ML20081D901
| ML20081D901 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island |
| Issue date: | 02/28/1995 |
| From: | Richard Anderson, Dugstad D NORTHERN STATES POWER CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 9503210064 | |
| Download: ML20081D901 (9) | |
Text
l 4
Northem States Power Company Prairie island Nuclear Generating Plant 1717 Wakonade Dr. East Welch, Minnesota 55089 March 14, 1995 Prairie Island Technical Specifications Section 6.7.A.3 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PIANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Monthly Operating Report February 1995 Attached is the Monthly Operating Report for Febt,ary 1995 for the Prairie Island Generating Plant.
Roger Anderson Director Licensing and Management Issues i
i c:
Director, Office of Resource Mana5ement Regional Administrator-III, NRC NRR Project Manager, NRC NRC Resident Inspector State of Minnesota - Kris Sanda Attachment 1
9503250064 950228 PDR ADOCK 0500 2
f/('
i
F s ?.,
~6' NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE l
DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE MARCH 2, 1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 MONTH:
FEBRUARY 1995 The Unit was base loaded this month.
On the 18th at 0013 a power reduction was started to conduct a turbine valve test and to clean condenser water box tubes.
At 0847 the generator was taken off line (reactor remained critical) starting a planned outage to replace a turine trip solenoid valve that had the potential of initiating an unplanned turbine trip. The information about this valve was recently obtained by NSP from a I
Westinghouse Turbine User's group meeting.
After all the work was completed the unit went on line at 1646 and reached full power operation at 2353.
i l
The outage ended a continuous operating run of 190 days CURRENT CONTINUOUS OPERATING RUN OF 10 DAYS.
AVERAGE DAILY UNIT POWER' LEVEL DOCKET NO. 50_-282
' UNIT PRAIRIE ISLAND NO.1 DATE MARCH 2, 1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 i
MONTH:
FEBRUARY 1995 f
DAY AVERAGE DAILY POWER LEVEL (MWE-NET) 1 532 2
532 3
532 4
532 5
533 6
531 7
532 8
532 9
532 10-533 7
11 533 12 531 13 533-14 528 15 537 16 530 17
-533 t
18 167 19 529 20 532 21 533 22 530 23 534 24 531 25 533 26 531 27 532 28 532 i
L i
AVERAGE LOADS ABOVE 513 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER
4 s
OPERATING DATA REPORT DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.1 DATE MARCH 2, 1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 OPERATING STATUS
.1. UNIT NAME:
PRAIRIE ISLAND NO. 1 2.
REPORTING PERIOD:
FEBRUARY 1995 3.
LICENSED THERMAL POWER (MWT):
1650 4.
NAMEPLATE RATING (GROSS MWE):
593 5.
DESIGN ELECTRICAL RATING (NET MWE):
530 6; MAXIMUM DEPENDABLE CAPACITY (GROSS MWE) : 545 7.
MAXIMUM DEPENDABLE CAPACITY (NET MWE) :
513 8.
IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT GIVE REASON:
NONE 9.-POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):
NONE
- 10. REASONS FOR RESTRICTIONS, IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD' 672 1416
'185880
- 12.-NUMBER OF HOURS REACTOR WAS CRITICAL 672.0 1416.0' 159015.3 r
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1.
- 14. HOURS GENERATOR ON-LINE 664.0 1408.0 157349.0
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1081353 2306749 249215388
. 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 366490 781950 82131600
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 348648 744190 77199457
- 19. UNIT SERVICE FACTOR 98.8 99.4 84.7
- 30. UNIT AVAILABILITY FACTOR 98.8 99.4 84.7
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 97.3 98.6 82.5
- 22. UNIT CAPACITY FACTOR (USING DER NET) 97.9 99.2 78.4
- 33. UNIT FORCED OUTAGE RATE 0.0 0.0 4.9
- 24. FORCED OUTAGE HOURS 0.0 0.0 8125.9
- 25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (?YPE, DATE & DURATION OF EACH):
N/A
- 36. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:
N/A
4 4
UNIT SHUTDOWNS AND POWER REDUCTION DOCKET NO 50-282 UNIT NAME PRAIRIE ISLAND-NO. 1 DATE MARCH 2, 1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376
. MONTH:
FEBRUARY 1995 DATE TYPE HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT YY/MM/DD 000.0 a
