13 NORTH NORTNEAST 15.7 17.2 16.0 19.5 BY-203 5.1 42 NORTHEAST 13.3 13.8 13.3 17.0 BY-204 4.2 66 EAST NORTHEAST 15.0 15.7 15.1 19.1 BY-205 3.9 89 EAST 15.3 15.9 15.3 19.0 BY-206 4.2 112 EAST SOUTHEAST 23.5 16.7 16.4 19.3 BY-207 4.2 140 SOUTHEAST 17.0 17.2 16.3 20.7 BY-209 4.1 159 SOUTH SOUTHEAST 15.9 17.3 16.0 19.9 BY-209 3.8 189 SOUTH 15.1 16.2 15.7 19.6 BY-210b 3.6 218 SOUTHWEST 16.4 16.7 15.4 18.5 BY-21' 5.2 233 WEST SOUTHWEST 16.6 16.7 15.9 20.4 BY-212a 4.9 257 WEST SOUTHWEST 16.4 17.5 17.I 20.8 BY-283 5.0 280 16.7 17.6 16.4 20.3 BRili; i:H UI E L" M HWEST gg;g gg;} lg;g gg;g BY-216 4.8 337 NORTH NORTHWEST 16.9 17.7 15.6 20.2 Mein 1 S.D. 16.4 1 2.1 16.7 1 1.0 15.7 1 0.9 19.7 1 1.0 Annual Nean and S.D. 17.1 1 2.0 SPECIAL INTEREST LOCATIONS (1 TLD per location) BY-302 0.0 0 14.8 15.0 13.3 18.1 Mem 1 S.D. Annual Mean and S.D. 15.3 1 2.0 JMMENTS: "e" Indicates lost dostmeter. A portion of the Dose was estimated. "4' Andicates edited dotteeter. The original Dose was replaced wt ** an estimated value. a Average of 201-1,2,3,4 b Average of 210-1,2,3,4 C Average of 212-1,2.4 d Average of 213-1,2,4

  • Average of 214-1,2,4 f Average of 215-1,2,4 e

161 =

L BYRON E E E E 5.0 GRAPHS OF DATA TRENDS l E N c L [ W [ [ l 162 i 1

u Air Particulates - Gross Beta T BY-01 Byron 10.0 IL 80 l ~ 6.0 s % "" i e A h hib a* ba q\\g gj.f g3 , fj [g, 2o p, ,p 0.0 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 ~ Figure 1. Continuous collection with weekly exchange of particulate filter. L BY-02(C) Stillman Valley { 10 I 8 l E 6 S 4-e 'k.is&^,,.4.v 0 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 Figure 2. Continuous collection with weekly exchange of particulate filter. 163

0 Air Particulates - Gross Beta I BY-03 Nearsite - East 10 8 6+ 2 4 k l i.'?g, rl% !?N ;nf}liV i 4., g 0 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 Figure 3. Continuous collection with weekly exchange of particulate filter. I BY-04 Paynes Point 10.0 8.0 6.0 S J f l hk 40 ? .,i.g[!u'd I*.;fJ.u!? h '~ R l 0.0 4 l 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 Figure 4. Continuous collection with weekly exchange of particulate filter. l 164 g

L 7 Air Particulates - Gross Beta I~ BY-05 Neasite-South 10.0 7 l I 8.0j ~ 6.0 + q L i y !I f i w 4.0 C \\.f.,.,:?u,kY ~g;.y}\\llY 0 h 2" I ~ 0.0 +- 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 l Figura ~. Continuous collection with weekly exchange of particulate filter. l i l BY-06 Oregon l ~ 10.0 7 l ~ 8.0 6.0 R

.l

= l0 w 4.0

f.,

3 2a e fgA j. y g { 00 - 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 l Figure 6. Cuatinuous collection with weekly exchange of particulate filter. j 165 W

O' a Air Particulates - Gross Beta BY-07(C) Mt. Morris 10.0 l 8.0 2 6.0 + s E I J) 4 W 4-l* ' h l,\\? .I ~

  1. 4*,g.*. *% f;e. Vo..

2~0 h.. ."7fw;\\A*y*. l j \\ .s ,% *,s s E 0.0 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 Figure 7. Continuous collection with weekly exchange of particulate filter. BY-08(C) Leaf River I 10.0 I i 8.0 7 1 l 6.0 i F S I I! I W 4- ~ g .g h. p/><% ip swa

  • eg I

0.0 +-- + 0141-93 07-02-93 12-31-93 07-01-94 12-30-94 i Figure 8. Continuous collection with weekly exchange of particulate filter. a 166 5l u

I Air Particulates - Gross Beta BY-21 Byron Nearsite N i 10.0 I i I 8.0 3 6.0 -r l s k i 4.0, i a A* k'*

  • A $ep ****

I i 0.0 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 I Figure 9. Continuous collection with weekly exchange of particulate filter. l i BY-22 Byron Nearsite ESE i g 10.0 I t 8.0 4 i i 2 i { s 6.0 - j j z i y 7 l g 4.0 -l\\ [ j ~ 6 *viI' l 2o;:'.jg,,g.7,.f.:, p .N g p;,g y. I 0.0 l 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 I Figure 10. Continuous collection with weekly exchange of particulate } filter. j 167

0 0 Air Particulates - Gross Beta i BY-23 Byron Nearsite S 10.0 e 8.0 + 1 3 i l s 6.0 2 k g i & 4".\\ p s p%

  • .\\

e e ~ a ~ " h^y.;n.{ ~Q.,o;<.f.l& 0.0 +- I 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 Figure 11. Continuous collection with weekly exchange of particulate filter. i l l BY-24 Byron Nearsite SW 10.0 - 8.0j i g 6.0 N.0 hT 3 [ 4

  • *d Ib
  • h*

It'*.,g,.,g,f,,,'l d,, gg,g% g,M 2o J l "i i 2.0 a 01-01-93 07-02-93 12-31-93 07-01-94 12-30-94 Figure 12. Continuous collection with weekly exchange of particulate l l filter. ~ 168 g =

e Surface Water-Tritium l BY-09 Woodland Creek I Il 500-400 + p 300 L .a 200 I l 100 [

  • --.~e ox,, //N,\\.

j O+ i -100 i 01-01-93 07-02 93 12 31 93 07-01 94 12-30 94 Figure 13. Quarterly composites of weekly collections. i BY-12 Oregon Pool of Rock River, Downstream 1500 l 1300 [ l i 1100 I i [~ 900 L a i 700 l ~ 500 e / 300 100 e' -100 + (. 01-01-93 07-02 93 12 31-93 07-01 94 12-30 94 l Figure 14. Quarterly composites of weekly collections. ( 169 j

Oo Surface Water-Tritium i1 BY-13(C) Rock River, Upstream 500 400 l 300 a 200 100 f. x,/ / e 0 -100 01 01 93 07-02 93 12 31-93 07-01-94 12 30-94 g Figure 15. Quarterly composites of weekly conections. B I BY-29(C) Byron, Upstream 500 400 300 .a 200 100 \\ --.x, -100 f 01 01 93 07-02 93 12 31 93 07-01-94 12 30-94 Figure 16. Quarterly composites of weekly collections. I 170

L Well Water-Tritium BY-14 CECO Offsite Well i 500 7 400 300 a D 200 R E ./ j ./ s '. ,.g,'../ ' ' \\,.' N./ l i / -100 01 01 93 07-02 93 12-31-93 07-01-94 12-30-94 i Figure 17. Monthly collections. BY-18 McCoy Farmstead Well I i 500 400 l l 300+ l [ ld i 200, l 1* J \\. * - *\\

s.,x. -.,[.
  • / x,..

i x. y i 0 E s. 1 x. -100 -+ 01-01-93 07-02 93 12 31 93 07-01-94 12-30-94 Figure 18. Monthly collections. ( 171

u u L rL rL APPENDIX IV b INTERLABORATORY COMPARISON PROGRAM RESULTS f~L u r L [ r L b [ [ [ { 172

Appendix A Interlaboratory Com_p2mfarrogram Results Teledyne Brown Engineering Environmental Services, Midwest Laboratory (formerly Teledyne Isotopes and Hazelton Environmental Services) has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are I operated by agencies which supply environmental type samples (e.g., milk or water) containing concentrations of radionuclides know to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on the laboratory's analytical procedures and to alert 3 it to any possible problems. 3 I Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used. The results in Table A-1 were obtained through participation in the environmental sample crosscheck

I program for milk, water, air filters, and food samples during the current year. This program is conducted by the U.S. Environmental Protection Agency Intercomparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, Las Vegas, Nevada.

I Table A-2 lists results of the analyses on in-house " spiked" samples. Table A-3 lists results of the in-house " blank" samples. Table A-4 lists results of the in-house " duplicate" program. Out-of limit results are explained directly below the result. I I 173

f l i ' Tcbir A-1. U.S. Environmental Protection Agency's crosscheck program, comparison of EPA and Teledyne Brown Engineering Environmental Services, Midwest Laboratory results for various sample media'. Concentration in pCi/LS Lcb Samp!c Date EPA Result' Control TBEESML Results I Code Type Collected Analysis 1s, N=1 Limits i 2 Sigmad STW-702 WATER Jan,1994 Sr-89 25.015.0 16.3 - 33.7 20.0 i l.7; 2.6 l l STW-702 WATER Jan,1994 Sr-90 15.015.0 6.3 - 23.7 14.011.0;1.7 ) [ STW-703 WATER Jan,1994 Gr. Alpha 15.015.0 6.3 - 23.7 20.3 0.6; 2.5 STW-703 WATER Jan,1994 Gr. Seta 62.0 i 10.0 44.7 - 79.3 55.313.2;9.1 l STW-704 WATER Feb,1994 I-131 119.0 i 12.0 98.2 - 139.8 110.0 1 2.7;11.3 STW-705 WATER Feb,1994 Ra-226 19.913.0 14.7 - 25.1 19.411.5;2.5 l STW-705 WATER Feb,1994 Ra-228 14.713.7 8.3 - 21.1 15.010.8;1.7 STW 705 WATER Feb,1994 Uranium 10.113.0 4.9 - 15.3 9.7i 0.4 ; 1.0 f STW-706 WATER Mar,1994 H-3 4936.0 i 494.0 4078.9 - 5793.1 4843.3 1 231.2;698.1 STW-707 WATER Mar,1994 Pu-239 27.612.8 22.7 - 32.5 28.2 i 0.9;3.0 l STW-708 WATER Apt,1994 Gr. Alpha 86.0122.0 47.8 - 124.2 73.3 i 2.9;9.4 STW-708 WATER Apr,1994 Ra-226 20.013.0 14.8 - 25.2 16.9 t l.2 ; 2.1 i STW-708 WATER Apr,1994 Ra-228 20.115.0 11.4 - 28.8 19.710.7;2.1 STW-708 WATER Apr,1994 Uranium 25.013.0 19.8 - 30.2 25.1 0.1 ; 2.5 STW-709 WATER Apr,1994 Co-60 20.015.0 11.3 - 28.7 20.3 0.6; 3.0 STW 709 WATER Apr,1994 Cs-134 34.0 i 5.0 25.3 - 42.7 32.310.6;4.7 STW-709 WATER Apr,1994 Cs-137 29.0 5.0 20.3 - 37.7 31.3 0.6 ; 4.5 STW-709 WATER Apr,1994 Gr. Beta 117.0 1 18.0 85.8 - 148.2 101.0 1 10.5;18.8 STW-709 WATER Apr,1994 Sr-89 20.015.0 11.3 - 28.7 15.011.7;2.3 STW-709 WATER Apr,1994 Sr-90 14.015.0 5.3 - 22.7 14.310.6;1.6 STW 710 WATER Jun,1994 Ba-133 98.0110.0 80.7 - 115.3 87.310.6;12.6 STW-710 WATER Jun,1994 Co-60 50.015.0 41.3 - 58.7 48.7 3.2 ; 7.7 STW-710 WATER Jun,1994 Cs-134 40.015.0 31.3 - 48.7 35.012.7;5.7 STW-710 WATER Jun,1994 Cs-137 49.015.0 40.3 - 57.7 51.310.6;7.4 174

