ML20080G361

From kanterella
Jump to navigation Jump to search
Interim Significant Deficiency Rept SD 413-414/80-04 Re Replacement Guide Tube Support Pins.Unit 1 Pins Replaced. Unit 2 Pins to Be Installed by 840201
ML20080G361
Person / Time
Site: Catawba  Duke Energy icon.png
Issue date: 08/30/1983
From: Tucker H
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8309200241
Download: ML20080G361 (1)


Text

I

??

"~

DUKE POWER Goxiwxy USN-A77f,.Ek,?%,,/

P.o. nox camo CILAHLOTTE. N.O. 28242

  • i HALH.TCCKER

' uni [LEPif0:

TE non rame.ne=v (704) 373-4531 August 30, 19S3 8[? g A8: SS Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta,' Georgia 30303

- Re. : Catawba Nuclear Station Units 1 and 2 Docket Nos. 50-413 and 50-414

Dear Mr. O'Reilly:

In the Corrective Action section of Significant Deficiency Report SD 413-414/80-05, dated April 23, 1980, it was stated that the Catawba Unit i replacement guide tube support pins would be installed prior to operation and that the Unit 2 pins needed no corrective action at that time. The Unit 1 pins have been replaced.

The Unit 2 pins have been determined to need replacing as was done on Unit 1.

These pins have been received on-site and are to be installed by February 1, 1984.

Very truly yours, 2 /h

<r %

Hai B. Tucker RWO/php cc: Director INPO Records Center Office of Inspection and Enforcement Suite 1500 U.' S. Nuclear Regulatory Commission 1100 circle 75 Parkway Washington, D. C. 20555 Atlanta, Georgia 30339 NRC Resident Inspector Mr. Robert Guild, Esq.

Catawba Nuclear Station Attorney-at-Law P.O. Box 12097 Palmetto. Alliance Charleston, South Carolina 29412 213515 Devine Street Columbia, South Carolina 29205 8309200241 830830 DR ADOCK 05000413 OFFICM1' COPY PDR fS n