ML20080R083
| ML20080R083 | |
| Person / Time | |
|---|---|
| Site: | Seabrook |
| Issue date: | 01/31/1984 |
| From: | Devincentis J PUBLIC SERVICE CO. OF NEW HAMPSHIRE |
| To: | Starostecki R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| SBN-618, NUDOCS 8402280083 | |
| Download: ML20080R083 (3) | |
Text
_ _ _ _ _ ______________ _
PUBLIC SERVICE SEABROM SWIM
- ..g.u osc.:
Companyof NewHampshire 1671 Worcester Road Framingham, Mossochusetts 01701 (617)- 872-8100 January 31, 1984 SBN-618 T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Richard W. Starostecki, Director Division of Project and Resident Programs
References:
(a) Construction Permits CPPR-135 and CPPR-136, Docaet Nos. 50-443 and 50-444 (b) Telecon of October 19, 1983, A. L. Legendre (YAEC) to Robert Gallo (NRC, Region I)
(c) PSNH Letter, dated November 21, 1983, " Interim 10CFR50.55(e) Report; Titeflex Corporation Flexible Hose Assemblies", J. DeVincentis to R. W. Starostecki
Subject:
Interim 10CFR50.55(e) Report; Titeflex Corporation Flexible Hose Assemblies
Dear Sir:
On October 19, 1983, a potentially reportable 10CFR50.55(e) item was reported [ Reference (b)] regarding Titeflex Corporation flexible hose assemblies.
Flexible hose assemblies supplied by Titeflex Corporation which are intended for use in the Component Cooling Water System (Class 3) and the Diesel Generator Coolant System (Class 3) are not in compliance with Section NC/ND 4810(c), Figure NC4810(c)-1 and NC/ND 5720(c) of the 1080 ASME,Section III, Division 1 Code.
A detailed y,ineering evaluation was undertaken which resulted in a redesign of the
- joint in question to meet ASME requirements.
Currently welding qualifit of the subject butt joint has been completed, and all hose assemblies.
r3 reworked and tested by Titeflex Corporation at their facility.
It has been determined that this item is reportable under 10CFR50.55(e).
A final report will be submitted on this subject when the hose assemblies have been returned for installation.
/
8402200083 040131 n
PDR ADOCK 05000443
{f S
PDR l
1
United States Nuclear Regulatory Commission January 31, 1984 Attention:
Mr. Richard W. Starostecki, Director Page 2 l
l This letter is being filed pursuant to interim reporting provisioa of l
10CFR50.55(e)(3).
l l
Very truly yours, n
John DeVincentis Project Manager cc: Atmic Safety and Licensing Board Service List i
~ _.
- 1 8
C William S., Jordan,.III, Esquire
- Brentwood Board of Selectmen Harmon & Weiss RED Dalton Road 1725 I Street, N.W. Suite 506~
3rentwood, New Hampshire 03833 Washington, DC 20006 b
Roy P. Lessy,:Jr., Esquire
.Cffice of the Executive Legal Director-Edward F. Meany U.S. Nuclear ~ Regulatory Commission Designated Representative of Washington, DC 20555 the Town of Rye 155 Washington Road
-Robert A. Backus, Esquire Rye, NH 03870 116 Lowell Street P.O.. Box 516 Calvin A. Canney Mancehster, NH 03105
. City Manager City Hall Philip Ahrens, Esquire 126 Daniel Street Assistant Attorney General Portsmouth, NH 03801 Department of the Attorney General Augusta, ME 04333 Dana Bisbee, Esquire Assistant Attorney General Mr. John B. Tanzer Office of the Attorney General Designated Representative of 208 State House Annex-the Town of-Hampton-Concord, NH 03842 5 Morningside Drive.
Hampton, NH 03842 Anne Verge, Chairperson Board of Selectmen Roberta C.JPevear Town Hall Designated Representative of South Hampton, NH 03842 the: Town of Hampton Falls Drinkwater Road Patrick J. McKeon
'Hampton Falls, NH 03844 Selectmen's Office 10 Central Road Mrs.' Sandra Gavutis Rye, NH 03870 Designated Representative of the Town of Kensington Carole F. Kagan, Esq.
RFD 1 Atomic Safety and Licensing Board Panel
~ East Kingston, NH 03827 U.S.-Nuclear Regulatory Commission Jo' Ann Shotwell, Esquire Assistant Attorney General Mr. Angie Machiros Environmental-Protection Bureau Chairman of-the Board of Selectmen Department of the Attorney General Town of Newbury One Ashburton Place, 19th Floor Newbury, MA 01950
' Boston, MA 02108
-Town Manager's Office Senator Gordon J. Humphrey-Town Hall.- Friend Street
-U.S. Senate
. Amesbury, Ma.
01913 Washington, DC 20510
.(Attn: ! Tom Burack)
Senator Gordon J. Humphrey 1 Pillsbury Street Diana.P.-Randall Concord, NH 03301 "70 Collinw. Street
.(Attn: Herb Boynton)
-SEabrook, NH 03874 Richard E. Sullivan, Mayor
' Donald E. Chick City Hall
' Town Manager.
Newburyport, MA 01950 Town of Exeter 10 Front Street Exeter, NH 03833
__.____.m_____.m__.____-
- - __ _ _ _ _.. - -... - _ _