O_ O~ Tcble A-1. U.S. Environmental Protection Agency's crosscheck program, comparison of EPA and Teledyne Brown Engineering Environmental Services, Midwest Laboratory results for various sample media *. Concentration in pCi/L' Lab Sample Date EPA Result' Control TBEESML Results Code Type Collected Analysis 1s, N=1 Limits i 2 Sigmad STW-710 WATER Jun,1994 Ru-106 252.0 1 25.0-208.6 - 295.4 184.7 1 6.7;27.4 A Letter from the EPA was received with the report. It states, "The Radiation Quality Assurance Program has been experiencing problems with the Ruthenium-1% currently used in the Performance Evaluation (PE) Studies and in the Standards Distribution Program. If these problems can be satisfactorily resolved, this analyte will once again be placed into this PE Study. If the problems cannot be resolved, the Ruthenium-106 will be replaced. Formal written notice will be given to all participants in the Gamma in Water PE Study before the Ruthenium-1% is reintroduced or replaced. At that time, new calibration standards will be available to all participants in the Gamma in Water PE Study." Teledyne will continue to monitor this situation, but at this time, plans to take no additional action. STW-710 WATER Jun,1994 Zn-65 134.0 1 13.0 111.4 - 156.6 135.3 1 2.3;19.6 STW-711 WATER Jun,1994 Ra-226 15.012.3 11.0 - 19.0 15.0 0.4 ; 1.6 STW-711 WATER Jun,1994 Ra-228 15.413.9 8.6 - 22.2 14.810.3;1.5 STW-711 WATER Jun,1994 Uranium 52.615.3 43.4 - 61.8 45.710.2;4.6 STW-712 WATER Jul,1994 Sr-89 30.015.0 21.3 - 38.7 26.011.7;3.1 STW 712 WATER Jul,1994 Sr-90 20.015.0 11.3 - 28.7 18.710.6;2.0 STW-713 WATER Jul,1994 Gr. Alpha 32.0 i 8.0 18.1 - 45.9 19.311.2;2.6 STW-713 WATER Jul,1994 Gr. Beta 10.0 5.0 1.3 - 18.7 12.711.5;2.5 STW 714 WATER Aug,1994 H-3 9951.0 i 995.0 8224.7 - 11677.3 10186.7 66.6;1387.0 I l STAF-715 AIR FILTER Aug,1904 Cs-137 15.0 5.0 6.3 - 23.7 14.0-1 0.0;1.4 STAF-715 AIR FILTER Aug,1994 Gr. Alpha 35.019.0 19.4 - 50.6 29.311.2;3.2 STAF-715 AIR FILTER Aug,1994 Gr. Beta 56.0110.0 38.7 - 73.3 56.010.0;5.6 STAF-715 AIR FILTER Aug,1994 Sr-90 20.015.0 11.3 - 28.7 18.0 1.0 ; 2.1 STW-716 WATER Sep,1994 Ra-226 10.0 i 1.5 7.4 - 12.6 10.110.3;1.1 STW-716 WATER Sep,1994 Ra-228 10.212.6 5.6 - 14.7 9.810.1;1.0 STW-716 WATER Sep,1994 Uranium 35.013.0 29.8 - 40.2 31.9 1.8 ; 3.7 STW-718 WATER Oct,1994 I-131 79.0 i 8.0 65.1 - 92.9 81.313.1;8.7 l ~ I 175 E =

I I Tcble A-1. U.S. Environmental Protection Agency's crosscheck program, comparison of EPA and Teledyne Brown Engineering Environmental Services, Midwest Laboratory results for various sample media *. Concentration in pCi/L6 Lab Sample Date EPA Result' Control TBEESML Results Code Type Collected Analysis 1s, N=1 Limits i 2 Sigma d

  • Results obtained by Teledyne Brown Engineering Environmental Services Midwest Laboratory as a participant in the environmental sample crosscheck program operated by the Intercomparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, U.S. Environmental Protection Agency l

(EPA), Las Vegas, Neveda.

  • All results are in pCi/L, except for elemental potassium (K) data in milk, which are in mg/L; air filter I

' samples, which are in pCi/ Filter; and food products, which are in mg/Kg. USEPA results are presented as the known values and expected laboratory precision (1s,1 determination) and control limits as defined by the EPA. d Unless otherwise indicated, the TBEESML results are given as the mean 2 standard deviations for three j determinations. The numbers after the semi-colon are the Total Propagated Uncertainty of the result. l I l 1 I I i I I I I 1/6 I

{ 1 Tcbl2 A-2. In-house " spike" samples. l Concentration in pCi/L' ( L:b Sample Da te Accepted Known TBEESML Results ( Code Type Collected Analysis Rejected Activity Control Limits" 2s, n=1' SPW-4821 WATER Jan,1994 Ce-144 A 2692.5 2158.2-3226.8 2593.1 1 54.9;265.1 f SPW-4822WATER Jan,1994 Ce-144 A 1749.8 1397.7-2101.9 1705.1 1 48.1;177.2 SPW-4823 WATER Jan,1994 Ce-144 A 49.0 25.7-72.3 55.4 1 17.5;18.4 SPW-4825 WATER Jan,1994 Gr. Alpha A 41.7 33.7-49.7 34.411.6;3.8 SPW-4825 WATER Jan,1994 Gr. Beta A 30.2 23.6-36.8 33.6 i 1.2;3.6 SPW-4826 WATER Jan,1994 Gr. Alpha R 83 4 68.1-98.7 66.8 i 2.1;7.0 ( A review of the raw data for the Alpha analysis revealed no errors in calculations or transcribing of data. The technician was observed performing this analysis; no discrepancies where noted. The technician's performance in the future will be monitored. It should be noted that TBEESML's results are within the EPA specified control limits. No further action is planned. SPW-4826 WATER Jan,1994 Gr. Beta A 60.4 47.8-73.0 63.811.5;6.6 SPMI-4848 MILK Jan,1994 Cs-134 A 31.7 22.2-41.2 27.215.7;6.3 SPMI-4848 MILK Jan,1994 Cs-137 A 34.8 22.4-47.2 34.6 i 8.2; 8.9 SPMI-4848 MILK Jan,1994 Sr-89 A 35.0 26.8-43.2 28.213.8;4.7 SPMI-4848 MILK Jan,1994 Sr-90 A 40.7 32.3-49.1 41.211.2;4.3 SPMI-4849 MILK Jan,1994 Sr-89 A 11.9 8.8-15.0 9.511.6;1.9 SPMI-4849 MILK Jan,1994 Sr-90 A 20.1 16.0- 24.2 19.410.8;2.1 SPMI-4862 MILK Jan,1994 Cs-134 A 338.0 267.5-408.5 328.3 1 16.3;36.7 SPMI-4862 MILK Jan,1994 Cs-137 A 1114.4 899.4 - 1329.4 1019.6 1 18.3;103.6 SPAP-4953 AIR FILTER Jan,1994 Gr. Beta A 4.2 3.3 - 5.1 4.810.1;0.5 SPAP-4954 AIR FILTER Jan,1994 Cs-137 A 1.3 1.0- 1.6 1.410.1;0.2 SPW-4955 WATER Jan,1994 11-3 A 17163.0 13700.3-20625.7 17080.0 1 364.0;1746.4

SPW-4956 WATER Jan,1994 Co-60 A

1545.0 1232.2-1857.8 1514.0 46.2;158.3 SPW-4956 WATER Jan,1994 Cs-134 A 4 79.0 380.8-577.2 433.7 1 25.5;50.3 2PW-4956 WATER Jan,1994 Cs-137 A 732.0 571.5-892.5 742.71 45.9;87.3 SPCli-492 CHARCOAL Feb,1994 I-131(g) A 1452.8 1148.6-1757.0 1449.9 1 65.1;158.9 CANISTER. SPW-4934 WATER Feb,1994 I-131 A 90.8 74.0- 107.6 76.4 i l.4 ; 7.8 SPW-4934 WATER Feb,1994 I-131(g) A 90.8 69.9-111.7 90.217.6;11.8 SPMI-4935 MILK Feb,1994 I-131 A 43.6 35.1-52.1 40.411.0;4.2

PMI 4935 MILK Feb,1994 1-131(g)

A 43.6 31.3-55.9 41.816.7;7.9 sPBS-5102 SEDIMENT Mar,1994 11-3 A 105.4 85.1-125.7 97.2 1.0 ; 9.8 BPW-5146 WATER Mar,1994 Sr-89 A 26.4 19.1-33.7 25.5 3.9 ; 4.7 sPW-5146 WATER Mar,1994 Sr-90 A 18.8 15.0- 22.6 16.211.1;2.0 FPW-646 WATER Apr,1994 11-3 A 9855.0 7841.5-11868.5 9847.8 294.9;1028.0

