ML20082M697

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Cracked Card Edge Connector Receptacles in Westinghouse 7300 Process Sys.Initially Reported on 831025.Samples of Cracked Receptacles Shipped to Westinghouse.Next Rept Will Be Submitted by 840210
ML20082M697
Person / Time
Site: Wolf Creek 
Issue date: 11/23/1983
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Gagliardo J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, KMLNRC-83-153, NUDOCS 8312060237
Download: ML20082M697 (1)


Text

KANSAS GAS AND ELECTRIC COMPANY THE ELECTFMC COMPANY GLENN L MOESTER v,ca ms.oew uc'""

November 23, 1983

]

l i:

M Mr. J. E. Gagliardo, Acting Chief Reactor Projects Branch 2 U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 KMLNRC 83-153 Re:

Docket No. STN 50-482 Subj: Potential 10CFR50.55(e) Report - Cracked Card Edge Connector Receptacles in Westinghouse 7300 Process System

Dear Mr. Gagliardo:

This letter provides an interim report on a potential 10CFR50.55(e) concerning cracked card edge connector receptacles in the Westinghouse 7300 Process System at Wolf Creek Generating Station. This matter was initially reported by Messrs. Maynard and Creel of Kansas Gas and Electric Company (KG&E) to Mr. William Johnson of the Nuclear Regulatory Commission (Region IV) on October 25, 1983.

During Field Change Notice (FCN) Modifications to the Westinghouse 7300 Process System, I&C Technicians found cracked card edge connector're-ceptacles. A one hundred percent inspection of the Westinghouse 7300 Process Sfstem receptacles indicated that approximately fifteen percent of these receptacles exhibited cracking. Westinghouse has been requested to evaluate this matter.

In order to facilitate this evaluation, samples of cracked receptacles have been shipped to Westinghouse.

The status of the evaluation and resolution of this matter will be reported to you on or before February 10, 1984.

In the interim, please direct any questions concerning this subject to me or Mr. Otto Maynard of my staff.

8312060237 831123 very truly yours, PDR ADOCK 05000482

[per Glenn L. Koester Vice President - Nuclear GLK:cke cc: RCDeYoung

{

m WSchum/ASmith C'8 201 N. Mart:et -Wichita, Kansas - Mail Address: RO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 261-6451