Proposed Changes to Section 4.3.3 of Facility License R-76 Technical Specifications 4.3.3 Radiation Monitoring System Applicability: This specification applies to the surveillance requirements for the area monitoring equipment, Argon-41 monitoring system, and the continuous air monitoring system.
Objectives: The objectives are to ensure that the radiation monitoring equipment is operating properly, capable of performing their intended function, and that the alarm points are set correctly.
Specification: All radiation monitoring systems shall be verified to be operable at least monthly at an interval not to exceed 60 days.
In addition, the following surveillance activities shall be performed on an annual basis at intervals not to exceed 15 months. 1) The area radiation monitoring sys-tem shall be calibrated using a certified source; b) a channel check on the A-41 system shall be dcne using at least twe different calibrated gamma-ray sources; 3) a channel test shall be performed on the CAM using a calibrated source.
Basis:
Experience has shown that monthly verification of Radiation Monitor-ing Systems' operability in condt:nction with an annual more thorough surveil-lance is adequate to correct far any variations in the systems caused by a change of operating characteristics over a long time span.
l 8312060261 831128 PDR ADOCK 05000027 P
PDR l
l t
L
Proposed Changes to Section 5.4 of Facility License R-76 Technical Specifications (The sub-section on " specifications" needs to be changed to correspond to the proposed changes in Section 5.3.3. )
Specifications:
(1) Function of Area Radiation Monitor (gamma-sensitive instruments):
Monitor radiation fields in key locations, alarm and readout at control console.
(2) Function of Continuous Air Radiation Monitor (beta, gamma-sensitive detectorwithparticulatecollectioncapability): Monitor radioactive particulate activity in the pool room air, alarm and readout at control console.
(3) Function of A-41 Monitor (gamma-sensitive instrument): Monitor A-41 content in reactor exhaust air.