PW-648 WATER Apr,1994 Co-60 A

22.6 13.4-31.8 21.6 6.6 ; 6.9 177

O O Table A-2. In-house " spike" samples. Concentration in pCi/L' Lab Sample Date Accepted Known TBEESML Results Code Type Collected Analysis Rejected Activity Control limits 6 2s, n=1' SPW-648 WATER Apr,1994 Cs-134 A 33.6 21.1-46.1 33.3 8.5;9.1 SPW-648 WATER Apt,1994 Cs-137 A 36.3 22.2-50.4 37.619.8;10.5 E SPMl-650 MILK Apr,1994 Cs-134 A 50.6 38.1-63.1 52.015.3;7.4 5 SPMI-650 MILK Apr,1994 Cs-137 A 54.5 38.7-70.3 61.618.3;10.3 SPW-652 WATER Apr,1994 Gr. Alpha A 41.6 32.8-50.4 44.811.2;4.6 SPW-652 WATER Apr,1994 Gr. Beta A 25.4 20.3-30.5 24.111.0;2.6 SPAP-654 AIR FILTER Apr,1994 Cs-137 A 1.3 1.0- 1.6 1.310.1;0.2 SPW-974 WATER May,1994 Fe-55 A 58.5 39.4 - 77.6 56.7 12.0;13.3 SPF-1023 FISli May,1994 Cs-137 A 6.8 5.4 - 8.2 6.910.1;0.7 (JELLO) SPBS-1024 SEDIMENT May,1994 Cs-137 A 6.0 4.8 - 7.2 6.2 i 0.1 ; 0.6 SPW-1850 WATER Jun,1994 I-131 A 51.8 42.0- 61.6 46.010.7;4.7 SPW-1850 WATER Jun,1994 I-131(g) A 51.8 36.9-66.7 50.9 i 8.3;9.7 SPMI-1851 MILK Jun,1994 I-131 A 51.8 41.4-62.2 51.710.6;5.2 SPMI-1851 MILK Jun.1994 I-131(g) A 51.8 34.7-68.9 51.3 1 10.8;12.0 SPVE-1854 VEGETATIO Jun,1994 I-131(g) A 1.0 0.8 - 1.2 0.910.1;0.1 N (SAWDUST) SPCll-185 CliARCOAL Jun,1994 I-131(g) A 1.8 1.4 - 2.2 1.910.1;0.2 CANISTER SPW-3278 WATER Jun,1994 Gr. Alpha A 23.4 18.7-28.1 20.8 i l.1 ; 2.4 SPW-3278 WATER Jun,1994 Gr. Beta A 31.8 25.5-38.1 29.511.1;3.1 SPW-3276 WATER Jul,1994 II-3 A 25019.0 20030.6-30007.4 24504.6 1 421.7;2486.5 SPMI-3282 MILK Jul,1994 Sr-89 A 22.5 15.2-29.8 16.414.8;5.1 SPMI-3282 MILK Jul,1994 Sr-90 A 25.4 20.0- 30.8 25.311.4;2.9 SPW-3284 WATER Jul,1994 Cs-137 A 221.5 168.5-274.5 240.8 1 19.3;30.9 g SPAP-3388 AIR FILTER Jul,1994 Gr. Beta A 8.3 6.7-9.9 7.9 0.1 ; 0.8 E SPAP-3390 AIR FILTEi( Jul,1994 Cs-137 A 1.3 1.0- 1.6 1.310.1;0.2 SPF-3603 FISH Jul,1994 Cs-137 A 8.5 6.1-10.9 8.3 1.3 ; 1.5 (JELLO) SPW-5549 WATER Oct,1994 I-131 A 79.9 64.1 - 95.7 77.410.9;7.8 SPW-5549 WATER Oct,1994 1-131(g) A 79.9 59.1-100.7 85.519.5;12.8 SPMI-5550 MILK Oct,1994 Cs-134 A 36.4 25.8-47.0 35.016.0;6.9 SPMI-5550 MILK Oct,1994 Cs-137 A 44.1 29.2-59.0 46.119.4;10.5 g SPMl-5550 MILK Oct,1994 I-131 A 63.9 50.9-76.9 65.210.9;6.6 E SPMI-5550 MILK Oct,1994 1-131(g) A 63.9 44.5-83.3 68.4 11.1;13.0 SPW-5594 WATER Oct,1994 I-131 A 95.8 76.9-114 7 92.5 i l.0 ; 9.3 178 5.

E Tcble A-2. In-house " spike" samples. E Concentration in pCi/L' { Lab Sample Date Accepted Known TBEESML Results Code Type Collected Analysis Rejected Activity Control limits 6 2s, n=1' SPW 5594 WATER Oct,1994 I-131(g) A 95.8 72.1-119.5 98.2 10.1;14.1 { SPVE-6067 VEGETATIO Oct,1994 1-131(g) A 1.6 1.2 - 2.0 1.710.1;0.2 I N (SAWDUST) ! SPS-5946 SEDIMENT Oct,1994 Cs-134 A 0.3 -23.9-24.6 0.3 i 24.2;24.2 ) (BOTTOM) I SPF-6208 { FISH Oct,1994 Cs-137 A 12.1 9.7-14.4 11.6 0.1 ; 1.2 { (JELLO) SPW-6955 WATER Nov,1994 Ni-63 A 1931.0 1549.6-2312.4 1851.6 34.3;188.3 i SPW-6994 WATER Nov,1994 Tc-99 A 66.0 49.3-82.6 63.2 i 7.8;10.0 SPW-7440 WATER Nov,1994 H-3 A 24260.0 19387.1-29132.9 24099.2 i 423.9;2446.9 SPAP-7507 AIR FILTER Nov,1994 Cs-137 A 1.9 1.5 - 2.3 2.2 0.0 ; 0.2 l l

  • All results are in pCi/L, except for elemental potassium (K) data in milk, which are in mg/L.; air filter samples, I
  • which are in pCi/ Filter; and food products, which are in mg/Kg.

Control limits are based on the known value i 10 TPU (Where all parametric uncertainties, other than counting l statistics, are less than 5%).

  • All samples are the results of single determinations. The result is reported in the following format:

Activity i Counting Error ; Total Propagated Uncertainty. lI iI 1I iI 179

E Table A-3. In-house " blank" samples. b Concentration pCi/L'. Teledyne Results Acceptance Lab Sample Sample (4.66 Sigma) Criteria Code Type Da te Analysis LLD Activity" (4.66 Sigma) SPW-4820 WATER Jan 1994 Cs-134 < 1.9 -1.76 1 7.24;7.24 < 10.0 SPW-4820 WATER Jan 1994 Cs-137 <4.4 -0.31 1 2.67;2.67 < 10.0 SPW-4824 WATER Jan 1994 Gr. A1pha <0.3 0.00 i 0.20;0.20 < 1.0 SPW-4824 WATER Jan 1994 Gr. Beta <0.9 0.40 1 0.59:0.59 < 3.2 SPW-4827 WATER Jan 1994 Co-60 < 1.8 1.10 i 1.04;1.05 < 10.0 SP"4 4827 WATER Jan 1994 Cs-134 < 1.9 0.51 i 6.76;6.76 < 10.0 SPW-4827 WATER Jan 1994 Cs-137 <2.0 0.43 i 0.84;0.84 < 10.0 SPW 4827 WATER Jan 1994 Gr. Alpha <0.4 0.121 0.25;0.25 < 1.0 SPW-4827 WATER Jan 1994 Gr. Beta < 0. 8 0.21 1 0.55;0.55 <3.2 SPW-4827 WATER Jan 1994 H-3 <192.0 133.90 1 101.00;102.63 < 200.0 SPW-4827 WATER Jan 1994 1-131 <0.3 -0.12 1 0.14;0.14 <0.5 SPMI-4846 MILK Jan 1994 Co-60 <3.6 0.62 1 2.67;2.67 < 10.0 SPMI-4846 MILK Jan 1994 Cs-134 <5.4 0.52 i 3.83;3.83 < 10.0 SPMI-4846 MILK Jan 1994 Cs-137 < 3. 4 -0.74 i 2.93;2.93 < 10.0 SPMI-4846 MILK Jan 1994 I-131 <0.5 0.27i 0.34;0.34 <0.S SPMI-4846 MILK Jan 1994 Sr-89 <0.5 -0.54 i 0.79;0.79 < 5.0 SPMI-4846 MILK Jan 1994 Sr-90 N/A 1.93 i 0.44;0.48 < 1.0 tow level of Sr-90 concentration in milk (1-5 pCi/L) is not unusual. SPAP-4950 AIR FILTER Jan 1994 Co-60 <2.2 -2.61 1 2.19;2.21 < 10.0 { SPAP-4950 AIR FILTER Jan 1994 Cs-134 <3.1 -0.31 i 3.65;3.65 < 10.0 SPAP-4950 AIR FILTER Jan 1994 Cs-137 <2.9 2.78 1 23.94;23.94 <10.0 SPAP-4952 AIR FILTER Jan 1994 Gr. Beta <0.9 0.00 i 0.58;0.58 <3.2 SPCH-4951 CHARCOAL Feb 1994 I-131(g) < 7.0 0.64 i 4.80;4.80 < 9.6 CANISTER SPW-5054 WATER Mar 1994 Ra-226 <0.1 0.01 i 0.03:0.03 < 1.0 SPW 5054 WATER Mar 1994 Ra-228 < 1.0 0.54 1 0.67;0.67 < 1.0 SPBS-5101 SEDIMENT Mar 1994 Co-60 <5.9 -0.19 1 1.63;1.63 < 10.0 SPBS-5101 SEDIMENT Mar 1994 Cs-134 <6.2 -31.20 i 13.10;13.47 < 10.0 SPBS-5101 SEDIMENT Mar 1994 Cs-137 <4.4 -0.26 i 2.75;2.75 < 10.0 SPW-647 WATER Apr 1994 Co-60 <5.8 0.56 i 0.53;0.54 < 10.0 SPW-647 WATER Apr 1994 Cs-134 <3.4 0.86 1 0.72;0.73 < 10.0 SPW-647 WATER Apr 1994 Cs-137 <5.1 2.65 i 2.75 2.78 < 10.0 { SPW-647 WATER Apr 1994 H-3 <191.5 148.40 i 100.90;102.90 < 200.0 SPW-647 WATER Apr 1994 I 131 <0.5 -0.34 1 0.22;0.22 <0.5 SPM1-649 MILK Apr 1994 Co-60 <6.5 0.55 1.39;1.39 < 10.0 180

O O Table A-3. In-house " blank" samples. Concentration pCi/L'. Teledyne Results Acceptance Lab Sample Sample (4.66 Sigma) Criteria Code Type Date Analysis LLD Activity" (4.66 Sigma) SPMI-649 MILK Apr 1994 Cs-134 < 3. 4 -3.45 5.60;5.62 < 10.0 SPMI-649 MILK Apr 1994 Cs-137 <4.6 0.59 1 3.98;3.98 < 10.0 SPMI-649 MILK Apr 1994 I-131 <0.5 -0.11 1 0.19;0.19 <0.5 SPW-651 WATER Apr 1994 Gr. Alpha <0.4 0.14 i 0.25;0.25 < 1.0 SPW-651 WATER Apr 1994 Gr. Beta < 0. 8 0.12 0.54;0.54 < 3.2 SPAP-653 AIR FILTER Apr 1994 Cs-134 < 2.1 -0.12 i 0.18;0.18 < 10.0 SPAP-653 AIR FILTER Apr 1994 Cs-137 <3.4 1.05 1.55;1.55 < 10.0 SPCH-654 CHARCOAL Apr 1994 I-131(g) < 6.1 0.96 1 3.84;3.84 < 9.6 CANISTER SPAP-4956 AIR FILTER Apr 1994 Gr. Beta < 1.0 0.32 1 0.96;0.96 < 3.2 SPW-974 WATER May 1994 Fe-55 < 0. 8 0.101 0.47;0.47 < 1000.0 SPF-1022 FISH OELLO) May 1994 Cs-134 < 9. 2 12.70 1 31.70; 31.73 < 10.0 SPF-1022 FISH OELLO) May 1994 Cs-137 < 10.0 27.30 1 58 30;58.36 < 10.0 SPW-1075 WATER May 1994 Ra-226 < 0.1 0.01 1 0.04;0.04 <1.0 SPBS-3254 SEDIMENT May 1994 Co-60 <5.8 5.93 1 8.06;8.08 < 10.0 SPBS-3254 SEDIMENT May 1994 Cs-134 <2.0 5.67 6.69;6.71 < 10.0 SPBS-3254 SEDIMENT May 1994 Cs-137 <5.0 -2.11 1 4.69;4.69 < 10.0 SPVE-1852 VEGETATION Jun19% Cs-134 <5.4 -1.47 i 2.14;2.15 < 10.0 (SAWDU 3T) SPVE-1852 VEGETATION Jun19% Cs-137 <6.6 2.12 i 3.44;3.45 < 10.0 (SAWDUST) SPVE-1852 VEGETATlON Jun1994 1-131(g) < 5. 6 -0.73 1.08;1.08 < 20.0 (SAWDUST) SPW-3277 WATER Jun1941 Gr. Alpha <0.3 0.10 1 0.22;0.22 < 1.0 SPW-3277 WATER Jun 1994 Gr. Deta < 0. 8 0.14 1 0.54;0.54 < 3.2 SPW-3275 WATER Ju11994 H-3 <154.9 22.81 1 77.81; 77.87 < 200.0 E SPMI-3281 MILK Jul1994 Co-60 < 3. 6 0.871 2.22;2.22 < 10.0 5 SPMI-3281 MILK Jul1994 Cs-134 <2.3 -0.451 2.61;2.61 < 10.0 SPMI-3281 MILK Jul1994 Cs-137 <4.2 0.071 2.28;2.28 < 10.0 SPMI-3281 MILK Jul1994 1-131 < 0. 2 0.101 0.16;0.16 <0.5 SPMI 3281 MILK Jul1994 Sr-89 < 0. 9 -0.54 1 1.32;1.32 < 5.0 SPMI-3281 MILK Jul1994 Sr-90 N/A 2.29 1 0.56;0.61 < 1.0 Low level of Sr-90 concentration in milk (1-5 pCi/L) is not unusual. SPW-3283 WATER Jul1994 Co-60 <2.2 -3.09 1 3.52;3.55 < 10.0 SPW-3283 WATER Jul1994 Cs-134 <5.4 0.791 3.13;3.13 < 10.0 181 Ea

