OPERATING DATA REPORT DOCKET NO. 50-336 DATE 10/13/83 COMPLETED BY J. Gibson TELEPHONE (203) 447-1791 Ext. 4431 OPERATING STATUS 1.

Unit Name:

Millstone 2 Notes Items 21 and 22 2.

Reporting Period:

September 1983 cumulative are weighted 3.

Licensed Thermal Power (MWt):

2700 ave. unit operated at 2560 4.

Nameplate Rating (Gross MWe):

909 MW thermal prior to its 5.

Design Electrical Rating (Net MWe):

870 uprating to the current 6.

Maximum Dependable Capacity (Gross MWe):

895 2700 MW thermal power 7.

Maximum Dependable Capacity (Net MWe):

864 level.

8.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7)

Since Last Report, Give Reasons:

N/A 9.

Power Level To Which Restricted, If Any (Net MWe):

N/A 10.

Reasons For Restrictions, If Any:

N/A This Month Yr.-to-Date Cumulative

11. Hours In Reporting Period 720 6551 68063
12. Number Of Hours Reactor Was Critical 0

3130.5 48365.3 13.

Reactor Reserve Shutdown Hours 0

0 2205.5

14. Hours Generator On-Line 0

2994.9 46182.2

15. Unit Reserve Shutdown Hours 0

0 468.2

16. Gross Thermal Energy Generated (MWH) 0 7877464 13171669 l

17.

Gross Elec. Energy Generated (MWH) 0 2575530 37806378

18. Net Electrical Energy Generated (MWH)

(-3035) 2462401.4 36224214 19.

Unit Service Factor 0

45.7 67.9 l

20. Unit Availability Factor 0

45.7 68.5 l

21. Unit Capacity Factor (Using MDC Net) 0 43.5 63.5
22. Unit Capacity Factor (Using DER Net) 0 43.2 62.6 23.

Unit Forced Outage Rate 0

13.7 19.1 l

24.

Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

Continuation of Refuel / Maintenance Outage 25.

If Shut Down At End Of Report Period, Estimated Date of Startup:

26.

Units In Test Status (Prior to Commercial Operation):

Forecast Achieved l

INITIAL CRITICALITY N/A N/A l

INITIAL ELECTRICITY N/A N/A COMMERCIAL OPERATION N/A N/A I

l 8311170401 831013 l

{DRADOCK 05000336 PDR 4

Ol Y~

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-336 UNIT Millstone 2 DATE 10/13/83 COMPLETED BY J. Gibson TELEPHONE (203) 447-1791 Ext. 4431 MONTH September 1983 DAY

' AVERAGE DAILY POWER LEVEL DAY - AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 0

17 0

2 0

18 0

3 0

19 0

4 0

20 0

.5 0

21 0

6 0

22 0

7 0

23 0

8 0

24 0

.9 0

25 0

10 0

26 0

11 0

27 0

l 12-0 28 0

l 13-0 29 0

14 0

30.

0 15 0

31 16 0

L INSTRUCTIONS

.On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

i.

l L

DOCKET NO. 50-336 UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT NAME Millstone 2 DATE 10/13/s3 COMPLETED BY J. Gibson REPORT MONTH September 1983 TELEPHONE (203) 447-1791 Ext. 4431

' Type Duration Reason Method of Licensee Systeg Compogent Cause & Corrective l

2 No.

Date (Hours)

Shutting Event Code Code Action to 3

Down Reactor Report #

Prevent Recurrence 5

830528 S

720 C

1 N/A N/A N/A Continuation of Refuel and Maintenance Outage

.from previous month.

a l

n i

1 2

3 4

F:

Forced Reason:

Method:

Exhibit G - Instructions S:

Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Other (Explain) (NUREG-0161)

E-Operator Training & License Examination F-Administrative 5

G-Operational Error (Explain)

Exihibit 1 - Same Source H-Other (Explain) i

Docket No. 50-336 Date 10/13/83 Unit Name Millstone 2 Completed By J. Gibson Telephone (203) 447-1791 Ext. 4431 CORRECTIVE MAINTENANCE

