Text

_ _ _ _ _ _ _ _ _

Mr e

s Northem States Power Company 414 Nicollet Mall unnet.poks, Minnesota 55401 TelepNne (612) 330-5500 November 23, 1983 Director Office of Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, D.C. 20555 Prairie Island Nuclear Generating Flant Docket No. 50-282 License No. DPR-42 Docket No. 50-306 License No. DPR-60 Resolution of Safety Evaluation Reports for Environmental Qualification of Safety-Related Electrical Equipment The following is transmitted in preparation for the December 1, 1983 meeting with,the NRC Staff to resolve outstanding issues associated with the Safety Evaluation Report (SER)lregarding Environmental Qualification of Safety-Related Electrical Equipment for this facility. to this letter is an agenda for this meeting which includes a discussion of all deficiencies noted in the SER and schedule for qualification. contains a detailed list, by equipment type, of SER deficiencies and resolution. contains the schedule for qualification of all remaining deficiencies identified both in the SER anl in our response to 10 CFR 50.49.

As additional background infermation relating to this meeting, the following documents are referenced:

o On April 25, 1983, we received the Safety Evaluation and Technical Evaulation Report for Prairie Island Unit 1 and 2.

o On May 5, 1983, we transmitted the Ten-Day Response to the SER to provide justification for continued operation for Category IIB items, Rosemount 1153 Series A transmitters.

The technical evaluation provided concluded that the envi-ronmental qualification of Rosemount 1153 Series A trans-mitters had been established.

We requested that they be reclassified in Category IIC (equipment satisfies all requirements except qualified life or replacement schedule).

We have since completed the qualified life evaluation.

8312060387 831123 D

PDR ADOCK 05000282

[8 P

PDR l

1

i Director NRR Page 2 November 23, 1983 o On May 19, 1983, we transmitted our Response to 10 CFR 50.49 which identified' equipment important to safety and provided a schedule for either qualification or replacement of equipment not qualified to the provisions of the rule.

This response did not reflect resolution of equipment items placed by the SER in categories IB, IIA, IIB and IV.

A supplemental response was made on August 10, 1963 to address these equipment items.

'o On May 27, 1983, we transmitted the Thirty-Day Response to the SER.

This response provided justification for continued operation for deficiencies identified in the SER.

o On June 3, 1983, the NRC Staff transmitted a Safety Evalua-tion relating to the Category IIB items, Rosemeunt 1153 Series A transmitters.

This SE concluded that the items could be reclassified from Category IIB to IIC.

o On August 10, 1983, we transmitted a supplemental response to provide resolution of equipment qualification open items cited in the SER.

This response specifically addressed each item deficiency and is the basis document for the December 1 meeting.

o On November 3, 1983, we transmitted additional information to update the status reported on May 19, 1983 pertaining to the qualification testing of Allen Bradley Terminal Blocks and GE protective coatings.

Please contact us if you require any additional information.

9 k-.

David Musolf Manager-Nuclear Support rvices cc:

Regional Administrator - III, NRC NRR Project Manager, NRC Resident Inspector, NRC G.

Charnoff Attachment

November 23,1983 I

ENCLOSURE 1 l

Agenda for Northern States Power Company Meeting with NRC Staff to resolve Environmental Qualification SER Deficiencies for Prairie Island Unit 1 & 2 l

1.

Overview of Prairie Island Environmental Qualification Program 2.

Resolution of Environmental Qualification SER l

Deficiencies t

3.

Schedule for Qualification l

l 1

I 1

i l

l l

1

{

November 23, 1983 ENCLOSURE 2 PRAIRIE ISLANE UNIT 1 & 2 RESOLUTION OF ENVIRONMENTAL QUALIFICATION SER DEFICIENCIES s

e e

li

November 23, 1983 Component Type:

Valve Controllers

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution Limitorque Motorized Valve Actuators Modesl SMB-00, SMB-3, SMB-1, SMB-0, SMB-3, SMB-000 1,2,3,4, ID NV-32064,32065,32067,32069, IIA Similarity, Aging Qualification submittals have been 5,6,7,8, 32166,32206,32207,32163,32162, Degradation, based on Westinghouse WCAP reports 9,10,11, 32077,32078,32075,32076,32084, Qualific i Life and specific vendor test reports.