i Table A-3. In-house " blank" samples. Concentration pCi/L'. Teledyne Results Acceptance [ Lab Sample Sample (4.66 Sigma) Criteria L Code Type Da te Analysis LLD Activity * (4.66 Sigma) SPW-3283 WATER Jul1994 Cs-137 < 5. 0 -0.10 1 3.05:3.05 < 10.0 ( SPW-3283 WATER Jul1994 I-131 < 0. 4 0.14 1 0.22:0.22 < 0.5 SPAP-3389 AIR FILTER Jul 1994 Gr. Beta < 0. 2 0.16 i 0.26;0.26 <3.2 SPAP-3391 AlR FILTER Jul 1994 Co-60 <1.7 -0.74 i 1.44;1.44 < 10.0 SPAP-3391 AIR FILTER Jul 1994 Cs-134 <2.3 0.95 1 4.86;4.86 < 10.0 SPAP-3391 AIR FILTER Jul 1994 Cs-137 <4.1 -3.03 1 3.15;3.16 < 10.0 { SPF-3602 FISH GELLO) Jul1994 Co-60 <3.6 -4.451 4.27;4.29 < 10.0 SPF-3602 FISH OELLO) Jul1994 Cs-134 <4.1 -3.911 5.63;5.64 < 10.0 SPF-3602 FISH (JELLO) Jul1994 Cs-137 <4.7 -5.171 5.80;5.82 < 10.0 p L SPMl-5551 MILK Oct 1994 Cs-134 <4.3 0.90 3.34; 3.34 < 10.0 SPMI-5551 MILK Oct 1994 Cs-137 < 4.1 -0.55 1 3.43;3.43 < 10.0 1 { SPMI 5551 MILK Oct 1994 I-131 <0.2 -0.031 0.16;0.16 <0.5 SPSO-5947 SOIL Oct 1994 Cs-134 <2.3 -4.84 i 4.84;4.86 < 10.0 SPSO-5947 SOIL Oct 1994 Cs-137 <6.4 -0.50 1 4.71:4.71 < 10.0 SPW-6995 WATER Nov l994 Tc-99 <4.2 1.24 1 2.19;2.19 < 10.0 SPW-7441 WATER Nov l994 H-3 <169.0 -74.64 80.48;81.12 < 200.0 I SPW-7442 WATER Nov l994 H-3 <169.0 -37.021 82.14;82.29 < 200.0 SPW-7451 WATER Nov 1994 Gr. Alpha <0.3 0.11 1 0.19;0.19 < 1.0 SPW-7451 WATER Nov 1994 Gr. Beta < 0.8 0.101 0.52;0.52 <3.2 SPAP-7506 AIR FILTER Nov 1994 Co-60 <2.1 0.171 1.63;1.63 < 10.0 SPAP-7506 AIR F1LTER Nov 1994 Cs-134 < 1.6 -1.08 1 1.70;1.70 < 10.0 SPAP-7506 AIR FILTER Nov 1994 Cs-137 <3.0 -0.55 1 1.65;1.65 < 10.0 ' Liquid sample results are reported in pCi. Liter, air filter sample results are in pCi/ filter, charcoal sample results are in pCi/ charcoal, and solid sample results are in pCi/ kilogram. (

  • The activity reported is the net activity result.

l l l l l l 182 l

Table A-4. In-house "d uplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes Rejected Result Result 6 Jm,1994 Gr. Beta WATER-4M7, 4608 A 1.410.7;0.7 1.410.7;0.7 Jan,1994 Co-60 MILK-166,167 A 1.413.7;3.7 -1.1 i 4.3 ; 4.3 Jan,1994 Cs-137 MILK-166,167 A -0.3 i 3.4 ; 3.4 -0.712.6;2.6 Jm,1994 1-131(G) MILK-166,167 A -0.110.2;0.2 0.210.2;0.2 J.n,1994 Gr. Deta WATER-4711,4712 A 1.710.6;0.7 1.8 i 0.6 ; 0.7 I jan,1994 Co-60 MILK-187,188 A 0.1 i 2.9 ; 2.9 -1.413.4;3.4 Jm,1994 Cs-137 MILK-187,188 A 0.211.9;1.9 1.912.6;2.6 J:n,1994 1131 MILK-187,188 A 0.2 i 0.2 ; 0.2 0.110.2;0.2 Jan,1994 Gr. Beta WATER-4664, 4665 A 8.8 i 1.8 ; 2.3 4.4 i 1.4 ; 1.6 Jan,1994 H-3 WATER-4664, 4665 A 93.0 1 95.9;96.7 37.21 93.6;93.8 Jan,1994 Gr. Alpha WATER-4687,4688 A 1.6 i 1.5 ; 1.5 0.011.2;1.2 Jin,1994 Gr. Beta WATER-4687,4688 A 3.210.8;1.0 2.510.8;0.9 Jan,1994 H-3 WATER-4687, 4688 A 171.8 1 99.0;101.7 183.4 1 99.4;102.5 I jan,1994 H-3 WATER-4741,4742 A 105.0 i 101.0;102.0 127.0 i 102.0;103.5 Jan,1994 K-40 MILK-208,209 A 1,396.0 1 148.0;240.7 1,586.0 i 162.0;269.8 Jan,1994 Sr-90 MILK-208, 209 A 3.010.6;0.6 3.610.7;0.8 Jan,1994 H-3 WATER-4830,4831 A 73.8 1 89.4;89.9 79.3 i 89.6;90.2 Jan,1994 Gr. Beta WATER-4865, 4866 A 1.910.2;0.4 1.910.2;0.3 Jan,1994 Gr. Deta WATER-5052,5053 A 2.210.6;0.6 2.6 i 0.6 ; 0.7 Jan,1994 H-3 WATER-4890,4891 A 421.9 1 109.0;123.2 454.8 1 106.6;123.2 Jan,1994 Gr. Beta WATER-4919,4920 A 2.8 0.8 ; 0.9 3.410.8;1.0 Feb,1994 Gr. Deta WATER-4952, 4953 A 2.710.6;0.7 2.1 0.5 ; 0.6 Feb,1994 H-3 WATER-5010, 5011 A 142.0 1 99.0;100.9 119.0 98.0;99.3 Feb, F94 K-40 MILK-250, 251 A 1,087.0 i 77.0;166.7 1,036.0 i 98.0;171.6 Feb,1994 Sr-90 MILK-250, 251 A 3.710.6;0.7 4.110.6;0.7 I Feb,1994 K-40 MILK-271, 272 A 1,510.0 1 90.0;224.2 1,520.0 1 110.0;234.2 Feb,1994 H-3 WATER-4978,4979 A 83.8 i 57.0;97.6 69.8 i 96.4;96.9 IFeb,1994 Co-60 MILK-229, 230 A -1.5 4.2 ; 4.2 -1.6 i 5.5 ; 5.5 Feb,1994 Cs-137 MILK-229, 230 A -0.7 i 3.1 ; 3.1 -2.013.7;3.7 Feb,1994 1-131 MILK-229, 230 A 0.2 0.2 ; 0.2 0.110.2;0.2 Feb,1994 H3 WATER-5081,5082 A 28.0 95.0;95.1 72.0 1 96.0;96.5 Feb,1994 H-3 WATER-5124, 5125 A 465.8 i 113.7;130.1 358.0 i 109.8;120.1 Feb,1994 Gr. Beta WATER-5212, 5213 A 2.910.7;0.8 2.210.6;0.7 Feb,1994 Co-60 WATER-5183,5184 A 1.5 i 1.6 ; 1.7 -0.712.0;2.0 Feb,1994 Cs-137 WATER-5183, 5184 A 0.3 i l.6 ; 1.6 0.412.1;2.1 Feb,1994 Gr. Beta WATER-5183, 5184 A 4.911.1;1.3 4.511.1;1.3 183 I

E> 0 Table A-4. In-house " duplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes Rejected Result Result 6 Mar,1994 K-40 MILK-292, 293 A 1,377.0 i 85.0;205.7 1,364.0 100.0;210.7 Mar,1994 5r-90 MILK-292, 293 A 1.2 i 0.4 ; 0.4 1.510.4;0.4 Mar,1994 Gr. Beta MILK-5246,5247 A 6.510.8;1.1 6.410.9;1.1 Mar,1994 Gr. Beta WATER-5270,5271 A 3.311.0;1.1 2.8 i 1.0 ; 1.1 Mar,1994 H-3 WATER-5293,5294 A 620.2 1 118.7;145.6 582.3 1 117.5;141.7 Mar,1994 1-131(G) MILK-313, 314 A 1.3147.7;47.7 -0.310.8;0.8 Mar,1994 K-40 MILK-334, 335 A 1,392.0 95.0;211.8 1,437.0 1 115.0;226.8 Mar,1994 H-3 WATER-5400,5401 A 77.7 i 97.2;97.8 66.8 1 96.5;97.0 g Mar,1994 H-3 WATER-5485,5486 A 336.0 1 107.0;116.3 272.0 1 105.0;111.3 3 Mar,1994 Co-60 WATER-5446,5447 A 1.814.4;4.4 0.110.5;0.5 Mar,1994 Cs-137 WATER-5446, 5447 A 0.711.6;1.6 1.011.9;1.9 g Mar,1994 Gr. Beta WATER-5446, 5447 A 3.811.3;1.4 3.7 1.3 ; 1.4 5 Mar,1994 H-3 WATER-5510,5511 A 396.0 89.0;104.0 458.5 i 113.1;129.2 Mar,1994 Gr. Beta WATER-5538, 5539 A 2.6 0.6 ; 0.7 2.010.6;0.7 Mar,1994 H-3 WATER-5593,5594 A 139.9 1 101.1;102.9 169.4 1 101.8;104.3 Mar,1994 Co40 WATER-5614,5615 A 0.4 i 1.0 ; 1.0 0.212.2;2.2 Mar,1994 Cs-137 WATER-5614,5615 A 0.913.8;3.8 -0.412.6;2.6 Mar,1994 Gr. Beta WATER-5566,5567 A 2.8 i 0.5 ; 0.7 2.210.5;0.6 Mar,1994 Gr. Beta WATER-72, 73 A 1.610.5;0.6 1.5 i 0.5 ; 0.5 g Apr,1994 Gr. Beta WATER-49, 50 A 3.410.9;1.1 3.410.9;1.1 E Apr,1994 Gr. Beta WATER-102,103 A 2.010.5;0.6 2.110.5;0.6 Apr,1994 H-3 WATER-102,103 A 165.0 1 102.0;104.4 79.0 1 98.0;98.6 Apr,1994 Gr. Beta WATER-187,188 A 3.4 i 0.7 ; 0.8 3.210.6;0.8 Apr,1994 Co-60 MILK-246, 247 A 1.8 1.6 ; 1.6 1.811.6;1.6 Apr,1994 Cs-137 MILK-246, 247 A 0.1 i 1.9 ; 1.9 0.111.9;1.9 Apr,1994 1-131 MILK-246, 247 A 0 l i 0.2; 0.2 0.210.3;0.3 Apr,1994 Gr. Beta WATER-257, 258 A 3.310.7;0.9 3.310.8;0.9 g Apr,1994 Cs-137 WATER-267, 268 A 0.212.7;2.7 1.212.2;2.2 g Apr,1994 Gr. Beta. WATER-281, 282 R 15.712.0;3.2 30.412.6;5.4 A review of the raw data revealed no errors or discrepancies. Both samples were recounted. The results of the recounts were in agreement with the initial results. The sample was reanalyzed. The result of the reanalysis was 30.712.1 pCi/L. No further action is planned. Apr,1994 H-3 WATER-281, 282 A 381,181.0 1 1,740.0;51,869.8 378,406.0 1 1,733.0; 51,492.4 Apr,1994 Gr. Beta WATER-454, 455 A 3.312.1;2.2 3.712.2;2.3 Apr,1994 H-3 WATER-405, 406 A 65.9 1 98.2;98.6 62.0 1 98.1;98.4 Apt,1994 K-40 MILK-464, 465 A 1,630.0 1 130.0;257.0 1,589.0 1 162.0;270.1 g Apr,1994 H3 WATER-516, 517 A 37.6 1 95.0;95.1 69.3 1 95.8;96.2 E 4 184 I, =l

