Special Rept:On 950220,steam Jet Air Ejectors Placed Into Svc.At Same Time Augmented off-gas Treatment Sys in Svc & Charcoal Beds Bypassed Due to High Indicated Moisture in Air Stream.Moisture Indication Corrected
ML20082F486
Person / Time
Site: Cooper Entergy icon.png
Issue date: 03/31/1995
From: Herron J
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLS950086, NUDOCS 9504120143
Download: ML20082F486 (2)


Text

7;

{.

h _,,.,

M Nebraska Public Power District COOPER NUCLEAR STATION P.Q BOX M BRoWNVILLE NEBRASKA 68321 p:

'"i W 4 Wi NLS950086 March 31, 1995 U. S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, DC 20555

Subject:

Special Report per Technical Specification 3.21.C.4.c Pursuant to Technical Specification 6.5.3.B Cooper Nuclear Station, NRC Docket 50-298, DPR-46 Gentlemen:

This Special Report is being submitted to document the discharge of the Cooper Nuclear Station main condenser air ejector for more than seven days without treatment by charcoal absorbers as required by Technical Specification 3.21.C.4.c.

The Steam Jet Air Ejectors were placed into service at approximately 2:00 am.on February 20, 1995.

At this time the Augmented Off-Gas Treatment system was in service, however, the charcoal beds were bypassed due to high indicated moisture in the air stream. The moisture indication was corrected and the charcoal beds:were placed in service on February 28, 1995.

During this period, the gas from the main condenser was monitored and discharged in effluent air through the elevated release point.

The projected fraction of the quarterly Technical Specification release limits for nobel gases was 3.4E-02 for beta and 1.lE-02 for gamma radiation.

Sincerely, J

T. Herron P ant Manager

/nr cc:

L. J. Callan G. R. Horn J. H. Mueller R. G. Jones R. A. Sessoms K. C. Walden R. L. Koch INPO Records Center NRC Resident Inspector 1' 2 0 0 4 0 "CNS Training 3

S'"3 '

9504120143 950331 hI CNS Quality Assurance i

PDR ADOCK 05000298

_ S PDR-6

4 Q

LIST OF NRC COMMITMENTS l ATTACHMENT 3 l

^

Corre'spondence No: NLS950086 The following table identifies those actions committed to by the District in this document. Any other actions discussed in the submittal represent intended or planned actions by the District.

They are described to the NRC for the NRC's information and are not regulatory commitments.

Please notify the Licensing Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.

COMMITTED DATE COMMITMENT OR OUTACE None