' REFUELING OPERATIONS l

WATER LEVEL - REACTOR VESSEL LIMITING CONDITION FOR OPERATION 3.9.9 At least 23 feet of water shall be amintained over the top of irradiated fuel assemblies seated within the reactor pressure vessel.

APPLICABILITY: -During movement of fuel assemblies or CEAs within the reactor pressure vessel while in MODE 6, except during latching and i

l unlatching of CEAs.

I ACTION:

With the requirements of the above specification not satisfied, suspend all operations involving movement of fuel assemblies or CEAs within the l

pressure vessel. The provisions of Specification 3.0.3 are not applicable.

l l

1 SURVEILLANCE REQUIREMENTS 4.9.9 The water level shall be determined to be at least its minimum required depth within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> prior to the start of and at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter during movement of fuel assemblies or CEAs.

l l

I l

l l

i l

1 I

l l

1 l

ARKANSAS - UNIT 2 3/4 9-10 Amendment No.

I

S O

$P O

4 MARKUP OF CURRENT ANO-2 TECHNICAL SPECIFICATIONS (FORINFO ONLY) 1

ru I

n l

REFUELING OPERATIONS '

WATER LEVEL - REACTOR VESSEL l

1

=

LIMITING CONDITION FOR OPERATION 3.9.9' At least 23 feet of water shall be maintained over the top of

-l irradiated fuel assemblies seated within the reactor pressure vessel.

j APPLICABILITY:

During movement of fuel assemblies or CEAs within the reactor pressure vessel while in MODE 6, except during latching and jl unlatching of CEAm.

- ACTION:

With the requirements of the above specification not satisfied, suspend all operations involving movement of fuel assemblies or CEAs within the pressure vessel. The provisions of' Specification 3.0.3 are not applicable.

.l

?

SURVEILLANCE REGUIREMENTS f

4.9.9 The water level shall be determined to be at least its minimum l

required depth within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> prior to the start of and at least once per i

~