I Table A-4. In-house " duplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second 6 Collected Analysis Codes Rejected Result Result I Apr,1994 Cs-137 WATER-267, 268 A 0.2 i 2.7 ; 2.7 1.2 2.2 ; 2.2 Apr,1994 Gr. Beta WATER-616, 617 A 2.510.5;0.6 3.010.6;0.7 Apr,1994 H-3 WATER-616, 617 A 193.0 1 102.0;105.3 203.0 1 103.0;106.6 Apr,1994 Co-60 WATER-739, 740 A 0.8 i 11.4;11.4 0.310.4;0.4 Apr,1994 Cs-137 WATER-739, 740 A -0.313.6;3.6 0.813.2;3.2 Apr,1994 Cs-137 WATER-739, 740 A -0.313.6;3.6 0.813.2;3.2 I Apr,1994 Co-60 WATER-697,698 A 3.414.4;4.4 2.1 2.8 ; 2.8 Apr,1994 Gr. Beta WATER-697, 698 A 2.911.0;1.1 3.110.8;0.9 May,1994 Gr. Beta WATER-1003,1004 A 2.8 0.3 ; 0.5 2.610.3;0.5 May,1994 Gr. Beta WATER-796, 797 A 1.7 0.5 ; 0.5 2.1 0.5 ; 0.6 May,1994 H-3 WATER-931, 932 A 531.3 109.7;131.4 554.5 i 110.6;133.8 May,1994 Co-60 WATER-893, 894 A -1.5 i 4.1 ; 4.1 1.313.2;3.2 May,1994 Cs-137 WATER-893, 894 A 0.9 i 2.3 ; 2.3 1.513.1;3.1 Mry,1994 Gr. Beta WATER-893, 894 A 1.311.9;1.9 -0.211.8;1.8 Miy,1994 H-3 WATER-893, 894 A 159.0 i 95.6;98.0 118.3 i 94.0;95.4 M:y,1994 Co-60 MILK-900, 901 A -2.8 i 3.0 ; 3.0 -1.7i 6.1 ; 6.1 + MIy,1994 Cs-137 MILK-900, 901 A -0.1 1.3 ; 1.3 0.511.7;1.7 Miy,1994 I-131 MILK-900, 901 A 0.1 i 0.2 ; 0.2 0.110.2;0.2 May,1994 K-40 MILK-1001,1002 A 1,250.0 1 180.0;247.6 1,370.0 i 140.0;233.1 I Mzy,1994 Gr. BetaWATER-1171,1172 A 9.712.0;2.5 7.512.2;2.5 May,1994 H-3 WATER-1171,1172 A 950.0 1 108.0;168.4 1,012.0 1 109.0;175.6 May,1994 Co-60 MILK-1214,1215 A 0.7i 2.4 ; 2.4 0.2 i 0.6 ; 0.6 May,1994 Cs-137 MILK-1214,1215 A -0.411.5;1.5 1.411.8;1.8 May,1994 1-131 MILK-1214,1215 A 0.110.2;0.2 0.110.2;0.2 Mty,1994 Gr. Deta WATER-1565,1566 A 2.610.9;1.0 2.6 i 0.9 ; 1.0 May,1994 Gr. Beta WATER-1399,1400 A 6.010.7;1.1 5.5 i 0.7 ; 1.1 Msy,1994 I-131(G) MILK-1301,1302 A -0.110.2;0.2 0.010.2;0.2 May,1994 Gr. Beta SEDIMENTS-1550, A 2.110.1;0.2 2.210.1;0.2 May,1994 Gr. Beta WATER-1545,1546 A 6.610.6;1.2 5.4 i 0.6 ; 1.0 { May,1994 Co-60 WATER-1670,1671 A -0.3 i 0.6 ; 0.6 1.4 2.4 ; 2.4 May,1994 Cs-137 WATER-1670,1671 A 1.713.0;3.0 -1.712.6;2.7 ] Mzy,1994 I-131(G) MILK-1510,1511 A 0.110.1;0.1 -0.110.1;0.1 Mty,1994 H-3 WATER-1520,1521 A 48.4 1 97.3;97.5 79.9 i 98.5;99.1 Jun,,1994 I-131 MILK-1744,1745 R 0.9 i 0.2 ; 0.2 0.1 i 0.2 ; 0.2 Jun,1994 Gr. Beta WATER-1786,1787 A 31.4 i 3.1;5.8 31.413.0;5.7 l Jun,134 H-3 WATER-1786,1787 A 236,078.0 1 1,364.0;32,135.6 235,776.0 1 1,363.0; 32,094.5 I 185

3 r 0 Table A-4. In-house " duplicate" prograrn. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes

  • Rejected Result Result Jun,1994 Co-60 WATER-1843,1844 A

1.3 1.0 ; 1.0 0.5 i 2.2 ; 2.2 Jun,1994 Cs-137 WATER-1843,1844 A 0.0 i 1.1 ; 1.1 1.0 i 1.8 ; 1.8 Jun,1994 H-3 WATER-1843,1844 A 138.71 79.6;81.8 69.6 i 76.7; 77.3 Jun,1994 Co-60 MILK-1818,1819 A -1.313.1;3.1 0.214.5;4.5 Jun,1994 Cs-137 MILK-1818,1819 A 0.3 i 2.3 ; 2.3 1.9 i 3.5 ; 3.5 Jun,1994 I-131(G) MILK-1818,1819 A -0.210.2;0.2 0.010.1;0.1 Jun,1994 Gr. Beta WATER-1882,1883 A 5.010.7;1.1 5.6 i 0.8 ; 1.2 Jun,1994 H-3 WATER-1882,1883 A -32.6 i 76.9;77.0 -55.8 1 76.9;77.3 Jun,1994 Be-7 GRASS-1900,1901 A 0.5 0.1 ; 0.1 0.5 i 0.1 ; 0.1 Jun,1994 K-40 GRASS-1900,1901 A 4.3 i 0.2 ; 0.5 4.310.2;0.5 Jun,1994 I-131 MILK-1982,1983 A 0.010.2;0.2 0.110.1;0.1 Jun,1994 K-40 MILK-1982,1983 A 1,562.0 1 98.0;233.9 1,553.0 1 116.0;241.0 Jun,1994 Gr. Beta WATER-1972,1973 A 25.712.4;4.6 23.712.3;4.3 Jun,1994 K-40 MILK-2092,2093 A 1,430.0 1 170.0;258.3 1,430.0 140.0;239.6 Jun,1994 C-14 WATER 2116,2117 A -28.0 1 49.0;49.1 -9.0152.0;52.0 Jun,1994 Gr. Alpha WATER-2116,2117 A 0.610.5;0.5 1.110.6;0.6 Jun,1994 Gr. Beta WATER 2116,2117 A 8.410.8;1.5 7.210.7;1.3 Jun,1994 H-3 WATER-2116, 2117 A 2,544.0 1 152.0;377.9 2,522.0 i 152.0;375.2 Jun,1994 U-233/4 WATER-2116, 2117 A 1.510.2;0.3 1.5i 0.2 ; 0.2 g Jun,1994 U-235 WATER-2116, 2117 A 0.010.1;0.1 0.010.1;0.1 3 Jun,1991 U-238 WATER-2116,2117 A 0.9 i 0.2 ; 0.2 1.110.2;0.2 Jun,1994 Gr. Beta WATER-2198, 2199 A 5.310.9;1.2 5.210.8;1.2 g Jun,1994 Co-60 MILK-2156,2157 A -0.513.1;3.1 1.5 i 4.0 ; 4.0 m Jun,1994 Cs-137 MILK-2156,2157 A 1.3 i 3.6 ; 3.6 1.215.9;5.9 Jun,1994 I-131(G) MILK-2156,2157 A -0.1 0.2 ; 0.2 0.010.2;0.2 Jun,1994 I-131 MILK-2194, 2195 A 0.210.3;0.3 0.1 0.2 ; 0.2 Jun,1994 Gr. Beta WATER-2238, 2239 A 1.5 i 0.6 ; 0.7 1.710.6;0.7 Jun,1994 Gr. Beta WATER-2363, 2364 A 69.5 84.0; 84.7 5.9181.3;81.3 Jun,1994 Gr. Beta WATER-2336, 2337 A 6.211.3;1.6 6.411.3;1.6 Jun,1994 H-3 WATER-2336, 2337 A 23.6 1 80.1;80.1 -20.9 78.2; 78.3 g Jun,1994 Be-7 SLIME-2480,2481 A 0.410.2;0.2 0.410.2;0.2 g Jun,1994 Cs-137 SLIME-2480,2481 A 0.010.0;0.0 0.0 i 0.0 ; 0.0 Jun,1994 K-40 SLIME-2480,2481 A 1.3 0.2 ; 0.2 1.310.2;0.2 Jun,1994 1-131 MILK-2334,2335 A 0.110.2;0.2 0.010.2;0.2 jun,1994 Gr. Beta WATER-2733,2734 A 2.010.5;0.5 1.6 0.4 ; 0.5 Jun,1994 Sr-89 WATER-3056, 3057 A -0.611.1;1.1 -0.110.8;0.8 ~ I 186

