ML20080G512

From kanterella
Jump to navigation Jump to search
Forwards Const Implementation Overview Hold Point 015 Re Use of Thermocouples & Thermocouple Extension Wire
ML20080G512
Person / Time
Site: Midland
Issue date: 02/02/1984
From: Karr J
STONE & WEBSTER, INC.
To: Quamme D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
NUDOCS 8402130420
Download: ML20080G512 (3)


Text

..

~

.~ _ -

~

mm MI I

ll STONE A,ND WEB. STER MICHIGAN. INC.

h'b mC f PAL. STE.F.F

'g 3%v/Shh05:,410_[

2-1-W rs oars

,,1_.3 L_

" * ~ o-14509

!i R._ _.

.L.

l o ~* N/A l

!"uj..._[]_.[J SWOC - M -on i :

L' J

.3 t'ra ao

.19.1._ F r. :

l3 ti.

N/A l

l va

'..I 7

l--

- I CEAR SlHS:

--s--

L'V-$O

,,,,,,,,,,,,,,g,,,,,,,,,,g,,,,,,,,,,,g,,

D.L.QUAMME,CPCoMidland(site)

To

-.c.o co its mes t oovessoas arantu a ca os taen o-O==awmas O s eci>cario~s O oecu-i~rs O ~ ors o co~. i~ce j

STATUS l

PLEASE NOTE l

SENT FOR YOUR l Q ema6 0

ov =

10 rvis.o~s O o-.s=>o-.

I O a ova 6 0 co--a~r 10 su-- ar O a ove as ev' iso ' a =,** ',0,,,,,

O aoomo~s O co serio~.

O us O.~ o -ario~

9.

I,,,,

O co-- ~rs O

O itis O c'o~cu

~ce

'r-O ~ ~o co--=~r O u~acer vasta O usansvio~s as ~ovv.

rti OPEN DnACTION i YOUR ATTENTION IS DIR!:CTED TO THE FOLLOWING:

I nst.aAsso Pom O a==catio~ O c-ass o

~ress==== = area.'s l 0 t==ss== vise a~o su=='t

-~rs

==

oove>='ss

=>c o - a vu== c a== s.

O ooeu- ~rs O o a--a s O =~o== >a.. :

O s.zas su==n

~rs

oouc'='= =

-icao 'u.

ru a ca os o-O tzas

==vu ~ o co, saca o r-is -ar===' = =a-~o vou

  • ova 6====--= ~rs.

I O '= ass ac ~o-osace =<eri r o va

=ar

>=' =v >>=~-o a~o rvua~~= r~s

~eto=== co v o r is o -

=-

! O -r r se t-ar r-::: ~ovas

- acco==a~ce -ira voua u~o==='a~o ~a '

~or.

srass aaviss us I

IMPORTANT s outo ~, arvisio~ to oocu-r~1s o o awmas arrv=~ao me swiva mvo've.

=.es me saatsents u emamma on a t-se wn-m ve~ noi oars eve ~ twouan a os an estmare ca=~or = aiva~ ar var v.ust ovi, svo a e twe sv. ur -

-c. ov a -iss. vas u caass wiu.coaissos va avessoas -aos witaout conv.

The following Open CIO Item / Hold Point Notification (s) is (are) attached for your action /information:

)

oLb )oiur OI h

m.r se t

- s :.

J. E. Karr CIO Program Manager 3..

cc:

eppler, US NRC m

JJHarrison, US NRC RJCook, US NRC RAWells, CPCo CIO Site File

~

-]~

h 8402130420 840202 pgB.8 ggg r

PDR ADOCK 05000329 A

PDR

Sheet 1 of 2

""""*'"l"*'*'i'"*"""""

STONE & WEBSTER 0t CONSTRUCTION IMPLEMENTATION O TRACKED ACTION ITEM

~

OVERVIEW O TRACKED INFORMATION ITEM MIDLAND NUCLEAR PLANTJ.0. N0. M509 O TRACKED RECOMMENDATION ITEM REFERENCE (S)

O UNTRACKEDITEM PQCl PW-1.00 Revision 6

@ HOLD POINT NOTIFICATION CONDITION DETAILS Change Notice #AA-00004 to PQCI-1.00 deleted the requirements for the exclusive use of chromel-alumel thermocouples and extension wires for post weld heat treat-ment and also certification of the accuracy (calibration) of the thermocouples by means of a certificate of compliance.

Stone & Webster's concern is that only having verification of calibration of temperature controlling, indicating and recording instruments is inadequate because it neglects the sensing device.

If the temperature sensor (thermocouple and extension wire) is incorrect.or out of calibration, the entire temperature control and monitoring system will all be incorrect.

(Continued on Sheet 2 of 2)

O YES 'l/.E bNO ATTACHMENTS eb 10 984 86008/

/

RESPONSE

r E

O ves ':: :,

O NO ATTACHMENTS EST. CORRECTIVE ACTION RESPONDENT

, TITLE DATE COMPLETION DATE RESPONSE ACCEPTED DATE RESPONSE VERIFIED / CLOSED DATE

-umumum---eem

i

~

..??

L CONDITION DETAILS (continued)

Hold Point No. 015 s

Sheet 2 of 2

. Since post weld heat treatment is used wh?n there is a transition from stainless steel pipe.to. carbon steel pipe, as in'the case of the steam-

, generator. pipe to steam-turbine pipe, it is important that these critical

' ' _ welds be heat-treated properly.

For this, reason, in meetings with MPQAD, SWEC has requested that the requirements be reinstated into PQCI PW-1.00 and is issuing the following

" Hold Point" notification on the use of-thermocouples and-thermocouple extension wire. Release is contingent upon CIO review and acceptance of the calibration certification.

0 4

I

.. i a

T j'

q

_