ML20081H611
| ML20081H611 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 10/25/1983 |
| From: | Schnell D UNION ELECTRIC CO. |
| To: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, ULNRC-679, NUDOCS 8311070523 | |
| Download: ML20081H611 (1) | |
Text
I AM8 UNION ELECTRIC COM PANY ISCI GRATIOT STREET ST. lou ts, MISSOU RI MAILINS ADORESS:
DON ALD F. SCHNELL P. O. BOM 949 October 25, 1983
'o
"' =ou a ' * = ' a v.e........,
skb Mr. James G. Keppler, Regional Administrator US Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 ULNRC-679
Dear Mr. Keppler:
On October 28, 1982 we informed NRC Region III of a potentially reportable deficiency regarding a group of Masoneilan main steam isolation bypass valves.
Subsequent evaluation has indicated that this deficiency, had it remained uncorrected, would not have adversely affected the safety of operations.
The valves in question, however, have been repaired and inspection of similar Masoneilan valves has revealed that they did not exhibit similar conditions.
This letter is being sent in response to a request by Mr. Konklin that we submit a written withdrawal of this potential 10CFR50.55(e).
Ver truly yoursg G>
Donald F.
Schnell JGJ/jds cc:
J.
E. Konklin, Region III Richard DeYoung, Director I&E NRC Resident Inspectors, Callaway Plant (2)
Missouri Public Service Commission l
l
[
$$%o O
PR l
DCT 2 71983 ZBs. ;' i1