Table A-4. In-house " duplicate" program. Concentration in pCi/L' Dste Lab Accepted' First Second ( Collrcted Analysis Code.? Rejected Result Result Jun,1994 Sr-90 WATER-3056, 3057 A 0.510.4;0.4 0.310.3;0.3 p Jun,1994 K-40 MILK-2405,2406 A 1,730.0 190.0;302.4 1,710.0 1 120.0;261.7 L Jun,1994 H-3 WATER-2432, 2433 A 26.9 1 81.9;82.0 123.2 1 85.9;87.5 Jun,1994 H-3 WATER-3000,3001 A 213.6 i 86.2;91.0 192.4 i 85.3;89.2 { Jun,1994 Gr. Alpha WATER-2459,2460 A 0.110.2;0.2 0.010.2;0.2 Jun,1994 Gr. Beta WATER-2459, 2460 A 2.3 i 0.2 ; 0.4 2.0i 0.2 ; 0.4 Jun,1994 H3 WATER-2712,2713 A 260.0 1 90.0;96.7 170.0 i 80.0;83.3 ( Jun,1994 H-3 WATER-2501, 2502 A 70.0 1 80.0;80.6 137.0 1 80.0;82.1 Jun,1994 Gr. Deta WATER-2662, 2663 A 5.0 i 0.9 ; 1.2 5.5 i 0.9 ; 1.2 Jun,1994 Gr. Beta WATER-2691,2692 A 2.410.5;0.6 2.110.5;0.6 Jun,1994 H-3 WATER-2691, 2692 A 192.6 87.0;90.9 108.3 1 83.6;84.8 Jul,1994 Co-60 MILK-2522,2523 A 5.7 i 4.5 ; 4.5 -3.215.3;5.3 Jul,1994 Cs-137 MILK-2522,2523 A 0.213.3;3.3 2.013.3;3.3 Jul,1994 I-131(G) MILK-2522,2523 A 0.110.2;0.2 0.110.2:0.2 ]ul,1994 Gr. Deta WATER-2543,2544 A 1.110.3;0.4 1.110.4;0.5 Jul,1994 K-40 WATER-2543, 2544 A 1.210.1;0.2 1.210.1;0.2 Jul,1994 Gr. Alpha WATER-2631,2632 A 0.310.9;0.9 0.811.0;1.0 Jul,1994 Gr. Beta WATER-2631, 2632 A 8.111.0;1.6 7.1 1.0 ; 1.5 Jul,1994 I-131 MILK-2863,2864 A 0.110.2;0.2 0.010.2;0.2 Jul,1994 K-40 MILK-2863,2864 A 1,360.0 i 130.0;226.1 1,450.0 1 100.0;221.1 p jul,1994 Be-7 GRASS-2754,2755 A 2.210.2;0.3 2.210.1;0.2 L Jul,1994 K-40 GRASS-2754, 2755 A 7.3 i 0.4 ; 0.8 6.910.2;0.7 Ju1,1994 Co-60 WATER-2775,2776 A -0.513.1;3.1 0.313.3;3.3 { Jul,1994 Jul,1994 Cs-134 WATER-2775,2776 A -0.8 i 3.4 ; 3.4 -1.013.2;3.2 Cs-137 WATER-2775, 2776 A 1.913.0;3.0 0.7i 2.9 ; 2.9 l Jul,1994 Gr. Beta WATER-2775,2776 A 3.010.5;0.7 2.910.5;0.7 { Jul,1994 I-131 WATER-2775,2776 A 0.0 0.2 ; 0.2 0.110.2;0.2 Jul,1994 1-131 MILK-2889,2890 A 0.110.2;0.2 0.210.2;0.2 Jul,1994 Gr. Beta WATER-2842, 2843 A 4.0 i 1.1 ; 1.3 5.2 i 1.2 ; 1.4 Jul,1994 H-3 WATER-2842,2843 A 65.8 i 83.7;84.1 32.3 1 82.2;82.3 Jul,1994 Gr. Beta WATER-2910, 2911 A 1.610.4;0.5 1.5 i 0.5 ; 0.5 Jul,1994 H-3 WATER-2910, 2911 A 74.9 i 82.6;83.2 146.8 i 85.6;87.9 l Jul,1994 Gr. Deta WATER-2930,2931 A 1.710.6;0.6 2.2 i 0.6 ; 0.7 I jul,1994 I-131 MILK-2958, 2959 A -0.110.2;0.2 -0.1 0.2;0.2 Jul,1994 K-40 MILK-2958,2959 A 1,445.0 1 122.0;231.3 1,445.0 i 134.0;237.9 Jul,1994 Sr-89 MILK-3010,3011 A -0.5 i 1.0 ; 1.0 -0.410.7;0.7 i ( 187 ~ i

F } O O Table A-4. In-house " duplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second g Collected Analysis Codes" Rejected Result Result g Jul,1994 Sr-90 MILK-3010,3011 A 1.610.6;0.6 1.3 i 0.4 ; 0.4 Jul,1994 I131 WATER-3031, 3032 A 0.210.2;0.2 0.210.3;0.3 Jul,1994 I-131 MILK-3083,3084 A 0.210.2;0.2 0.110.2;0.2 Jul,1994 K-40 MILK-3083,3084 A 1,420.0 i 170.0;257.3 1,380.0 1 150.0;240.3 Jul,1994 H-3 WATER-3106, 3107 A 79.1 1 80.4;81.1 98.4 i 81.3;82.4 Jul,1994 Gr. Beta WATER-3154,3155 A 1.7i 0.8 ; 0.8 2.2 i 0.8 ; 0.9 Jul,1994 C-14 URINE-3748,3749 A 76.0 i 83.0;83.3 74.0 1 96.0;96.3 Jul,1994 Gr. Alpha URINE-3748,3749 A 0.312.3;2.3 2.112.5;2.5 Jul,1994 Gr. Beta URINE-3748, 3749 A 3.9 i 2.5 ; 2.5 3.312.7;2.7 Jul,1994 H-3 URINE-3748,3749 A 175.0f 583.0;583.3 198.0 1 584.0;584.3 g Jul,1994 H-3 WATER-3209,3210 A -25.3 1 82.3;82.4 0.9 i 83.4;83.4 E Jul,1994 H-3 WATER-3234, 3235 A 7.7 i 82.8;82.8 -38.3 i 80.8;81.0 Jul,1994 Gr. Beta WATER-3261,3262 A 4.410.8;1.1 4.810.9;1.1 Jul,1994 G r. Beta WATER-3310,3311 A 2.6 i 1.3 ; 1.4 1.4 i 1.2 ; 1.2 Jul,1994 K-40 VEGETATION-340 A 3.4 i 0.4 ; 0.5 3.5 i 0.4 ; 0.6 Jul,1994 H-3 WATER 3469,3470 A 563.1 i 99.6;125.6 510.6 i 97.7;119.9 Jul,1994 Co-60 WATER-3811,3812 A 5.614.2;4.3 0.l i 2.3 ; 2.3 Jul,1994 Cs-137 WATER-3811,3812 A 2.914.0;4.0 -0.4 i 2.3 ; 2.3 E Jul,1994 H-3 WATER-3358,3359 A 180.0 1 100.0;103.0 200.0 i 100.0;103.6 g Aug,1994 Gr. Beta WATER-3559,3560 A 2.110.8;0.8 1.410.7;0.8 Aug,1994 Be-7 GRASS-3586,3587 A 3.510.5;0.6 3.7 i 0.5 ; 0.6 g Aug,1994 Gr. Deta GRASS.3586, 3587 A 7.410.3;0.8 7.110.2;0.7 E Aug,1994 K-40 GRASS-3586, 3587 A 7.410.8;1.1 7.110.8;1.1 Aug,1994 Sr-89 GRASS-3586, 3587 A, 0.010.0;0.0 0.010.0;0.0 Aug,1994 Sr-90 GRASS-3586,3587 A 0.0 f 0.0; 0.0 0.010.0;0.0 Aug,1994 Gr. Beta WATER-3611,3612 A 1.910.6;0.6 2.0 i 0.5 ; 0.6 Aug,1994 I-131 MILK-3942,3943 A -0.1 i 0.2 ; 0.2 0.2 i 0.3 ; 0.3 Aug,1994 K-40 MILK-3942,3943 A 1,544.0 1 128.0;245.9 1,416.0 191.0;271.2 Aug,1994 H-3 WATER-3638,3639 A 147.4 i 86.3;88.6 38.6 i 81.7;81.9 g Aug,1994 H3 WATER-3683, 3684 A 7.1 i 81.0;81.0 38.9 1 82.3;82.5 g Aug,1994 Gr. Beta WATER-3727,3728 A 4.510.8;1.0 4.810.8;1.1 Aug,1994 K-40 MILK-3842,3843 A 1,419.0 1 120.0;227.3 1,411.0 142.0;238.7 g Aug,1994 Gr. Beta WATER-3869, 3870 A 4.210.7;0.9 3.2 0.6 ; 0.8 = Aug,1994 H-3 WATER-3869,3870 A 43.8 1 81.8;82.1 33.3 1 81.4;81.5 Aug,1994 Gr. Beta VEGETATION-389 A 2.510.1;0.3 2.510.1;0.3 Aug,1994 K-40 VEGETATION-389 A 1.9 i 0.3 ; 0.3 2.3 0.3 ; 0.4 I 188 =

I Table A-4. In-house duplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes" Rejected Result Result Aug,1994 Gr. Deta WATER-3964, 3965 A 3.910.7;0.9 4.9 0.8 ; 1.1 Aug,1994 Gr. Beta WATER-3913, 3914 A 4.310.8;1.1 3.8 0.7; 0.9 Aug,1994 Tc-99 WATER-3991,3992 A 84.9 i 9.3;12.6 96.4 i 9.9;13.8 l. Aug,1994 Co-60 MILK-4016,4017 A 1.013.6;3.6 -0.910.4;0.4 Aug,1994 Cs-137 MILK-4016,4017 A -0.3 i 2.7 ; 2.7 2.313.9;3.9 I Aug,1994 I131 MILK-4016,4017 A 0.2 i 0.2 ; 0.2 0.010.2;0.2 Aug,1994 Sr-89 MILK-4040,4041 A 0.911.1;1.1 -0.110.8;0.8 Aug,1994 Sr-90 MILK-4040, 4041 A 0.91 0.5;0.5 1.110.4;0.4 I Aug,1994 K-40 MILK-4459,4460 A 1,528.0 1 170.0;268.5 1,481.0 1 151.0;251.7 Aug,1994 Gr. Beta WATER-4061, 4062 A 4.6 i 0.8 ; 1.1 4.6 i 0.8 ; 1.1 Aug,1994 Gr. Deta WATER-4113,4114 A '. 610.6;0.7 1.8 0.6 ; 0.7 Aug,1994 K-40 MILK-4168,4169 A 1,300.0 1 1.40.0;225.5 1,390.0 i 140.0;235.2 Aug,1994 Gr. Beta WATER-4284, 4285 A 5.410.9;1.2 5.2 0.9 ; 1.2 Aug,1994 II-3 WATER-4504,4505 A 378.0 99.0;111.6 428.0 1 100.0;115.7 I Aug,1994 Gr. Beta WATER-4259, 4260 A 2.910.5;0.7 2.510.5;0.6 Aug,1994 Gr. Beta WATER-4308,4309 A 2.110.5;0.6 2.110.5;0.6 Aug,1994 H-3 WATER-4308, 4309 A 172.7 i 89.0;92.0 148.1 1 88.0;90.2 Aug,1994 Gr. Beta WATER-4333,4334 A 5.l i 2.1 ; 2.3 4.112.0;2.1 Aug,1994 H-3 WATER-4333, 4334 A 161.3 1 87.4;90.1 98.0 1 84.9;85.9 Aug,1994 K-40 VEGETATION-440 A 2.710.1;0.3 3.011.0;1.0 Aug,1994 K-40 MILK-4459,4460 A 1,528.0 170.0;268.5 1,481.0 1 151.0;251.7 Aug,1994 Gr. Beta WATER-4475, 4476 A 2.810.3;0.5 2.910.3;0.5 Aug,1994 H-3 WATER-4475, 4476 A 51.1 1 80.3;80.6 56.3 1 80.5;80.9 Sep,1994 Co-60 Ml' X-4423, 4424 A -1.015.0;5.0 -0.9 i 4.1 ; 4.1 Sep,1994 Cs-137 MILK-4423,4424 A 0.714.1;4.1 -0.6 i 2.8 ; 2.8 Sep,1994 1-131 MILK-4423,4424 A 0.210.2;0.2 0.2 0.2 ; 0.2 Sep,1994 H-3 WATER-4446, 4447 A 186.2 i 89.0;92.5 223.4 1 90.4;95.4 I Sep,1994 Co-60 MILK-4525,4526 A 2.813.5;3.5 1.2 i 2.9 ; 2.9 Sep,1994 Cs-137 MILK-4525,4526 A 0.413.2;3.2 1.312.4;2.4 Sep,1994 1-131 MILK-4525,4526 A 0.210.3;0.3 -0.110.3;0.3 Sep,1994 Gr. Beta WATER-4571, 4572 A 0.110.2;0.2 0.110.2;0.2 Sep,1994 K-40 WATER-4571,4572 A 7.211.0;1.2 7.211.0;1.2 Sep,1994 H-3 WATER-3636, 3637 A 445.2 i 99.0;116.1 529.7 102.0;124.9 Sep,1994 1-131 MILK-4550,4551 A 0.010.2;0.2 0.3 i 0.3 ; 0.3 Sep,1994 K-40 MILK-4550, 4551 A 1,410.9 i 109.0;220.7 1,398.1 1 155.0;245.3 Sep,1994 Ra-226 SLUDGE-4613, A 1.410.0;0.1 1.4 i 0.1 ; 0.1 189

