ML20082E575
| ML20082E575 | |
| Person / Time | |
|---|---|
| Site: | Washington State University |
| Issue date: | 11/21/1983 |
| From: | WASHINGTON STATE UNIV., PULLMAN, WA |
| To: | |
| Shared Package | |
| ML20082E573 | List: |
| References | |
| NUDOCS 8311280240 | |
| Download: ML20082E575 (3) | |
Text
?
g' Corrections to the Annual Report on the Operations of the Washington State University TRIGA Reactor Facility License R-76 for the Reporting Period of July 1, 1982 to June 30, 1983 enrrected sections to the Annual Report are as follows:
Page 2, Section F.1.,
Radioactive Liquid Release The December'sdatagivenforRadioactiveL{quidReleasewasinerror.
identified isotopes were Sm153 and Er17, not Pa233 and Erl71 as reported.
Also, the specific concentration of each major isotope identified was not given.
The specific activity for major isotopes identified are given below.
153
-7 3
Sm 7.0 x 10 pci/cm
-7 3
Er 3.0 x 10 pCi/cm 10 CFR 20, Appendix B, Table 1, Column 2 limits for these isotopes are:
Sm 2 x 104-3 153 pCi/ml Er 3 x 10~ pCi/ml Page 4, Section G, Personnel and Visitor Radiation Exposure The values given for average quarterly exposures were for reactor personnel only. Below are the average quarterly exposures, corrected to include all personnel routinely handling radioactive material at the Nuclear Radiation Center.
The average quarterly exposure of personnel working at the Nuclear Radiation Center are shown in Table V1 below. The maximum quarterly exposure for an individual was 140 millirem.
TABLE VI Average Quarterly Facility Personnel Exposure (in millirems)
J'aly-Aug-Sept Oct-P3v-Dec Jan-Feb-March April-May-June 39 42 55 22 i
8311280240 831121 PDR ADOCK 05000027 R
I Page 5,Section I, Environmental Monitoring Program At the time the Annual Report was prepared, April, May, and June quarterly data were not available.
Below is the completed Environmental Radiation Levels given in Table VII.
TABLE VII Environmental Radiation Levels in the Vicinity of the WSU Nuclear Reactor
- Exposure in pR/ day J-A-S 0-N-D J-F-M A-M-J 164 158 234 153 177
- From sampling stations located 50-500 meters of the Nuclear Radiation Center The July, August, September data and the April, May, June data were found to be transposed in Table VIII.
Below is the corrected Table VIII informa-tion. Also, the missing data for April, May and June are included.
TABLE VIII Exposure Rates Adjacent to the WSU Reactor Exposure in UR/ day J-A-S O-N-D J-F-M A-M-J Building Entrance 185 185 285 186 210 E. Lower Loading Dock 141 217 225 155 185 E. Pool Room Door 3011 1435 940 289 1419 Storage Shed 228 196 192 165 195 N. Side of Building 130 196 212 144 171 W. Beam Room Door 141 141 252 155 172 W. Side of Building 120 196 225 173 179
- From sample stations located less than 50 meters of the Nuclear Radiation Center 4
7
,.-.------n,---n,,,.,
,,---.-n.,...-n
o Page 6,Section I The environmental water sampling and counting performed by the Radiation Safety Office, which was reported as being analyzed, is not the case.
The Radiation Safety Office has discarded these samples and this data is not available.
t