12,13,14, 32085,32184,32185,32186,32096, In order to address specific defi-15,74, 32097,32103,32105,32073,32074, ciencies, a project was initiated

[1,2,3,4,

[32167,32168,32170,32064,32194, to re-evaluate environmental quali-5,6,7,8, 32208,32209,32190,32191,32178, fication of Limitorque valve opera-9,10,11,12, 32179,32180,32181,32187,32188, tors.

For the motor actuators

~

13,14,15, 32081,32082,32083,32108,32109, identified we expect that justifi-74]

32114,32116,32177,32176,32172]

cation for environmental qualifica-tion can be established and will be completed by January 1, 1984.

ID MV-32199,32043,32040,3219; IIA Similarity, As indicated above, a project was 32196,32023,32024,32016,32017, Aging, Degradation initiated to re-evaluate environ-

[32210,32046,32049,32197,32198, Qualified Life mental qualification of the identi-32028,32029,32019,32020]

fied motor actuators. We anticipate that some modification will be required to justify qualification.

This will be completed by March 31, 1985.

ID HV-32070,32068,32165,32231, IIA Similarity, These motor actuators have been 32066,32164,32230,32242,32243, Aging Degradation removed from the Master Equipment 32271,32273,32274,32276,32132, Qualified Life List. Reasons for the removal from 32138,32141 132290,32292,32293, the list are: valves are locked 32295,32147,32150,32153,32156, open; valves are for cold shutdown 32171,32173,32172,32193,32233, only and not within the scope of 32169,32192,32232]

10 CFR 50.49; or system modifications have been made and they are no longer required.

i 1

November 23, 1983 Component Type:

Solenoid Valves

[] Denotes Unit 2 Item No. and ID NRC ltem No.

Description Category Deficiencies Resolution 16 [16]

ID SV-37035,37037,37039,37036, IV Documentation not Qualified 37038,37040 l37091,37093,37095 provided.

37092,37094,37096]

Target Rock Reactor llead Vent 17,18,20, ID 33440,33441,33990,33991, IA None Qualified 21,22,23, 33281,33201,33202,33255,33256,

[17,18,20 33371,33372,33373,33374,33375, 21,22,23]

33376,33377,33378,33761,33762, 33738,33282 [33515,33516,33992, 33993,33283,33260,33261,33265, 33266,33392,33763,33764,33740, 33741,33284]

Asco NP Series Solenoid Valves 19 [19]

ID 33199,33200,33204,33254, IIA Documentation Removed from Master List.

[33258,33259,33263,33264]

Asco Solenoid Valve 9

November 23, 1983 Component Typ-::

Switches (Indication) l] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 24 [24]

ID 31624,31625 [31630,31631]

IIA Steam Exposure Item is not exposed to a steam Honeywell Micro Switch environment. The item is qualified Valve Limit Switch for the environment it is exposed to.

25,29,30, ID 34072,34074,34076,34078, IIA Documentation Item is fully qualified by applicable 31,32 [25, 31231,31232,32098,31099,31084, (Item 25 Qualified Life vendor test reports and qualified 29,30,31, 31089,31325,31326,31327,32019, l25l) life has been evaluated. Conax 32]

31092,31637,31638,31741 IIC Electric Conductor Seal Assemblies

[34080,34082,34084,34086,31233, all others have been installed to seal the 31234,31116,31117,31102,31107, switch enclosure.

