__

c Arizona Public Service Company P.O BOX 21666 e PHOENIX. ARIZONA 85036 November 8, 1983 ANPP-28199-BSK/RQT U. S. Nuclear Regulatory Commission Region V Creekside Oaks Of fice Park 1450 Maria Lane - Suite 210 Walnut Creek, CA 94596-5368 Attention: Mr. T. W. Bishop, Director Division of Resident Reactor Projects and Engineering Programs

Subject:

Interim Report - DER 83-66 A 50.55(e) Potentially Reportable Deficiency Relating to Internal Problems In Unit 1 Motor Driven Auxiliary Feedwater Pump.

File: 83-019-026; D.4.33. 2 Reference : Telephone Conversation between P. Narbut and R. Tucker on October 11, 1983.

Dear Sir:

The NRC was notified of a potentially reportable deficiency in the ref erenced telephone conversation. At that time, it was estimated that a determination of reportability would be made within thirty (30) days.

Due to the extensive investigation and evaluation required, an Interim RQortisattached.

It is now expected that this information vill be f1Ttalizei, by January 20, 1984 at which time a complete report will be subtaittedi h

ours O, f

ID$

[

h Very truly o-e E E c% bt p i

E. E. Van Brunt, Jr.

APS Vice President, Nuclear Projects Management ANPP Project Director EEVB/RQT:ru Attachment cc: See Page Two j

l

l Mr. T. W. Bishop DER 83-66 Page Two cc:

Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washiraton, D. C. 20555 T. G. Woods, Jr.

G. C. Andognini J. A. Roedel D. B. Fasnacht A. C. Rogers B. S. Kaplan W. E. Ide J. Vorces J. R. Bynum D. D. Green P. P. Klute A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher R. M. Grant D. R. Hawkinson L. E. Vorderbrueggen G. A. Fiorelli S. R. Frost J. Self D. Canady Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, GA 30339 1

INTERIM REPORT - DER 83-66 POTENTIAL REPORTABLE DEFICIENCY ARIZONA PUBLIC SERVICE COMPANY (APS)

PVNGS UNIT - 1 I.

Potential Problem Af ter hot functional testing of the electric motor driven Auxiliary Feedwater Pump, inspection of the pump tagged (IMAFBP01) revealed the following deficiencies:

The impeller wear ring on the first stage impeller had fractured into several pieces which were found lodged in other portions of the pump.

The first stage impeller had a groove approximately 3/8" wide by 1/4" deep on the outside diameter of the hub.

Various nicks, scars and burrs were found throughout the pump internals, apparently caused by f racturing of first stage wear ring.

The shaft sleeve between the third and fourth stages is grooved longitudinally.

The Auxiliary Feedwater Pump was supplied by Bingham-Willemette under purchase order 13-MM-021.

II:

Approach To and Status of Proposed Resolution Bechtel engineering has requested the services of a Bingham-Willamette field representative to inspect the damaged pump. A copy of DER 83-66 was sent to Bingham-Willamette to provide reportability disposition and technical justification for corrective action.

III.

Projected Completion of Corrective Action and Submittal of the Final Report Evaluation of this candition and submittal of the Final Report is f orecast to be completed by January 20, 1984.

,