ML20082D111

From kanterella
Jump to navigation Jump to search
Application to Amend License NPF-12,adding Addl Requirements to Feedwater Isolation Valve Tech Specs
ML20082D111
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/16/1983
From: Dixon O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20082D113 List:
References
NUDOCS 8311220317
Download: ML20082D111 (2)


Text

.

SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OFPICE 764 COLuusiA. south CARoVNA 29218 O. W. Dixoh. JR.

.c7,',,"o',',* *,",'o,,

November 16, 1983 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Virgil C. Summer Nuclear Stati Docket No. 50/395 on Operating License No. NFF-12 Technical Specification for Feedwater Isolation Valves

Dear Mr. Denton:

Discussions have been held between South Carolina Electric and Gas Company (SCE&G), Nuclear Regulatory Commission (NRC)

Region II, and the Office of Nuclear Reactor Regulation (NRR) concerning the Feedwater Isolation Valves at the Virgil C.

Summer Nuclear Station (VCSNS).

These discussions concerned our belief that these valves are not adequately addressed in the VCSNS Technical Specifications.

Specifically, there is no Action Statement included to provide action to be taken in the event that a Feedwater Isolation Valve (s) becomes inoperable.

There is also no Surveillance Requirement, other than 4.0.5, specifically included for these valves.

SCE&G has reviewed this condition and requests that an amendment be made to the Technical Specifications as shown on the attached " marked up" pages.

SCE&G has determined that a finding of no significant hazards is justified in that additional requirements are being added to the Technical Specifications.

This change has been reviewed and approved by the Plant Safety Review Committee (PSRC) and the Nuclear Safety Review Committee (NSRC).

A check in the amount of Four Thousand Dollars ($4,000.00) is enclosed for processing this change.

If you have any questions, please contact us at your convenience.

Ver truly yours, 831122O317 831116 PDR ADOCK 05000395

\\

P l

PDR O. W. Dixon, v

jg ARK:OWD/fjc~

N h@

Attachments; cc:

See Page Two y.

i Technical SpecificaElon fo Feedwater Isolation Valves November 16, 1983 Page #2 cc:

V. C. Summer T.

C. Nichols, Jr./O. W. Dixon, Jr.

E. H. Crews, Jr.

E.

C. Roberts W. A. Williams, Jr.

D. A. Nauman J.

P. O'Reilly Group Managers O. S. Bradham N.

E.

Clark R. B. Clary C. A. Price A. R. Koon C. L. Ligon (NSRC)

G. J. Braddick D. J. Richards NRC Resident Inspector J. B. Knotts, Jr.

NPCF File (Lic./Eng.)

i e

l

)

f e

4 p.

c.,m 5,-.

..y.