31347,31348,31349,31643,31129, i

31639,31640,31743] Under Item 32 [32] ID 31313,31570,31311, 31634 [31317,31575,31315,31636]

have been removed from the master list due to system modification.

i Namco EA-180 Limit Switch 26 [26]

ID 33651,33653,33655 [33657, IB Hodification Required Modification has been completed.

33659,33661]

Item is fully qualified.

Valcor Solenoid Valve 4

(Replacement)

Sample Valves 27 [27]

ID 31235,31236,31237 (31238, IA None Qualified

,)

31239,31240]

]

Name EA-170 Limit Switch j

28 [28]

ID 31621, 31622 (31627,31628]

IIA Aging, Qualified Analyses have been performed to Namco EA-170 Valve Limit Switch Life, Pressure pro-address qualified life, replacement file steam exposure.

schedule and pressure profile. The item is not exposed to a steam environment. This item is fully qualified.

November 23, 1983 Component Type:

Switches (Indication) Cont.

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Catego ry Deficiencies Resolution 67 [67]

ID 18252,18253 [18268,18269]

IIC Aging, Qualified Additional analysis have been per-Barton Flow Switch Life or Replacement formed to address deficiencies. The Component Cooling item is fully qualified, l

l l

l

November 23, 1983 Component Type:

Motors

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Catego ry Deficiencies Resolution 4

33 [33]

ID 15-9,16-01 [25-9,26-01]

IIA Qualified Life, Additional analysis based on vendor Electric Machir.ery Aging, Radiation contact have been performed to Containment Spray Pump Motor address deficiencies.

Item is fully qualified.

34 [34]

ID 116-18,126-18,116-9,126-32 IIA Similarity, Aging Environmental Qualification was re-

[216-18,226-18,216-19,226-32]

Qualified Life, evaluated based on additional quali-Joy / Reliance Criteria regarding fication reports from the vendor.

Dome Recirc Fan Radiation All deficiencies have been satis-factorily addressed.

2 35 [35]

ID 117-2,127-2,117-3,127-3 IIA Similarity, Aging, Additional qualification analysis

[217-2,227-2,217-3,227-3]

Qualified Life, have been performed based on addi-Westinghouse Electric Criteria regarding Lional vendor information. All Containment Fan Coil Unit Motors Temperature / Pressure deficiencies have been satisfactorily exposure addressed.

l 36,37 ID 15-1,16-5,15-4,16-4 [26-3, IIA Similarity A project has been initiated to re-

[36,37) 25-5,25-4,26-4]

evaluate environmental qualification.

Westinghouse Vendor has been contacted to identify i

RiiR & SI Pump Motor documentation. This will be completed by February 15, 1984. Any necessary,

modification or replacement will be completed by March 31, 1985.

i

November 23, 1983 Component Type:

Transmitters i

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 38 [38]

ID 23073,23074 [23075,23076)

IB Modification required Item will be replaced with qualified Barton Model 332 Rosemount 1153 Series B qualified SI Flow t;a smit.ters prior to March 31, 1985.

39,48,49 ID 23021,23022,23023,23024, IIA Required accuracy Instrinnent accuracy consideration are

[39,48,49] 21203,21204,21205,21200,21201, included in the Emergency Procedure 21202 [23025,23026,23027,23028, Upgrade required by NUREG 0737 1.C.1.

21209,21210,21211,21206,21207, 21208]

Foxboro E13PH (MCA), FW Flow Foxboro E11GM (MCA), Stm Gen Pres 44 [40]

ID 1PT-709,lPT-710 [23017,23018, IIB Not Qualified All deficiencies have been addressed 23019,23020) and accepted. Reference NRC letter Rosemount 1153 Series A from Robert Clark to D.M. Musolf Unit 1 Wide Range RCS Press (NSP) dated June 3, 1983. Aging Unit 2 Steam Flow qualification has been addressed by additional analysis.