SUMMARY

FOR SAFETY RELATED EQUIPMENT REPORT MONTH September 1983 DATE SYSTEM COMPONENT MAINTENANCE ACTION 9/1/83 Service Water "C" Service Water Pump Removed "C" Service Water Pump and Motor 9/10/83 RBCCW "B" RBCCW Heat Exchanger Plugged tubes and re-installed manway covers on "B" RBCCW Heat Exchanger 9/10/83 AEA5 Actuation Module 613 Replaced Actuation Module 613 9/17/83 Main Steam Steam Dryers, SG #1 Removed and reinstalled steam dryers 9/17/83 Main Steam Deflector plate, SG #1 Installed new bolts and locking devices on deflector plate 9/17/83 Main Steam Steam Dryers, SG #2 Removed and reinstalled steam dryers 9/17/83 Main Steam Deflector plate, SG #2 Install deflector plate 9/26/83

.LPSI "A" LPSI pump Replaced casing gasket on "A" LPSI pump 9/28/83 RPS Low Flow Bistable Replaced Channel D Low Flow Bistable

. o Docket No. 50-336 Date:

10/13/83 Completed By: J. Gibson Telephone: (203) 447-1791 Ext. 4431 REFUELING INFORMATION REQUEST 1.

Name of facility: Millstone 2 2.

Scheduled date for next refueling shutdown:

Currently in Refuel / Maintenance Outage which commenced May 28, 1983.

3.

Schedule date for restart following refueling:

Estimated date for restart is unavailable.

NNECo is currently developing a schedule consistent with the repair of the reactor vessel thermal

-shield.

(See LER 83-24) 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?

It is anticipated that Cycle 6 operations will require Technical Specification changes or other License amendments.

Supporting information has already been submitted.

5.

Scheduled date(s) for submitting licensing action and supporting information:

A schedule has not been determined for further submittals.

6.

Important licensing considerations associated with refueling, e.g.,

new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in fuel design, new operating procedures:

Additional plugged S.G. tubes will result in reactor coolant flow j

reduction.

Currently planning to install sleeves in S.G. tubes.

Reactor Vessel thermal shield removal will be necessary prior to l

startup.

As previously identified to the NRC, NNECo has identified failed fuel at Millstone Unit 2.

The need to replace defective fuel l

assemblies will impact the core loading pattern and core physics l

parameters used as input to the safety analyses.

The effect of a 1

new loading pattern on the ongoing review of docketed material is not fully apparent at this time; however additional transient analysis may be required if significant loading pattern changes are needed.

(See LER 83-19/3L-1).

In addition, recent problems identified with the top nozzles of a number of fuel assemblies (See LERS 83-25 & 83-26) have left uncertainty as to the core loading plan. These problems are currently under review.

1 i

l m

3 7.

The number of fuel-assemblies (a) in the core and (b) in the spent fuel storage pool:

(a) 'In Core:

0 (b) 505 8.

The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies:

667 9.

The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:

1985, Spent Fuel Pool, Full core off load capacity is reached.

L1987, Core Full, Spent Fuel Pool contains 648 bundles.

d i

9 f

i 1

~..,

,...n-

r-O Q

e General Offices

'EiU s mNew HARTFORD. CONNECTICUT 06141-0270 (203) 666-6911 October 14, 1983 MP-5443 Director Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Reference:

Facility Operating License No. DPR-65 Docket No. 50-336

Dear Sir:

This letter is forwarded to provide the report of operating and shutdown experience relating to Millstone Unit 2 Monthly Operating Report 83-9 in accordance with Appendix A Technical Specifications, Section 6.9.1.3.

One additional copy of the report is enclosed.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY

/'/

d E. J. Mroczka Station Superintendent Millstone Nuclear Power Station EJM/JG:jlc cc:

Director, Office of Inspection and Enforcement, Region I Director, Office of Inspection and Enforcement, Washington, D. C. (10)

U. S. Nuclear Regulatory Commission, c/o Document Management Branch, Washington, D.C. 20555

@'>~

,