I.l O I Table A-4. In-house " duplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes

  • Rejected Result Result Sep,1994 H-3 WATER-4810, 4811 A

36,966.3 557.2;5,058.2 37,783.0 563.1;5,169.2 Sep,1994 H-3 WATER-4688, 4689 A 62.8 1 82.1;82.6 -9.4 i 79.0; 79.0 Sep,1994 I-131 MILK-4886, 4887 A 0.010.3;0.3 -0.1 i 0.2 ; 0.2 Sep,1994 K-40 MILK-4886, 4887 A 1,397.9 1 152.0;243.4 1,319.0 1 171.0;247.8 Sep,1994 Gr. Alpha WATER-4744,4745 A 7.112.3;2.5 7.612.2;2.4 Sep,1994 Gr. Beta WATER-4744, 4745 A 16.411.7;3.0 16.011.7;3.0 Sep,1994 K-40 SEDIMENTS-6570, A 7.810.6;1.0 7.7 i 0.6 ; 0.9 Sep,1994 K-40 MILK-4934, 4935 A 1,519.5 1 170.0;267.6 1,421.3 1 190.0;271.0 Sep,1994 Gr. Beta SEDIMENT-5000, A 8.612.0;2.2 8.612.0;2.2 Sep,1994 1-131 MILK-5022,5023 A 0.210.2;0.2 0.3 0.3 ; 0.3 Sep,1994 Sr-89 VECETATION-525 A 0.010.0;0.0 0.0 i 0.0 ; 0.0 Sep,1994 Sr-90 VEGETATION-525 A 0.010.0;0.0 0.010.0;0.0 Sep,1994 Co-60 WATER-5952,5953 A 1.7i 2.5 ; 2.5 1.2 i 2.4 ; 2.4 g Sep,1994 Cs-137 WATER-5952, 5953 A 1.812.4;2.4 0.3 i 2.2 ; 2.2 g Sep,1994 Sr-89 AIR FILTER-5348, A 420.1 11.4;43.5 439.4 i 22.0;49.1 Sep,1994 Sr-89 FILTER-5348,5349 A 420.1 i 11.4;43.5 439.4 22.0;49.1 g Sep,1994 Sr-90 AIR FILTER-5348, A 5.6 i l.2 ; 1.3 7.112.0;2.1 W Sep,1994 Gr. Alpha FILTER-5728,5729 A -0.8 i 2.6 ; 2.6 1.9 2.6 ; 2.6 Sep,1994 Gr. Alpha FILTER-5728,5729 A -0.8 i 2.6 ; 2.6 1.912.6;2.6 Sep,1994 Sr-89 FILTER-5728, 5729 A 2.0 i 6.3 ; 6.3 -3.0 i 3.6 ; 3.6 Sep,1994 Sr-90 FILTER-5728,5729 A 0.9 i 1.9 ; 1.9 1.711.3;1.3 Sep,1994 H-3 WATER-5373, 5374 A 565.0 1 96.0;123.0 561.0 1 96.0;122.6 Oct,1994 I-131 MILK-5274,5275 A 0.2 0.2 ; 0.2 0.210.3;0.3 Oct,1994 Be-7 SOIL-5394, 5395 A 0.7 0.4 ; 0.4 0.910.5;0.5 g Oct,1994 Cs-137 SOIL-5394, 5395 A 0.2 0.1 ; 0.1 0.2 0.1 ; 0.1 E Oct 1W4 Cs-137 SOIL-5394, 5395 A 0.210.1;0.1 0.2 0.1 ; 0.1 Oct,1994 Gr. Alpha SOlL-5394, 5395 A 8.9 i 2.5 ; 2.7 9.7 2.7 ; 2.9 Oct,1994 Gr. Beta SOIL-5394, 5395 A 27.212.4;3.6 27.8 2.2 ; 3.6 Oct,1994 K-40 . SOIL-5394, 5395 A 22.9 i 1.2;2.6 22.411.4;2.6 Oct,1994 Sr-89 SOIL-5394, 5395 A 0.010.0;0.0 0.010.0;0.0 Oct,1994 Sr-90 SOIL-5394, 5395 A 0.1 0.0 ; 0.0 0.1 0.0 ; 0.0 Oct,1994 Gr. Deta WATER-5421,5422 A 2610.5;0.7 3.510.5;0.7 g Oct,1994 K-40 WATER-542?. 5422 A 0.910.1;0.1 1.010.1;0.1 g Oct,1994 Co-60 MILK-5527,5528 A -1.1 i 3.3 ; 3.3 0.913.9;3.9 Oct,1994 Cs-137 MILK-5527,5528 A 3.2 i 2.4 ; 2.5 -0.513.5;3.5 Oct,1994 I-131 MILK-5527, 5528 A 0.010.2;0.2 0.010.2;0.2 ~ 190

I Table A-4. In-house " duplicate" prograrn. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes

  • Rejected Result Result Oct,1994 K-40 VEGETATION-557 A

3.0 i 0.3 ; 0.4 2.810.4;0.5 Oct,1994 Co-60 MILK-5552,5553 A 2.0 3.3 ; 3.3 1.314.1;4.1 Oct,1994 Cs-134 MILK-5552,5553 A -0.8 i 2.8 ; 2.8 0.2 i 3.0 ; 3.0 Oct,1994 Cs-137 MILK-5552,5553 A 1.012.6;2.6 -0.513.6;3.6 Oct,1994 I-131 MILK-5552,5553 A 0.1 ,0.2 ; 0.2 -0.1 i 0.2 ; 0.2 I Oct,1994 I131 MILK-5552,5555 A 0.1 i 0.2 ; 0.2 -0.110.2;0.2 Oct,1994 K-40 MILK-5552,5553 A 1,468.1 1 122.0;234.0 1,322.0 1 146.0;231.6 Oct,1994 Sr-89 MILK-5552,5553 A 0.711.1;1.1 -0.1 i 0.9 ; 0.9 I Oct,1994 Sr-90 MILK-5552,5553 A 1.7i 0.4 ; 0.5 1.410.4;0.4 Oct,1994 I-131 WATER-5595,5596 A 0.l i 0.2 ; 0.2 0.110.3;0.3 Oct,1994 Co-60 FISH-5637, 5638 A -0.1 i 1.3 ; 1.3 -0.811.9;1.9 Oct,1994 Cs-137 FISH-5637, 5638 A 0.3 i 1.3 ; 1.3 2.011.7;1.7 Oct,1994 Cs-137 SEDIMENT-5850, A 0.2 i 0.0 ; 0.0 0.210.0;0.1 Oct,1994 K-40 SED! MENT-5850, A 13.510.9;1.6 12.2 i 0.9;1.5 Oct,1994 Gr. Beta WATER-5658,5659 A 7.4 i l.1 ; 1.6 8.011.0;1.6 Oct,1994 Co-60 WATER-5682, 5683 A 0.2 i 3.4 ; 3.4 2.013.5;3.6 Oct,1994 Cs-137 WATER-5682,5683 A 0.2 i 3.1 ; 3.1 0.713.7;3.7 Oct,1994 H-3 WATER-5682,5683 A 78.6 i 76.4; 77.2 -41.8 1 71.1; 71.4 Oct,1994 H-3 WATER-5707,5708 A 12,727.1 i 1,756.4;2,465.9 12,799.1 1 1,766.1;2,479.8 Oct,1994 Co-60 SEDIMENTS-5829, A 0.4 1.5 ; 1.5 -0.6 1.7 ; 1.7 Oct,1994 Cs-137 SEDIMENTS-5829, A 0.210.0;0.0 0.210.0;0.1 Oct,1994 Be-7 GRASS-5879,5880 A 2.410.1;0.3 2.4 1 0.1; 0.3 Oct,1994 K-40 GRASS-5879, 5880 A 6.510.2;0.7 6.610.2;0.7 Oct,1994 K-40 VEGETATION-590 A 3.4 0.4 ; 0.5 3.1 1 0.3; 0.4 I Oct,1994 Sr-89 VEGETATION-590 A 0.010.0;0.0 0.0 0.0 ; 0.0 Oct 1994 Sr-90 VEGETATION-590 A 0.010.0;0.0 00 0.0 ; 0.0 Oct,1994 H-3 WATER-5928,5929 A 402.9 i 94.7;109.4 446.3 1 96.2;113.8 I Oct,1994 Gr. Beta WATER-6018,6019 A 2.4 0.7 ; 0.8 1.6 0.4 ; 0.5 Oct,1994 Co-60 SEDIMENTS-6301, A 1.1 i 0.1 ; 0.1 1.1 0.1 ; 0.1 Oct,1994 Cs-137 SEDIMENTS-6301, A 1.610.1;0.2 1.6 i 0.1 ; 0.2 Oct,1994 Gr. Beta SEDIMEN'13-6301, A 11.811.7;2.1 8.311.8;2.0 Oct,1994 Mn-54 SEDIMENTS-6301, A 0.710.1;0.1 0.8 i 0.1 ; 0.1 Oct,1994 1-131 WATER-6070, 6071 A 0.110.2;0.2 -0.2 i 0.2 ; 0.2 Oct,1994 H-3 WATER-6116, 6117 A -7.5 i 76.8;76.9 -21.5 i 76.2;76.3 Oct,1994 Gr. Beta SEDIMENT-6256, A 5.511.7;1.8 7.411.4;1.6 Oct,1994 K-40 SEDIMENT-6256, A 9.310.3;1.0 9.310.3;1.0 191