40 [44]

ID 23013,23014,23015,23016 IB Modification required Transmitters have been replaced with

[2PT-709,2PT-7101 Rosemount 1153 Series D transmitters Unit 1 Steam Flow which are fully qualified.

Unit 2 Wide Range RCS Press 41 [41]

ID ILT-725,lLT-726,lLT-727A, 1 11 Modification required Transmitters have been replaced with ILT-727B [2LT-725,2LT-726, Delaval Level Transmitters (Model 2LT-727A,2LT-727B)

XM-54854-323) which are fully Magnet rol Transmitters qualified.

Containment Sump Level 1

l

November 23, 1983 Component Type:

Transmitters (Cont.)

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 43,45 ID ILT-487,lLT-488,21164,21165 IB Modification required Transmitters have been replaced with 21166, 21167 12LT-487,2LT-488, Foxboro NE Series Transmitters which 21168,21169,21170,21171]

are fully qualified.

Wide Range Stm Gen Level Accumulator Pressure 42 [42)

ID 24042,24042,24043 [24046, IB Modification required Transmitters will be replaced with l

24047,24048]

Barton Model 764/351 transmitters Barton Model 386/351 which are fully qualified. Unit 2 Pressurizer Level has been completed. Unit I will be completed during the refuleing out-age scheduled to start December 28, 1983.

'46 [46]

ID 21146,21147,21148,21150 IB Modification required Transmitters are fully qualified.

[21154,21155,21156,21157]

Foxboro EllGM (MCA-RRW)

Pressurizer Pressure I

47 147]

IPT-729 [2PT-729]

IIB Not Qualified Item removed from master equips' nt e

Rosemount 1153 Series A

list, t

M

November 23, 1983 5

Component Type:

Detectors, Sensors, Transducers, Primary Elements & Connectors

[] Denotes Unit 2 Item No. and ID i

NRC Item No.

Description Category Deficiencies Resolution

[54]

ID [15314]

IIA Documentation; Aging; References provided previously were Wide Range RCS Temp Qualified Life; re-evaluated to address qualifica-Rosemount RTD Required Profile; tion deficiencies including qualified-Spray Criteria; life and replacement schedule.

i Functional Testing Criteria; Instrument Accuracy 55 155]

ID 15331,15332,15333,15334 IIA Documentation; Aging; References provided previously were

[15315,15322,15323]

Qualified Life; re-evaluated to address qualifica-Wide Range RES Temp Required Profile; tion deficiencies including qualified t

i Sostman RTD Spray Criteria; life and replacement schedule.

Functional Testing Criteria; Instrument Accuracy 52 [52]

ID SC-35085,SC-35028 [SC-35084, IIA Qualification not Component has been removed from SC-35029]

eatablished master list.

Fisher Signal Converter t

i

)

50,51 ID IEQ-443,lEQ-444,1EQ-445, IB Equipment modification Qualification Testing of this item i

IEE-443,1EE-444, LEE-445 [2EQ-443, required.

is nearly completed. Some modifica-j 2EQ-444,2EQ-445,2EE-443,2EE-444, tion of installed equipment may be 2EQ-445]

required as a result of this test.

Endevco Accelerometer, Unholtz-This will be completed by March Dickey Amplifier 31, 1985.

Pressurizer Relief Valve Leak Detection System 53 [53]

ID 15456,15457,15458,15459 IB Equipment modification A new system utilizing qualified

[15610,15611,15612,15613]

required incore thermocouple cable exiting Incore Thermocouple System containment through qualified containment penetrations has been installed. The new equipment is included in the Master Equipment 2

List.

4

November 23, 1983 Component Type:

Electrical Cable & Splices

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 4

56 [56]

BIW Control Cable IIA Submergence References provided previously were re-evaluated to address submergence.

This evaluation is summarized in the SER response.

It was concluded that the environmental parameters are enveloped by reference documents.

