b/HLi e
e o.ommonwealthEdloon C
.e ca m,eiserre.,ei s.o ania ses 4.eae. menn Gege.e. Maels $1M2 foisphens seemt NJR-83-453 Telecopyt Region Ill. Attention Mr. 16. Chrissotimos Decem6er S.1943 J. Keppler. Regional Administrator Office of Inspection and Enforcement Region til U. 5. Nuclear Regulatory Comunission 739 Roosevelt Road Glen Ellyn. IL 60137 Referencet Quad-Citles Nuclear Power Station Docket Number 50-265. DPR-30. Unit Two Appendix A. Section 6.6.B.I.c The purpose of this letter Is to provide you with nottf f cation of a Reportable Occurrence as required by Technical Specification 6.6.5.1 within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of the occurrence. This notification is an addendum to LER/R0 50-83/20-OlT. which was initially reported to your office oc October 28. 1983.
At 11:30 p.m.
on December 2.1983, a review of ultrasonic test data obtained during the current Unit Two Refuel Outage revealed a circumferential linear Indication in the heat-effected zone of weld 328-59. The pipe-to-cap weld Is a 22 inch weld on the Reactor Recirculation System ring header. This inspection was being perforated to cely with the guidelines specified in i.E.Bulletin 83-02.
This occurrence was discussed by telephone wit? Mr. Morrongle'llo of your office on December 5. 1983 Further Inforsee'
- l11 be provided by Reportable Occurrence Report R0 50-83/20-01T-1 which wl subaltted within 14 days of '
the date of this occurrence.
Respectfully.
l COMMONWEALTH EDISON COMPANY l
QUAD-CITIES AR P R STATION l
'W N. J. Kallvlenakis Station Superintendent NJKtDGC/bb cc
- 5. Rybak 8312090124 83120$
DR ADOCK 05000265 g
PDR Q
/
~
50g by V L' Q26 l
l l
_ _ - _ - _ _ _ _ _. _ _. _ _ _ _ _ _ _ _ _ _