O; Ol Table A-4. In. house " duplicate" program. l Concentration in pCi/L' Date Lab Accepted' First 6 Second ) Collected Analysis Codes Rejected Result Result Oct,1994 Ra-226 SEDIMENT-6256, A 0.110.0;0.0 0.li 0.0;0.0 Oct,1o94 Ra-228 SEDIMENT-6256, A 0.110.0;0.0 0.010.0;0.0 Oct,1994 1-131 MILK-6091,6092 A 0.210.2;0.2 0.0 i 0.2 ; 0.2 gg Oct,1994 H-3 WATER-6139,6140 A 23,478.0 i 782.0;3,287.4 23,509.0 i 782.0; 3,291.5 Oct,1994 Co-60 FISH-6162, 6163 A 0.010.0;0.0 0.0i 0.0 ; 0.0 Oct,1994 Co-60 FISH-6162, 6163 A 0.1 i 0.0 ; 0.0 0.110.0;0.0 Oct,1994 Co-60 WATER-6635, 6636 A 1.812.4;2.4 -0211.7;1.7 Oct,1994 Cs-137 WATER-6635,6636 A 1.113.4;3.4 0.7 i 2.3 ; 2.3 Oct,1994 De-7 GRASS-6235, 6236 A 1.910.1;0.2 1.9 0.1 ; 0.2 Oct,1994 K-40 GRASS-6235, 6236 A 7.010.3;0.8 6.810.2;0.7 Oct,1994 Gr. Deta WATER-6277, 6278 A 2.4 i 0.6 ; 0.7 2.410.6;0.7 Oct,1994 H-3 WATER-6277,6278 A -4.1179.6;79.6 66.3 i 89.9; 90.3 Oct,1994 Gr. Beta WATER-6489, 6490 A 2.0 i 0 ',; 0.6 2.0 + 0.5 ; 0.6 g Oct,1994 H3 WATER-6489, 6490 A 742.2 1 106.5;146.7 763.2 i 107.2;149.2 g Oct,1994 H3 WATER-6214, 6215 A 4,466.0 1 189.0;636.1 4,595.0 1 191.0;653.5 Oct,1994 H-3 WATER-6327, 6328 A 131.6 i 82.8;84.7 147.3 i 83.5;85.9 Oct,1994 AC-228 SOIL-6447, 6448 A 0.7i 0.1 ; 0.1 0.710.0;0.1 Oct,1994 Dl-212 SOIL-6447, 6448 A 0.710.2;0.2 0.7 i 0.1 ; 0.1 Oct,1994 BI-214 SOIL-6447, 6448 A 0.510.0;0.1 0.5 i 0.0 ; 0.1 Oct,1994 Gr. Alpha SOIL-6447, 6448 A 6.5 2.7;2.7 6.512.5;2.6 Oct,1994 Gr. Beta SOIL-6447, 6448 A 21.512.4;3.2 20.6 t 2.4 ; 3.2 Oct,1994 K-40 SOIL-6447, 6448 A 18.110.4;1.8 18.7::0.3;1.9 Oct,1994 PB-212 SOIL-6447, 6448 A 0.710.0;0.1 0.710.0;0.1 Oct,1994 PB-214 SOIL-6447,6448 A 0.6 0.0 ; 0.1 0.610.0;0.1 g Oct,1994 RA-226 SOIL-6447, 6448 A 1.2 i 0.2 ; 0.2 1.010.2;0.2 E Oct,1994 TL-208 SOIL-6447, 6448 A 0.2 i 0.0 ; 0.0 0.2 i 0.0 ; 0.0 Oct,1994 Co-60 FISH-6372, 6373 A 0.010.0;0.0 0.010.0;0.0 Oct,1994 Cs-137 FISH-6372, 6373 A 0.010.0;0.0 0.010.0;0.0 Oct,1994 Gr. Beta WATER-6468, 6469 A 1.810.5;0.5 1.810.5;0.6 Oct,1994 H3 WATER-6468, 6469 A 137.6 1 84.6;86.6 90.4 i 82.6;83.5 Nov,1994 Gr. Beta WATER-6401,6402 A 1.8 i 0.5 ; 0.5 1.7 i 0.6 ; 0.7 Nov,1994 Gr. Deta SEDIMENTS-6422, A 6.110.6;0.9 6.410.6;0.9 Nov,1994 K-40 SEDIMENTS-6422, A 8.210.5;1.0 7.2 0.6;0.9 EE Nov,1994 Sr-89 SEDIMENTS-6422, A 0.010.0;0.0 0.010.0;0.0 Nov,1994 Sr-90 SEDIMENTS-6422, A 0.0 i 0.0 ; 0.0 0.010.0;0.0 Nov,1994 H-3 WATER-6534, 6535 A 67.9 i 82.6;83.1 36.3 1 81.2;81.4 I 192 g<

~ , Table A-4. In-house " duplicate" program. Concentration in pCi/L' Date Lab Accepted' First Second Collected Analysis Codes 6 Rejected Result Result Nov,1994 Gr. Beta WATER-6614,6615 A 5.012.0;2.1 3.9 i l.8 ; 1.9 Nov,1994 H-3 WATER-6614, 6615 A 30.7 i 81.5;81.6 -4.1 i 80.0;80.0 Nov,1994 H-3 WATER-6746,6747 A 2,734.0 1 176.0;411.4 2,851.0 1 178.0;426.6 I Nov,1994 H-3 WATER-6767,6768 A 107.0 1 83.0;84.3 95.0 1 82.0;83.0 Nov,1994 Co-60 WATER-6788, 6789 A -1.9 i 2.2 ; 2.2 -0.213.2;3.2 ,I Nov,1994 Cs-137 WATER-6788,6789 A 1.6 i 3.7 ; 3.7 -1.8 i 3.0 ; 3.1 Nov,1994 Gr. Beta WATER-6788,6789 A 5.211.3;1.5 3.010.9;1.0 Nov,1994 Gr. Beta WATER-6985,6986 A 2.0 0.5 ; 0.6 2.010.5;0.6 Nov,1994 Gr. Beta WATER-7059, 7060 A 8.6 i 1.3 ; 1.9 7.711.7;2.1 Nov,1994 H-3 WATER-7059, 7060 A 0.0 1 100.1;100.1 0.0 i 100.1;100.1 l Nov,1994 Co-60 WATER-7615, 7616 A 1.312.7;2.7 1.413.1;3.1 Nov,1994 Cs-137 WATER-7615, 7616 A -1.613.8;3.8 1.1 i 3.0 ; 3.0 l Nov,1994 I-131 MILK-7144,7145 A 0.210.3;0.3 0.310.3;0.3 Nov,1994 K-40 MILK-7144,7145 A 1,226.8 i 161.0;231.9 1,298.2 1 152.0;233.0 Nov,1994 Sr-89 MILK-7144,7145 A 0.510.7;0.7 -0.510.8;0.8 Nov,1994 Sr-90 MILK-7144, 7145 A 0.8 i 0.4 ; 0.4 1.110.5;0.5 ,I Nov,1994 Cs-137 SOIL-7193, 7194 A 0.1 i 0.0 ; 0.0 0.110.0;0.0 Nov,1994 Gr. Alpha SOIL-7193, 7194 A 11.714.0;4.2 8.213.4;3.5 l Nov,1994 Gr. Beta SOIL-7193, 7194 A 22.012.8;3.6 18.0 2.6 ; 3.2 Nov,1994 K-40 SOIL-7193, 7194 A 15.910.8;1.8 17.1 i 0.8;1.9 Nov,1994 Co-60 WATER-7594, 7595 A 2.413.0;3.0 -2.713.2;3.2 Nov,1994 Cs-137 WATER-7594, 7595 A 1.512.6;2.6 1.6 i 2.9 ; 2.9 I Nov,1994 Be-7 GRASS-7246, 7247 A 5.3 0.2 ; 0.6 5.3 0.2 ; 0.6 } Nov,1994 K-40 GRASS-7246, 7247 A 5.8 i 0.3 ; 0.6 6.010.4;0.7 .I Nov,1994 Gr. Beta WATER-7367,7368 A 6.010.6;1.1 4.910.5;0.9 Nov.1994 H3 WATER-7367, 7368 A -67.8 i 80.9;81.5 -98.7 1 79.5;80.7 Dec,1994 Gr. Beta WATER-7288, 7289 A 2.210.7;0.8 2.6 i 0.7 ; 0.8 Dec,1994 Co-60 WATER-7330, 7331 A -0.312.8;2.8 -1.0 2.7 ; 2.7 Dee,1994 Cs-137 WATER 7330,7331 A 1.412.8;2.8 1.2 2.4 ; 2.4 Doc,1994 Gr. Beta WATER-7330, 7331 A 2.510.8;0.8 2.410.8;0.9 Dec,1994 T-131(G) MILK-7391, 7392 A 1.6 2.8 ; 2.8 -3.014.6;4.6 Dec,1994 H-3 WATER-7536, 7537 A 142.3 1 83.5;85.7 61.0 1 79.8;80.3 Dec,1994 Gr. Beta WATER-7639,7640 A 5.5 0.8 ; 1.2 4.810.8;1.1 Dec,1994 H-3 WATER-7639, 7640 A 60.9 i 82.6;83.1 23.6 i 81.0;81.0 Dec,1994 H-3 WATER-7691, 7692 A 117.1 i 84.5;86.0 89.9 83.3;84.2 (" Dec,1994 Co-60 WATER-7838, 7839 A 3.812.8;2.9 -0.3 i 2.2 ; 2.2 W*n l 193 1

E O Table A-4 In-house "d uplicate" program. Concentration in pCi/L' Date Lab Accepted' First 6 Second Collected Analysis Codes Rejected Result Result Dec,1994 Cs-137 WATER-7838, 7839 A 1.212.9;2.9 -0.2 i 2.7; 2.7 Dec,1994 Gr. Beta WATER-7838, 7839 A 2.710.8;0.9 3.9 i 1.0; 1.1 Dec,1994 Gr. Beta WATER-7940, 7941 A 2.010.4;0.5 2.410.5;0.6 gg Dec,1994 H3 WATER 7940,7941 A 212.5 1 85.8;90.5 208.8 i 87.6;92.1 Dec,1994 K-40 MILK-7889,7890 A 1,468.1 191.0;276.3 1,373.2 1 160.0;245.9 Dec,1994 Cr. Beta WATER-7961, 7962 A 2.011.1;1.1 2.611.1;1.1 Dec,1994 H-3 WATER-7961,7962 A 49.8 i 82.7;83.0 -10.0 1 80.0;80.0 Dec,1994 Gr. Alpha WATER-8107,8108 A 0.310.8;0.8 0.610.8;0.8 Dec,1994 Gr. Beta WATER-8107,8108 A 1.2 0.7; 0.7 1.5 0.7; 0.7 Dec,1994 Gr. Beta WATER-8086, 808'/ A 3.3 0.6 ; 0.8 2.5 i 0.6; 0.7 Dec,1994 H-3 WATER-8009,8010 A 71.4 i 82.3;82.9 11.8 i 79.6; 79.6

  • All concentrations are reported in pCi/L, except solid samples, which are reported in pCi/g wet. Results reported as ActivityiCounting Error; Total Propagated Uncertainty (TPU).

6 Lab codes are comprised of the sample media and the sample numbers. Client codes have been eliminated protect client anonymity.

  • Acceptance is based on the difference of the two results divided by the pooled standard deviation two, where, the pooled standar ~ deviation is the square root of the sum of the squares of the TPU's.

I I 194 I=}}