57 [57]

Kerite Control Cable IIA Similarity; Aging Identified additional vendor quali-Degradation; Qualified cation documentation to address Life; Criteria deficiencies.

regarding Spray 58 [58]

Okonite Cable IIA Submergence References provided previously were re-evaluated to address submergence.

{

This evaluation is summarized in the SER response.

It was concluded that the environmental parameters are enveloped by reference documents.

59 159]

Okonit Cable Splice IIA Similarity; Aging Deficiencies were addressed through j

Degradation; Qualified additional vendor correspondence and Life, Submergence test data.

It was concluded that the l

j environmental parameters are

/

enveloped by reference documents.

71 [71]

Kerite Cable Splice IIA Similarity Deficiencies addressed by additional vendor correspondence.

i 72 [72]

Okonite Splicing Tape IIA Submergence Deficiency was addressed through T95 additional vendor correspondence and test data.

It was concluded that the environmental parameters are enveloped h7 reference documents.

i

)

t 1

November 23, 1983 Component Type:

Electrical Cable & Splices (Cont.)

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Ca tego ry Deficiencies Resolution 73 [73]

Okonite Splicing Tape IIA Submergence Deficiency was addressed througli T35 additional vendor correspondence and test data.

It was concluded that the environmental parameters are enveloped by reference documents.

i l

l November 23, 1983 Component Type:

Terminal Blocks & Protection Coatings

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 60 [60]

Allen Bradley Terminal IB Equipment modifica-Environmental qualification testing I

61 [61]

Strips and GE Epoxy tion required to has recently been completed. Our establish qualifica-letter dated November 3,1983, tion provided: test sn==ary, justifica-tion for continued plant operation, i

and schedule for qualification.

4 I

i 1

I

November 23, 1983 Component Type:

Electrical Penetrations & Seals

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution i

'68,69,70 DG O'Brien Electrial IA None Quali fied

[68,69,70] Pentrations t

[

1

~

1 t

4 l

.~.

November 23, 1983,

Component Type:

Lubricants

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 62,63 Chevron Lubricant IA None Qualified

[62,63]

Mobile Lubricant l

9

November 23, 1983 Component Type:

Fuses & Fuseholders

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description Category Deficiencies Resolution 64 [64]

Bussman Fuseholder IIA Criteria regarding References provided previously were steam exposure re-evaluated and installation enclosures were discussed.

It was concluded that environmental parameters are enveloped by ref-erence documents.

e

i November 23, 1983 Component Type:

Load Centers

[] Denotes Unit 2 Item No. and ID NRC Item No.

Description-Category Deficiencies Resolution 66 [66]

DC Distribution Panel IB Equipment modifica-Safety related loads to these panels Creiger tion required have been relocated. Distribution panels in the auxiliary building have been added to the equipment master list and qualification has been completed.

65 [65]

GE Motor Control Centers IB Equipment nodifica-Required loads will be relocated to tion required new motor control centers located in a mild environment. This will be completed prior to March 31, 1985.

November 23, 1983 ENCLOSURE 3 SCHEDULE FOR QUALIFICATION As of this date, all equipment items identified as SER defi-ciencies.and all equipment items on the Prairie Island harsh environment safety-related equipment master list are fully qualified with the exception of the items listed below:

1.

Allen Bradley 1492CD3 Terminal Blocks and GE 74010/

74010A Protective Coating.

Our letter dated November 3, 1983 provided current status pertaining to qualification testing, justification for continued plant operation, and a schedule for replacing certain instrument related terminals with qualified splices.

For Unit 1 this work will be completed during the Cycle 8/9 refueling outage scheduled to start on December 28, 1983.

Unit 2 work will be completed by December 31, 1983.

2.

Plant ID No's 113-54, 123-55, 213-53, 223-54, 113-55, 123-56, 223-54, 223-55, 113-53, 123-54, 213-52, 223-53; Gould-Centory unit cooler motors; System ZH & ZE:

Motors are subject to radiation during recirculation only.

