.s.
DUKE POWER GOMPANY P.O. flox 33180 citAHLOTTE, N.C. 28242
[
September 27,19yT 3-a g.* 2g[ 4 gum"'
HALH. TUCKER
$3 NEN""
..... - o.
Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303 Re: Catawba Nuclear Station Units 1 and 2 Docket Nos.50-413 and 50-414
Dear Mr. O'Reilly:
Pursuant to 10 CFR 50.55e, please find attached Significant Deficiency Report SD 413-414/83-11.
Very truly years, Ab &
Hal B. Tucker RWO/php Attachment cc: Director INP0 Records Center Office of Inspection and Enforcement Suite 1500 U. S. Nuclear Regulatory Commission 1100 Circle 75 Parkway Washington, D. C. 20555 Atlanta, Georgia 30339 NRC Resident Inspector Mr. Robert Guild, Esq.
Catawba Nuclear Station Attorney-at-Law
.P. O. Box 12097 Palmetto Alliance Charleston, South Carolina 29412 21351 Devine Street Columbia, South Carolina 29205 OFFM& Af 8310060052 830927 PDR ADOCK 05000413
)l s
pon
^
f a,
s CATAWBA NUCLEAR STATION REPORT NUMBER: SD 413-414/83-11
-REPORT DATE: September 27, 1983 FACILTIY: Catawba Nuclear Station Units 1 and 2 IDENTIFICATION OF DEFICIENCY:
The Westinghouse NSSS Process Instrumentation and Control System NTC (Temperature Channel Test) cards utilize a mercury relay on. the card which
.has experienced contact bounce during seismic testing. The deficiency was identified by I. E. Notice 83-38 dated June 13,198a.
INITIAL REPORT:
On August 29, 1083, Virgil Brownlee of the NRC was notified of the deficiency by L. Coggins, J. Thomas, J. Smith, and C. Rolfe of Duke Power Company.
COMPONENT AND/0R SUPPLIER:
The NTC printed circuit cards were supplied by Westinghouse's Industry Electronics Division.
.' DESCRIPTION OF DEFICIENCY:
The NTC.-Temperature Channel test cards utilize a mercury relay on the card that may experience contact bounce during a seismic event. This intermittant contact bounce will result in signal saturation of the down stream NRA
.(RTD Amplifier) card in the T hot and T cold circuits of the 7300 Process Protection System. The saturation of the NRA card in plants utilizing non-filtered signals (which is applicable to Catawba) could delay
-initiation of over temperature-delta T and overpower-delta.T trips.
ANALYSIS OF SAFETY DUPLICATIONS:
< A possible delay could occur in. the initiation of.over temperature-delta' T and overpower-delta T trips if required during ~a seismic event. Such a
. delay could affect the safety of the plant.
CORRECTIVE ACTION:
There are 16 cards in each unit that have the deficient relay installed.
Westinghouse.is presently testing a-replacement relay and will inititate-the.necessary measures to correct the problem. A definite schedule has not been. established, but the resolution is expected prior to fuel load.