95/02/18 S
0.0 B
5 N/A Turbine valve test and condenser tube cleaning.
95/02/18 S
8.0 B
1 N/A Replace turbine trip solenoid valve.
t
[
r l
TYPE REASON METHOD SYSTEM CODE F-FORCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD S-SCHED B-MAINTENANCE OR TEST 2-MANUAL TRIP 805-1984(P805-DS)
C-REFUELING 3-AUTO TRIP l
D-REGULATORY RESTRICTION 4-CONTINUED l
E-OPERATOR TRAINING &
5-REDUCED LOAD COMPONENT CODE l
LICENSE EXAMINATION 9-OTHER F-ADMINISTRATIVE IEEE STD 803A-1983 G-OPERATIONAL ERROR l
H-0THER
Y, 1
NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE 1
DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO.2 DATE MARCH 2, 1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 MONTH:
FEBRUARY 1995 The Unit was base loaded this month, there were no power reductions or shutdowns.
I I
i i
f CURRENT CONTINUOUS OPERATING RUN OF 222 DAYS.
i l
..x.
' ' 'e '.
1,p 's e
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.-50-306 UNIT PRAIRIE ISLAND NO.2 DATE MARCH 2,-1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376-i MONTH:
FEBRUARY-1995 I
s' DAY AVERAGE DAILY POWER LEVEL (MWE-NET) i 1
530 2
530 3
531 4
531 5
533 6
529' 7
532 8
530
+
9 530 10 535 11-528 12 529 13 530 14 529 15 531 16 527 17 530 e
18 532 19 529 20 532 21 532 22 530 23
.531 24 529 25 531 26 529 27 531 l
28 531 AVERAGE LOADS ABOVE 512 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER 1
i
.,,e
OPERATING DATA REPORT DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO.2 DATE MARCH 2, 1995 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 OPERATING STATUS i
1.
UNIT NAME:
PRAIRIE ISLAND NO. 2 2.
REPORTING PERIOD:
FEBRUARY 1995 3.
LICENSED THERMAL POWER (MWT):
1650 4.
NAMEPLATE RATING (GROSS MWE) :
593 5.
DESIGN ELECTRICAL RATING (NET MWE) :
530 6.
MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 544 7.
MAXIMUM DEPENDABLE CAPACITY (NET MWE) :
512 8.
IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT GIVE REASON:
NONE j
9.
PUNER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):
NONE
- 10. REASONS FOR RESTRICTIONS, IF ANY:
NONE THIS MONTH YR-TO-DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD 672 1416 176998
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 672.0 1416.0 156526.2
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
- 14. HOURS GENERATOR ON-LINE 672.0 1416.0 155138.7
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 l
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1106558 2331382 246611604
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 374320 788930 80500970
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 356428 751331 76108827
- 19. UNIT SERVICE FACTOR 100.0 100.0 87.6
- 20. UNIT AVAILABILITY FACTOR 100.0 100.0 87.6
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 99.9 99.9 85.9
- 22. UNIT CAPACITY FACTOR (USING DER NET) 100.1 100.1 81.1
- 23. UNIT FORCED OUTAGE RATE 0.3 0.0 2.S
- 24. FORCED OUTAGE HOURS 0.0 0.0 3984.7
- 25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH):
REFUELING OUTAGE STARTING ON MAY 12, 1995.
- 26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:
N/A l
I i
i o
UNIT SHUTDOWNS AND POWER REDUCTION DOCKET NO 50-306 UNIT NAME PRAIRIE ISLAND NO. 2 DATE MARCH 2, 1995 CGMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121-4376 i
MONTH:
FEBRUARY 1995 DATE TYPE
-HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT YY/MM/DD 000.0 95/02/00 None.
TYPE REAGON METHOD SYSTEM CODE F-FOkCED A-EQUIPMENT FAILURE 1-MANUAL DRAFT IEEE STD I
S-SCHED B-MAINTENANCE OR TEST 2-MANUAL TRIP 80J-1984(P805-D5)
C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING &
5-REDUCED LOAD COMPONENT CODE LICENSE EXAMINATION 9-OTHER l
F-ADMINISTRATIVE IEEE STD 803A-1983 G-OPERATIONAL ERROR H-OTHER
- _..