We are confident that these motors can be qualified for radiation, however, documentation of materials used has been difficult to establish.

Replacement motors have been ordered and will be delivered by July 1984.

Motors will be replaced prior to March 31,-

1985.

3.

Plant ID No's Pnl 151, 161, 191, 162' Creiger Electric and Commonwealth Electric DC Panels:

Qualification by test / analysis has been completed.

Some modification is required for Unit 1 installed panels as a result of qualification.

This work will be completed during the cycle 8/9 refueling outage scheduled to start on December 28, 1983.

4.

Plant ID No. Pnl 19 Commonweal;o F ectric DC Panel:

We have been unable to adeqt tn 3;i

-c ament qualification for this load center.

i'his panel,,ill be removed.

Work will be completed during the Unit 1 cycle 8/9 refueling outage scheduled to start December 28, 1983.

5.

Plant ID No's 24041, 24042, 24043 Pressurizer Level Transmitters:

Qualified replacement transmitters are on site and will.

be replaced during the Unit 1 cycle 8/9 refueling outage scheduled to start December 28, 1983.

Unit 2 related work has been completed.

6.

ID No's 1EQ-443, -444, -445, [2EQ-443, -444, -445]

1EE-443, -444, -445 [2EQ-443, -444

-445]; Endevco 1

2273 AM20 Accelerometer and Unaoltz Dickey 22CA-2TR t

Charge Amp, Pressurizer Relief Valve Leak Detection System:

The qualification test is nearly complete.

Some modifica-tion of installed equipment may be required as a result of this test.

This will be completed prior to March 31, 19C5.

7.

Plant ID No's 23073, 23074 [23075, 23076]

Barton 332 Transmitters, SI Flow Transmitters:

These transm15ters are subject to radiation during recir-culation only.

Qualified transmitters are on site and will be installed prior to March 31, 1985.

i 1

8.

Plant ID ILA1, ILA2, 1M1, IMA2 _ [:2 LA1, 2LA2] General Electric 7700 Motor Control Centers:

Affected starters are for safeguards chiller-loads and mai.. steam supply valve to TD AEW pumps.

New motor control centers have been purchased for required loads and new plant installations.

Procurement lead time has been affected because several projects will utilize these load centers.

Installation will be completed during Unit 1 Cycle 9 and Unit 2 Cycle 8 and prior to March 31, 1985.

9.

Limitorgpe Motorized Valve Actuators Plant ID No's.

32199, 32043, 32040, 32195, 32196, 32023, 32024, 32016, 32017, [32210, 32046, 32049, 32197, 32198, 32028, 32029, 32019, 32020]

A project has been initiated to re-evaluate the environ-mental qualification of all safety-related Limitorque valve controllers as a result of the equipment qualifica-tion open items cited in the SER.

This qualification evaluation is expected to be completed by January 1, 1984.

Any mcdification or replacements following this evaluation will be completed prior to March 31, 1985.

i l

l

.. ~

10. Plant ID 15-1, 16-5, 15-4, 16-4 [26-3, 25-5, 25-4, 26-4)

Westinghouse SI and RHR Pump Motors:

A project has been initiated to re-evaluate the environ-mental qualification of these motors as a result of the equipment qualification open items cited in the SER.

This qualification evaluation should be completed by February 15, 1984 and is expected to result in full qualification.

11. Containment Spray pH Plant modifications to the containment spray caustic aedition system will be made to prevent spray pH from exceeding 10.5 during certain RHR and CS pump combinations as noted in our April 30, 1982 letter and in our May 14, 1983 response to 10 CFR 50.49.

These modifications and a change in the Technical Specifications related to caustic addition standpipe level and concentration were the sub-ject of a License Amendment Request dated June 10, 1983.

Required modifications have been completed on Unit 2 and will be completed for Unit 1 during the cycle 8/9 refuel-ing outage scheduled to start December 28, 1983.